AAAbeer Abdellatef

Abeer Abdellatef

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Abeer Abdellatef has a total of 216 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Serum long noncoding RNA human plasmacytoma variant translocation 1 (PVT1) expression levels in Egyptians type 2 diabetic patients and its correlation with severity of diabetic nephropathy

    by Aya Tarabay, Olfat Gamil Shaker, Naglaa M. ElSayed, Dina Allam, Abeer Abdellatef, Mazen Attia

    Continuous rise in the global incidence of type 2 diabetes mellitus (T2DM) has been associated with a marked increase in diabetic kidney disease (DKD). Des

  • Open Access

    Recurrent congenital pancreatic pseudocyst: an exceptionally rare case report

    by Hussein Hassan Okasha, Abeer Abdellatef, Mohamed Nabil Alkady

    Background: Congenital pancreatic pseudocysts are extremely rare in children, with unclear etiologyand limited reported cases. Their diagnosis is challenging, especially in true congenital cases identified before birth. Management varies based on etiology, size, and location, with surgical intervention often required. Case presentation: We present a rare case of a 3-year-old girl with recurrent pancreatic pseudocyst after surgical cystectomy performed when she was8 months old. Contrast-enhanced computed tomography (CT) and endoscopic ultrasound (EUS) confirmed the diagnosis, and cystogastrostomy was performed. Fluid analysis and cytology indicated an inflamed pancreatic pseudocyst without malignancy or bacterial growth. Conclusion: To our knowledge, this is the first documented case of recurrent congenital pancreatic pseudocyst following surgical correction. It highlights the need for long-term follow-up and further research on optimal management strategies for such rare cases.

  • Open Access

    Endoscopic ultrasound-guided biopsy for TB lymphadenopathy: role of PCR and Gene X-pert

    by Hussein Hassan Okasha, Rasha M. M. Ahmed, Abeer Abdellatef, Mona A. Wassef, Hossam El-Din Shaaban, Rasha Matar

    Tuberculous lymphadenopathy presents a challenging diagnostic scenario, particularly in regions with high tuberculosis (TB) prevalence. Abdominal TB accounts for 10% of extrapulmonary TB cases. Diagnosing abdominal TB is difficult due to nonspecific clinical, radiological, and endoscopic findings. Blood and skin tests for TB exhibit variable sensitivities and specificities; therefore, histopathological diagnosis and molecular testing of tissue samples may provide greater accuracy than blood-based tests. Obtaining tissue samples under ultrasonographic or CT guidance can be difficult and risky, especially in intra-abdominal and mediastinal regions. Endoscopic ultrasound (EUS) and EUS-guided fine-needle biopsy (EUS-FNB) offer a safe technique for obtaining tissue samples for the diagnosis of abdominal and mediastinal TB. Comparative analyses of the Gene X-pert MTB/RIF assay and PCR techniques demonstrate nuanced diagnostic capabilities. Gene X-pert enables rapid molecular detection with high specificity for rifampicin resistance, whereas PCR facilitates molecular amplification of bacterial DNA. EUS provides the critical advantage of real-time imaging and precise tissue sampling. Several studies have found that EUS-FNB yields significantly higher diagnostic accuracy in complex TB presentations, with detection rates ranging from 78 to 92% across various anatomical sites. This review explores the diagnostic efficacy of molecular techniques, specifically polymerase chain reaction (PCR) and the Gene X-pert MTB/RIF assay, in detecting Mycobacterium tuberculosis in tissue samples obtained through EUS-FNB. Additionally, we evaluated the sensitivity, specificity, and rapid detection capabilities of these molecular methods compared to traditional diagnostic techniques. We further discussed whether molecular techniques such as PCR and Gene X-pert provide a powerful diagnostic strategy for TB lymphadenopathy in EUS-FNB tissue samples, thereby overcoming the limitations of conventional diagnostic methods.


  • Open Access

    Endoscopic Ultrasound-Guided Fine Needle Biopsy with Stylet and Suction Versus No Stylet No Suction for the Diagnosis of Pancreatic and Non-Pancreatic Lesions

    by Marwa Ahmed, Mohamed Yousri Ahmed, Hossam Eldin Shaaban, Sameh Ea Abou Elenin, Ahmed Ali El-Habashi, Fatima Belabbes, Mohammed Tag-Adeen, Abeer Abdellatef, Hussein Hassan Okasha

    Background: Endoscopic ultrasound (EUS)-guided tissue acquisition is the procedure of choice to obtain samples to diagnose pancreatic and non-pancreatic lesions. Previous randomized trials demonstrated that using stylets during the EUS-fine needle biopsy (FNB) technique does not improve the diagnostic yield. However, little data exists regarding the role of stylet and suction in the core biopsy needle during EUS-guided tissue acquisition. Aim of the Study: This study aims to assess the efficacy and diagnostic yield of samples collected by EUS-FNB with stylet and suction versus no stylet, no suction techniques. Patients and Methods: This prospective study included 167 patients referred to the Gastroenterology Division, Internal Medicine Department, Kasr Al-Aini Hospitals for EUS-guided biopsy from pancreatic or non-pancreatic lesions from May 2021 to January 2024. Each lesion was sampled twice using an EUS-FNB 22-gauge Franseen-tip needle (Acquire; Boston Scientific, USA); one sample was collected with stylet and suction, while the other with no stylet no suction technique. Subsequently, slides were evaluated for cellularity, tissue integrity, degree of blood contamination, and diagnostic ability. Results: A total of 167 patients fulfilled the inclusion criteria, 78 females and 89 males, with a mean age of 61 years. Most lesions were pancreatic (83.2%, n = 139), while the remaining (16.8%, n = 28) were non-pancreatic. No significant differences were observed between stylet and suction versus no stylet, no suction techniques. The diagnostic performance, including sensitivity, specificity, and overall accuracy, was identical (100%) for both methods when evaluating alcohol-fixed smears in conjunction with formalin-preserved tissues collected through FNB. Conclusion: EUS-FNB tissue acquisition with and without stylet and suction provides comparable diagnostic yield and tissue quality for pancreatic and non-pancreatic lesions. The decision to use a stylet and suction should be individualized based on the clinical context and operator experience.

  • Metabolic Dysfunction‐Associated Steatotic Liver Disease in the MENA Region: Setting a Research and Action Priority Agenda

    by Mohamed El‐Kassas, Marcela Villota‐Rivas, Khalid A. Alswat, Khalid M. AlNaamani, Yusuf Yilmaz, Asma Labidi, Faisal M. Sanai, Abeer Awad, Maisam W. I. Akroush, Saleh A. Alqahtani, et al.

    Background & Aims: Metabolic dysfunction‐associated steatotic liver disease (MASLD) is a growing health challenge, particularly in Middle East and North Africa (MENA) countries. This study aimed to establish a consensus‐driven research and action agenda to address MASLD within the MENA region.Methods: Following a global MASLD research and action agenda setting study, over two Delphi rounds (Rs), MENA region experts (R1 n = 112, R2 n = 104) indicated their level of agreement with and provided feedback on MASLD research and action priorities via Qualtrics XM. In R2, panellists also ranked the priorities, which were categorised across six domains: (1) the human and economic burden, (2) defining and implementing care models, (3) disease management, (4) education and awareness, (5) patient and community perspectives, and (6) leadership and policies for the MASLD public health agenda.Results: The consensus‐built MASLD research and action priority agenda for the MENA region comprises 52 priorities. Combined agreement (i.e., ‘agree’ + ‘somewhat agree’) increased from 97.6% and 98.1% in R1 to 98.2% and 98.5% in R2 with the research (n = 30) and action (n = 22) priorities, respectively. The highest ranked research priorities included developing regional MASLD databases and validating non‐invasive diagnostic tools. The highest ranked action priorities included taking steps to enhance the adoption of lifestyle interventions among people living with MASLD and improving disease knowledge among healthcare providers.Conclusions: This region‐specific agenda can help to guide research and optimise clinical practice, thereby improving the understanding, prevention, and management of MASLD, enhancing health outcomes and reducing its burden within the MENA region.


  • Open Access

    The role of endoscopic ultrasound in the diagnosis and characterization of focal liver lesions

    by Ahmed Morad Hashim, Gamal Eldin Mansour Mohamed Gamal, Abeer Abdellatef, Hany Hagag Ahmed

    Background: Incidentally discovered focal liver lesions (FLLs) are a common reason for referral to hepatobiliary services. These lesions are frequently found in patients with colorectal cancer, cirrhosis, or incidentally during evaluations for abdominal pain or shock. Several established diagnostic tools such as magnetic resonance imaging (MRI), transabdominal ultrasound (US), and computed tomography (CT) are well-studied for assessing liver diseases. Endoscopic ultrasound (EUS), traditionally used for evaluating the mediastinum, biliary tract, esophagus, stomach, and pancreas, is increasingly complementing these traditional diagnostic methods in hepatology. The study aimed to delineate the endoscopic ultrasound elastography role in visualization and hepatic focal hepatic tissue differentiation of lesions in comparison to the routine radiological and laboratory methods. Methods: A cross-sectional study was conducted, we enrolled 41 patients with hepatic focal lesions, abdominal ultrasonography, triphasic CT abdomen, and Endosonography examinations were performed on all participants. Results: There was a highly significant difference between the studied groups as regards the Strain Ratio and Echogenicity (P0.01). Conclusion: Ultrasound elastography and strain ratio are promising, non-invasive, nondependent on any contrast material techniques that could significantly enhance routine grey-scale sonographic examinations of the liver by better delineating the characteristics of hepatic focal lesions.


  • Open Access

    The role of endoscopic ultrasound (EUS) in detecting common bile duct (CBD) stones missed post-endoscopic retrograde cholangiopancreatography (ERCP) in patients with calculous obstructive jaundice

    by Mohamed Badr Hassan, Ahmed Morad Hashim, Mahmoud Abd Elnabi Mohamed Darwish, Abeer Abdellatef

    Background: Choledocholithiasis occurs in up to 20% of patients with gallstones. Diagnosing choledocholithiasis can be challenging. Previously, the gold standard for diagnosis was endoscopic retrograde cholangiopancreatography (ERCP). However, small stones often evade detection through ERCP and magnetic resonance cholangiopancreatography (MRCP). Endoscopic ultrasound (EUS) has proven effective in identifying common bile duct (CBD) stones that MRCP and ERCP might miss, particularly small stones or those lodged in the distal CBD or papillary region. The study aimed to evaluate the accuracy of EUS in detecting CBD stones missed by MRCP and ERCP. Methods: A case–control study was conducted; we enrolled 30 patients who were presented with calculous obstructive jaundice and had undergone both ERCP and MRCP. A stent was inserted in these patients. Prior to stent removal, these patients underwent EUS to evaluate its effectiveness in detecting any remaining CBD stones post-ERCP. The sensitivity and specificity of EUS, ERCP, and MRCP were compared based on the presence, size, and number of detected stones. Results: The mean age of involved patients was 50.3 ± 10.2 years. ERCP demonstrated a sensitivity of 44.4%, specificity of 100%, positive predictive value (PPV) of 100%, negative predictive value (NPV) of 16.6%, and an accuracy of 50%. MRCP showed a sensitivity of 81.5%, specificity of 100%, PPV of 100%, NPV of 37.5%, and an accuracy of 83.3% when compared with EUS results. The complication rate for EUS was significantly lower than that for diagnostic ERCP. Additionally, an EUS-based strategy was more cost-effective than diagnostic ERCP for patients with low, moderate, or high risk. Conclusion: Endoscopic ultrasound (EUS) is a promising, non-invasive, non-contrast technique that may serve as a superior diagnostic tool compared with MRCP and ERCP, particularly for detecting small stones or those impacted in the distal CBD or papillary region.


  • Open Access

    Real-life experience of colonic polyps’ detection rate and adenoma detection rate with their characteristics in a cohort of Egyptian patients

    by Abeer Awad Abdellatif, Mohamad Sherif Mogawer, Shaimaa Elkholy, Hany Hagag, Dalia Abdelfatah, Zeinab Abdellatif Mahmoud Soliman, Ahmed Mostafa Mostafa El-Sayed, Alhosaeyn Ibrahim Isa, Omar Mahmoud Ahmed Abou Sebei, Ahmed E. M. Shehata, et al.

    Background: Data on the prevalence of colonic polyps and adenomas in the Egyptian population are scarce. This study aimed to determine the prevalence of colonic polyps among Egyptian patients aged 50 years and older who underwent colonoscopy for a variety of reasons. Patients and methods: This study is a retrospective one that was conducted with the use of an endoscopic reporting database of patients presenting at Cairo University Hospital. The considered variables were age, gender, clinical presentation, polyps’ characteristics, and diagnosis. Polyps were retrieved and sent for histopathological examination. Results: Among 4861 patients whose clinical presentation necessitated colonoscopic examination between 2012 and 2019, 850 consecutive patients aged 50 years and older were enrolled in this study. The median age was 65 ± 9 SD. The male gender was slightly predominant (50.8%). The polyp detection rate was 23.1%, while the adenoma detection rate was 14.7%, and they were mostly encountered on the left side of the colon. By regression analysis, the most important predictors of adenoma were age ≥ 65 years, diabetes, and the presence of a polyp in the right colon. Diabetics and older people (≥ 65 years) had two times increased risk for adenoma, while patients with polyps in the right side of the colon had 30 times increased risk of adenoma. Conclusion: PDR and ADR among the Egyptian population are matched to the target ADR set by the ASGE. We recommend ADR and PDR as key quality indicators of colonoscopy quality.


  • Open Access

    Esophagitis dissecans superficialis: a rare cause of upper GI bleeding

    by Mohamed-Naguib Wifi, Abeer Abdellatef, Dalia Abd El-Kareem, Mohamed Hassan, Amr Maged Lasheen

    Background: Esophagitis dissecans superficialis (EDS) is a rare desquamative esophageal condition with a wide range of presentations, from asymptomatic cases to those with severe, life-threatening symptoms. EDS has a strong association with several conditions, such as autoimmune diseases, smoking, and certain medications, although it can also occur without any apparent cause (idiopathic). Diagnosis involves a comprehensive approach, including clinical assessment (history and examination), endoscopic examination, histopathological analysis, and the exclusion of other potential causes. There is still no established standard treatment for EDS, as many cases resolve spontaneously without long-term complications. Case presentation. We present a case of a 73-year-old female with an episode of upper gastrointestinal bleeding (UGIB) due to Esophagitis dissecans superficialis, which had a favorable outcome after therapy with a proton pump inhibitor (PPI). Conclusion: Although EDS is a rare condition, it should be considered a cause of UGIB in patients with risk factors.


  • Open Access

    Comparative diagnostic performance of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) versus endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) for tissue sampling of solid pancreatic and non-pancreatic lesions without ROSE: a prospective multicenter study

    by Hussein Hassan Okasha, Mohammed Yousri Ahmed, Marwa A. Ahmed, Sameh Abou Elenin, Abeer Abdel-Latif, Mahmoud Farouk, Mahmoud Gamal Ameen, Ahmed Hussein El-Habashi, Mahasen Akram Elshaer, Ahmed Elsayed Alzamzamy

    Background and aims: Endoscopic ultrasound-guided tissue acquisition, including both fine-needle aspiration (EUS-FNA) and fine-needle biopsy (EUS-FNB), has been frequently performed to acquire samples from both pancreatic and non-pancreatic lesions. Still, the impact of the diagnostic yield between FNA and FNB is uncertain. We conducted this study to compare the diagnostic performance and accuracy of the 22-gauge FNA needles with the 22-gauge FNB needles in sampling solid pancreatic and non-pancreatic lesions. Methods: This is a prospective multicenter study conducted on 465 cases presented with solid pancreatic or non-pancreatic lesions. Results: Patients were 275 male and 190 females with a mean age of 59 years. Three-hundred twenty-seven patients had solid pancreatic lesions, while 138 had non-pancreatic lesions; 245 cases underwent EUS-FNA, and the remaining 211 cases underwent EUS-FNB. The presence of intact tissue core and sample adequacy was significantly higher in the FNB cases in solid pancreatic and non-pancreatic lesions. Blood contamination was significantly more in cell blocks and smears of EUS-FNA compared to that of EUS-FNB in solid pancreatic and non-pancreatic lesions. Based on histologic assessment of cell block only, EUS-FNB had more diagnostic accuracy (99%) than FNA (61%) (P-value < 0.005). However, cytological diagnosis by smears only showed no significant difference. The combined cytological and histological evaluation had 100% sensitivity, specificity, and accuracy. Conclusion: EUS-FNA and EUS-FNB have comparable accuracy in diagnosing solid pancreatic and non-pancreatic lesions without ROSE. EUS-FNB is superior to EUS-FNA in acquiring intact tissue core and adequate samples with little blood contamination. Based on histological assessment (cell block/tissue core) only, EUS-FNA has less accuracy than EUS-FNB in diagnosing solid pancreatic lesions.