Eric Naab Manson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eric Naab Manson has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Stephen Inkoom
Radiation Protection Institute (RPI), Ghana Atomic Energy Commission, Accra, Ghana
4 shared publicationsIssahaku Shirazu
Radiological and Medical Sciences Research Institute, Ghana Atomic Energy Commission, Accra, Ghana
3 shared publicationsAbdul Nashirudeen Mumuni
Department of Medical Imaging, University for Development Studies, Tamale, Ghana
2 shared publications- Abdul Nashirudeen Mumuni
Department of Medical Imaging, School of Allied Health Sciences, University for Development Studies, Tamale, Ghana
2 shared publications Ahmed Mohammed Gedel
Department of Science Laboratory Technology, Accra Technical University, Accra, Ghana
2 shared publicationsDaniel Gyingiri Achel
Radiological and Medical Sciences Research Institute, Ghana Atomic Energy Commission, Accra, Ghana
2 shared publications
Latest Publications
- 6 April 2025
- Published by Elsevier in Radiography
- Vol. 31 (3) , 102942
Clinical learning experiences of medical imaging students in a resource-limited environment: A case study at the University for Development Studies, Ghana
- 6 April 2025
- Published by Elsevier in Radiography
- Vol. 31 (3) , 102942
Clinical learning experiences of medical imaging students in a resource-limited environment: A case study at the University for Development Studies, Ghana
- 25 January 2024
- Published by Springer Nature in Journal of Food Science and Technology
- Vol. 61 (8) , 1569-1577
Nutritional and toxicological assessment of Piliostigma thonnigii leaves and Tubaani food samples: a preliminary investigation
Tubaani is a local delicacy prepared with Piliostigma thonningii leaves. The leaves may contain trace/heavy metals and important phytonutrients that could impact consumers' health. Concerns over the nutritional and toxicological implications of Piliostigma thonningii leaves are critical. Tubaani food and Piliostigma thonningii leaf samples were investigated using Neutron Activation Analysis (NAA) and Spectrophotometry technique. The health risk of Tubaani was also assessed by calculating the target hazard quotient (THQ) and hazard index (HI) of potentially toxic elements. Fifteen trace elements were detected at non-toxicological concentrations in the samples analyzed. No significant difference (p > 0.05) was observed between the samples’ mean concentrations. The phenolic content in leaf extracts was higher as compared to the flavonoids. However, the flavonoids in the leaves had an effect on the food samples, unlike the phenols. The THQ and HI of the elements were below 1.0. There is no reason to be concerned about the current dietary intake of the potentially toxic elements in the routine consumption of Tubaani as portrayed in data obtained in this investigation by NAA, THQ, and HI.
- 25 January 2024
- Published by Springer Nature in Journal of Food Science and Technology
- Vol. 61 (8) , 1569-1577
Nutritional and toxicological assessment of Piliostigma thonnigii leaves and Tubaani food samples: a preliminary investigation
Tubaani is a local delicacy prepared with Piliostigma thonningii leaves. The leaves may contain trace/heavy metals and important phytonutrients that could impact consumers' health. Concerns over the nutritional and toxicological implications of Piliostigma thonningii leaves are critical. Tubaani food and Piliostigma thonningii leaf samples were investigated using Neutron Activation Analysis (NAA) and Spectrophotometry technique. The health risk of Tubaani was also assessed by calculating the target hazard quotient (THQ) and hazard index (HI) of potentially toxic elements. Fifteen trace elements were detected at non-toxicological concentrations in the samples analyzed. No significant difference (p > 0.05) was observed between the samples’ mean concentrations. The phenolic content in leaf extracts was higher as compared to the flavonoids. However, the flavonoids in the leaves had an effect on the food samples, unlike the phenols. The THQ and HI of the elements were below 1.0. There is no reason to be concerned about the current dietary intake of the potentially toxic elements in the routine consumption of Tubaani as portrayed in data obtained in this investigation by NAA, THQ, and HI.
- Open Access
- 15 November 2023
- Published by Hindawi Limited in International Journal of Biomedical Imaging
- Vol. 2023, 1-9
Assessment of the Impact of Turbo Factor on Image Quality and Tissue Volumetrics in Brain Magnetic Resonance Imaging Using the Three-Dimensional T1-Weighted (3D T1W) Sequence
Background. The 3D T1W turbo field echo sequence is a standard imaging method for acquiring high-contrast images of the brain. However, the contrast-to-noise ratio (CNR) can be affected by the turbo factor, which could affect the delineation and segmentation of various structures in the brain and may consequently lead to misdiagnosis. This study is aimed at evaluating the effect of the turbo factor on image quality and volumetric measurement reproducibility in brain magnetic resonance imaging (MRI). Methods. Brain images of five healthy volunteers with no history of neurological diseases were acquired on a 1.5 T MRI scanner with varying turbo factors of 50, 100, 150, 200, and 225. The images were processed and analyzed with FreeSurfer. The influence of the TFE factor on image quality and reproducibility of brain volume measurements was investigated. Image quality metrics assessed included the signal-to-noise ratio (SNR) of white matter (WM), CNR between gray matter/white matter (GM/WM) and gray matter/cerebrospinal fluid (GM/CSF), and Euler number (EN). Moreover, structural brain volume measurements of WM, GM, and CSF were conducted. Results. Turbo factor 200 produced the best SNR ( median = 17.01 ) and GM/WM CNR ( median = 2.29 ), but turbo factor 100 offered the most reproducible SNR ( IQR = 2.72 ) and GM/WM CNR ( IQR = 0.14 ). Turbo factor 50 had the worst and the least reproducible SNR, whereas turbo factor 225 had the worst and the least reproducible GM/WM CNR. Turbo factor 200 again had the best GM/CSF CNR but offered the least reproducible GM/CSF CNR. Turbo factor 225 had the best performance on EN (-21), while turbo factor 200 was next to the most reproducible turbo factor on EN (11). The results showed that turbo factor 200 had the least data acquisition time, in addition to superior performance on SNR, GM/WM CNR, GM/CSF CNR, and good reproducibility characteristics on EN. Both image quality metrics and volumetric measurements did not vary significantly ( p > 0.05 ) with the range of turbo factors used in the study by one-way ANOVA analysis. Conclusion. Since no significant differences were observed in the performance of the turbo factors in terms of image quality and volume of brain structure, turbo factor 200 with a 74% acquisition time reduction was found to be optimal for brain MR imaging at 1.5 T.
- 15 November 2023
- Published by Hindawi Limited in International Journal of Biomedical Imaging
- Vol. 2023, 1-9
Open AccessAssessment of the Impact of Turbo Factor on Image Quality and Tissue Volumetrics in Brain Magnetic Resonance Imaging Using the Three-Dimensional T1-Weighted (3D T1W) Sequence
Background. The 3D T1W turbo field echo sequence is a standard imaging method for acquiring high-contrast images of the brain. However, the contrast-to-noise ratio (CNR) can be affected by the turbo factor, which could affect the delineation and segmentation of various structures in the brain and may consequently lead to misdiagnosis. This study is aimed at evaluating the effect of the turbo factor on image quality and volumetric measurement reproducibility in brain magnetic resonance imaging (MRI). Methods. Brain images of five healthy volunteers with no history of neurological diseases were acquired on a 1.5 T MRI scanner with varying turbo factors of 50, 100, 150, 200, and 225. The images were processed and analyzed with FreeSurfer. The influence of the TFE factor on image quality and reproducibility of brain volume measurements was investigated. Image quality metrics assessed included the signal-to-noise ratio (SNR) of white matter (WM), CNR between gray matter/white matter (GM/WM) and gray matter/cerebrospinal fluid (GM/CSF), and Euler number (EN). Moreover, structural brain volume measurements of WM, GM, and CSF were conducted. Results. Turbo factor 200 produced the best SNR ( median = 17.01 ) and GM/WM CNR ( median = 2.29 ), but turbo factor 100 offered the most reproducible SNR ( IQR = 2.72 ) and GM/WM CNR ( IQR = 0.14 ). Turbo factor 50 had the worst and the least reproducible SNR, whereas turbo factor 225 had the worst and the least reproducible GM/WM CNR. Turbo factor 200 again had the best GM/CSF CNR but offered the least reproducible GM/CSF CNR. Turbo factor 225 had the best performance on EN (-21), while turbo factor 200 was next to the most reproducible turbo factor on EN (11). The results showed that turbo factor 200 had the least data acquisition time, in addition to superior performance on SNR, GM/WM CNR, GM/CSF CNR, and good reproducibility characteristics on EN. Both image quality metrics and volumetric measurements did not vary significantly ( p > 0.05 ) with the range of turbo factors used in the study by one-way ANOVA analysis. Conclusion. Since no significant differences were observed in the performance of the turbo factors in terms of image quality and volume of brain structure, turbo factor 200 with a 74% acquisition time reduction was found to be optimal for brain MR imaging at 1.5 T.
- Open Access
- 4 September 2023
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 54 (1) , 1-9
Evaluation of the impact of magnetic field homogeneity on image quality in magnetic resonance imaging: a baseline quantitative study at 1.5 T
Background: Magnetic resonance images can be affected in a number of ways by magnetic field inhomogeneity. The study aimed to optimize the main magnetic field homogeneity (MFH) by assessing how magnetic field inhomogeneity affects the signal-to-noise ratio (SNR) and geometric distortion of images acquired along the diameter of a spherical volume phantom from the isocenter of the MRI scanner. Results: The MFH ranged between 0.10 and 0.60 ppm. The best MFH and the maximum SNR were determined in the isocenter at 400 mm field of view with the application of shim. However, for all the phantom positions, geometrical distortion in images acquired at 200 mm field of view was generally better and worse at 400 mm field of view. MFH could be optimized to reduce geometrical distortion and increase SNR by increasing the receiver bandwidth and the number of excitations whiles complementing it with shimming during image acquisition. According to Chi-square independent test, there were no significant differences (p > 0.05) in the MFH, SNR, and geometrical distortion values. Compared to findings at higher field strengths, it was observed that MRI systems of higher field strengths (greater than 1.5 T) could offer superior magnetic field homogeneity and SNR without causing observable geometrical distortion. Conclusions: The optimal field of view for the fast field echo (FFE) sequence required to maximize MFH, SNR, and reduce distortion during image acquisition may vary across MRI systems of different field strengths. To determine the appropriate field of view, the method and results of this study could serve as a guide for medical physicists as part of their routine quality assurance test procedures.
- 4 September 2023
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 54 (1) , 1-9
Open AccessEvaluation of the impact of magnetic field homogeneity on image quality in magnetic resonance imaging: a baseline quantitative study at 1.5 T
Background: Magnetic resonance images can be affected in a number of ways by magnetic field inhomogeneity. The study aimed to optimize the main magnetic field homogeneity (MFH) by assessing how magnetic field inhomogeneity affects the signal-to-noise ratio (SNR) and geometric distortion of images acquired along the diameter of a spherical volume phantom from the isocenter of the MRI scanner. Results: The MFH ranged between 0.10 and 0.60 ppm. The best MFH and the maximum SNR were determined in the isocenter at 400 mm field of view with the application of shim. However, for all the phantom positions, geometrical distortion in images acquired at 200 mm field of view was generally better and worse at 400 mm field of view. MFH could be optimized to reduce geometrical distortion and increase SNR by increasing the receiver bandwidth and the number of excitations whiles complementing it with shimming during image acquisition. According to Chi-square independent test, there were no significant differences (p > 0.05) in the MFH, SNR, and geometrical distortion values. Compared to findings at higher field strengths, it was observed that MRI systems of higher field strengths (greater than 1.5 T) could offer superior magnetic field homogeneity and SNR without causing observable geometrical distortion. Conclusions: The optimal field of view for the fast field echo (FFE) sequence required to maximize MFH, SNR, and reduce distortion during image acquisition may vary across MRI systems of different field strengths. To determine the appropriate field of view, the method and results of this study could serve as a guide for medical physicists as part of their routine quality assurance test procedures.
- Open Access
- 6 August 2023
- Published by Elsevier in Scientific African
- Vol. 21
Fighting breast cancer in low-and-middle-income countries – What must we do to get every woman screened on regular basis?
- 6 August 2023
- Published by Elsevier in Scientific African
- Vol. 21
Open AccessFighting breast cancer in low-and-middle-income countries – What must we do to get every woman screened on regular basis?
- Open Access
- 17 November 2022
- Published by Walter de Gruyter GmbH in Polish Journal of Medical Physics And Engineering
- Vol. 28 (4) , 169-179
Development of a standard phantom for diffusion-weighted magnetic resonance imaging quality control studies: A review
Various materials and compounds have been used in the design of diffusion-weighted magnetic resonance imaging (DWMRI) phantoms to mimic biological tissue properties, including diffusion. This review thus provides an overview of the preparations of the various DW-MRI phantoms available in relation to the limitations and strengths of materials/solutions used to fill them. The narrative review conducted from relevant databases shows that synthesizing all relevant compounds from individual liquids, gels, and solutions based on their identified strengths could contribute to the development of a novel multifunctional DW-MRI phantom. The proposed multifunctional material at varied concentrations, when filled into a multi-compartment Perspex container of cylindrical or spherical geometry, could serve as a standard DW-MRI phantom. The standard multifunctional phantom could potentially provide DW-MRI quality control test parameters in one study session.
- 17 November 2022
- Published by Walter de Gruyter GmbH in Polish Journal of Medical Physics And Engineering
- Vol. 28 (4) , 169-179
Open AccessDevelopment of a standard phantom for diffusion-weighted magnetic resonance imaging quality control studies: A review
Various materials and compounds have been used in the design of diffusion-weighted magnetic resonance imaging (DWMRI) phantoms to mimic biological tissue properties, including diffusion. This review thus provides an overview of the preparations of the various DW-MRI phantoms available in relation to the limitations and strengths of materials/solutions used to fill them. The narrative review conducted from relevant databases shows that synthesizing all relevant compounds from individual liquids, gels, and solutions based on their identified strengths could contribute to the development of a novel multifunctional DW-MRI phantom. The proposed multifunctional material at varied concentrations, when filled into a multi-compartment Perspex container of cylindrical or spherical geometry, could serve as a standard DW-MRI phantom. The standard multifunctional phantom could potentially provide DW-MRI quality control test parameters in one study session.
- Open Access
- 13 October 2020
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 51 (1) , 1-11
Integrating image fusion with nanoparticle contrast agents for diagnosis: a review
Background: As newer technologies in the field of medical imaging continue to expand, development of unique techniques for optimizing image quality and minimizing radiation dose becomes very necessary for improve diagnosis of pathologies and patient safety. Different types of medical imaging devices have been developed for specific diagnostic purposes.Main text: This article provides a brief overview on the need for co-registration of some medical images into a single image (image fusion), advantages of some nanoparticle contrast agents in medical imaging, and a discussion of present and future role of integrating image fusion with nanoparticle contrast agents in diagnosis.Conclusion: The use of nanoparticle contrast agents together with image fusion is a promising technique in future medical imaging as is likely to reveal pathologies of ≤ 1 nm sizes.
- 13 October 2020
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 51 (1) , 1-11
Open AccessIntegrating image fusion with nanoparticle contrast agents for diagnosis: a review
Background: As newer technologies in the field of medical imaging continue to expand, development of unique techniques for optimizing image quality and minimizing radiation dose becomes very necessary for improve diagnosis of pathologies and patient safety. Different types of medical imaging devices have been developed for specific diagnostic purposes.Main text: This article provides a brief overview on the need for co-registration of some medical images into a single image (image fusion), advantages of some nanoparticle contrast agents in medical imaging, and a discussion of present and future role of integrating image fusion with nanoparticle contrast agents in diagnosis.Conclusion: The use of nanoparticle contrast agents together with image fusion is a promising technique in future medical imaging as is likely to reveal pathologies of ≤ 1 nm sizes.
- Open Access
- 1 January 2016
- Published by Medknow in Journal of Medical Physics
- Vol. 41 (2) , 153-6
Assessment of some image quality tests on a 128 slice computed tomography scanner using a Catphan700 phantom
Official publication of Association of Physicists of India
- 1 January 2016
- Published by Medknow in Journal of Medical Physics
- Vol. 41 (2) , 153-6
Open AccessAssessment of some image quality tests on a 128 slice computed tomography scanner using a Catphan700 phantom
Official publication of Association of Physicists of India