H. Umesha Shetty
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
H. Umesha Shetty has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Victor W. Pike
Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health (NIMH/NIH), Building 10, Room B3C351, 10 Center Drive, MSC 1003, Bethesda, MD, 20892, USA
4 shared publications- Victor William Pike
Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, MD 20892, USA
4 shared publications Robert B. Innis
Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health (NIMH/NIH), Building 10, Room B3C351, 10 Center Drive, MSC 1003, Bethesda, MD, 20892, USA
3 shared publications- Robert Stewart
Department of Psychological Medicine, Institute of Psychiatry, Psychology & Neuroscience, King’s College London, London, UK
3 shared publications Sami S. Zoghbi
Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health (NIMH/NIH), Building 10, Room B3C351, 10 Center Drive, MSC 1003, Bethesda, MD, 20892, USA
3 shared publicationsAmira K. Brown
2 shared publications
Latest Publications
- Open Access
- 18 January 2026
- Published by Wiley in Chemistry–Methods
- Vol. 6 (1)
Liquid Chromatography‐Tandem Mass Spectrometry Methods for Rapid Measurement of the Molar Activity ( A m ) of Cyclotron‐Produced [ 18 F]Fluoride and Derived Radiotracers
Fluorine‐18 is an attractive positron‐emitter for positron emission tomography (PET) because of its half‐life ( t 1/2 = 109.8 min) and availability as [ 18 F]fluoride ion in high activity from biomedical cyclotrons. For 18 F‐labeled tracers intended to image low‐density protein targets (e.g., receptors, transporters and enzymes), the molar activity ( A m ) must be high (usually > 37 GBq μmol −1 ) to comply with the tracer principle, avoid attenuation of specific signal, and minimize pharmacological effects. Typically, A m is determined by measuring radioactivity with an ionization chamber and total tracer isotopologue mass with high‐performance liquid chromatography with ultraviolet absorbance detection. Molar activities often vary widely across day‐to‐day tracer productions and between PET radiochemistry laboratories. The terminal radiometric methods provide little insight into sources of carrier. Here, we describe accurate and simple nonradiometric methods for measuring A m for [ 18 F]fluoride through highly sensitive liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) on two rapidly derived surrogates, [ 18 F]fallypride and [ 18 F]4‐(pyrrolidine‐1‐carbonyl)benzenesulfonyl fluoride. These methods can serve as forensic tools for investigating the sources of carrier in tracer syntheses and for A m determinations during routine tracer productions. Moreover, the LC‐MS/MS technique can be applied to radiotracers lacking a strong UV chromophore, as with [ 18 F]2‐fluoro‐2‐deoxy‐D‐glucose tetraacetate, an intermediate in the synthesis of the most widely used PET tracer, [ 18 F]2‐fluoro‐2‐deoxy‐D‐glucose.
- 18 January 2026
- Published by Wiley in Chemistry–Methods
- Vol. 6 (1)
Open AccessLiquid Chromatography‐Tandem Mass Spectrometry Methods for Rapid Measurement of the Molar Activity ( A m ) of Cyclotron‐Produced [ 18 F]Fluoride and Derived Radiotracers
Fluorine‐18 is an attractive positron‐emitter for positron emission tomography (PET) because of its half‐life ( t 1/2 = 109.8 min) and availability as [ 18 F]fluoride ion in high activity from biomedical cyclotrons. For 18 F‐labeled tracers intended to image low‐density protein targets (e.g., receptors, transporters and enzymes), the molar activity ( A m ) must be high (usually > 37 GBq μmol −1 ) to comply with the tracer principle, avoid attenuation of specific signal, and minimize pharmacological effects. Typically, A m is determined by measuring radioactivity with an ionization chamber and total tracer isotopologue mass with high‐performance liquid chromatography with ultraviolet absorbance detection. Molar activities often vary widely across day‐to‐day tracer productions and between PET radiochemistry laboratories. The terminal radiometric methods provide little insight into sources of carrier. Here, we describe accurate and simple nonradiometric methods for measuring A m for [ 18 F]fluoride through highly sensitive liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) on two rapidly derived surrogates, [ 18 F]fallypride and [ 18 F]4‐(pyrrolidine‐1‐carbonyl)benzenesulfonyl fluoride. These methods can serve as forensic tools for investigating the sources of carrier in tracer syntheses and for A m determinations during routine tracer productions. Moreover, the LC‐MS/MS technique can be applied to radiotracers lacking a strong UV chromophore, as with [ 18 F]2‐fluoro‐2‐deoxy‐D‐glucose tetraacetate, an intermediate in the synthesis of the most widely used PET tracer, [ 18 F]2‐fluoro‐2‐deoxy‐D‐glucose.
- Open Access
- 23 June 2022
- Published by American Chemical Society (ACS) in ACS Measurement Science Au
- Vol. 2 (4) , 370-376
Tandem Mass Spectrometry as an Independent Method for Corroborating Fluorine-18 Radioactivity Measurements in Positron Emission Tomography
Positron emission tomography (PET) uses many tracers labeled with fluorine-18 (t(1/2) = 109.8 min; beta(+) 97%) for quantitative imaging of biochemical and physiological processes in animal and human subjects. In PET methodology, the radioactivity in a dose of an F-18-labeled tracer to be administered to a living subject is measured with a calibrated ionization chamber. This type of detector measures the radioactivity of a sample relative to those of certified amounts of longer-lived surrogate isotopes that are recommended for detector calibration. No alternative means for corroborating widely varying fluorine-18 radioactivity measurements from calibrated ionization chambers has been available. Here, we describe an independent nonradiometric method for this purpose. In this method, highly sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) is used to quantify the relative masses of the radioactive isotopologue ([F-18]1) and the accompanying nonradioactive counterpart (carrier 1) in an F-18-labeled tracer preparation to give the mole ratio of [F-18]1. High-performance liquid chromatography (HPLC) with a mass-calibrated absorbance detection is used alongside to provide a separate measurement of the aggregate mass of all isotopologues. The radioactivity of the radiotracer is then derived in becquerels (Bq) from these two measurements, plus Avogadro's number and the decay constant of fluorine-18. For the chosen example [F-18]LSN3316612, the radioactivity values determined nonradiometrically and with a selected ionization chamber were in fair agreement. In addition, LC-MS/MS alone was found to provide an accurate measure of the half-life of fluorine-18.
- 23 June 2022
- Published by American Chemical Society (ACS) in ACS Measurement Science Au
- Vol. 2 (4) , 370-376
Open AccessTandem Mass Spectrometry as an Independent Method for Corroborating Fluorine-18 Radioactivity Measurements in Positron Emission Tomography
Positron emission tomography (PET) uses many tracers labeled with fluorine-18 (t(1/2) = 109.8 min; beta(+) 97%) for quantitative imaging of biochemical and physiological processes in animal and human subjects. In PET methodology, the radioactivity in a dose of an F-18-labeled tracer to be administered to a living subject is measured with a calibrated ionization chamber. This type of detector measures the radioactivity of a sample relative to those of certified amounts of longer-lived surrogate isotopes that are recommended for detector calibration. No alternative means for corroborating widely varying fluorine-18 radioactivity measurements from calibrated ionization chambers has been available. Here, we describe an independent nonradiometric method for this purpose. In this method, highly sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) is used to quantify the relative masses of the radioactive isotopologue ([F-18]1) and the accompanying nonradioactive counterpart (carrier 1) in an F-18-labeled tracer preparation to give the mole ratio of [F-18]1. High-performance liquid chromatography (HPLC) with a mass-calibrated absorbance detection is used alongside to provide a separate measurement of the aggregate mass of all isotopologues. The radioactivity of the radiotracer is then derived in becquerels (Bq) from these two measurements, plus Avogadro's number and the decay constant of fluorine-18. For the chosen example [F-18]LSN3316612, the radioactivity values determined nonradiometrically and with a selected ionization chamber were in fair agreement. In addition, LC-MS/MS alone was found to provide an accurate measure of the half-life of fluorine-18.
- Open Access
Mental healthcare utilisation by patients before and after receiving paliperidone palmitate treatment: mirror image analyses
Objectives To compare mental healthcare use and healthcare professional (HCP) contacts for patients before and after initiation of paliperidone palmitate. Setting The South London and Maudsley NHS Foundation Trust (SLAM) Biomedical Research Centre Clinical Record Interactive Search. Participants We identified all adults with a diagnosis of schizophrenia (International Classification of Diseases 10th Revision: F20.x), who had received paliperidone palmitate prescription for at least 365 days and had at least 1 year of recorded treatment from SLAM, prior to the first recorded receipt of paliperidone palmitate. Primary and secondary outcome measures Inpatient and community mental healthcare service use, such as inpatient bed days, number of active days in the service, face-to-face and telephone HCP use in the 12 months before and after paliperidone palmitate initiation. Results We identified 664 patients initiated on paliperidone palmitate. Following initiation, inpatient bed days were lower, although patients remained active on the service case load longer for both mirror approach 1 (mean difference of inpatient bed days −10.48 (95% CI −15.75 to −5.22); days active 40.67 (95% CI 33.39 to 47.95)) and mirror approach 2 (mean difference of inpatient bed days −23.96 (95% CI −30.01 to −17.92); mean difference of days active 40.69 (95% CI 33.39 to 47.94)). The postinitiation period was further characterised by fewer face-to-face and telephone contacts with medical and social work HCPs, and an increased contact with clinical psychologists. Conclusions Our findings indicate a change in the profile of HCP use, consistent with a transition from treatment to possible rehabilitation.
Open AccessMental healthcare utilisation by patients before and after receiving paliperidone palmitate treatment: mirror image analyses
Objectives To compare mental healthcare use and healthcare professional (HCP) contacts for patients before and after initiation of paliperidone palmitate. Setting The South London and Maudsley NHS Foundation Trust (SLAM) Biomedical Research Centre Clinical Record Interactive Search. Participants We identified all adults with a diagnosis of schizophrenia (International Classification of Diseases 10th Revision: F20.x), who had received paliperidone palmitate prescription for at least 365 days and had at least 1 year of recorded treatment from SLAM, prior to the first recorded receipt of paliperidone palmitate. Primary and secondary outcome measures Inpatient and community mental healthcare service use, such as inpatient bed days, number of active days in the service, face-to-face and telephone HCP use in the 12 months before and after paliperidone palmitate initiation. Results We identified 664 patients initiated on paliperidone palmitate. Following initiation, inpatient bed days were lower, although patients remained active on the service case load longer for both mirror approach 1 (mean difference of inpatient bed days −10.48 (95% CI −15.75 to −5.22); days active 40.67 (95% CI 33.39 to 47.95)) and mirror approach 2 (mean difference of inpatient bed days −23.96 (95% CI −30.01 to −17.92); mean difference of days active 40.69 (95% CI 33.39 to 47.94)). The postinitiation period was further characterised by fewer face-to-face and telephone contacts with medical and social work HCPs, and an increased contact with clinical psychologists. Conclusions Our findings indicate a change in the profile of HCP use, consistent with a transition from treatment to possible rehabilitation.
- Open Access
- 15 October 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-11
Development of a non-radiometric method for measuring the arterial input function of a 11C-labeled PET radiotracer
Positron emission tomography (PET) uses radiotracers to quantify important biochemical parameters in human subjects. A radiotracer arterial input function (AIF) is often essential for converting brain PET data into robust output measures. For radiotracers labeled with carbon-11 (t1/2 = 20.4 min), AIF is routinely determined with radio-HPLC of blood sampled frequently during the PET experiment. There has been no alternative to this logistically demanding method, neither for regular use nor validation. A 11C-labeled tracer is always accompanied by a large excess of non-radioactive tracer known as carrier. In principle, AIF might be obtained by measuring the molar activity (Am; ratio of radioactivity to total mass; Bq/mol) of a radiotracer dose and the time-course of carrier concentration in plasma after radiotracer injection. Here, we implement this principle in a new method for determining AIF, as shown by using [11C]PBR28 as a representative tracer. The method uses liquid chromatography-tandem mass spectrometry for measuring radiotracer Am and then the carrier in plasma sampled regularly over the course of a PET experiment. Am and AIF were determined radiometrically for comparison. The new non-radiometric method is not constrained by the short half-life of carbon-11 and is an attractive alternative to conventional AIF measurement.
- 15 October 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-11
Open AccessDevelopment of a non-radiometric method for measuring the arterial input function of a 11C-labeled PET radiotracer
Positron emission tomography (PET) uses radiotracers to quantify important biochemical parameters in human subjects. A radiotracer arterial input function (AIF) is often essential for converting brain PET data into robust output measures. For radiotracers labeled with carbon-11 (t1/2 = 20.4 min), AIF is routinely determined with radio-HPLC of blood sampled frequently during the PET experiment. There has been no alternative to this logistically demanding method, neither for regular use nor validation. A 11C-labeled tracer is always accompanied by a large excess of non-radioactive tracer known as carrier. In principle, AIF might be obtained by measuring the molar activity (Am; ratio of radioactivity to total mass; Bq/mol) of a radiotracer dose and the time-course of carrier concentration in plasma after radiotracer injection. Here, we implement this principle in a new method for determining AIF, as shown by using [11C]PBR28 as a representative tracer. The method uses liquid chromatography-tandem mass spectrometry for measuring radiotracer Am and then the carrier in plasma sampled regularly over the course of a PET experiment. Am and AIF were determined radiometrically for comparison. The new non-radiometric method is not constrained by the short half-life of carbon-11 and is an attractive alternative to conventional AIF measurement.
- Open Access
- 18 February 2019
- Published by Morressier GmbH
15 - PSYCHIATRIC COMORBIDITY AS A RISK FACTOR FOR THE MORTALITY OF PEOPLE WITH BULIMIA NERVOSA
Bulimia nervosa (BN) is associated with increased mortality. Frequent comorbidities of BN include substance use disorders, affective disorders an |
- 18 February 2019
- Published by Morressier GmbH
Open Access15 - PSYCHIATRIC COMORBIDITY AS A RISK FACTOR FOR THE MORTALITY OF PEOPLE WITH BULIMIA NERVOSA
Bulimia nervosa (BN) is associated with increased mortality. Frequent comorbidities of BN include substance use disorders, affective disorders an |
- Open Access
- 1 July 2016
- Published by Elsevier in Schizophrenia Research
- Vol. 174 (1-3) , 106-112
Predictors of long-term (≥ 6 months) antipsychotic polypharmacy prescribing in secondary mental healthcare
- 1 July 2016
- Published by Elsevier in Schizophrenia Research
- Vol. 174 (1-3) , 106-112
Open AccessPredictors of long-term (≥ 6 months) antipsychotic polypharmacy prescribing in secondary mental healthcare
- Open Access
- 1 January 2013
- Published by Springer Nature in EJNMMI Research
- Vol. 3 (1) , 3
Characterization of fast-decaying PET radiotracers solely through LC-MS/MS of constituent radioactive and carrier isotopologues
The characterization of fast-decaying radiotracers that are labeled with carbon-11 (t 1/2 = 20.38 min), including critical measurement of specific radioactivity (activity per mole at a specific time) before release for use in positron-emission tomography (PET), has relied heavily on chromatographic plus radiometric measurements, each of which may be vulnerable to significant errors. Thus, we aimed to develop a mass-specific detection method using sensitive liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) for identifying 11C-labeled tracers and for verifying their specific radioactivities.
- 1 January 2013
- Published by Springer Nature in EJNMMI Research
- Vol. 3 (1) , 3
Open AccessCharacterization of fast-decaying PET radiotracers solely through LC-MS/MS of constituent radioactive and carrier isotopologues
The characterization of fast-decaying radiotracers that are labeled with carbon-11 (t 1/2 = 20.38 min), including critical measurement of specific radioactivity (activity per mole at a specific time) before release for use in positron-emission tomography (PET), has relied heavily on chromatographic plus radiometric measurements, each of which may be vulnerable to significant errors. Thus, we aimed to develop a mass-specific detection method using sensitive liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) for identifying 11C-labeled tracers and for verifying their specific radioactivities.
- 1 December 2008
- Published by Elsevier in The Journal of Pharmacology and Experimental Therapeutics
- Vol. 327 (3) , 727-735
Radiodefluorination of 3-Fluoro-5-(2-(2-[18F](fluoromethyl)-thiazol-4-yl)ethynyl)benzonitrile ([18F]SP203), a Radioligand for Imaging Brain Metabotropic Glutamate Subtype-5 Receptors with Positron Emission Tomography, Occurs by Glutathionylation in Rat Brain
Metabotropic glutamate subtype-5 receptors (mGluR5) are implicated in several neuropsychiatric disorders. Positron emission tomography (PET) with a suitable radioligand may enable monitoring of regional brain mGluR5 density before and during treatments. We have developed a new radioligand, 3-fluoro-5-(2-(2-[18F](fluoromethyl)thiazol-4-yl)ethynyl)benzonitrile ([18F]SP203), for imaging brain mGluR5 in monkey and human. In monkey, radioactivity was observed in bone, showing release of [18F]-fluoride ion from [18F]SP203. This defluorination was not inhibited by disulfiram, a potent inhibitor of CYP2E1. PET confirmed bone uptake of radioactivity and therefore defluorination of [18F]SP203 in rats. To understand the biochemical basis for defluorination, we administered [18F]SP203 plus SP203 in rats for ex vivo analysis of metabolites. Radio-high-performance liquid chromatography detected [18F]fluoride ion as a major radiometabolite in both brain extract and urine. Incubation of [18F]SP203 with brain homogenate also generated this radiometabolite, whereas no metabolism was detected in whole blood in vitro. Liquid chromatography-mass spectrometry analysis of the brain extract detected m/z 548 and 404 ions, assignable to the [M + H]+ of S-glutathione (SP203Glu) and N-acetyl-S-l-cysteine (SP203Nac) conjugates of SP203, respectively. In urine, only the [M + H]+ of SP203Nac was detected. Mass spectrometry/mass spectrometry and multi-stage mass spectrometry analyses of each metabolite yielded product ions consistent with its proposed structure, including the former fluoromethyl group as the site of conjugation. Metabolite structures were confirmed by similar analyses of SP203Glu and SP203Nac, prepared by glutathione S-transferase reaction and chemical synthesis, respectively. Thus, glutathionylation at the 2-fluoromethyl group is responsible for the radiodefluorination of [18F]SP203 in rat. This study provides the first demonstration of glutathione-promoted radiodefluorination of a PET radioligand.
- 1 December 2008
- Published by Elsevier in The Journal of Pharmacology and Experimental Therapeutics
- Vol. 327 (3) , 727-735
Radiodefluorination of 3-Fluoro-5-(2-(2-[18F](fluoromethyl)-thiazol-4-yl)ethynyl)benzonitrile ([18F]SP203), a Radioligand for Imaging Brain Metabotropic Glutamate Subtype-5 Receptors with Positron Emission Tomography, Occurs by Glutathionylation in Rat Brain
Metabotropic glutamate subtype-5 receptors (mGluR5) are implicated in several neuropsychiatric disorders. Positron emission tomography (PET) with a suitable radioligand may enable monitoring of regional brain mGluR5 density before and during treatments. We have developed a new radioligand, 3-fluoro-5-(2-(2-[18F](fluoromethyl)thiazol-4-yl)ethynyl)benzonitrile ([18F]SP203), for imaging brain mGluR5 in monkey and human. In monkey, radioactivity was observed in bone, showing release of [18F]-fluoride ion from [18F]SP203. This defluorination was not inhibited by disulfiram, a potent inhibitor of CYP2E1. PET confirmed bone uptake of radioactivity and therefore defluorination of [18F]SP203 in rats. To understand the biochemical basis for defluorination, we administered [18F]SP203 plus SP203 in rats for ex vivo analysis of metabolites. Radio-high-performance liquid chromatography detected [18F]fluoride ion as a major radiometabolite in both brain extract and urine. Incubation of [18F]SP203 with brain homogenate also generated this radiometabolite, whereas no metabolism was detected in whole blood in vitro. Liquid chromatography-mass spectrometry analysis of the brain extract detected m/z 548 and 404 ions, assignable to the [M + H]+ of S-glutathione (SP203Glu) and N-acetyl-S-l-cysteine (SP203Nac) conjugates of SP203, respectively. In urine, only the [M + H]+ of SP203Nac was detected. Mass spectrometry/mass spectrometry and multi-stage mass spectrometry analyses of each metabolite yielded product ions consistent with its proposed structure, including the former fluoromethyl group as the site of conjugation. Metabolite structures were confirmed by similar analyses of SP203Glu and SP203Nac, prepared by glutathione S-transferase reaction and chemical synthesis, respectively. Thus, glutathionylation at the 2-fluoromethyl group is responsible for the radiodefluorination of [18F]SP203 in rat. This study provides the first demonstration of glutathione-promoted radiodefluorination of a PET radioligand.
- 14 December 2007
- Published by American Chemical Society (ACS) in Journal of Medicinal Chemistry
- Vol. 51 (1) , 148-158
Synthesis and Evaluation of N-Methyl and S-Methyl 11C-Labeled 6-Methylthio-2-(4′-N,N-dimethylamino)phenylimidazo[1,2-a]pyridines as Radioligands for Imaging β-Amyloid Plaques in Alzheimer’s Disease
6-Thiolato-substituted 2-(4′-N,N-dimethylamino)phenylimidazo[1,2-a]pyridines (RS-IMPYs; 1−4) were synthesized as candidates for labeling with carbon-11 (t1/2 = 20.4 min) and imaging of Aβ plaques in living human brain using positron emission tomography (PET). Ki values for binding of these ligands to Alzheimer’s disease brain homogenates were measured in vitro against tritium-labeled 6 (Pittsburgh compound B). MeS-IMPY (3, Ki = 7.93 nM) was labeled with carbon-11 at its S- or N-methyl position to give [11C]7 or [11C]8, respectively. After injection into rats, [11C]7 or [11C]8 gave moderately high brain uptakes of radioactivity followed by rapid washout to low levels. The ratio of radioactivity at maximal uptake to that at 60 min reached 18.7 for [11C]7. [11C]7 behaved similarly in mouse and monkey. [11C]7 also bound selectively to Aβ plaques in post mortem human Alzheimer’s disease brain. Although rapidly metabolized in rat by N-demethylation, [11C]7 was stable in rat brain homogenates. The ex vivo brain radiometabolites observed in rats have a peripheral origin. Overall, [11C]7 merits further evaluation in human subjects.
- 14 December 2007
- Published by American Chemical Society (ACS) in Journal of Medicinal Chemistry
- Vol. 51 (1) , 148-158
Synthesis and Evaluation of N-Methyl and S-Methyl 11C-Labeled 6-Methylthio-2-(4′-N,N-dimethylamino)phenylimidazo[1,2-a]pyridines as Radioligands for Imaging β-Amyloid Plaques in Alzheimer’s Disease
6-Thiolato-substituted 2-(4′-N,N-dimethylamino)phenylimidazo[1,2-a]pyridines (RS-IMPYs; 1−4) were synthesized as candidates for labeling with carbon-11 (t1/2 = 20.4 min) and imaging of Aβ plaques in living human brain using positron emission tomography (PET). Ki values for binding of these ligands to Alzheimer’s disease brain homogenates were measured in vitro against tritium-labeled 6 (Pittsburgh compound B). MeS-IMPY (3, Ki = 7.93 nM) was labeled with carbon-11 at its S- or N-methyl position to give [11C]7 or [11C]8, respectively. After injection into rats, [11C]7 or [11C]8 gave moderately high brain uptakes of radioactivity followed by rapid washout to low levels. The ratio of radioactivity at maximal uptake to that at 60 min reached 18.7 for [11C]7. [11C]7 behaved similarly in mouse and monkey. [11C]7 also bound selectively to Aβ plaques in post mortem human Alzheimer’s disease brain. Although rapidly metabolized in rat by N-demethylation, [11C]7 was stable in rat brain homogenates. The ex vivo brain radiometabolites observed in rats have a peripheral origin. Overall, [11C]7 merits further evaluation in human subjects.
- 10 November 2006
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 34 (5) , 667-678
Identification and regional distribution in rat brain of radiometabolites of the dopamine transporter PET radioligand [11C]PE2I
Purpose We aimed to determine the composition of radioactivity in rat brain after intravenous administration of the dopamine transporter radioligand, [11C]PE2I. Methods PET time-activity curves (TACs) and regional brain distribution ex vivo were measured using no-carrier-added [11C]PE2I. Carrier-added [11C]PE2I was administered to identify metabolites with high-performance liquid radiochromatography (RC) or RC with mass spectrometry (LC-MS and MS-MS). The stability of [11C]PE2I was assessed in rat brain homogenates. Results After peak brain uptake of no-carrier-added [11C]PE2I, there was differential washout rate from striata and cerebellum. Thirty minutes after injection, [11C]PE2I represented 10.9 ± 2.9% of the radioactivity in plasma, 67.1 ± 11.0% in cerebellum, and 92.5 ± 3.2% in striata, and was accompanied by two less lipophilic radiometabolites. [11C]PE2I was stable in rat brain homogenate for at least 1 h at 37°C. LC-MS identified hydroxylated PE2I (1) (m/z 442) and carboxyl-desmethyl-PE2I (2) (m/z 456) in brain. MS-MS of 1 gave an m/z 442→424 transition due to H2O elimination, so verifying the presence of a benzyl alcohol group. Metabolite 2 was the benzoic acid derivative. Ratios of ex vivo measurements of [11C]PE2I, [11C]1, and [11C]2 in striata to their cognates in cerebellum were 6.1 ± 3.4, 3.7 ± 2.2 and 1.33 ± 0.38, respectively, showing binding selectivity of metabolite [11C]1 to striata. Conclusion Radiometabolites [11C]1 and [11C]2 were characterized as the 4-hydroxymethyl and 4-carboxyl analogs of [11C]PE2I, respectively. The presence of the pharmacologically active [11C]1 and the inactive [11C]2 is a serious impediment to successful biomathematical analysis.
- 10 November 2006
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 34 (5) , 667-678
Identification and regional distribution in rat brain of radiometabolites of the dopamine transporter PET radioligand [11C]PE2I
Purpose We aimed to determine the composition of radioactivity in rat brain after intravenous administration of the dopamine transporter radioligand, [11C]PE2I. Methods PET time-activity curves (TACs) and regional brain distribution ex vivo were measured using no-carrier-added [11C]PE2I. Carrier-added [11C]PE2I was administered to identify metabolites with high-performance liquid radiochromatography (RC) or RC with mass spectrometry (LC-MS and MS-MS). The stability of [11C]PE2I was assessed in rat brain homogenates. Results After peak brain uptake of no-carrier-added [11C]PE2I, there was differential washout rate from striata and cerebellum. Thirty minutes after injection, [11C]PE2I represented 10.9 ± 2.9% of the radioactivity in plasma, 67.1 ± 11.0% in cerebellum, and 92.5 ± 3.2% in striata, and was accompanied by two less lipophilic radiometabolites. [11C]PE2I was stable in rat brain homogenate for at least 1 h at 37°C. LC-MS identified hydroxylated PE2I (1) (m/z 442) and carboxyl-desmethyl-PE2I (2) (m/z 456) in brain. MS-MS of 1 gave an m/z 442→424 transition due to H2O elimination, so verifying the presence of a benzyl alcohol group. Metabolite 2 was the benzoic acid derivative. Ratios of ex vivo measurements of [11C]PE2I, [11C]1, and [11C]2 in striata to their cognates in cerebellum were 6.1 ± 3.4, 3.7 ± 2.2 and 1.33 ± 0.38, respectively, showing binding selectivity of metabolite [11C]1 to striata. Conclusion Radiometabolites [11C]1 and [11C]2 were characterized as the 4-hydroxymethyl and 4-carboxyl analogs of [11C]PE2I, respectively. The presence of the pharmacologically active [11C]1 and the inactive [11C]2 is a serious impediment to successful biomathematical analysis.