Qi Jia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Qi Jia has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Gangui Yan
Ministry of Education Key Laboratory of Modern Power System Simulation Control and Green Power Technology, Department of Electrical Engineering Northeast Electric Power University Jilin China
3 shared publications- Gangui Yan
Key Laboratory of Modern Power System Simulation and Control & Renewable Energy Technology, Ministry of Education, Northeast Electric Power University, Jilin 132012, China
2 shared publications - Junxi Wang
Key Laboratory of Modern Power System Simulation and Control and Renewable Energy Technology Ministry of Education, Northeast Electric Power University, Jilin, China
2 shared publications - Kan Liu
Key Laboratory of Modern Power System Simulation and Control and Renewable Energy Technology Ministry of Education, Northeast Electric Power University, Jilin, China
2 shared publications - Wenbo Hu
Key Laboratory of Modern Power System Simulation and Control and Renewable Energy Technology Ministry of Education, Northeast Electric Power University, Jilin, China
2 shared publications Yonglin Li
Northeast Electric Power University
2 shared publications
Latest Publications
- Open Access
- 9 December 2021
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 16 (7) , 1292-1304
Designing a low frequency oscillation stabiliser for wind turbine type‐4 based on the phase compensation method
A stabiliser is designed based on the phase compensation method to suppress the instability of wind‐turbine type‐4 in the low frequency mode [direct current voltage loop mode and phase‐locked loop mode]. Referring to the second‐order equation of synchronous generator rotor motion, the authors simplify and reconstruct the full‐order linearised model of wind‐turbine type‐4 and establish a current source damping torque model suitable for analysing the stability of the direct current voltage loop and phase‐locked loop. By analysing the damping phase of the direct current voltage loop and phase‐locked loop, introducing a phase compensation loop, and adjusting the phase and amplitude of the damping transfer loop, the authors could effectively enhance the damping of the direct current voltage loop and the phase‐locked loop and suppress the low frequency oscillation of wind‐turbine type‐4. The stabiliser is introduced into the linear model and the time domain simulation model. The effectiveness of the stabilisers is verified by the eigenvalue analysis and time domain simulation results.
- 9 December 2021
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 16 (7) , 1292-1304
Open AccessDesigning a low frequency oscillation stabiliser for wind turbine type‐4 based on the phase compensation method
A stabiliser is designed based on the phase compensation method to suppress the instability of wind‐turbine type‐4 in the low frequency mode [direct current voltage loop mode and phase‐locked loop mode]. Referring to the second‐order equation of synchronous generator rotor motion, the authors simplify and reconstruct the full‐order linearised model of wind‐turbine type‐4 and establish a current source damping torque model suitable for analysing the stability of the direct current voltage loop and phase‐locked loop. By analysing the damping phase of the direct current voltage loop and phase‐locked loop, introducing a phase compensation loop, and adjusting the phase and amplitude of the damping transfer loop, the authors could effectively enhance the damping of the direct current voltage loop and the phase‐locked loop and suppress the low frequency oscillation of wind‐turbine type‐4. The stabiliser is introduced into the linear model and the time domain simulation model. The effectiveness of the stabilisers is verified by the eigenvalue analysis and time domain simulation results.
- 30 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (1) , 717-730
Standalone Clamping Switched Capacitor-Based Modular DC Transformer for MVdc Application
This paper introduces a standalone clamping switched capacitor –based dc transformer (CSCDCT) for the medium-voltage dc power grid. The CSCDCT owns the functions of the dc fault isolation and the on-line redundant design, and hence the power distribution reliability can be guaranteed. It is also shown that the additional advantages of the CSCDCT are the matching regulation of the high-frequency ac voltages and the voltage self-balance of the dc capacitors. The coupling effect of ac voltage amplitudes and dc voltages can be eliminated by the matching regulation and the action of dc voltages will not alter the amplitude of high-frequency ac voltages in CSCDCT, improving the soft-switching performance, efficiency and control stability of the DCT system. Besides, by the self-balance capability, the dc capacitor voltage balancing mechanism is not required for the individual unit although two capacitors are used in each sub-module. This simplify the control system of the CSCDCT. The topology, operating mode, voltage matching modulation, current characteristic, switching performance, and power loss of the CSCDCT are investigated in detail. The correctness of the analysis is validated through the experimental and simulation results.
- 30 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (1) , 717-730
Standalone Clamping Switched Capacitor-Based Modular DC Transformer for MVdc Application
This paper introduces a standalone clamping switched capacitor –based dc transformer (CSCDCT) for the medium-voltage dc power grid. The CSCDCT owns the functions of the dc fault isolation and the on-line redundant design, and hence the power distribution reliability can be guaranteed. It is also shown that the additional advantages of the CSCDCT are the matching regulation of the high-frequency ac voltages and the voltage self-balance of the dc capacitors. The coupling effect of ac voltage amplitudes and dc voltages can be eliminated by the matching regulation and the action of dc voltages will not alter the amplitude of high-frequency ac voltages in CSCDCT, improving the soft-switching performance, efficiency and control stability of the DCT system. Besides, by the self-balance capability, the dc capacitor voltage balancing mechanism is not required for the individual unit although two capacitors are used in each sub-module. This simplify the control system of the CSCDCT. The topology, operating mode, voltage matching modulation, current characteristic, switching performance, and power loss of the CSCDCT are investigated in detail. The correctness of the analysis is validated through the experimental and simulation results.
- 8 December 2020
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 16 (2) , 725-736
Impact of DFIG-Based WTs on Subsynchronous Oscillation Damping of SG Based on the Net Electrical Damping Method
- 8 December 2020
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 16 (2) , 725-736
Impact of DFIG-Based WTs on Subsynchronous Oscillation Damping of SG Based on the Net Electrical Damping Method
- 13 October 2020
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 16 (1) , 1-13
Analysis of Subsynchronous Oscillation of Direct Drive PMSG Based Wind Farm Under Low Operating Condition
- 13 October 2020
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 16 (1) , 1-13
Analysis of Subsynchronous Oscillation of Direct Drive PMSG Based Wind Farm Under Low Operating Condition
- 16 August 2019
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 14 (6) , 2239-2250
Advanced Frequency Support Strategy of Double-Stage Grid-Connected PV Generation
- 16 August 2019
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 14 (6) , 2239-2250
Advanced Frequency Support Strategy of Double-Stage Grid-Connected PV Generation
- Open Access
- 20 June 2018
- Published by Springer Nature in Journal of Modern Power Systems and Clean Energy
- Vol. 7 (2) , 254-267
Small-signal stability analysis of photovoltaic generation connected to weak AC grid
- 20 June 2018
- Published by Springer Nature in Journal of Modern Power Systems and Clean Energy
- Vol. 7 (2) , 254-267
Open AccessSmall-signal stability analysis of photovoltaic generation connected to weak AC grid
- Open Access
- 1 January 2017
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2017 (13) , 2015-2020
Small signal stability analysis of paralleled inverters for multiple photovoltaic generation units connected to weak grid
In this study, a small signal model of paralleled inverters for multiple photovoltaic (PV) generation units (MPGUs) connected to weak grid is developed. Based on the proposed small signal model, eigenvalue analysis is employed to study the stability of MPGUs within different grid strength, different control parameters in each phase‐locked loop (PLL) controller and varying operating points in each PV generation unit. Furthermore, based on the transfer function of the power control loops in dq rotation frame, the coupling mechanism of operating point in each PV unit is revealed. The results show that: with the increasing of output power of PV unit among the PV generation and the decreasing of the grid strength, it may occur oscillation phenomena, the oscillation frequency is about 5 Hz; tuning gains of PLL has noticeable effect on the damping characteristic of the system, and larger PLL gains can improve system damping; each PV unit power control loop is coupled by the point of common coupling voltage, increasing the output power of PV unit, it may reduce the phase margin of the system transfer function and deteriorate the system stability. Theoretical analysis is verified with simulation of MPGUs connected to weak grid.
- 1 January 2017
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2017 (13) , 2015-2020
Open AccessSmall signal stability analysis of paralleled inverters for multiple photovoltaic generation units connected to weak grid
In this study, a small signal model of paralleled inverters for multiple photovoltaic (PV) generation units (MPGUs) connected to weak grid is developed. Based on the proposed small signal model, eigenvalue analysis is employed to study the stability of MPGUs within different grid strength, different control parameters in each phase‐locked loop (PLL) controller and varying operating points in each PV generation unit. Furthermore, based on the transfer function of the power control loops in dq rotation frame, the coupling mechanism of operating point in each PV unit is revealed. The results show that: with the increasing of output power of PV unit among the PV generation and the decreasing of the grid strength, it may occur oscillation phenomena, the oscillation frequency is about 5 Hz; tuning gains of PLL has noticeable effect on the damping characteristic of the system, and larger PLL gains can improve system damping; each PV unit power control loop is coupled by the point of common coupling voltage, increasing the output power of PV unit, it may reduce the phase margin of the system transfer function and deteriorate the system stability. Theoretical analysis is verified with simulation of MPGUs connected to weak grid.