Akira Noda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Akira Noda has a total of 124 co-authors. Here are the top co-authors by number of shared publications:
- Hiroyuki Daido
Institute of Laser Engineering, The University of Osaka 1 , 2-6 Yamada-oka, Suita, Osaka 565-0871
4 shared publications - Koichi Ogura
Department of Musculoskeletal Oncology and Rehabilitation, National Cancer Center Hospital, Tokyo, Japan
4 shared publications - Mamiko Nishiuchi
Kansai Photon Science Institute (KPSI), National Institutes for Quantum and Radiological Science and Technology, 8-1-7 Umemidai, Kizugawa, Kyoto 610-0215, Japan
4 shared publications - Shu Nakamura
High Energy Accelerator Research Organization (KEK)
4 shared publications Toshiyuki Shirai
Institute for Chemical Research, Kyoto University, Gokasho, Uji, Kyoto 611-0011, Japan
4 shared publications- Yoshihisa Iwashita
Kyoto University
4 shared publications
Latest Publications
- 7 June 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1704, 464136
Estimation of confidence intervals for quantitation of coeluted peaks in liquid chromatography–Photodiode array detection through a combination of multivariate curve resolution-alternating least-square and Bayesian inference techniques
- 7 June 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1704, 464136
Estimation of confidence intervals for quantitation of coeluted peaks in liquid chromatography–Photodiode array detection through a combination of multivariate curve resolution-alternating least-square and Bayesian inference techniques
- 1 February 2021
- Published by Elsevier in Journal of Bioscience and Bioengineering
- Vol. 131  (2) , 207-212
Fake metabolomics chromatogram generation for facilitating deep learning of peak-picking neural networks
- 1 February 2021
- Published by Elsevier in Journal of Bioscience and Bioengineering
- Vol. 131  (2) , 207-212
Fake metabolomics chromatogram generation for facilitating deep learning of peak-picking neural networks
- 1 February 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 01936530,p. 358-359,359a
A 40Gb/s multi-data-rate CMOS transceiver chipset with SFI-5 interface for optical transmission systems
In this paper, 40 Gb/s SFI-5-compliant TX and RX chips in 65 nm CMOS technology consume 2.8 W each. This low power dissipation allows for a small and low-cost plastic BGA package. The TX has a full-rate clock architecture that is based on a 40 GHz VCO, a 40 Gb/s retiming D-FF, and 40 GHz clock-distribution circuits that lead to a low jitter of 0.57 psrms and 3.1 pspp at 40 Gb/s. A 40/20 GHz clock-timing-adjustment circuit based on a phase interpolator is used to ensure wide-range error-free operations (BER < 101Z) at 39.8 to 44.6 Gb/s. A quadruple loop architecture is introduced in the CDR circuit of the RX, resulting in a 38 Gb/s error-free operation (BER < 101Z) at 231-1 PRBS with a low rms jitter of 210 fs in the recovered clock.
- 1 February 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 01936530,p. 358-359,359a
A 40Gb/s multi-data-rate CMOS transceiver chipset with SFI-5 interface for optical transmission systems
In this paper, 40 Gb/s SFI-5-compliant TX and RX chips in 65 nm CMOS technology consume 2.8 W each. This low power dissipation allows for a small and low-cost plastic BGA package. The TX has a full-rate clock architecture that is based on a 40 GHz VCO, a 40 Gb/s retiming D-FF, and 40 GHz clock-distribution circuits that lead to a low jitter of 0.57 psrms and 3.1 pspp at 40 Gb/s. A 40/20 GHz clock-timing-adjustment circuit based on a phase interpolator is used to ensure wide-range error-free operations (BER < 101Z) at 39.8 to 44.6 Gb/s. A quadruple loop architecture is introduced in the CDR circuit of the RX, resulting in a 38 Gb/s error-free operation (BER < 101Z) at 231-1 PRBS with a low rms jitter of 210 fs in the recovered clock.
- Open Access
- 1 January 2008
- Published by Japan Society of Cosmetic Chemists of Japan in Journal of Society of Cosmetic Chemists of Japan
- Vol. 42  (4) , 289-296
An Influence of Cosmetic Formula on Thermal Characteristics and Its Relationship with the Sensation of Freshness during Application
- 1 January 2008
- Published by Japan Society of Cosmetic Chemists of Japan in Journal of Society of Cosmetic Chemists of Japan
- Vol. 42  (4) , 289-296
Open AccessAn Influence of Cosmetic Formula on Thermal Characteristics and Its Relationship with the Sensation of Freshness during Application
- Open Access
- 1 January 2008
- Published by Laser Society of Japan in The Review of Laser Engineering
- Vol. 36  (APLS) , 1123-1124
Laser Driven Particle Accelerators and their Application to Science, Industry and Medicine
- 1 January 2008
- Published by Laser Society of Japan in The Review of Laser Engineering
- Vol. 36  (APLS) , 1123-1124
Open AccessLaser Driven Particle Accelerators and their Application to Science, Industry and Medicine
- 20 July 2007
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 46  (8L) , L717
High-Quality Laser-Produced Proton Beam Realized by the Application of a Synchronous RF Electric Field
- 20 July 2007
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 46  (8L) , L717
High-Quality Laser-Produced Proton Beam Realized by the Application of a Synchronous RF Electric Field
- 24 June 2006
- Published by Springer Nature in Applied Physics B
- Vol. 84  (3) , 415-419
Development of a two-color interferometer for observing wide range electron density profiles with a femtosecond time resolution
- 24 June 2006
- Published by Springer Nature in Applied Physics B
- Vol. 84  (3) , 415-419
Development of a two-color interferometer for observing wide range electron density profiles with a femtosecond time resolution
- 6 March 2006
- Published by Cambridge University Press (CUP) in Laser and Particle Beams
- Vol. 24  (1) , 117-123
Observation of strongly collimated proton beam from Tantalum targets irradiated with circular polarized laser pulses
High-energy protons are generated by focusing an ultrashort pulsed high intensity laser at the Advanced Photon Research Center, JAERI-Kansai onto thin (thickness <10 μm) Tantalum targets. The laser intensities are about 4 × 1018 W/cm2. The prepulse level of the laser pulse is measured with combination of a PIN photo diode and a cross correlator and is less than 10−6. A quarter-wave plate is installed into the laser beam line to create circularly polarized pulses. Collimated high energy protons are observed with CH coated Tantalum targets irradiated with the circularly polarized laser pulses. The beam divergence of the generated proton beam is measured with a CR-39 track detector and is about 6 mrad.
- 6 March 2006
- Published by Cambridge University Press (CUP) in Laser and Particle Beams
- Vol. 24  (1) , 117-123
Observation of strongly collimated proton beam from Tantalum targets irradiated with circular polarized laser pulses
High-energy protons are generated by focusing an ultrashort pulsed high intensity laser at the Advanced Photon Research Center, JAERI-Kansai onto thin (thickness <10 μm) Tantalum targets. The laser intensities are about 4 × 1018 W/cm2. The prepulse level of the laser pulse is measured with combination of a PIN photo diode and a cross correlator and is less than 10−6. A quarter-wave plate is installed into the laser beam line to create circularly polarized pulses. Collimated high energy protons are observed with CH coated Tantalum targets irradiated with the circularly polarized laser pulses. The beam divergence of the generated proton beam is measured with a CR-39 track detector and is about 6 mrad.