Debjyoti Chowdhury
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Debjyoti Chowdhury has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Madhurima Chattopadhyay
Heritage Institute of Technology
15 shared publications Madhurima Chattopadhyay
Heritage Institute of Technology
5 shared publicationsSantanu Mondal
Techno India
3 shared publications- Santu Guin
Electronics and Instrumentation Engineering, Techno Main Salt Lake, Salt Lake, Sector-5, Kolkata 700091, West Bengal, India
2 shared publications Sriparna Sahu
Heritage Institute of Technology
2 shared publications- Sunam Saha
Adamas University
2 shared publications
Latest Publications
- Open Access
A Comparative Study Between Micro and Millimeter Impedance Sensor Designs for Type-2 Diabetes Detection
In recent years, various types of sensors have been developed at both millimeter (mm) and micrometer (µm) scales for numerous biomedical applications. Each design has its own advantages and limitations. This study compares the electrical characteristics and sensitivity of millimeter- and micrometer-scale sensors, emphasizing the superior performance of millimeter-scale designs for detecting type-2 diabetes. Elevated glucose levels in type-2 diabetes alter the complex permittivity of red blood cells (RBCs), affecting their rheological and electrical properties, such as viscosity, volume, relative permittivity, dielectric loss, and AC conductivity. These alterations may manifest as a unique bio-impedance signature, offering a diagnostic topology for diabetes. In view of this, various concentrations (ranging from 10% to 100%) of 400 µL of normal and diabetic RBCs suspended in phosphate-buffered saline (PBS) solution are examined to record the changes in bio-impedance signatures across a spectrum of frequencies, ranging from 1 MHz to 10 MHz. In this study, simulations are performed using the finite element method (FEM) with COMSOL Multiphysics® to analyze the electrical behavior of the sensors at both millimeter (mm) and micrometer (µm) scales. These simulations provide valuable insights into the performance parameters of the sensors, aiding in the selection of the most effective design by using this topology.
Open AccessA Comparative Study Between Micro and Millimeter Impedance Sensor Designs for Type-2 Diabetes Detection
In recent years, various types of sensors have been developed at both millimeter (mm) and micrometer (µm) scales for numerous biomedical applications. Each design has its own advantages and limitations. This study compares the electrical characteristics and sensitivity of millimeter- and micrometer-scale sensors, emphasizing the superior performance of millimeter-scale designs for detecting type-2 diabetes. Elevated glucose levels in type-2 diabetes alter the complex permittivity of red blood cells (RBCs), affecting their rheological and electrical properties, such as viscosity, volume, relative permittivity, dielectric loss, and AC conductivity. These alterations may manifest as a unique bio-impedance signature, offering a diagnostic topology for diabetes. In view of this, various concentrations (ranging from 10% to 100%) of 400 µL of normal and diabetic RBCs suspended in phosphate-buffered saline (PBS) solution are examined to record the changes in bio-impedance signatures across a spectrum of frequencies, ranging from 1 MHz to 10 MHz. In this study, simulations are performed using the finite element method (FEM) with COMSOL Multiphysics® to analyze the electrical behavior of the sensors at both millimeter (mm) and micrometer (µm) scales. These simulations provide valuable insights into the performance parameters of the sensors, aiding in the selection of the most effective design by using this topology.
- 29 October 2024
- Published by Springer Nature
- p. 93-101
Assessment of High Gain Hybrid Converter Fed BLDC Motor Drive for Electric Vehicle
- 29 October 2024
- Published by Springer Nature
- p. 93-101
Assessment of High Gain Hybrid Converter Fed BLDC Motor Drive for Electric Vehicle
- 18 April 2024
- Published by Springer Nature in Microsystem Technologies
- Vol. 30 (11) , 1477-1484
A novel methodology for detection of Malaria
- 18 April 2024
- Published by Springer Nature in Microsystem Technologies
- Vol. 30 (11) , 1477-1484
A novel methodology for detection of Malaria
- Open Access
- 1 March 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 15 (1) , 27-34
A novel technique for torque ripple suppression in BLDC motor drive using switched capacitor based SEPIC converter
This article reports a strategy for suppressing commutation torque ripple has been proposed by modifying a SEPIC converter using switched capacitor. The torque ripple generated during the commutation period is one of the main disadvantages of a brushless DC (BLDC) motor. The cause for the torque ripple in brushless DC motor has been mathematically analyzed in this work. Henceforth, a modified switched-capacitor based DC-DC converter has been proposed for integration with BLDC drive. Moreover, a theoretical analysis of the relationship has been established between the duty ratio of the DC-DC converter with commutation time and torque ripple. A low cost and simple method to control the dc link voltage of BLDC drive has been proposed and a comparative analysis of the proposed converter with previously existing similar converters has been shown. This work aims at reducing ripple in electromagnetic torque of BLDC motor from the view point of duty ratio of the DC-DC converter and commutation time of the drive. The feasibility of the drive has been evaluated experimentally and through simulation. It has been observed that the integration of the proposed converter with BLDC drive help in torque ripple suppression to 16.5% as compared to BLDC drive without any DC-DC converter.
- 1 March 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 15 (1) , 27-34
Open AccessA novel technique for torque ripple suppression in BLDC motor drive using switched capacitor based SEPIC converter
This article reports a strategy for suppressing commutation torque ripple has been proposed by modifying a SEPIC converter using switched capacitor. The torque ripple generated during the commutation period is one of the main disadvantages of a brushless DC (BLDC) motor. The cause for the torque ripple in brushless DC motor has been mathematically analyzed in this work. Henceforth, a modified switched-capacitor based DC-DC converter has been proposed for integration with BLDC drive. Moreover, a theoretical analysis of the relationship has been established between the duty ratio of the DC-DC converter with commutation time and torque ripple. A low cost and simple method to control the dc link voltage of BLDC drive has been proposed and a comparative analysis of the proposed converter with previously existing similar converters has been shown. This work aims at reducing ripple in electromagnetic torque of BLDC motor from the view point of duty ratio of the DC-DC converter and commutation time of the drive. The feasibility of the drive has been evaluated experimentally and through simulation. It has been observed that the integration of the proposed converter with BLDC drive help in torque ripple suppression to 16.5% as compared to BLDC drive without any DC-DC converter.
- Open Access
- 16 December 2023
- Published by MDPI AG in Electronics
- Vol. 12 (24) , 5030
Enhancing Outdoor Moving Target Detection: Integrating Classical DSP with mmWave FMCW Radars in Dynamic Environments
This paper introduces a computationally inexpensive technique for moving target detection in challenging outdoor environments using millimeter-wave (mmWave) frequency-modulated continuous-wave (FMCW) radars leveraging traditional signal processing methodologies. Conventional learning-based techniques for moving target detection suffer when there are variations in environmental conditions. Hence, the work described here leverages robust digital signal processing (DSP) methods, including wavelet transform, FIR filtering, and peak detection, to efficiently address variations in reflective data. The evaluation of this method is conducted in an outdoor environment, which includes obstructions like woods and trees, producing an accuracy score of 92.0% and precision of 91.5%. Notably, this approach outperforms deep learning methods when it comes to operating in changing environments that project extreme data variations.
- 16 December 2023
- Published by MDPI AG in Electronics
- Vol. 12 (24) , 5030
Open AccessEnhancing Outdoor Moving Target Detection: Integrating Classical DSP with mmWave FMCW Radars in Dynamic Environments
This paper introduces a computationally inexpensive technique for moving target detection in challenging outdoor environments using millimeter-wave (mmWave) frequency-modulated continuous-wave (FMCW) radars leveraging traditional signal processing methodologies. Conventional learning-based techniques for moving target detection suffer when there are variations in environmental conditions. Hence, the work described here leverages robust digital signal processing (DSP) methods, including wavelet transform, FIR filtering, and peak detection, to efficiently address variations in reflective data. The evaluation of this method is conducted in an outdoor environment, which includes obstructions like woods and trees, producing an accuracy score of 92.0% and precision of 91.5%. Notably, this approach outperforms deep learning methods when it comes to operating in changing environments that project extreme data variations.
- 17 July 2023
- Published by Elsevier in Microprocessors and Microsystems
- Vol. 101
An on-device machine learning assisted system for unobtrusive cardiac auscultation
- 17 July 2023
- Published by Elsevier in Microprocessors and Microsystems
- Vol. 101
An on-device machine learning assisted system for unobtrusive cardiac auscultation
- 15 June 2023
- Published by Springer Nature
- p. 113-123
IoT Based Automatic Temperature Screening & Alert System for Symptomatic COVID-19 Detection
- 15 June 2023
- Published by Springer Nature
- p. 113-123
IoT Based Automatic Temperature Screening & Alert System for Symptomatic COVID-19 Detection
- 17 June 2021
- Published by Springer Nature
- p. 115-125
Study of Non-biological Property for Identification Cancerous Skin Tissue
- 17 June 2021
- Published by Springer Nature
- p. 115-125
Study of Non-biological Property for Identification Cancerous Skin Tissue
- 9 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-8
Study and Classification of Cell Bio-Impedance Signature for Identification of Malignancy Using Artificial Neural Network
This article presents development of a microcapacitive sensor-based bio-impedance classification system for identification of malignant cells in a known volume (400 μL) of biological tissue sample. Malignancy induces various physical changes in an affected cell, among which increased intracellular water and sodium ion content are a couple of prominent ones. In this work, the change in electrical properties of a cell [here white blood cell (WBC)] that is membrane and cytoplasm permittivity due to afore-mentioned reasons is used for distinguishing malignant from normal cells based on their deviation in bio-impedance signature. This change in bio-impedance signature of the WBC is measured by exciting the mentioned microcapacitive sensor by a 2 V p-p signal. The developed system consists of an on-board impedance analyzer to carry out bio-impedance spectroscopy over a frequency range of 1-100 kHz. The bio-impedance data are then obtained from the sensor for different concentrations of cultured human malignant and normal white blood cells. The difference in impedance values between concentrations is then used as a discerning factor for identification the degree of malignancy, for which an artificial neural network (ANN) is employed. A detailed study considering detection efficiency for this ANN revealed classification accuracy up to 95.0%, upon which this ANN model is transferred to a portable single board computer (SBC) along with other associated circuitry that could carry out the same classification at a nominal power consumption of 516.45 mW.
- 9 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-8
Study and Classification of Cell Bio-Impedance Signature for Identification of Malignancy Using Artificial Neural Network
This article presents development of a microcapacitive sensor-based bio-impedance classification system for identification of malignant cells in a known volume (400 μL) of biological tissue sample. Malignancy induces various physical changes in an affected cell, among which increased intracellular water and sodium ion content are a couple of prominent ones. In this work, the change in electrical properties of a cell [here white blood cell (WBC)] that is membrane and cytoplasm permittivity due to afore-mentioned reasons is used for distinguishing malignant from normal cells based on their deviation in bio-impedance signature. This change in bio-impedance signature of the WBC is measured by exciting the mentioned microcapacitive sensor by a 2 V p-p signal. The developed system consists of an on-board impedance analyzer to carry out bio-impedance spectroscopy over a frequency range of 1-100 kHz. The bio-impedance data are then obtained from the sensor for different concentrations of cultured human malignant and normal white blood cells. The difference in impedance values between concentrations is then used as a discerning factor for identification the degree of malignancy, for which an artificial neural network (ANN) is employed. A detailed study considering detection efficiency for this ANN revealed classification accuracy up to 95.0%, upon which this ANN model is transferred to a portable single board computer (SBC) along with other associated circuitry that could carry out the same classification at a nominal power consumption of 516.45 mW.
- 30 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (10) , 7522-7529
Development of a Low-Power Microcontroller-Based Wrist-Worn Device With Resource-Constrained Activity Detection Algorithm
This paper deals with the development of a resource constrained activity detection algorithm for microcontroller based wrist-worn devices. The various market available activity detection devices lack adequate agility and ease of use in certain applications, as they heavily rely upon computationally intensive algorithms to detect physical activity and step count. Therefore, by extension they always need to stay connected with a smart phone that can perform these computations. To address this problem, this work introduces a standalone wearable device with simplified algorithm for activity detection in a human being. The developed system consists of a Micro-electromechanical systems (MEMS) tri-axial accelerometer connected to a low power microcontroller with a wrist anchor-able form factor. The step detection algorithm uses a moving average threshold filter to detect the change in acceleration data to identify specific events. A detailed comparative study considering power consumption and the step detection made between the developed device (with resource constrained algorithm) against market available devices shows the average detection error of of the developed algorithm is approximately 2% under various test conditions (i.e. walking, fast walking and running) and has an accuracy of 94.96% for activity detection. This study reveals that the use of the proposed algorithm for activity detection not only brings down the cost of the overall device but also reduces the power consumption (<45.7 mW) with minimal covering size (12.56 cm2) for the wearable part that can extend the application area of such devices.
- 30 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (10) , 7522-7529
Development of a Low-Power Microcontroller-Based Wrist-Worn Device With Resource-Constrained Activity Detection Algorithm
This paper deals with the development of a resource constrained activity detection algorithm for microcontroller based wrist-worn devices. The various market available activity detection devices lack adequate agility and ease of use in certain applications, as they heavily rely upon computationally intensive algorithms to detect physical activity and step count. Therefore, by extension they always need to stay connected with a smart phone that can perform these computations. To address this problem, this work introduces a standalone wearable device with simplified algorithm for activity detection in a human being. The developed system consists of a Micro-electromechanical systems (MEMS) tri-axial accelerometer connected to a low power microcontroller with a wrist anchor-able form factor. The step detection algorithm uses a moving average threshold filter to detect the change in acceleration data to identify specific events. A detailed comparative study considering power consumption and the step detection made between the developed device (with resource constrained algorithm) against market available devices shows the average detection error of of the developed algorithm is approximately 2% under various test conditions (i.e. walking, fast walking and running) and has an accuracy of 94.96% for activity detection. This study reveals that the use of the proposed algorithm for activity detection not only brings down the cost of the overall device but also reduces the power consumption (<45.7 mW) with minimal covering size (12.56 cm2) for the wearable part that can extend the application area of such devices.