Volker Brüser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Volker Brüser has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Alla Zak
Faculty of Sciences, Holon Institute of Technology, Holon 5810201, Israel
2 shared publications Jan Hummel
2 shared publicationsJuergen F. Kolb
Leibniz Institute for Plasma Science and Technology (INP), Greifswald, Germany
2 shared publications- Juergen F. Kolb
Leibniz Institute for Plasma Science and Technology
2 shared publications - Ronny Brandenburg
Leibniz Institute for Plasma Science and Technology, Felix-Hausdorff-Str. 2, 17489 Greifswald, Germany
2 shared publications Sepideh Mousazadeh Borghei
2 shared publications
Latest Publications
- Open Access
- 26 November 2026
- Published by Elsevier in Journal of CO2 Utilization
- Vol. 114
Dry reforming of methane in AC gliding arc plasma: An exploratory study of the effects of feed gas composition, flow rate and high-voltage amplitude
- 26 November 2026
- Published by Elsevier in Journal of CO2 Utilization
- Vol. 114
Open AccessDry reforming of methane in AC gliding arc plasma: An exploratory study of the effects of feed gas composition, flow rate and high-voltage amplitude
- Open Access
- 20 September 2026
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 133, 108065
Ultrasound-enhanced hydrogen peroxide generation of microwave plasma discharges in conductive aqueous solutions
- 20 September 2026
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 133, 108065
Open AccessUltrasound-enhanced hydrogen peroxide generation of microwave plasma discharges in conductive aqueous solutions
- Open Access
- 25 August 2026
- Published by Elsevier in SSRN Electronic Journal
Dry Reforming of Methane in AC Gliding Arc Plasma: An Explorative Study of Gas Composition, Flow Rate and Voltage Amplitude
Atmospheric-pressure gliding arc discharge is investigated for plasma-assisted CO2 dry reforming of methane, focusing on the effects of voltage amplitude, gas flow rate (2–10 L/min), and CH₄ fraction (0–80%) on discharge behavior, reactant conversion, and syngas production. Electrical characterization reveals a strong dependence of discharge stability and power deposition on gas composition and flow rate, with lower CO₂ fractions and moderate flow rates promoting more regular discharge operation. The experimental results are further interpreted using thermodynamic calculations and a simplified atomic-balance analysis. Maximum estimated conversions of ~21% for CO₂ and ~37% for CH₄ are achieved at a specific energy input of 4.8 eV/molecule. At an equimolar CH₄/CO₂ feed, an H₂/CO ratio of 0.96 ± 0.10 is obtained. The highest CO energy yield is approximately 91 g/kWh at 33% CH₄, whereas the H₂ energy yield increases with CH₄ fraction, reaching ~7 g/kWh at a 1:4 CO₂/CH₄ ratio. The most favorable energetic performance is observed at intermediate CH₄ fractions (~35–50%, depending on flow rate), where relatively high reactant conversion coincides with reduced discharge power and enhanced energy yield. Increasing CH₄ content also suppresses oxygen-containing products and alters the by-product distribution. Stoichiometric analysis further shows that the occurrence and position of the maximum CO concentration are governed by the stoichiometric ratios of the dominant gross reactions. These findings clarify the coupled effects of feed composition, flow conditions, and discharge characteristics on plasma-assisted CO₂/CH₄ conversion.
- 25 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDry Reforming of Methane in AC Gliding Arc Plasma: An Explorative Study of Gas Composition, Flow Rate and Voltage Amplitude
Atmospheric-pressure gliding arc discharge is investigated for plasma-assisted CO2 dry reforming of methane, focusing on the effects of voltage amplitude, gas flow rate (2–10 L/min), and CH₄ fraction (0–80%) on discharge behavior, reactant conversion, and syngas production. Electrical characterization reveals a strong dependence of discharge stability and power deposition on gas composition and flow rate, with lower CO₂ fractions and moderate flow rates promoting more regular discharge operation. The experimental results are further interpreted using thermodynamic calculations and a simplified atomic-balance analysis. Maximum estimated conversions of ~21% for CO₂ and ~37% for CH₄ are achieved at a specific energy input of 4.8 eV/molecule. At an equimolar CH₄/CO₂ feed, an H₂/CO ratio of 0.96 ± 0.10 is obtained. The highest CO energy yield is approximately 91 g/kWh at 33% CH₄, whereas the H₂ energy yield increases with CH₄ fraction, reaching ~7 g/kWh at a 1:4 CO₂/CH₄ ratio. The most favorable energetic performance is observed at intermediate CH₄ fractions (~35–50%, depending on flow rate), where relatively high reactant conversion coincides with reduced discharge power and enhanced energy yield. Increasing CH₄ content also suppresses oxygen-containing products and alters the by-product distribution. Stoichiometric analysis further shows that the occurrence and position of the maximum CO concentration are governed by the stoichiometric ratios of the dominant gross reactions. These findings clarify the coupled effects of feed composition, flow conditions, and discharge characteristics on plasma-assisted CO₂/CH₄ conversion.
- Open Access
- 12 September 2025
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 58 (37) , 375204
Experimental study and optimization of a microwave plasma biomass pretreatment using highly viscous sodium carboxymethyl cellulose solutions
A recently proposed pulsed in-liquid microwave plasma pretreatment aiming for biomass disintegration and methane yield enhancement in subsequent anaerobic digestion was further studied and optimized experimentally. A water-based, transparent, highly viscous, sodium carboxylmethyl cellulose solution was used as the treatment model and enabled a systematic quantification of the ignitability of the discharge depending on operational, geometric and substrate parameters. Higher conductivity and initial viscosity along with more powerful pulses and a small microwave antenna cross section promoted the built-up of an initial vapor bubble and hence a fast, efficient and reliable plasma ignition. The observed large viscosity reduction of the model indicated its disintegration and was found to originate from the production of hydrogen peroxide and subsequent advanced oxidation processes. The release of tungsten, copper and zinc due to erosion of the microwave antenna led to additional catalytic effects. Subsequently, the geometry of the coaxial antenna and the shape of the MW pulses were optimized for the most effective and energy-efficient disintegration of the cellulose model, which aligned with the most efficient ignition and hydrogen peroxide production. The best-performing configuration compromised the newly introduced small tungsten coaxial antenna and microwave pulses of 2 kW and 4.6 ms power and length, respectively (10% duty cycle). These findings represent not only an improved understanding of the proposed plasma biomass pretreatment, but also directly led to an improved technical implementation. A sophisticated application on actual biomass substrates in future work was therefore prepared.
- 12 September 2025
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 58 (37) , 375204
Open AccessExperimental study and optimization of a microwave plasma biomass pretreatment using highly viscous sodium carboxymethyl cellulose solutions
A recently proposed pulsed in-liquid microwave plasma pretreatment aiming for biomass disintegration and methane yield enhancement in subsequent anaerobic digestion was further studied and optimized experimentally. A water-based, transparent, highly viscous, sodium carboxylmethyl cellulose solution was used as the treatment model and enabled a systematic quantification of the ignitability of the discharge depending on operational, geometric and substrate parameters. Higher conductivity and initial viscosity along with more powerful pulses and a small microwave antenna cross section promoted the built-up of an initial vapor bubble and hence a fast, efficient and reliable plasma ignition. The observed large viscosity reduction of the model indicated its disintegration and was found to originate from the production of hydrogen peroxide and subsequent advanced oxidation processes. The release of tungsten, copper and zinc due to erosion of the microwave antenna led to additional catalytic effects. Subsequently, the geometry of the coaxial antenna and the shape of the MW pulses were optimized for the most effective and energy-efficient disintegration of the cellulose model, which aligned with the most efficient ignition and hydrogen peroxide production. The best-performing configuration compromised the newly introduced small tungsten coaxial antenna and microwave pulses of 2 kW and 4.6 ms power and length, respectively (10% duty cycle). These findings represent not only an improved understanding of the proposed plasma biomass pretreatment, but also directly led to an improved technical implementation. A sophisticated application on actual biomass substrates in future work was therefore prepared.
- 24 December 2024
- Published by Elsevier in Chemical Engineering Journal
- Vol. 506
Thermodynamic description of CO2 conversion by a dielectric barrier discharge process
- 24 December 2024
- Published by Elsevier in Chemical Engineering Journal
- Vol. 506
Thermodynamic description of CO2 conversion by a dielectric barrier discharge process
- Open Access
Plane Parallel Barrier Discharges for Carbon Dioxide Splitting: Influence of Discharge Arrangement on Carbon Monoxide Formation
A planar volume dielectric barrier discharge (DBD) in pure carbon dioxide (CO2) for the formation of carbon monoxide (CO) is examined by combined electrical and CO density measurements. The influence of the type of electrode, the barrier material, the barrier thickness, and the discharge gap on the plasma power and the CO formation is analyzed systematically. The electrical characterization by means of charge-voltage plots is based on the simplest equivalent circuit model of DBDs, extended by the so-called partial surface discharge effect and the presence of parallel parasitic capacitances. The stackable discharge arrangement in this study enables one to elucidate the influence of parasitic capacitances, which can be overlooked in the application of such plasma sources. The determination of the discharge voltage from charge-voltage plots and the validity of the so-called Manley power equation are revised by taking into account non-uniform coverage as well as parasitic capacitances. The energy yield () of CO is analyzed and compared with the literature. No correlations of with the mean reduced electric field strength or the geometric parameters of the DBD arrangement are observed.Open AccessPlane Parallel Barrier Discharges for Carbon Dioxide Splitting: Influence of Discharge Arrangement on Carbon Monoxide Formation
A planar volume dielectric barrier discharge (DBD) in pure carbon dioxide (CO2) for the formation of carbon monoxide (CO) is examined by combined electrical and CO density measurements. The influence of the type of electrode, the barrier material, the barrier thickness, and the discharge gap on the plasma power and the CO formation is analyzed systematically. The electrical characterization by means of charge-voltage plots is based on the simplest equivalent circuit model of DBDs, extended by the so-called partial surface discharge effect and the presence of parallel parasitic capacitances. The stackable discharge arrangement in this study enables one to elucidate the influence of parasitic capacitances, which can be overlooked in the application of such plasma sources. The determination of the discharge voltage from charge-voltage plots and the validity of the so-called Manley power equation are revised by taking into account non-uniform coverage as well as parasitic capacitances. The energy yield () of CO is analyzed and compared with the literature. No correlations of with the mean reduced electric field strength or the geometric parameters of the DBD arrangement are observed. - Open Access
- 3 March 2023
- Published by Springer Nature in The European Physical Journal D
- Vol. 77 (3) , 1-13
Polarity dependence of CO2 conversion in nanosecond pulsed large gap dielectric barrier discharges
The splitting of carbon dioxide was investigated for a coaxial dielectric barrier discharge, which was operated with nanosecond high-voltage pulses of 500 ns and amplitudes up to 20 kV at ambient temperature and atmospheric pressure. A non-thermal plasma could be established across a gap distance of 4 mm and a length of 90 mm for gas flows of 30–210 sccm of pure CO2 and with admixtures of Argon. The application of high-voltage pulses of either positive or negative polarity resulted in distinct differences in effective conversion and CO production. The highest observed conversion of 6.6%, corresponding to a CO production of 7%, was achieved for positive high-voltage pulses of 20 kV that were applied with a repetition rate of 3 kHz for a ratio of CO2:Ar of 1:2 at a flow rate of 30 sccm. Conversely, an operation with negative high-voltage pulses, for otherwise the same operating parameters, resulted in an effective conversion of only 5.3% and CO production of 5.4%. The corresponding conversion rates for specific energy input (SEI), concerning different operating parameters, could be related to reaction enthalpies that were calculated from thermodynamic functions. The differences in polarity were associated with discharge characteristics, i.e., plasmas appeared more filamentary for positive high-voltage pulses. In this case, a visible plasma could also be established for much lower pulse amplitudes. Graphical Abstract
- 3 March 2023
- Published by Springer Nature in The European Physical Journal D
- Vol. 77 (3) , 1-13
Open AccessPolarity dependence of CO2 conversion in nanosecond pulsed large gap dielectric barrier discharges
The splitting of carbon dioxide was investigated for a coaxial dielectric barrier discharge, which was operated with nanosecond high-voltage pulses of 500 ns and amplitudes up to 20 kV at ambient temperature and atmospheric pressure. A non-thermal plasma could be established across a gap distance of 4 mm and a length of 90 mm for gas flows of 30–210 sccm of pure CO2 and with admixtures of Argon. The application of high-voltage pulses of either positive or negative polarity resulted in distinct differences in effective conversion and CO production. The highest observed conversion of 6.6%, corresponding to a CO production of 7%, was achieved for positive high-voltage pulses of 20 kV that were applied with a repetition rate of 3 kHz for a ratio of CO2:Ar of 1:2 at a flow rate of 30 sccm. Conversely, an operation with negative high-voltage pulses, for otherwise the same operating parameters, resulted in an effective conversion of only 5.3% and CO production of 5.4%. The corresponding conversion rates for specific energy input (SEI), concerning different operating parameters, could be related to reaction enthalpies that were calculated from thermodynamic functions. The differences in polarity were associated with discharge characteristics, i.e., plasmas appeared more filamentary for positive high-voltage pulses. In this case, a visible plasma could also be established for much lower pulse amplitudes. Graphical Abstract
- Open Access
- 11 August 2021
- Published by IWA Publishing in Water Science & Technology
- Vol. 84 (5) , 1293-1301
Degradation of glyphosate in water by the application of surface corona discharges
Glyphosate (GLP) is one of the most widely applied herbicides, and is found ubiquitously in the environment. The removal of glyphosate from waste water and soil is challenging and can be achieved with chemical or biological methods, which, nevertheless, suffer from different disadvantages. The application of a physical plasma for the removal of GLP in water was examined by the application of surface corona discharges in a wire-to-cylinder setup filled with argon. The plasma was ignited at the liquid surface without any additives. By applying a photometric method, GLP was detected after derivatisation with fluorenyl methoxycarbonyl chloride, whereas phosphate was determined with ammonium molybdate. A GLP degradation rate of 90.8% could be achieved within a treatment time of 30 minutes with an estimated energy efficiency of 0.32 g/kWh.
- 11 August 2021
- Published by IWA Publishing in Water Science & Technology
- Vol. 84 (5) , 1293-1301
Open AccessDegradation of glyphosate in water by the application of surface corona discharges
Glyphosate (GLP) is one of the most widely applied herbicides, and is found ubiquitously in the environment. The removal of glyphosate from waste water and soil is challenging and can be achieved with chemical or biological methods, which, nevertheless, suffer from different disadvantages. The application of a physical plasma for the removal of GLP in water was examined by the application of surface corona discharges in a wire-to-cylinder setup filled with argon. The plasma was ignited at the liquid surface without any additives. By applying a photometric method, GLP was detected after derivatisation with fluorenyl methoxycarbonyl chloride, whereas phosphate was determined with ammonium molybdate. A GLP degradation rate of 90.8% could be achieved within a treatment time of 30 minutes with an estimated energy efficiency of 0.32 g/kWh.
- Open Access
- 21 October 2020
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 7 (4) , 041401
Cathodoluminescence in single and multiwall WS2 nanotubes: Evidence for quantum confinement and strain effect
For nanoparticles with sub-10 nm diameter, the electronic bandgap becomes size dependent due to quantum confinement; this, in turn, affects their electro-optical properties. Thereby, MoS2 and WS2 monolayers acquire luminescent capability, due to the confinement-induced indirect-to-direct bandgap transition. Rolling up of individual layers results in single wall inorganic nanotubes (SWINTs). Up to the present study, their luminescence properties were expected to be auspicious but were limited to theoretical investigations only, due to the scarcity of SWINTs and the difficulties in handling them. By optimizing the conditions in the plasma reactor, relatively high yields of WS2 SWINTs 3–7 nm in diameter were obtained in this work, compared to previous reports. A correlative approach, transmission electron microscopy coupled with a scanning electron microscope, was adapted to overcome handling obstacles and for testing individual nanotubes by low-temperature cathodoluminescence. Clear cathodoluminescence spectra were obtained from WS2-SWINTs and compared with those of WS2 multiwall nanotubes and the corresponding bulk material. Uniquely, the optical properties of INTs acquired from cathodoluminescence were governed by the opposite impact from quantum size effect and strain in the bent triple S-W-S layers. The experimental findings were confirmed by the Density Functional and Time-Dependent Density Functional theoretical modeling of monolayer and bilayer nanotubes of different chiralities and diameters. This study provides experimental evidence of the quantum confinement effect in WS2 SWINTs akin to WS2 monolayer. The ability to tune the electronic structure with morphology or number of layers may be exploited toward photoelectrochemical water splitting with WS2 catalysts, devising field effect transistors, photodetectors, and so on.
- 21 October 2020
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 7 (4) , 041401
Open AccessCathodoluminescence in single and multiwall WS2 nanotubes: Evidence for quantum confinement and strain effect
For nanoparticles with sub-10 nm diameter, the electronic bandgap becomes size dependent due to quantum confinement; this, in turn, affects their electro-optical properties. Thereby, MoS2 and WS2 monolayers acquire luminescent capability, due to the confinement-induced indirect-to-direct bandgap transition. Rolling up of individual layers results in single wall inorganic nanotubes (SWINTs). Up to the present study, their luminescence properties were expected to be auspicious but were limited to theoretical investigations only, due to the scarcity of SWINTs and the difficulties in handling them. By optimizing the conditions in the plasma reactor, relatively high yields of WS2 SWINTs 3–7 nm in diameter were obtained in this work, compared to previous reports. A correlative approach, transmission electron microscopy coupled with a scanning electron microscope, was adapted to overcome handling obstacles and for testing individual nanotubes by low-temperature cathodoluminescence. Clear cathodoluminescence spectra were obtained from WS2-SWINTs and compared with those of WS2 multiwall nanotubes and the corresponding bulk material. Uniquely, the optical properties of INTs acquired from cathodoluminescence were governed by the opposite impact from quantum size effect and strain in the bent triple S-W-S layers. The experimental findings were confirmed by the Density Functional and Time-Dependent Density Functional theoretical modeling of monolayer and bilayer nanotubes of different chiralities and diameters. This study provides experimental evidence of the quantum confinement effect in WS2 SWINTs akin to WS2 monolayer. The ability to tune the electronic structure with morphology or number of layers may be exploited toward photoelectrochemical water splitting with WS2 catalysts, devising field effect transistors, photodetectors, and so on.
- Open Access
Sputtered Platinum Thin-films for Oxygen Reduction in Gas Diffusion Electrodes: A Model System for Studies under Realistic Reaction Conditions
The development of catalysts for the oxygen reduction reaction in low-temperature fuel cells depends on efficient and accurate electrochemical characterization methods. Currently, two primary techniques exist: rotating disk electrode (RDE) measurements in half-cells with liquid electrolyte and single cell tests with membrane electrode assemblies (MEAs). While the RDE technique allows for rapid catalyst benchmarking, it is limited to electrode potentials far from operating fuel cells. On the other hand, MEAs can provide direct performance data at realistic conditions but require specialized equipment and large quantities of catalyst, making them less ideal for early-stage development. Using sputtered platinum thin-film electrodes, we show that gas diffusion electrode (GDE) half-cells can be used as an intermediate platform for rapid benchmarking at fuel-cell relevant current densities (~1 A cm−2). Furthermore, we demonstrate how different parameters (loading, electrolyte concentration, humidification, and Nafion membrane) influence the performance of unsupported platinum catalysts. The specific activity could be measured independent of the applied loading at potentials down to 0.80 VRHE reaching a value of 0.72 mA cm−2 at 0.9 VRHE in the GDE. By comparison with RDE measurements and Pt/C measurements, we establish the importance of catalyst characterization under realistic reaction conditions.
Open AccessSputtered Platinum Thin-films for Oxygen Reduction in Gas Diffusion Electrodes: A Model System for Studies under Realistic Reaction Conditions
The development of catalysts for the oxygen reduction reaction in low-temperature fuel cells depends on efficient and accurate electrochemical characterization methods. Currently, two primary techniques exist: rotating disk electrode (RDE) measurements in half-cells with liquid electrolyte and single cell tests with membrane electrode assemblies (MEAs). While the RDE technique allows for rapid catalyst benchmarking, it is limited to electrode potentials far from operating fuel cells. On the other hand, MEAs can provide direct performance data at realistic conditions but require specialized equipment and large quantities of catalyst, making them less ideal for early-stage development. Using sputtered platinum thin-film electrodes, we show that gas diffusion electrode (GDE) half-cells can be used as an intermediate platform for rapid benchmarking at fuel-cell relevant current densities (~1 A cm−2). Furthermore, we demonstrate how different parameters (loading, electrolyte concentration, humidification, and Nafion membrane) influence the performance of unsupported platinum catalysts. The specific activity could be measured independent of the applied loading at potentials down to 0.80 VRHE reaching a value of 0.72 mA cm−2 at 0.9 VRHE in the GDE. By comparison with RDE measurements and Pt/C measurements, we establish the importance of catalyst characterization under realistic reaction conditions.