Arne Langhoff
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Arne Langhoff has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Diethelm Johannsmann
Institute of Physical Chemistry Clausthal University of Technology Clausthal‐Zellerfeld Germany
6 shared publications - Christian Leppin
Professorship of Electrochemical Technology Department of Chemistry Paderborn University Paderborn Germany
5 shared publications - Astrid Peschel
Institute of Physical Chemistry, Clausthal University of Technology, Arnold-Sommerfeld-Str. 4, 38678 Clausthal-Zellerfeld, Germany
2 shared publications - Sebastian Kruppert
Plant Biomechanics Group @ Botanic Garden, University Freiburg, Freiburg im Breisgau , 79104
2 shared publications - Thomas Speck
University of Freiburg
2 shared publications - Anna M. C. Maan
Polymer Science, Zernike Institute for Advanced Materials, University of Groningen, Nijenborgh 4, 9747 AG Groningen, The Netherlands
1 shared publication
Latest Publications
- Open Access
Rapid Solidification of Plant Latices from Campanula glomerata Driven by a Sudden Decrease in Hydrostatic Pressure
By monitoring the solidification of droplets of plant latices with a fast quartz crystal microbalance with dissipation monitoring (QCM-D), droplets from Campanula glomerata were found to solidify much faster than droplets from Euphorbia characias and also faster than droplets from all technical latices tested. A similar conclusion was drawn from optical videos, where the plants were injured and the milky fluid was stretched (sometimes forming fibers) after the cut. Rapid solidification cannot be explained with physical drying because physical drying is transport-limited and therefore is inherently slow. It can, however, be explained with coagulation being triggered by a sudden decrease in hydrostatic pressure. A mechanism based on a pressure drop is corroborated by optical videos of both plants being injured under water. While the liquid exuded by E. characias keeps streaming away, the liquid exuded by C. glomerata quickly forms a plug even under water. Presumably, the pressure drop causes an influx of serum into the laticifers. The serum, in turn, triggers a transition from a liquid–liquid phase separated state (an LLPS state) of a resin and hardener to a single-phase state. QCM measurements, optical videos, and cryo-SEM images suggest that LLPS plays a role in the solidification of C. glomerata.
Open AccessRapid Solidification of Plant Latices from Campanula glomerata Driven by a Sudden Decrease in Hydrostatic Pressure
By monitoring the solidification of droplets of plant latices with a fast quartz crystal microbalance with dissipation monitoring (QCM-D), droplets from Campanula glomerata were found to solidify much faster than droplets from Euphorbia characias and also faster than droplets from all technical latices tested. A similar conclusion was drawn from optical videos, where the plants were injured and the milky fluid was stretched (sometimes forming fibers) after the cut. Rapid solidification cannot be explained with physical drying because physical drying is transport-limited and therefore is inherently slow. It can, however, be explained with coagulation being triggered by a sudden decrease in hydrostatic pressure. A mechanism based on a pressure drop is corroborated by optical videos of both plants being injured under water. While the liquid exuded by E. characias keeps streaming away, the liquid exuded by C. glomerata quickly forms a plug even under water. Presumably, the pressure drop causes an influx of serum into the laticifers. The serum, in turn, triggers a transition from a liquid–liquid phase separated state (an LLPS state) of a resin and hardener to a single-phase state. QCM measurements, optical videos, and cryo-SEM images suggest that LLPS plays a role in the solidification of C. glomerata.
- Open Access
- 24 February 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Measurement of electrophoretic forces and the kinetics thereof with an AFM cantilever
AFM cantilevers were used to probe electrophoretic forces while switching an external electric field. As expected, the forces were in the range of a few 10´s of piconewtons. They could be easily resolved with the optical lever technique, provided that data were accumulated and averaged for a few minutes. The time resolution of the experiment was 200 microseconds. The kinetics were rather complicated. There was a fast movement of the negatively charged cantilever towards the positively charged electrode, which in most cases was not kinetically resolved and in other cases lasted a few milliseconds. This first step was followed by a reverse motion, which in most cases could be interpreted as a relaxation. The time scale of this motion roughly matched the time scale, over which the electric current through the electrodes decayed. The electric current was mostly due to double layer recharging, possibly accompanied by some charge transfer at the electrodes. The current caused a decay of the electric field at the cantilever, hence the decay of the cantilever deflection. Interestingly, the second stage occasionally drove the cantilever deflection to the opposite side. The second process in these cases overcompensated the first process, which is in conflict with the notion of this second process being entirely caused by a relaxation. The cantilever never came to rest over a few milliseconds. The origin of the slow movement in the final stage of the modulation cycle may be rooted in convection.
- 24 February 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessMeasurement of electrophoretic forces and the kinetics thereof with an AFM cantilever
AFM cantilevers were used to probe electrophoretic forces while switching an external electric field. As expected, the forces were in the range of a few 10´s of piconewtons. They could be easily resolved with the optical lever technique, provided that data were accumulated and averaged for a few minutes. The time resolution of the experiment was 200 microseconds. The kinetics were rather complicated. There was a fast movement of the negatively charged cantilever towards the positively charged electrode, which in most cases was not kinetically resolved and in other cases lasted a few milliseconds. This first step was followed by a reverse motion, which in most cases could be interpreted as a relaxation. The time scale of this motion roughly matched the time scale, over which the electric current through the electrodes decayed. The electric current was mostly due to double layer recharging, possibly accompanied by some charge transfer at the electrodes. The current caused a decay of the electric field at the cantilever, hence the decay of the cantilever deflection. Interestingly, the second stage occasionally drove the cantilever deflection to the opposite side. The second process in these cases overcompensated the first process, which is in conflict with the notion of this second process being entirely caused by a relaxation. The cantilever never came to rest over a few milliseconds. The origin of the slow movement in the final stage of the modulation cycle may be rooted in convection.
- Open Access
- 16 December 2024
- Published by MDPI AG in Preprints.org
Rapid Solidification of Plant Latices from Campanula glomerata Driven by a Sudden Decrease in Hydrostatic Pressure
Monitoring the solidification of droplets of plant latices with a fast quartz crystal microbalance with dissipation monitoring (QCM-D), droplets from Campanula glomerata were found to solidify much faster than droplets from Euphorbia characias and, also, faster than droplets from all technical latices tested. A similar conclusion is drawn from optical videos, where the plants were injured and the milky fluid was stretched into fibers after the cut. Rapid solidification cannot be explained with physical drying because physical drying is transport-limited and therefore is inherently slow. It can, however, be explained with coagulation being triggered by a sudden decrease in hydrostatic pressure. A mechanism based on a pressure drop is corroborated by optical videos of both plants being injured under water. While the liquid exuded by E. characias keeps streaming away, the liquid exuded by C. glomerata quickly forms a plug even under water. Presumably, the pressure drop causes an influx of serum into the laticifers. The serum, in turn, triggers a transition from liquid-liquid phase separated state (an LLPS state) of a resin and hardener to a single-phase state. QCM measurements, optical videos, and cryo-SEM images suggest that LLPS plays a role in the solidification of C. glomerata.
- 16 December 2024
- Published by MDPI AG in Preprints.org
Open AccessRapid Solidification of Plant Latices from Campanula glomerata Driven by a Sudden Decrease in Hydrostatic Pressure
Monitoring the solidification of droplets of plant latices with a fast quartz crystal microbalance with dissipation monitoring (QCM-D), droplets from Campanula glomerata were found to solidify much faster than droplets from Euphorbia characias and, also, faster than droplets from all technical latices tested. A similar conclusion is drawn from optical videos, where the plants were injured and the milky fluid was stretched into fibers after the cut. Rapid solidification cannot be explained with physical drying because physical drying is transport-limited and therefore is inherently slow. It can, however, be explained with coagulation being triggered by a sudden decrease in hydrostatic pressure. A mechanism based on a pressure drop is corroborated by optical videos of both plants being injured under water. While the liquid exuded by E. characias keeps streaming away, the liquid exuded by C. glomerata quickly forms a plug even under water. Presumably, the pressure drop causes an influx of serum into the laticifers. The serum, in turn, triggers a transition from liquid-liquid phase separated state (an LLPS state) of a resin and hardener to a single-phase state. QCM measurements, optical videos, and cryo-SEM images suggest that LLPS plays a role in the solidification of C. glomerata.
- Open Access
Effect of Noise on Determining Ultrathin-Film Parameters from QCM-D Data with the Viscoelastic Model
Quartz crystal microbalance with dissipation monitoring (QCM-D) is a well-established technique for studying soft films. It can provide gravimetric as well as nongravimetric information about a film, such as its thickness and mechanical properties. The interpretation of sets of overtone-normalized frequency shifts, ∆f/n, and overtone-normalized shifts in half-bandwidth, ΔΓ/n, provided by QCM-D relies on a model that, in general, contains five independent parameters that are needed to describe film thickness and frequency-dependent viscoelastic properties. Here, we examine how noise inherent in experimental data affects the determination of these parameters. There are certain conditions where noise prevents the reliable determination of film thickness and the loss tangent. On the other hand, we show that there are conditions where it is possible to determine all five parameters. We relate these conditions to the mathematical properties of the model in terms of simple conceptual diagrams that can help users understand the model’s behavior. Finally, we present new open source software for QCM-D data analysis written in Python, PyQTM.
Open AccessEffect of Noise on Determining Ultrathin-Film Parameters from QCM-D Data with the Viscoelastic Model
Quartz crystal microbalance with dissipation monitoring (QCM-D) is a well-established technique for studying soft films. It can provide gravimetric as well as nongravimetric information about a film, such as its thickness and mechanical properties. The interpretation of sets of overtone-normalized frequency shifts, ∆f/n, and overtone-normalized shifts in half-bandwidth, ΔΓ/n, provided by QCM-D relies on a model that, in general, contains five independent parameters that are needed to describe film thickness and frequency-dependent viscoelastic properties. Here, we examine how noise inherent in experimental data affects the determination of these parameters. There are certain conditions where noise prevents the reliable determination of film thickness and the loss tangent. On the other hand, we show that there are conditions where it is possible to determine all five parameters. We relate these conditions to the mathematical properties of the model in terms of simple conceptual diagrams that can help users understand the model’s behavior. Finally, we present new open source software for QCM-D data analysis written in Python, PyQTM.
- Top Cited PapersOpen Access
Studying Soft Interfaces with Shear Waves: Principles and Applications of the Quartz Crystal Microbalance (QCM)
The response of the quartz crystal microbalance (QCM, also: QCM-D for “QCM with Dissipation monitoring”) to loading with a diverse set of samples is reviewed in a consistent frame. After a brief introduction to the advanced QCMs, the governing equation (the small-load approximation) is derived. Planar films and adsorbates are modeled based on the acoustic multilayer formalism. In liquid environments, viscoelastic spectroscopy and high-frequency rheology are possible, even on layers with a thickness in the monolayer range. For particulate samples, the contact stiffness can be derived. Because the stress at the contact is large, the force is not always proportional to the displacement. Nonlinear effects are observed, leading to a dependence of the resonance frequency and the resonance bandwidth on the amplitude of oscillation. Partial slip, in particular, can be studied in detail. Advanced topics include structured samples and the extension of the small-load approximation to its tensorial version.
Top Cited PapersOpen AccessStudying Soft Interfaces with Shear Waves: Principles and Applications of the Quartz Crystal Microbalance (QCM)
The response of the quartz crystal microbalance (QCM, also: QCM-D for “QCM with Dissipation monitoring”) to loading with a diverse set of samples is reviewed in a consistent frame. After a brief introduction to the advanced QCMs, the governing equation (the small-load approximation) is derived. Planar films and adsorbates are modeled based on the acoustic multilayer formalism. In liquid environments, viscoelastic spectroscopy and high-frequency rheology are possible, even on layers with a thickness in the monolayer range. For particulate samples, the contact stiffness can be derived. Because the stress at the contact is large, the force is not always proportional to the displacement. Nonlinear effects are observed, leading to a dependence of the resonance frequency and the resonance bandwidth on the amplitude of oscillation. Partial slip, in particular, can be studied in detail. Advanced topics include structured samples and the extension of the small-load approximation to its tensorial version.
- Open Access
A Quartz Crystal Microbalance, Which Tracks Four Overtones in Parallel with a Time Resolution of 10 Milliseconds: Application to Inkjet Printing
A quartz crystal microbalance (QCM) is described, which simultaneously determines resonance frequency and bandwidth on four different overtones. The time resolution is 10 milliseconds. This fast, multi-overtone QCM is based on multi-frequency lockin amplification. Synchronous interrogation of overtones is needed, when the sample changes quickly and when information on the sample is to be extracted from the comparison between overtones. The application example is thermal inkjet-printing. At impact, the resonance frequencies change over a time shorter than 10 milliseconds. There is a further increase in the contact area, evidenced by an increasing common prefactor to the shifts in frequency, Δf, and half-bandwidth, ΔΓ. The ratio ΔΓ/(−Δf), which quantifies the energy dissipated per time and unit area, decreases with time. Often, there is a fast initial decrease, lasting for about 100 milliseconds, followed by a slower decrease, persisting over the entire drying time (a few seconds). Fitting the overtone dependence of Δf(n) and ΔΓ(n) with power laws, one finds power-law exponents of about 1/2, characteristic of semi-infinite Newtonian liquids. The power-law exponents corresponding to Δf(n) slightly increase with time. The decrease of ΔΓ/(−Δf) and the increase of the exponents are explained by evaporation and formation of a solid film at the resonator surface.
Open AccessA Quartz Crystal Microbalance, Which Tracks Four Overtones in Parallel with a Time Resolution of 10 Milliseconds: Application to Inkjet Printing
A quartz crystal microbalance (QCM) is described, which simultaneously determines resonance frequency and bandwidth on four different overtones. The time resolution is 10 milliseconds. This fast, multi-overtone QCM is based on multi-frequency lockin amplification. Synchronous interrogation of overtones is needed, when the sample changes quickly and when information on the sample is to be extracted from the comparison between overtones. The application example is thermal inkjet-printing. At impact, the resonance frequencies change over a time shorter than 10 milliseconds. There is a further increase in the contact area, evidenced by an increasing common prefactor to the shifts in frequency, Δf, and half-bandwidth, ΔΓ. The ratio ΔΓ/(−Δf), which quantifies the energy dissipated per time and unit area, decreases with time. Often, there is a fast initial decrease, lasting for about 100 milliseconds, followed by a slower decrease, persisting over the entire drying time (a few seconds). Fitting the overtone dependence of Δf(n) and ΔΓ(n) with power laws, one finds power-law exponents of about 1/2, characteristic of semi-infinite Newtonian liquids. The power-law exponents corresponding to Δf(n) slightly increase with time. The decrease of ΔΓ/(−Δf) and the increase of the exponents are explained by evaporation and formation of a solid film at the resonator surface.