Alba María Fernández-Sotillo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alba María Fernández-Sotillo has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Paloma Ferreira-Aparicio
Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT)
4 shared publications E. García-Toraño
CIEMAT, Laboratorio de Metrología de Radiaciones Ionizantes (LMRI) 1 , Avenida Complutense 40, 28040 Madrid, Spain
2 shared publications- Víctor H. Elvira
Université Paris‐Saclay, CEA, LIST, Laboratoire National Henri Becquerel (LNE‐LNHB) Palaiseau France
2 shared publications Antonio M. Chaparro
Research Center for Energy, Environment and Technology—CIEMAT, Madrid, Spain
1 shared publicationJulio J. Conde
Research Center for Energy, Environment and Technology—CIEMAT, Madrid, Spain
1 shared publicationM. Antonia Folgado
Research Center for Energy, Environment and Technology—CIEMAT, Madrid, Spain
1 shared publication
Latest Publications
- Open Access
Passive Regulation of the Water Content at the Anode Chamber under Dead-Ended Conditions: Innovative Design of an Air-Breathing Proton Exchange Membrane Fuel Cell
A passive regulation system for the water content has been developed and evaluated for a proton exchange membrane fuel cell. It is of particular relevance for micro-fuel cells, whose volume, weight and extra-consumption of fuel and power for subsidiary components must be kept to a minimum. This solution consists of a self-regulating humidity system implemented at the anode chamber that allows free water exchange with the environment through the surface of a gas-tight membrane. The micro-fuel cell, which is designed according to the patent WO2015025070A1, has been assembled and operated under completely passive conditions. The behavior of the anode humidity regulation system has been analyzed externally and in situ. The external part of the anode, where the humidity exchange with the environment takes place, has been isolated in a closed chamber and a hygrometer has been used to register the relative humidity in the zone near to the water exchange film. The results obtained from the operation of this innovative system are discussed in the light of the water permeation behavior of different Nafion membranes.
Open AccessPassive Regulation of the Water Content at the Anode Chamber under Dead-Ended Conditions: Innovative Design of an Air-Breathing Proton Exchange Membrane Fuel Cell
A passive regulation system for the water content has been developed and evaluated for a proton exchange membrane fuel cell. It is of particular relevance for micro-fuel cells, whose volume, weight and extra-consumption of fuel and power for subsidiary components must be kept to a minimum. This solution consists of a self-regulating humidity system implemented at the anode chamber that allows free water exchange with the environment through the surface of a gas-tight membrane. The micro-fuel cell, which is designed according to the patent WO2015025070A1, has been assembled and operated under completely passive conditions. The behavior of the anode humidity regulation system has been analyzed externally and in situ. The external part of the anode, where the humidity exchange with the environment takes place, has been isolated in a closed chamber and a hygrometer has been used to register the relative humidity in the zone near to the water exchange film. The results obtained from the operation of this innovative system are discussed in the light of the water permeation behavior of different Nafion membranes.
- 1 October 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (10) , 103304
Design and optimization of a proportional counter for the absolute determination of low-energy x-ray emission rates
We recently presented the construction of a proportional counter for the absolute measurement of low-energy x-ray emission rates. Its main features were presented in a previous study, along with the testing of its performance as an absolute technique. Full details on its design, construction, and characterization processes are given in this paper. First, the analytical calculations and Monte Carlo simulations that led to the choice of optimal dimensions will be presented, followed by the study of the charge creation and the modeling of the electric field that confirmed that the criteria for a reproducible charge multiplication are met. Afterward, details on the electronics and gas control system will be provided. The dimensional measurements for the accurate determination of the solid angle will be described in detail. Special emphasis will be placed on the production of the detector window, which was made of reduced graphene oxide instead of beryllium. Some tests on the operation of the counter will be presented, namely, the measurement of spectra of several radionuclides that emit x-rays between 3 keV and 9 keV, as well as the fluorescence spectrum of chlorine, at 2.6 keV. A brief explanation of the determination of emission rates will be given, including the approach adopted for the treatment of the escape-peak area. The emission rate measured with the proportional counter was converted into activity concentration using the emission probabilities from the bibliography, in order to compare the results with those obtained by liquid scintillation counting, and both results were found to be in good agreement.
- 1 October 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (10) , 103304
Design and optimization of a proportional counter for the absolute determination of low-energy x-ray emission rates
We recently presented the construction of a proportional counter for the absolute measurement of low-energy x-ray emission rates. Its main features were presented in a previous study, along with the testing of its performance as an absolute technique. Full details on its design, construction, and characterization processes are given in this paper. First, the analytical calculations and Monte Carlo simulations that led to the choice of optimal dimensions will be presented, followed by the study of the charge creation and the modeling of the electric field that confirmed that the criteria for a reproducible charge multiplication are met. Afterward, details on the electronics and gas control system will be provided. The dimensional measurements for the accurate determination of the solid angle will be described in detail. Special emphasis will be placed on the production of the detector window, which was made of reduced graphene oxide instead of beryllium. Some tests on the operation of the counter will be presented, namely, the measurement of spectra of several radionuclides that emit x-rays between 3 keV and 9 keV, as well as the fluorescence spectrum of chlorine, at 2.6 keV. A brief explanation of the determination of emission rates will be given, including the approach adopted for the treatment of the escape-peak area. The emission rate measured with the proportional counter was converted into activity concentration using the emission probabilities from the bibliography, in order to compare the results with those obtained by liquid scintillation counting, and both results were found to be in good agreement.
- 28 September 2020
- Published by American Chemical Society (ACS) in ACS Applied Energy Materials
- Vol. 3 (10) , 10023-10036
Continuous Graphene-like Layers Formed on Copper Substrates by Graphene Oxide Self-Assembly and Reduction
- 28 September 2020
- Published by American Chemical Society (ACS) in ACS Applied Energy Materials
- Vol. 3 (10) , 10023-10036
Continuous Graphene-like Layers Formed on Copper Substrates by Graphene Oxide Self-Assembly and Reduction
- 11 September 2020
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 3 (10) , 9862-9869
Patterning Large Free-Standing Reduced Graphene Oxide Films Assisted by Open-Area Copper Substrates for Graphene Drums
- 11 September 2020
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 3 (10) , 9862-9869
Patterning Large Free-Standing Reduced Graphene Oxide Films Assisted by Open-Area Copper Substrates for Graphene Drums
- 1 June 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 160, 109113
Absolute determination of low-energy X-ray emission rates with a proportional counter
- 1 June 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 160, 109113
Absolute determination of low-energy X-ray emission rates with a proportional counter
- 10 August 2018
- Published by Elsevier
- p. 193-216
Research trends