Shuo Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shuo Han has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Bart Julien Dewancker
Department of Architecture, The University of Kitakyushu, Kitakyushu, Japan
3 shared publications - Xingbo Yao
Faculty of Environmental Engineering, The University of Kitakyushu, Kitakyushu 808-0135, Japan
3 shared publications - Juan Xu
School of Architecture, Chang’an University, Xi’an 710064, China
1 shared publication - Yuang Guo
School of Architecture and Urban Planning, Qingdao University of Technology, Qingdao 266033, China
1 shared publication
Latest Publications
- Open Access
- 16 August 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (16) , 8644
Wind Environment Simulation Accuracy in Traditional Villages with Complex Layouts Based on CFD
Using wind speed, wind direction, and turbulence intensity values as evaluation indicators, the ventilation performance of villages with complex building layouts was studied. We used the SKE, RNG, and RKE solvers in CFD-3D steady-state Reynolds-averaged Navier–Stokes (RANS) to simulate the wind environment of a village. The findings show that for the simulation of rural wind environments with complex building layouts, steady-state simulation solvers need to be evaluated in detail to verify their accuracy. In this study, a village with a complex architectural layout in Southern Shaanxi, China, was taken as the research object, and three steady-state simulation solvers were used to evaluate the ventilation performance of the village. The simulated data were compared with the measured data to find the most suitable solver for this kind of village wind environment simulation. The results show that for the simulation of the village wind environment with a complex building layout, the RNG simulation results have the lowest reliability among the three steady-state solvers. The reliability of wind speed distribution and turbulence intensity distribution are 0.7881 and 0.2473, respectively. However, the wind speed and turbulence intensity values obtained by the SKE solver are the closest to the measured values, which are 0.8625 and 0.9088, respectively. Therefore, for villages with complex building layouts, the SKE solver should be the first choice for simulating wind environment distribution. When using the RNG solver, the overall turbulence intensity value obtained is higher than the measured value. The average deviation between the simulated data and SKE and RKE at a height of 1.7 m is 42.61%. The main reason for this is that RNG overestimates the vortices and underestimates the airflow rate in the building intervals.
- 16 August 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (16) , 8644
Open AccessWind Environment Simulation Accuracy in Traditional Villages with Complex Layouts Based on CFD
Using wind speed, wind direction, and turbulence intensity values as evaluation indicators, the ventilation performance of villages with complex building layouts was studied. We used the SKE, RNG, and RKE solvers in CFD-3D steady-state Reynolds-averaged Navier–Stokes (RANS) to simulate the wind environment of a village. The findings show that for the simulation of rural wind environments with complex building layouts, steady-state simulation solvers need to be evaluated in detail to verify their accuracy. In this study, a village with a complex architectural layout in Southern Shaanxi, China, was taken as the research object, and three steady-state simulation solvers were used to evaluate the ventilation performance of the village. The simulated data were compared with the measured data to find the most suitable solver for this kind of village wind environment simulation. The results show that for the simulation of the village wind environment with a complex building layout, the RNG simulation results have the lowest reliability among the three steady-state solvers. The reliability of wind speed distribution and turbulence intensity distribution are 0.7881 and 0.2473, respectively. However, the wind speed and turbulence intensity values obtained by the SKE solver are the closest to the measured values, which are 0.8625 and 0.9088, respectively. Therefore, for villages with complex building layouts, the SKE solver should be the first choice for simulating wind environment distribution. When using the RNG solver, the overall turbulence intensity value obtained is higher than the measured value. The average deviation between the simulated data and SKE and RKE at a height of 1.7 m is 42.61%. The main reason for this is that RNG overestimates the vortices and underestimates the airflow rate in the building intervals.
- Open Access
- 18 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (12) , 5636
Study on the Combined Effect of Multiple Passive Energy-Saving Methods for Rural Houses with Cold Alleys
China’s rural houses are mostly courtyard-style independent houses. Such houses have certain characteristics, e.g., small mutual influences between houses, strong transformation flexibility, and an easier approach to using the natural environment to develop passive energy-saving characteristics. Therefore, rural houses have large energy-saving potential. In this study, for the first time, the cold alleys between buildings were used as an energy source for passive cooling and ventilation. Traditional houses in Shuhe, China, were used as a case study. The cold alleys in the settlements were used to compensate for the natural conditions in summer, and the cold air in the cold alley was introduced into each room using hot-press ventilation and by employing an accumulation effect from a corresponding patio. The room was ventilated and cooled, and air ducts were used to connect the rooms on both sides of the patio to improve the cooling efficiency. The research variables included the existence or non-existence of wall heat radiation (WHR), and the importance and influence of the WHR on the indoor conditions were verified. The cold air trapped in the new system formed an air partition wall, effectively blocking the direct influence of solar radiation on the room, reducing the heat transfer rate of the residential wall, and consuming part of the heat. In winter, based on using air ducts as supporting members, a glass roof was added to the patio, which improved the heat storage capacity of the patio and turned it into a constant-temperature heater for heating the building interior. Based on calculations, in the new system without WHR, the annual cooling load reduction was 55,417.33 kWh. With WHR, the annual cooling load reduction was 28,537.57 kWh. The annual cooling load of the air insulation wall of the new system was reduced to 1133.7 kWh. In winter, using the glass roof to increase the heat storage capacity of the patio reduced the heating load to 54,537.78 kWh.
- 18 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (12) , 5636
Open AccessStudy on the Combined Effect of Multiple Passive Energy-Saving Methods for Rural Houses with Cold Alleys
China’s rural houses are mostly courtyard-style independent houses. Such houses have certain characteristics, e.g., small mutual influences between houses, strong transformation flexibility, and an easier approach to using the natural environment to develop passive energy-saving characteristics. Therefore, rural houses have large energy-saving potential. In this study, for the first time, the cold alleys between buildings were used as an energy source for passive cooling and ventilation. Traditional houses in Shuhe, China, were used as a case study. The cold alleys in the settlements were used to compensate for the natural conditions in summer, and the cold air in the cold alley was introduced into each room using hot-press ventilation and by employing an accumulation effect from a corresponding patio. The room was ventilated and cooled, and air ducts were used to connect the rooms on both sides of the patio to improve the cooling efficiency. The research variables included the existence or non-existence of wall heat radiation (WHR), and the importance and influence of the WHR on the indoor conditions were verified. The cold air trapped in the new system formed an air partition wall, effectively blocking the direct influence of solar radiation on the room, reducing the heat transfer rate of the residential wall, and consuming part of the heat. In winter, based on using air ducts as supporting members, a glass roof was added to the patio, which improved the heat storage capacity of the patio and turned it into a constant-temperature heater for heating the building interior. Based on calculations, in the new system without WHR, the annual cooling load reduction was 55,417.33 kWh. With WHR, the annual cooling load reduction was 28,537.57 kWh. The annual cooling load of the air insulation wall of the new system was reduced to 1133.7 kWh. In winter, using the glass roof to increase the heat storage capacity of the patio reduced the heating load to 54,537.78 kWh.
- Open Access
- 20 October 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (20) , 8687
Study on Passive Ventilation and Cooling Strategies for Cold Lanes and Courtyard Houses—A Case Study of Rural Traditional Village in Shaanxi, China
China’s research on and specific implementation of energy saving for buildings are mainly concentrated in urban areas, but according to 2016 statistics, the rural population accounts for 42.65% of the total population, so rural housing has considerable energy-saving potential. However, the degree of attention to the energy consumption of rural houses needs to be improved. Regarding the research on and implementation of passive energy-saving strategies for residences, compared with centralized urban high-rise residences, rural residences mainly have independent courtyards, with a flexible layout and easier transformation. In this study, a system that uses the common cold lanes in traditional villages and buildings’ exterior walls was constructed, and the indoor spaces of courtyard buildings in southern Shaanxi were completely passively cooled in summer. This system can be completely separated from the supply of artificial energy by relying on the accumulation and buoyancy effects of air in patios and cold lanes and the hot-pressure ventilation in buildings to cool the buildings and greatly improve indoor ventilation efficiency. As the building is ventilated and cooled, the air wall formed in the system can effectively prevent direct contact between the outdoor and indoor temperatures and reduce the impact of thermal wall radiation on the interior. In previous studies on the passive design of courtyard houses, scholars considered the effect of thermal wall radiation on indoor temperature in simulations. Therefore, in this study, we also separately calculated whether to consider the difference between the situation with and without wall heat radiation (WHR) when simulating thermal conversion. The final results show that when the cooling system was adopted, the annual cooling load of the whole building was 4786.494 kW·h without WHR. However, with WHR, the cooling load reduction was 2989.128 kW·h, a difference of 1797.336 kW·h.
- 20 October 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (20) , 8687
Open AccessStudy on Passive Ventilation and Cooling Strategies for Cold Lanes and Courtyard Houses—A Case Study of Rural Traditional Village in Shaanxi, China
China’s research on and specific implementation of energy saving for buildings are mainly concentrated in urban areas, but according to 2016 statistics, the rural population accounts for 42.65% of the total population, so rural housing has considerable energy-saving potential. However, the degree of attention to the energy consumption of rural houses needs to be improved. Regarding the research on and implementation of passive energy-saving strategies for residences, compared with centralized urban high-rise residences, rural residences mainly have independent courtyards, with a flexible layout and easier transformation. In this study, a system that uses the common cold lanes in traditional villages and buildings’ exterior walls was constructed, and the indoor spaces of courtyard buildings in southern Shaanxi were completely passively cooled in summer. This system can be completely separated from the supply of artificial energy by relying on the accumulation and buoyancy effects of air in patios and cold lanes and the hot-pressure ventilation in buildings to cool the buildings and greatly improve indoor ventilation efficiency. As the building is ventilated and cooled, the air wall formed in the system can effectively prevent direct contact between the outdoor and indoor temperatures and reduce the impact of thermal wall radiation on the interior. In previous studies on the passive design of courtyard houses, scholars considered the effect of thermal wall radiation on indoor temperature in simulations. Therefore, in this study, we also separately calculated whether to consider the difference between the situation with and without wall heat radiation (WHR) when simulating thermal conversion. The final results show that when the cooling system was adopted, the annual cooling load of the whole building was 4786.494 kW·h without WHR. However, with WHR, the cooling load reduction was 2989.128 kW·h, a difference of 1797.336 kW·h.