LJLeisheng Jiang

Leisheng Jiang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Leisheng Jiang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of a novel customized cutting and rotating template for Bernese periacetabular osteotomy

    by Xuyi Wang, Shixian Liu, Jianping Peng, Zhonglian Zhu, Linlin Zhang, Jianzhong Guan, Xiaodong Chen

    Bernese periacetabular osteotomy (PAO) has been shown to be applicable as a hip-preserving technique for the treatment of developmental dysplasia of the hip (DDH). The approach could be designed preoperatively using various types of reverse-engineering software and finite element analysis, but how to implement it in the actual PAO remains a challenge. This study examines and evaluates a solution to achieve higher accuracy when performing a PAO. A patient-specific cutting and rotating template was predesigned through computer-aided design (CAD) with three-dimensional (3D) modeling programs. The templates were then reproduced with rapid prototyping (RP) technology and used in the actual PAO. Finally, the clinical and radiographic effects were assessed and compared between the newly developed PAO and conventional PAO groups. The customized cutting template fit well with the bone surface and served as a guide for surgeons as they slid the osteotome to the precise location that had been determined prior to surgery. A very similar acetabular fragment was reproduced, and no major complications occurred when performing the osteotomy along the edge of the cutting template. The acetabular fragment was then corrected to the predetermined position through one-off manipulation with the customized rotating template. The final position of the acetabular fragment in the new developed PAO group was highly consistent with the planned position, and the postoperative morphological parameters were consistent with the preoperative planned data compared to the conventional PAO group. The duration of the operation and the number of irradiation decreased significantly. The Harris hip score (HHS) and visual analogue scale (VAS) score improved significantly with the use of the new developed PAO. We demonstrate that our system, which was based on CAD-RP technology, is feasible and could realize the predicted results accurately during the actual PAO.


  • Open Access

    Does the optimal position of the acetabular fragment should be within the radiological normal range for all developmental dysplasia of the hip? A patient-specific finite element analysis

    by Xuyi Wang, Jianping Peng, De Li, Linlin Zhang, Hui Wang, Leisheng Jiang, Xiaodong Chen

    The success of Bernese periacetabular osteotomy depends significantly on how extent the acetabular fragment can be corrected to its optimal position. This study was undertaken to investigate whether correcting the acetabular fragment into the so-called radiological “normal” range is the best choice for all developmental dysplasia of the hip with different severities of dysplasia from the biomechanical view? If not, is there any correlation between the biomechanically optimal position of the acetabular fragment and the severity of dysplasia? Four finite element models with different severities of dysplasia were developed. The virtual periacetabular osteotomy was performed with the acetabular fragment rotated anterolaterally to incremental center-edge angles; then, the contact area and pressure and von Mises stress in the cartilage were calculated at different correction angles. The optimal position of the acetabular fragment for patients 1, 2, and 3 was when the acetabular fragment rotated 17° laterally (with the lateral center-edge angle of 36° and anterior center-edge angle of 58°; both were slightly larger than the “normal” range), 25° laterally following further 5° anterior rotation (with the lateral center-edge angle of 31° and anterior center-edge angle of 51°; both were within the “normal” range), and 30° laterally following further 10° anterior rotation (with the lateral center-edge angle of 25° and anterior center-edge angle of 40°; both were less than the “normal” range), respectively. The optimal corrective position of the acetabular fragment is severity dependent rather than within the radiological “normal” range for developmental dysplasia of the hip. We prudently proposed that the optimal correction center-edge angle of mild, moderate, and severe developmental dysplasia of the hip is slightly larger than the “normal” range, within the “normal” range, and less than the lower limit of the “normal” range, respectively.