Tongfang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tongfang Liu has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Laihua Yi
College of Automotive Engineering, Hunan Mechanical & Electrical Polytechnic, Changsha 410151, China
2 shared publications - Sheng Li
College of Automotive Engineering, Hunan Mechanical & Electrical Polytechnic, Changsha 410151, China
1 shared publication - Song Rui
College of Automotive Engineering, Hunan Mechanical & Electrical Polytechnic, Changsha 410151, China
1 shared publication - Xiongxiang Zhu
College of Automotive Engineering, Hunan Mechanical & Electrical Polytechnic, Changsha 410151, China
1 shared publication
Latest Publications
- Open Access
Layer-by-Layer Self-Assembly Composite Coatings for Improved Corrosion and Wear Resistance of Mg Alloy for Biomedical Applications
Mg alloys are promising biomedical metal due to their natural degradability, good processability, and favorable mechanical properties. However, the poor corrosion resistance limits their further clinical applications. In this study, the combined strategies of surface chemical treatment and layer-by-layer self-assembly were used to prepare composite coatings on Mg alloys to improve the biocorrosion resistance. Specially, alkalized AZ91 Mg alloy generated chemical linkage with silane via Si–O–Mg covalent bond at the interface. Subsequently, Si–OH group from silane formed a crosslinked silane layer by Si–O–Si network. Further chemical assembly with graphene oxide (GO), lengthened the diffusion pathway of corrosive medium. The chemically assembled composite coatings could firmly bond to Mg alloy substrate, which persistently and effectively acted as compact barriers against corrosion propagation. Improved biocorrosion resistance of AZ91 Mg alloy with self-assembly composite coatings of silane/GO was subsequently confirmed by immersion tests. Besides, the Mg alloy exhibited good wear resistance due to outside layer of GO with a lubricant effect. Cell viability of higher than 75% had also been found for the alloy with self-assembly composite coatings, which showed good cytocompatibility.
Open AccessLayer-by-Layer Self-Assembly Composite Coatings for Improved Corrosion and Wear Resistance of Mg Alloy for Biomedical Applications
Mg alloys are promising biomedical metal due to their natural degradability, good processability, and favorable mechanical properties. However, the poor corrosion resistance limits their further clinical applications. In this study, the combined strategies of surface chemical treatment and layer-by-layer self-assembly were used to prepare composite coatings on Mg alloys to improve the biocorrosion resistance. Specially, alkalized AZ91 Mg alloy generated chemical linkage with silane via Si–O–Mg covalent bond at the interface. Subsequently, Si–OH group from silane formed a crosslinked silane layer by Si–O–Si network. Further chemical assembly with graphene oxide (GO), lengthened the diffusion pathway of corrosive medium. The chemically assembled composite coatings could firmly bond to Mg alloy substrate, which persistently and effectively acted as compact barriers against corrosion propagation. Improved biocorrosion resistance of AZ91 Mg alloy with self-assembly composite coatings of silane/GO was subsequently confirmed by immersion tests. Besides, the Mg alloy exhibited good wear resistance due to outside layer of GO with a lubricant effect. Cell viability of higher than 75% had also been found for the alloy with self-assembly composite coatings, which showed good cytocompatibility.
- Open Access
Ultrasonic Treatment Induced Fluoride Conversion Coating without Pores for High Corrosion Resistance of Mg Alloy
Fluoride conversion (MgF2) coating with facile preparation and good adhesion is promising to protect Mg alloy, but defects of pores in the coating lead to limited corrosion resistance. In this study, a compact and dense MgF2 coating was prepared by the combination of fluoride treatment and ultrasonic treatment. The ultrasonically treated MgF2 coating showed a compact and dense structure without pores at the frequency of 28 kHz. The chemical compositions of the coating were mainly composed of F and Mg elements. The corrosion potential of the ultrasonically treated Mg alloy shifted towards the noble direction in the electrochemical tests. The corrosion current density decreased due to the protectiveness of MgF2 coating without defects of pores or cracks. During immersion tests for 24 h, the ultrasonically treated Mg alloy exhibited the lowest H2 evolution (0.32 mL/cm2) and pH value (7.3), which confirmed the enhanced anti-corrosion ability of MgF2 coating. Hence, the ultrasonically treated fluoride coating had great potentials for their use in anti-corrosion applications of Mg alloy.
Open AccessUltrasonic Treatment Induced Fluoride Conversion Coating without Pores for High Corrosion Resistance of Mg Alloy
Fluoride conversion (MgF2) coating with facile preparation and good adhesion is promising to protect Mg alloy, but defects of pores in the coating lead to limited corrosion resistance. In this study, a compact and dense MgF2 coating was prepared by the combination of fluoride treatment and ultrasonic treatment. The ultrasonically treated MgF2 coating showed a compact and dense structure without pores at the frequency of 28 kHz. The chemical compositions of the coating were mainly composed of F and Mg elements. The corrosion potential of the ultrasonically treated Mg alloy shifted towards the noble direction in the electrochemical tests. The corrosion current density decreased due to the protectiveness of MgF2 coating without defects of pores or cracks. During immersion tests for 24 h, the ultrasonically treated Mg alloy exhibited the lowest H2 evolution (0.32 mL/cm2) and pH value (7.3), which confirmed the enhanced anti-corrosion ability of MgF2 coating. Hence, the ultrasonically treated fluoride coating had great potentials for their use in anti-corrosion applications of Mg alloy.