Jan-Niklas Klatt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jan-Niklas Klatt has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Nils Paust
Hahn-Schickard, Freiburg, Germany; European Liquid Biopsy Society (ELBS), Hamburg, Germany; IMTEK - Department of Microsystems Engineering, Laboratory for MEMS Applications, University of Freiburg, Freiburg, Germany, Germany
4 shared publications - Oliver Schilling
Institute of Surgical Pathology, Faculty of Medicine, Medical Center - University of Freiburg, 79106 Freiburg, Germany
3 shared publications Tobias Hutzenlaub
Hahn-Schickard, Georges-Koehler-Allee 103, Freiburg 79110, Germany
3 shared publications- Carolin Kleber
Laboratory for MEMS Applications, IMTEK - Department of Microsystems Engineering, University of Freiburg, Germany
2 shared publications F. Schmidt
Weill Cornell Medicine – Qatar
2 shared publications- Manuel Metzger
Hahn-Schickard, Georges-Koehler-Allee 304, 79110 Freiburg, Germany
2 shared publications
Latest Publications
- Open Access
Sample preparation for direct nanopore based protein identification via tryptic peptide recognition
Rapid, cost-efficient and miniaturized protein analysis is essential for point-of-care clinical diagnostics. Nanopores offer a promising alternative to mass spectrometry, offering high-resolution, single-molecule sensing with a minimal footprint. However, peptide-level protein identification remains challenging due to difficulties in assigning nanopore signals to peptide sequences and the incompatibility of conventional proteolysis workflows with nanopore sensing. Here we integrate a single-pot, solid-phase-enhanced sample preparation (SP3) workflow with nanopore sensing. The SP3 protocol decouples proteolysis from interfering components via magnetic bead cleanup, yielding a digest compatible with nanopore sensing. As a proof of concept, tryptic digests of myelin basic protein measured with an engineered aerolysin variant (AeL-R220S) generated a reproducible five-peak peptide fingerprint. Cross-validation against a synthetic peptide library and LC-MS/MS enabled reference-based assignment of blockade signatures to four MBP-derived peptides. This approach establishes SP3 as a sample-preparation workflow for nanopore sensing, paving the way for label-free identification and characterization of protein targets.
Open AccessSample preparation for direct nanopore based protein identification via tryptic peptide recognition
Rapid, cost-efficient and miniaturized protein analysis is essential for point-of-care clinical diagnostics. Nanopores offer a promising alternative to mass spectrometry, offering high-resolution, single-molecule sensing with a minimal footprint. However, peptide-level protein identification remains challenging due to difficulties in assigning nanopore signals to peptide sequences and the incompatibility of conventional proteolysis workflows with nanopore sensing. Here we integrate a single-pot, solid-phase-enhanced sample preparation (SP3) workflow with nanopore sensing. The SP3 protocol decouples proteolysis from interfering components via magnetic bead cleanup, yielding a digest compatible with nanopore sensing. As a proof of concept, tryptic digests of myelin basic protein measured with an engineered aerolysin variant (AeL-R220S) generated a reproducible five-peak peptide fingerprint. Cross-validation against a synthetic peptide library and LC-MS/MS enabled reference-based assignment of blockade signatures to four MBP-derived peptides. This approach establishes SP3 as a sample-preparation workflow for nanopore sensing, paving the way for label-free identification and characterization of protein targets.
- Open Access
- 15 June 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (13) , 4058-4073
Centrifugal microfluidic automation of the protein aggregation capture workflow for robust mass spectrometry-based proteomics
The AutoPAC-disk is a centrifugal microfluidic disk for protein aggregation capture-based sample preparation in bottom-up proteomics, enabling automated on-bead proteolysis with pre-stored buffers.
- 15 June 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (13) , 4058-4073
Open AccessCentrifugal microfluidic automation of the protein aggregation capture workflow for robust mass spectrometry-based proteomics
The AutoPAC-disk is a centrifugal microfluidic disk for protein aggregation capture-based sample preparation in bottom-up proteomics, enabling automated on-bead proteolysis with pre-stored buffers.
- Open Access
- 31 March 2026
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 25 (5) , 2486-2494
MR-SP 2 : A Microreactor-Based Workflow for Few-Cell Spatial Proteomics on the Legacy Zeiss PALM MicroBeam
Laser capture microdissection (LCM) combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) enables spatial proteomics at the few-cell level but is constrained by cumulative losses during specimen capture, surface adsorption during processing, and sample transfer prior to LC-MS/MS analysis. The capture-associated losses are particularly relevant for pressure catapulting systems such as the legacy Zeiss PALM MicroBeam, which, despite discontinuation, remains in active use and therefore requires compatible low-loss workflows. We present MR-SP2 (microreactor-based sample preparation for spatial proteomics), a one-pot workflow integrating reproducible Zeiss LCM-cut specimen capture, processing with minimized adsorptive losses, and pipetting-free transfer with Evotip disposable precolumns. The workflow was evaluated using a formalin-fixed paraffin-embedded (FFPE) murine kidney tissue analyzed by timsTOF flex LC-MS/MS analysis. Across 50,000 μm3 regions (22 cells), MR-SP2 modestly improved proteome depth (3381 ± 80 versus 3174 ± 59 proteins). Decreasing sample input further accentuated the advantage of MR-SP2 in maintaining higher identification rates, highlighting the successful reduction of the adsorptive losses. At 12,500 μm3 (5-6 cells), identifications increased to 1145 ± 188 versus 302 ± 126. At 3125 μm3 (1-2 cells), identifications reached 695 ± 112 versus 206 ± 51. MR-SP2 improves identification depth for few-cell FFPE samples by nearly 3-fold compared to conventional tube-based workflows.
- 31 March 2026
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 25 (5) , 2486-2494
Open AccessMR-SP 2 : A Microreactor-Based Workflow for Few-Cell Spatial Proteomics on the Legacy Zeiss PALM MicroBeam
Laser capture microdissection (LCM) combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) enables spatial proteomics at the few-cell level but is constrained by cumulative losses during specimen capture, surface adsorption during processing, and sample transfer prior to LC-MS/MS analysis. The capture-associated losses are particularly relevant for pressure catapulting systems such as the legacy Zeiss PALM MicroBeam, which, despite discontinuation, remains in active use and therefore requires compatible low-loss workflows. We present MR-SP2 (microreactor-based sample preparation for spatial proteomics), a one-pot workflow integrating reproducible Zeiss LCM-cut specimen capture, processing with minimized adsorptive losses, and pipetting-free transfer with Evotip disposable precolumns. The workflow was evaluated using a formalin-fixed paraffin-embedded (FFPE) murine kidney tissue analyzed by timsTOF flex LC-MS/MS analysis. Across 50,000 μm3 regions (22 cells), MR-SP2 modestly improved proteome depth (3381 ± 80 versus 3174 ± 59 proteins). Decreasing sample input further accentuated the advantage of MR-SP2 in maintaining higher identification rates, highlighting the successful reduction of the adsorptive losses. At 12,500 μm3 (5-6 cells), identifications increased to 1145 ± 188 versus 302 ± 126. At 3125 μm3 (1-2 cells), identifications reached 695 ± 112 versus 206 ± 51. MR-SP2 improves identification depth for few-cell FFPE samples by nearly 3-fold compared to conventional tube-based workflows.
- 8 June 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (24) , 8508-8516
Miniaturization, Parallelization, and Automation of Endotoxin Detection by Centrifugal Microfluidics
We demonstrate microfluidic automation and parallelization of Limulus amebocyte lysate (LAL)-based bacterial endotoxin testing using centrifugal microfluidics. LAL is the standard reagent to test for endotoxin contaminations in injectable pharmaceuticals. The main features of the introduced system are more than 90% reduction of LAL consumption, from 100 μL/reaction to 9.6 μL/reaction, automated liquid handling to reduce opportunities for contamination and manual handling errors, and microfluidic parallelization by integrating 104 reactions into a single centrifugal microplate. In a single Eclipse microplate, 21 samples and their positive product controls are tested in duplicate. In addition, a standard curve with up to five points is generated, resulting in a total of 104 reactions. Test samples with a defined concentration of 0.5 endotoxin units per milliliter were tested, resulting in a coefficient of variation below 0.75%. A key feature for achieving a small coefficient of variation is ensuring the same path length along the microfluidic channels to the final reaction chambers for each sample and the reagent, so that any unspecific adsorption to the polymer surfaces does not affect the accuracy and precision. Analysis of a sample containing naturally occurring endotoxin with the developed microfluidic microplate yielded comparable results to the conventional testing method. A test with eight commercially available pharmaceuticals was found to pass all requirements for bacterial endotoxin testing as specified in the United States Pharmacopeia. The automated endotoxin testing system reveals specific advantages of centrifugal microfluidics for analytical biochemistry applications. Small liquid volumes are handled (metered, mixed, and aliquoted) in a very precise, highly integrated, and highly parallel manner within mass-fabricated microplates.
- 8 June 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (24) , 8508-8516
Miniaturization, Parallelization, and Automation of Endotoxin Detection by Centrifugal Microfluidics
We demonstrate microfluidic automation and parallelization of Limulus amebocyte lysate (LAL)-based bacterial endotoxin testing using centrifugal microfluidics. LAL is the standard reagent to test for endotoxin contaminations in injectable pharmaceuticals. The main features of the introduced system are more than 90% reduction of LAL consumption, from 100 μL/reaction to 9.6 μL/reaction, automated liquid handling to reduce opportunities for contamination and manual handling errors, and microfluidic parallelization by integrating 104 reactions into a single centrifugal microplate. In a single Eclipse microplate, 21 samples and their positive product controls are tested in duplicate. In addition, a standard curve with up to five points is generated, resulting in a total of 104 reactions. Test samples with a defined concentration of 0.5 endotoxin units per milliliter were tested, resulting in a coefficient of variation below 0.75%. A key feature for achieving a small coefficient of variation is ensuring the same path length along the microfluidic channels to the final reaction chambers for each sample and the reagent, so that any unspecific adsorption to the polymer surfaces does not affect the accuracy and precision. Analysis of a sample containing naturally occurring endotoxin with the developed microfluidic microplate yielded comparable results to the conventional testing method. A test with eight commercially available pharmaceuticals was found to pass all requirements for bacterial endotoxin testing as specified in the United States Pharmacopeia. The automated endotoxin testing system reveals specific advantages of centrifugal microfluidics for analytical biochemistry applications. Small liquid volumes are handled (metered, mixed, and aliquoted) in a very precise, highly integrated, and highly parallel manner within mass-fabricated microplates.
- 7 June 2021
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 3 (7) , 3278-3286
Blocking Protein Adsorption in Microfluidic Chips by a Hydrophobin Coating
- 7 June 2021
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 3 (7) , 3278-3286
Blocking Protein Adsorption in Microfluidic Chips by a Hydrophobin Coating
- 19 April 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (11) , 2255-2264
Automation of peptide desalting for proteomic liquid chromatography – tandem mass spectrometry by centrifugal microfluidics
We present a centrifugal microfluidic disk that automates all liquid handling steps required for peptide desalting by solid phase extraction.
- 19 April 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (11) , 2255-2264
Automation of peptide desalting for proteomic liquid chromatography – tandem mass spectrometry by centrifugal microfluidics
We present a centrifugal microfluidic disk that automates all liquid handling steps required for peptide desalting by solid phase extraction.
- 6 July 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (16) , 2937-2946
Tryptic digestion of human serum for proteomic mass spectrometry automated by centrifugal microfluidics
Tryptic digestion of human serum automated by centrifugal microfluidics.
- 6 July 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (16) , 2937-2946
Tryptic digestion of human serum for proteomic mass spectrometry automated by centrifugal microfluidics
Tryptic digestion of human serum automated by centrifugal microfluidics.