Stuart Michael Stocks
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stuart Michael Stocks has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Gürkan Sin
Process and Systems Engineering Center (PROSYS), Department of Chemical and Biochemical Engineering, Technical University of Denmark (DTU), 2800 Kgs. Lyngby, Denmark
2 shared publications - Krist V. Gernaey
Technical University of Denmark, Department of Chemical and Biochemical Engineering, Kgs. Lyngby, Denmark
2 shared publications - Merve Öner
Process and Systems Engineering Center (PROSYS), Department of Chemical and Biochemical Engineering, Technical University of Denmark, 2800 Kongens Lyngby, Denmark
2 shared publications - Anna Eliasson Lantz
Technical University of Denmark
1 shared publication - Francis Tran
Leo Pharma A/S, Industriparken 55, 2750 Ballerup, Denmark
1 shared publication Frederico C.C. Montes
1 shared publication
Latest Publications
- 1 June 2022
- Published by Springer Nature in Biotechnology Letters
- Vol. 44 (7) , 813-822
Aerobic bioreactors: condensers, evaporation rates, scale-up and scale-down
Objectives Hydrodynamics, mixing and shear are terms often used when explaining or modelling scale differences, but other scale differences, such as evaporation, can arise from non-hydrodynamic factors that can be managed with some awareness and effort. Results We present an engineering approach to the prediction of evaporation rates in bioreactors based on gH2O/Nm3 of air entering and leaving the bioreactor and confirm its usefulness in a 28-run design of experiments investigating the effects of aeration rate (0.02 to 2.0 VVM), condenser temperature (10 to 20 °C), fill (2.5 to 5 kg), broth temperature (25 to 40 °C) and agitator speed (25 to 800 rpm). Aeration rate and condenser temperature used in the engineering prediction provided a practically useful estimate of evaporation; the other factors, while statistically identified as having some influence, were of negligible practical usefulness. Evaporation rates were never found to be zero, and could be at least 10% different to those expected at scale. Conclusions An assessment of evaporation rates for any project is encouraged, and it is recommended that the effects are accounted for by measurements, modelling or by tuning the exhaust cooling device temperature to minimize scale differences.
- 1 June 2022
- Published by Springer Nature in Biotechnology Letters
- Vol. 44 (7) , 813-822
Aerobic bioreactors: condensers, evaporation rates, scale-up and scale-down
Objectives Hydrodynamics, mixing and shear are terms often used when explaining or modelling scale differences, but other scale differences, such as evaporation, can arise from non-hydrodynamic factors that can be managed with some awareness and effort. Results We present an engineering approach to the prediction of evaporation rates in bioreactors based on gH2O/Nm3 of air entering and leaving the bioreactor and confirm its usefulness in a 28-run design of experiments investigating the effects of aeration rate (0.02 to 2.0 VVM), condenser temperature (10 to 20 °C), fill (2.5 to 5 kg), broth temperature (25 to 40 °C) and agitator speed (25 to 800 rpm). Aeration rate and condenser temperature used in the engineering prediction provided a practically useful estimate of evaporation; the other factors, while statistically identified as having some influence, were of negligible practical usefulness. Evaporation rates were never found to be zero, and could be at least 10% different to those expected at scale. Conclusions An assessment of evaporation rates for any project is encouraged, and it is recommended that the effects are accounted for by measurements, modelling or by tuning the exhaust cooling device temperature to minimize scale differences.
- Open Access
Independent Validation of an In Silico Tool for a Pilot-Scale Pharmaceutical Crystallization Process Development
There are many published models for predicting crystal size distribution (CSD) in the literature. However, none of them have been independently and comprehensively tested, which is important for industrial acceptance and confidence of these models. Therefore, in this study, using solubility and kinetic data from the literature, an in silico tool for predicting the crystallization process performance of a model compound system (paracetamol in ethanol) was developed and challenged by independent experiments at the 50 L pilot scale. The solute concentration was tracked, and the final CSD was quantified using three measurement techniques including a novel image analysis tool. The reported parameter uncertainties were also addressed using Monte Carlo simulations. The results showed that, when the models were used within their validity range (e.g., suspended solids), they were able to describe the observed process trends/dynamics (CSD and solute concentration) under varying experimental conditions (cooling time and seed mass) with R ranging from 0.72 and 0.90. Overall, the results indicate that, using Monte Carlo simulations to account for known parametric uncertainties, the models can support model-based approaches for crystallization process development from scale-down to scale-up studies as well as control evaluation.Open AccessIndependent Validation of an In Silico Tool for a Pilot-Scale Pharmaceutical Crystallization Process Development
There are many published models for predicting crystal size distribution (CSD) in the literature. However, none of them have been independently and comprehensively tested, which is important for industrial acceptance and confidence of these models. Therefore, in this study, using solubility and kinetic data from the literature, an in silico tool for predicting the crystallization process performance of a model compound system (paracetamol in ethanol) was developed and challenged by independent experiments at the 50 L pilot scale. The solute concentration was tracked, and the final CSD was quantified using three measurement techniques including a novel image analysis tool. The reported parameter uncertainties were also addressed using Monte Carlo simulations. The results showed that, when the models were used within their validity range (e.g., suspended solids), they were able to describe the observed process trends/dynamics (CSD and solute concentration) under varying experimental conditions (cooling time and seed mass) with R ranging from 0.72 and 0.90. Overall, the results indicate that, using Monte Carlo simulations to account for known parametric uncertainties, the models can support model-based approaches for crystallization process development from scale-down to scale-up studies as well as control evaluation. - 1 November 2020
- Published by Elsevier in Chemical Engineering Research and Design
- Vol. 163, 248-261
Comprehensive evaluation of a data driven control strategy: Experimental application to a pharmaceutical crystallization process
- 1 November 2020
- Published by Elsevier in Chemical Engineering Research and Design
- Vol. 163, 248-261
Comprehensive evaluation of a data driven control strategy: Experimental application to a pharmaceutical crystallization process
- 27 April 2012
- Published by Springer Nature in Biotechnology Letters
- Vol. 34 (8) , 1465-1473
Comparison of laser diffraction and image analysis for measurement of Streptomyces coelicolor cell clumps and pellets
Morphology is important in industrial processes involving filamentous organisms because it affects the mixing and mass transfer and can be linked to productivity. Image analysis provides detailed information about the morphology but, in practice, it is often laborious including both collection of high quality images and image processing. Laser diffraction is rapid and fully automatic and provides a volume-weighted distribution of the particle sizes. However, it is based on a number of assumptions that do not always apply to samples. We have evaluated laser diffraction to measure cell clumps and pellets of Streptomyces coelicolor compare to image analysis. Samples, taken five times during fed-batch cultivation, were analyzed by image analysis and laser diffraction. The volume-weighted size distribution was calculated for each sample. Laser diffraction and image analysis yielded similar size distributions, i.e. unimodal or bimodal distributions. Both techniques produced similar estimations of the population means, whereas the estimates of the standard deviations were generally higher using laser diffraction compared to image analysis. Therefore, laser diffraction measurements are high quality and the technique may be useful when rapid measurements of filamentous cell clumps and pellets are required.
- 27 April 2012
- Published by Springer Nature in Biotechnology Letters
- Vol. 34 (8) , 1465-1473
Comparison of laser diffraction and image analysis for measurement of Streptomyces coelicolor cell clumps and pellets
Morphology is important in industrial processes involving filamentous organisms because it affects the mixing and mass transfer and can be linked to productivity. Image analysis provides detailed information about the morphology but, in practice, it is often laborious including both collection of high quality images and image processing. Laser diffraction is rapid and fully automatic and provides a volume-weighted distribution of the particle sizes. However, it is based on a number of assumptions that do not always apply to samples. We have evaluated laser diffraction to measure cell clumps and pellets of Streptomyces coelicolor compare to image analysis. Samples, taken five times during fed-batch cultivation, were analyzed by image analysis and laser diffraction. The volume-weighted size distribution was calculated for each sample. Laser diffraction and image analysis yielded similar size distributions, i.e. unimodal or bimodal distributions. Both techniques produced similar estimations of the population means, whereas the estimates of the standard deviations were generally higher using laser diffraction compared to image analysis. Therefore, laser diffraction measurements are high quality and the technique may be useful when rapid measurements of filamentous cell clumps and pellets are required.
- 1 December 2008
- Published by Elsevier in Chemical Engineering Science
- Vol. 63 (24) , 5813-5820
Gassed and ungassed power draw in a pilot scale 550 litre fermentor retrofitted with up-pumping hydrofoil B2 impellers in media of different viscosity and with very high power draw
- 1 December 2008
- Published by Elsevier in Chemical Engineering Science
- Vol. 63 (24) , 5813-5820
Gassed and ungassed power draw in a pilot scale 550 litre fermentor retrofitted with up-pumping hydrofoil B2 impellers in media of different viscosity and with very high power draw