Adriana Coll De Peña
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Adriana Coll De Peña has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Anubhav Tripathi
Center for Biomedical Engineering, School of Engineering, Brown University, Providence, USA
8 shared publications - Blanca H. Lapizco-Encinas
Microscale Bioseparations Laboratory and Biomedical Engineering Department Rochester Institute of Technology Rochester New York USA
6 shared publications Cody J. Lentz
Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, 160 Lomb Memorial Drive, Rochester, New York 14623, United States
3 shared publicationsMatei Vaduva
Department of Molecular Biology, Cell Biology, and Biochemistry, Division of Biology and Medicine, Brown University, Providence, RI, USA
3 shared publicationsMenel Ben Frej
Applied Genomics, Revvity Hopkinton Massachusetts USA
3 shared publicationsAbbi Miller
Microscale Bioseparations Laboratory and Biomedical Engineering Department Rochester Institute of Technology Rochester NY USA
2 shared publications
Latest Publications
- Open Access
- 15 July 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (16) , 3701-3711
Characterizing ssRNA and dsRNA electrophoretic behavior: empirical insights with neural network-aided predictions
The behavior of ssRNA, dsRNA, and RNA with chemical modifications is studied intensively in a microfluidic electrophoresis platform and characterized using both empirical data and neural network-aided predictions.
- 15 July 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (16) , 3701-3711
Open AccessCharacterizing ssRNA and dsRNA electrophoretic behavior: empirical insights with neural network-aided predictions
The behavior of ssRNA, dsRNA, and RNA with chemical modifications is studied intensively in a microfluidic electrophoresis platform and characterized using both empirical data and neural network-aided predictions.
- 16 May 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (21) , 26984-26997
Electrophoretic Microfluidic Characterization of mRNA- and pDNA-Loaded Lipid Nanoparticles
Lipid nanoparticles (LNPs) are clinically advanced nonviral gene delivery vehicles with a demonstrated ability to address viral, oncological, and genetic diseases. However, the further development of LNP therapies requires rapid analytical techniques to support their development and manufacturing. The method developed and described in this paper presents an approach to rapidly and accurately analyze LNPs for optimized therapeutic loading by utilizing an electrophoresis microfluidic platform to analyze the composition of LNPs with different clinical lipid compositions (Onpattro, Comirnaty, and Spikevax) and nucleic acid (plasmid DNA (pDNA) and messenger RNA (mRNA)) formulations. This method enables the high-throughput screening of LNPs using a 96- or 384-well plate with approximate times of 2-4 min per sample using a total volume of 11 mu L. The lipid analysis requires concentrations approximately between 10(9) and 10(10) particles/mL and has an average precision error of 10.4% and a prediction error of 19.1% when compared to using a NanoSight, while the nucleic acid analysis requires low concentrations of 1.17 ng/mu L for pDNA and 0.17 ng/mu L for mRNA and has an average precision error of 4.8% and a prediction error of 9.4% when compared to using a PicoGreen and RiboGreen assay. In addition, our method quantifies the relative concentration of nucleic acid per LNP. Utilizing this approach, we observed an average of 263 +/- 62.2 mRNA per LNP and 126.3 +/- 21.2 pDNA per LNP for the LNP formulations used in this study, where the accuracy of these estimations is dependent on reference standards. We foresee the utility of this technique in the high-throughput characterization of LNPs during manufacturing and formulation research and development.
- 16 May 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (21) , 26984-26997
Electrophoretic Microfluidic Characterization of mRNA- and pDNA-Loaded Lipid Nanoparticles
Lipid nanoparticles (LNPs) are clinically advanced nonviral gene delivery vehicles with a demonstrated ability to address viral, oncological, and genetic diseases. However, the further development of LNP therapies requires rapid analytical techniques to support their development and manufacturing. The method developed and described in this paper presents an approach to rapidly and accurately analyze LNPs for optimized therapeutic loading by utilizing an electrophoresis microfluidic platform to analyze the composition of LNPs with different clinical lipid compositions (Onpattro, Comirnaty, and Spikevax) and nucleic acid (plasmid DNA (pDNA) and messenger RNA (mRNA)) formulations. This method enables the high-throughput screening of LNPs using a 96- or 384-well plate with approximate times of 2-4 min per sample using a total volume of 11 mu L. The lipid analysis requires concentrations approximately between 10(9) and 10(10) particles/mL and has an average precision error of 10.4% and a prediction error of 19.1% when compared to using a NanoSight, while the nucleic acid analysis requires low concentrations of 1.17 ng/mu L for pDNA and 0.17 ng/mu L for mRNA and has an average precision error of 4.8% and a prediction error of 9.4% when compared to using a PicoGreen and RiboGreen assay. In addition, our method quantifies the relative concentration of nucleic acid per LNP. Utilizing this approach, we observed an average of 263 +/- 62.2 mRNA per LNP and 126.3 +/- 21.2 pDNA per LNP for the LNP formulations used in this study, where the accuracy of these estimations is dependent on reference standards. We foresee the utility of this technique in the high-throughput characterization of LNPs during manufacturing and formulation research and development.
- 3 April 2024
- Published by Wiley in Electrophoresis
- Vol. 45 (17-18) , 1525-1534
Assessment of pDNA isoforms using microfluidic electrophoresis
The recent rise in nucleic acid–based vaccines and therapies has resulted in an increased demand for plasmid DNA (pDNA). As a result, there is added pressure to streamline the manufacturing of these vectors, particularly their design and construction, which is currently considered a bottleneck. A significant challenge in optimizing pDNA production is the lack of high‐throughput and rapid analytical methods to support the numerous samples produced during the iterative plasmid construction step and for batch‐to‐batch purity monitoring. pDNA is generally present as one of three isoforms: supercoiled, linear, or open circular. Depending on the ultimate use, the desired isoform may be supercoiled in the initial stages for cell transfection or linear in the case of mRNA synthesis. Here, we present a high‐throughput microfluidic electrophoresis method capable of detecting the three pDNA isoforms and determining the size and concentration of the predominant supercoiled and linear isoforms from 2 to 7 kb. The limit of detection of the method is 0.1 ng/µL for the supercoiled and linear isoforms and 0.5 ng/µL for the open circular isoform, with a maximum loading capacity of 10–15 ng/µL. The turnaround time is 1 min/sample, and the volume requirement is 10 µL, making the method suitable for process optimization and batch‐to‐batch analysis. The results presented in this study will enhance the understanding of electrophoretic transport in microscale systems dependent on molecular conformations and potentially aid technological advances in diverse areas relevant to microfluidic devices.
- 3 April 2024
- Published by Wiley in Electrophoresis
- Vol. 45 (17-18) , 1525-1534
Assessment of pDNA isoforms using microfluidic electrophoresis
The recent rise in nucleic acid–based vaccines and therapies has resulted in an increased demand for plasmid DNA (pDNA). As a result, there is added pressure to streamline the manufacturing of these vectors, particularly their design and construction, which is currently considered a bottleneck. A significant challenge in optimizing pDNA production is the lack of high‐throughput and rapid analytical methods to support the numerous samples produced during the iterative plasmid construction step and for batch‐to‐batch purity monitoring. pDNA is generally present as one of three isoforms: supercoiled, linear, or open circular. Depending on the ultimate use, the desired isoform may be supercoiled in the initial stages for cell transfection or linear in the case of mRNA synthesis. Here, we present a high‐throughput microfluidic electrophoresis method capable of detecting the three pDNA isoforms and determining the size and concentration of the predominant supercoiled and linear isoforms from 2 to 7 kb. The limit of detection of the method is 0.1 ng/µL for the supercoiled and linear isoforms and 0.5 ng/µL for the open circular isoform, with a maximum loading capacity of 10–15 ng/µL. The turnaround time is 1 min/sample, and the volume requirement is 10 µL, making the method suitable for process optimization and batch‐to‐batch analysis. The results presented in this study will enhance the understanding of electrophoretic transport in microscale systems dependent on molecular conformations and potentially aid technological advances in diverse areas relevant to microfluidic devices.
- Open Access
- 23 January 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 149 (5) , 1509-1517
Enzymatic isolation and microfluidic electrophoresis analysis of residual dsRNA impurities in mRNA vaccines and therapeutics
The versatility, rapid development, and ease of production scalability of mRNA therapeutics have placed them at the forefront of biopharmaceutical research. However, despite their vast potential to treat diseases, their novelty comes with unsolved analytical challenges. A key challenge in ensuring sample purity has been monitoring residual, immunostimulatory dsRNA impurities generated during the in vitro transcription of mRNA. Here, we present a method that combines an enzyme, S1 nuclease, to identify and isolate dsRNA from an mRNA sample with a microfluidic electrophoresis analytical platform to characterize the impurity. After the method was developed and optimized, it was tested with clinically relevant, pseudouridine-modified 700 and 1800 bp dsRNA and 818–4451 nt mRNA samples. While the treatment impacted the magnitude of the fluorescent signal used to analyze the samples due to the interference of the buffer with the labeling of the sample, this signal loss was mitigated by 8.8× via treatment optimization. In addition, despite the mRNA concentration being up to 400× greater than that of the dsRNA, under every condition, there was a complete disappearance of the main mRNA peak. While the mRNA peak was digested, the dsRNA fragments remained physically unaffected by the treatment, with no change to their migration time. Using these samples, we detected 0.25% dsRNA impurities in mRNA samples using 15 μL with an analytical runtime of 1 min per sample after digestion and were able to predict their size within 8% of the expected length. The short runtime, sample consumption, and high throughput compatibility make it suitable to support the purity assessment of mRNA during purification and downstream.
- 23 January 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 149 (5) , 1509-1517
Open AccessEnzymatic isolation and microfluidic electrophoresis analysis of residual dsRNA impurities in mRNA vaccines and therapeutics
The versatility, rapid development, and ease of production scalability of mRNA therapeutics have placed them at the forefront of biopharmaceutical research. However, despite their vast potential to treat diseases, their novelty comes with unsolved analytical challenges. A key challenge in ensuring sample purity has been monitoring residual, immunostimulatory dsRNA impurities generated during the in vitro transcription of mRNA. Here, we present a method that combines an enzyme, S1 nuclease, to identify and isolate dsRNA from an mRNA sample with a microfluidic electrophoresis analytical platform to characterize the impurity. After the method was developed and optimized, it was tested with clinically relevant, pseudouridine-modified 700 and 1800 bp dsRNA and 818–4451 nt mRNA samples. While the treatment impacted the magnitude of the fluorescent signal used to analyze the samples due to the interference of the buffer with the labeling of the sample, this signal loss was mitigated by 8.8× via treatment optimization. In addition, despite the mRNA concentration being up to 400× greater than that of the dsRNA, under every condition, there was a complete disappearance of the main mRNA peak. While the mRNA peak was digested, the dsRNA fragments remained physically unaffected by the treatment, with no change to their migration time. Using these samples, we detected 0.25% dsRNA impurities in mRNA samples using 15 μL with an analytical runtime of 1 min per sample after digestion and were able to predict their size within 8% of the expected length. The short runtime, sample consumption, and high throughput compatibility make it suitable to support the purity assessment of mRNA during purification and downstream.
- Open Access
- 10 January 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (3) , 4027-4036
Microfluidic AAV Purity Characterization: New Insights into Serotype and Sample Treatment Variability
Despite recent advances in nucleic acid delivery systems with the success of LNP vehicles, adeno-associated virus (AAV) remains the leading platform for targeted gene delivery due to its low immunogenicity to humans, high transduction efficiency, and range of serotypes with varying tropisms. Depending on the therapeutic goals and serotype used, different production conditions may be more amenable, generating an ever-growing need for rapid yet robust analytical techniques to support the high-quality manufacturing of AAV. A critical bottleneck exists for assessing full capsids where rapid, high-throughput techniques capable of analyzing a range of serotypes are needed. Here, we present a rapid, high-throughput analytical technique, microfluidic electrophoresis, for the assessment of full capsids compatible with AAV1, AAV2, AAV6, AAV8, and AAV9 without the need for assay modifications or optimizations, and AAV5 with some constraints. The method presented in this study uses a mathematical formulation we developed previously with a reference standard to combine the independently obtained capsid protein and single-stranded DNA (ssDNA) profiles to estimate the percentage of full capsids in a sample of unknown concentration. We assessed the ability to use a single serotype (AAV8) as the reference standard regardless of the serotype of the sample being analyzed so long as the melting temperature (Tm) of the capsids is within 12 °C from the Tm of AAV8. Using this method, we are able to characterize samples ±6.1% with an average analytical turnaround time of 12 VG/mL.
- 10 January 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (3) , 4027-4036
Open AccessMicrofluidic AAV Purity Characterization: New Insights into Serotype and Sample Treatment Variability
Despite recent advances in nucleic acid delivery systems with the success of LNP vehicles, adeno-associated virus (AAV) remains the leading platform for targeted gene delivery due to its low immunogenicity to humans, high transduction efficiency, and range of serotypes with varying tropisms. Depending on the therapeutic goals and serotype used, different production conditions may be more amenable, generating an ever-growing need for rapid yet robust analytical techniques to support the high-quality manufacturing of AAV. A critical bottleneck exists for assessing full capsids where rapid, high-throughput techniques capable of analyzing a range of serotypes are needed. Here, we present a rapid, high-throughput analytical technique, microfluidic electrophoresis, for the assessment of full capsids compatible with AAV1, AAV2, AAV6, AAV8, and AAV9 without the need for assay modifications or optimizations, and AAV5 with some constraints. The method presented in this study uses a mathematical formulation we developed previously with a reference standard to combine the independently obtained capsid protein and single-stranded DNA (ssDNA) profiles to estimate the percentage of full capsids in a sample of unknown concentration. We assessed the ability to use a single serotype (AAV8) as the reference standard regardless of the serotype of the sample being analyzed so long as the melting temperature (Tm) of the capsids is within 12 °C from the Tm of AAV8. Using this method, we are able to characterize samples ±6.1% with an average analytical turnaround time of 12 VG/mL.
- 7 July 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (16) , 3758-3767
A microfluidic electrophoretic dual dynamic staining method for the identification and relative quantitation of dsRNA contaminants in mRNA vaccines
MRNA vaccines ( i.e. , COVID-19 vaccine) offer various advantages over traditional vaccines in preventing and reducing disease and shortening the time between pathogen discovery and vaccine creation.
- 7 July 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (16) , 3758-3767
A microfluidic electrophoretic dual dynamic staining method for the identification and relative quantitation of dsRNA contaminants in mRNA vaccines
MRNA vaccines ( i.e. , COVID-19 vaccine) offer various advantages over traditional vaccines in preventing and reducing disease and shortening the time between pathogen discovery and vaccine creation.
- Open Access
An Optimized CoBRA Method for the Microfluidic Electrophoresis Detection of Breast Cancer Associated RASSF1 Methylation
Although breast cancer screening assays exist, many are inaccessible and have high turnaround times, leaving a significant need for better alternatives. Hypermethylation of tumor suppressor genes is a common epigenetic marker of breast cancer. Methylation tends to occur most frequently in the promoter and first exon regions of genes. Preliminary screening tests are crucial for informing patients whether they should pursue more involved testing. We selected RASSF1, previously demonstrated to be aberrantly methylated in liquid biopsies from breast cancer patients, as our gene of interest. Using CoBRA as our method for methylation quantification, we designed unique primer sets that amplify a portion of the CpG island spanning the 5′ end of the RASSF1 first exon. We integrated the CoBRA approach with a microfluidics-based electrophoresis quantification system (LabChip) and optimized the assay such that insightful results could be obtained without post-PCR purification or concentration, two steps traditionally included in CoBRA assays. Circumventing these steps resulted in a decreased turnaround time and mitigated the laboratory machinery and reagent requirements. Our streamlined technique has an estimated limit of detection of 9.1 ng/μL of input DNA and was able to quantify methylation with an average error of 4.3%.
Open AccessAn Optimized CoBRA Method for the Microfluidic Electrophoresis Detection of Breast Cancer Associated RASSF1 Methylation
Although breast cancer screening assays exist, many are inaccessible and have high turnaround times, leaving a significant need for better alternatives. Hypermethylation of tumor suppressor genes is a common epigenetic marker of breast cancer. Methylation tends to occur most frequently in the promoter and first exon regions of genes. Preliminary screening tests are crucial for informing patients whether they should pursue more involved testing. We selected RASSF1, previously demonstrated to be aberrantly methylated in liquid biopsies from breast cancer patients, as our gene of interest. Using CoBRA as our method for methylation quantification, we designed unique primer sets that amplify a portion of the CpG island spanning the 5′ end of the RASSF1 first exon. We integrated the CoBRA approach with a microfluidics-based electrophoresis quantification system (LabChip) and optimized the assay such that insightful results could be obtained without post-PCR purification or concentration, two steps traditionally included in CoBRA assays. Circumventing these steps resulted in a decreased turnaround time and mitigated the laboratory machinery and reagent requirements. Our streamlined technique has an estimated limit of detection of 9.1 ng/μL of input DNA and was able to quantify methylation with an average error of 4.3%.
- Open Access
- 29 June 2022
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 7 (27) , 23457-23466
Electrophoresis-Mediated Characterization of Full and Empty Adeno-Associated Virus Capsids
Adeno-associated virus (AAV) has shown great potential in gene therapy due to its low immunogenicity, lack of pathogenicity to humans, and ability to provide long-term gene expression in vivo. However, there is currently a need for fast, high-throughput characterization systems that require low volumes for the determination of its sample composition in terms of full and empty capsids since empty capsids are a natural byproduct of AAV synthesis. To address this need, the following study proposes a high-throughput electrophoresis-mediated microfluidics approach that is independent of sample input concentration to estimate the composition of a given sample by combining its protein and ssDNA information relative to a standard. Using this novel approach, we were able to estimate the percentage of full capsids of six AAV8 samples with an average deviation from the actual percentage of 4%. The experiments used for these estimations were conducted with samples of varying percentages of full capsids (21–75%) and varying concentrations (5 × 1011–1 × 1012 VP/mL) with a total volume requirement of 3–10 μL for triplicate analysis of the sample. This method offers a rapid way to evaluate the quality and purity of AAV products. We believe that our method addresses the critical need as recognized by the gene and molecular therapy community.
- 29 June 2022
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 7 (27) , 23457-23466
Open AccessElectrophoresis-Mediated Characterization of Full and Empty Adeno-Associated Virus Capsids
Adeno-associated virus (AAV) has shown great potential in gene therapy due to its low immunogenicity, lack of pathogenicity to humans, and ability to provide long-term gene expression in vivo. However, there is currently a need for fast, high-throughput characterization systems that require low volumes for the determination of its sample composition in terms of full and empty capsids since empty capsids are a natural byproduct of AAV synthesis. To address this need, the following study proposes a high-throughput electrophoresis-mediated microfluidics approach that is independent of sample input concentration to estimate the composition of a given sample by combining its protein and ssDNA information relative to a standard. Using this novel approach, we were able to estimate the percentage of full capsids of six AAV8 samples with an average deviation from the actual percentage of 4%. The experiments used for these estimations were conducted with samples of varying percentages of full capsids (21–75%) and varying concentrations (5 × 1011–1 × 1012 VP/mL) with a total volume requirement of 3–10 μL for triplicate analysis of the sample. This method offers a rapid way to evaluate the quality and purity of AAV products. We believe that our method addresses the critical need as recognized by the gene and molecular therapy community.
- 10 May 2021
- Published by Wiley in Electrophoresis
- Vol. 42 (23) , 2474-2482
On the potential of microscale electrokinetic cascade devices
Phages used for phage therapy of multi‐drug resistant bacteria must be highly purified prior to use. There are limited purification approaches that are broadly applicable to many phage types. Electrokinetics has shown great potential to manipulate phages, but obstructions from the cell debris produced during phage propagation can severely diminish the capacity of an electrokinetic device to concentrate and purify phage samples. A multipart insulator‐based electrokinetic device is proposed here to remove the larger, undesirable components of mixtures from phage preparations while transferring the freshly purified and concentrated sample to a second stage for downstream analysis. By combining the large debris prescreen and analysis stages in a streamlined system, this approach simultaneously reduces the impact of clogging and minimizes the sample loss observed during manual transferring of purified samples. Polystyrene particles were used to demonstrate a diminished sample loss of approximately one order of magnitude when using the cascade device as opposed to a manual transfer scheme. The purification and concentration of three different phage samples were demonstrated using the first stage of the cascade device as a prescreen. This design provides a simple method of purifying and concentrating valuable samples from a complex mixture that might impede separation capacity in a single channel. This article is protected by copyright. All rights reserved
- 10 May 2021
- Published by Wiley in Electrophoresis
- Vol. 42 (23) , 2474-2482
On the potential of microscale electrokinetic cascade devices
Phages used for phage therapy of multi‐drug resistant bacteria must be highly purified prior to use. There are limited purification approaches that are broadly applicable to many phage types. Electrokinetics has shown great potential to manipulate phages, but obstructions from the cell debris produced during phage propagation can severely diminish the capacity of an electrokinetic device to concentrate and purify phage samples. A multipart insulator‐based electrokinetic device is proposed here to remove the larger, undesirable components of mixtures from phage preparations while transferring the freshly purified and concentrated sample to a second stage for downstream analysis. By combining the large debris prescreen and analysis stages in a streamlined system, this approach simultaneously reduces the impact of clogging and minimizes the sample loss observed during manual transferring of purified samples. Polystyrene particles were used to demonstrate a diminished sample loss of approximately one order of magnitude when using the cascade device as opposed to a manual transfer scheme. The purification and concentration of three different phage samples were demonstrated using the first stage of the cascade device as a prescreen. This design provides a simple method of purifying and concentrating valuable samples from a complex mixture that might impede separation capacity in a single channel. This article is protected by copyright. All rights reserved
- 27 October 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (22) , 14885-14891
Simultaneous Determination of Linear and Nonlinear Electrophoretic Mobilities of Cells and Microparticles
Direct-current insulator-based electrokinetics (DC-iEK) is a branch of microfluidics that has demonstrated to be an attractive and efficient technique for manipulating micro- and nano- particles, including microorganisms. A unique feature of DC-iEK devices is that nonlinear EK effects are enhanced by the presence of regions of higher field intensity between the insulating structures. Accurate computational models, describing particle and cell behavior, are crucial to optimize the design and improve the performance of DC-iEK devices. The electrokinetic equilibrium condition (EEEC) is a recently introduced fundamental concept that has radically shifted the perspective behind the analysis of particle manipulation in these microfluidic devices. The EEEC takes into consideration previously neglected nonlinear effects on particle migration and indicates that these effects are central to control particle motion in DC-iEK devices. In this study, we present a simultaneous experimental characterization of linear and nonlinear electrokinetic (EK) parameters, that is, the electrophoretic mobility (μEP(1)), the particle zeta potential (ζP), the EEEC, and the electrophoretic mobility of the second kind (μEP(3)), for four types of polystyrene microparticles and four cell strains. For this, we studied the electromigration of polystyrene microparticles ranging in size from 2 to 6.8 μm, three bacteria strains (B. cereus, E. coli, and S. enterica) and a yeast cell (S. cerevisiae), ranging in size from 1 to 6.3 μm, in a polydimethylsiloxane (PDMS) microfluidic channel with a rectangular cross-section. The results illustrated that electrokinetic particle trapping can occur by linear and nonlinear electrophoresis and electroosmosis reaching an equilibrium, without the presence of insulating posts. The experimentally measured parameters reported herein will allow optimizing the design of future DC-iEK devices for a wide range of applications (e.g., to separate multiple kinds of particles and microorganisms) and for developing computational models that better represent reality.
- 27 October 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (22) , 14885-14891
Simultaneous Determination of Linear and Nonlinear Electrophoretic Mobilities of Cells and Microparticles
Direct-current insulator-based electrokinetics (DC-iEK) is a branch of microfluidics that has demonstrated to be an attractive and efficient technique for manipulating micro- and nano- particles, including microorganisms. A unique feature of DC-iEK devices is that nonlinear EK effects are enhanced by the presence of regions of higher field intensity between the insulating structures. Accurate computational models, describing particle and cell behavior, are crucial to optimize the design and improve the performance of DC-iEK devices. The electrokinetic equilibrium condition (EEEC) is a recently introduced fundamental concept that has radically shifted the perspective behind the analysis of particle manipulation in these microfluidic devices. The EEEC takes into consideration previously neglected nonlinear effects on particle migration and indicates that these effects are central to control particle motion in DC-iEK devices. In this study, we present a simultaneous experimental characterization of linear and nonlinear electrokinetic (EK) parameters, that is, the electrophoretic mobility (μEP(1)), the particle zeta potential (ζP), the EEEC, and the electrophoretic mobility of the second kind (μEP(3)), for four types of polystyrene microparticles and four cell strains. For this, we studied the electromigration of polystyrene microparticles ranging in size from 2 to 6.8 μm, three bacteria strains (B. cereus, E. coli, and S. enterica) and a yeast cell (S. cerevisiae), ranging in size from 1 to 6.3 μm, in a polydimethylsiloxane (PDMS) microfluidic channel with a rectangular cross-section. The results illustrated that electrokinetic particle trapping can occur by linear and nonlinear electrophoresis and electroosmosis reaching an equilibrium, without the presence of insulating posts. The experimentally measured parameters reported herein will allow optimizing the design of future DC-iEK devices for a wide range of applications (e.g., to separate multiple kinds of particles and microorganisms) and for developing computational models that better represent reality.