Dieter Schweizer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dieter Schweizer has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Orcun Goksel
Department of Information Technology, Uppsala University, Uppsala, Sweden
4 shared publications - Richard Rau
ETH Zurich
3 shared publications - Can Deniz Bezek
Department of Information Technology, Uppsala University, Uppsala, Sweden
2 shared publications - Ozan Unal
ETH Zurich
2 shared publications Rahel A. Kubik-Huch
Department of Radiology, Kantonsspital Baden, Baden, Switzerland; Breast Center, Kantonsspital Baden, Baden, Switzerland
2 shared publications- Valery Vishnevskiy
ETH Zurich
2 shared publications
Latest Publications
- Open Access
- 25 July 2025
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 51 (10) , 1831-1839
Pulse-Echo Imaging of Breast Speed of Sound as a Potential Biomarker for Breast Cancer
- 25 July 2025
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 51 (10) , 1831-1839
Open AccessPulse-Echo Imaging of Breast Speed of Sound as a Potential Biomarker for Breast Cancer
- Open Access
- 11 January 2025
- Published by Springer Nature in European Radiology
- Vol. 35 (3) , 1490-1501
Breast density assessment via quantitative sound-speed measurement using conventional ultrasound transducers
Objectives: The aim is to assess the feasibility and accuracy of a novel quantitative ultrasound (US) method based on global speed-of-sound (g-SoS) measurement using conventional US machines, for breast density assessment in comparison to mammographic ACR (m-ACR) categories. Materials and methods: In a prospective study, g-SoS was assessed in the upper-outer breast quadrant of 100 women, with 92 of them also having m-ACR assessed by two radiologists across the entire breast. For g-SoS, ultrasonic waves were transmitted from varying transducer locations and the image misalignments between these were then related analytically to breast SoS. To test reproducibility, two consecutive g-SoS acquisitions each were taken at two similar breast locations by the same operator. Results: Measurements were found highly repeatable, with a mean absolute difference ± standard deviation of 3.16 ± 3.79 m/s. Multiple measurements were combined yielding a single g-SoS estimate per each patient, which strongly correlated to m-ACR categories (Spearman’s = 0.773). The g-SoS values for categories A-D were 1459.6 ± 0.74, 1475.6 ± 15.92, 1515.6 ± 27.10, and 1545.7 ± 20.62, with all groups (except A-B) being significantly different from each other. Dense breasts (m-ACR C&D) were classified with 100% specificity at 78% sensitivity, with an area under the curve (AUC) of 0.931. Extremely dense breasts (m-ACR D) were classified with 100% sensitivity at 77.5% specificity (AUC = 0.906). Conclusion: Quantitative g-SoS measurement of the breast was shown feasible and repeatable using conventional US machines, with values correlating strongly with m-ACR assessments. Key Points: Question Breast density is a strong predictor of risk for breast cancer, which frequently develops in dense tissue regions. Therefore, density assessment calls for refined non-ionizing methods. Findings Quantitative global speed-of-sound (g-SoS) measurement of the breast is shown to be feasible using conventional US machines, repeatable, and able to classify breast density with high accuracy. Clinical relevance Being effective in classifying dense breasts, where mammography has reduced sensitivity, g-SoS can help stratify patients for alternative modalities. Ideal day for mammography or MRI can be determined by monitoring g-SoS. Furthermore, g-SoS can be integrated into personalized risk assessment. Graphical
- 11 January 2025
- Published by Springer Nature in European Radiology
- Vol. 35 (3) , 1490-1501
Open AccessBreast density assessment via quantitative sound-speed measurement using conventional ultrasound transducers
Objectives: The aim is to assess the feasibility and accuracy of a novel quantitative ultrasound (US) method based on global speed-of-sound (g-SoS) measurement using conventional US machines, for breast density assessment in comparison to mammographic ACR (m-ACR) categories. Materials and methods: In a prospective study, g-SoS was assessed in the upper-outer breast quadrant of 100 women, with 92 of them also having m-ACR assessed by two radiologists across the entire breast. For g-SoS, ultrasonic waves were transmitted from varying transducer locations and the image misalignments between these were then related analytically to breast SoS. To test reproducibility, two consecutive g-SoS acquisitions each were taken at two similar breast locations by the same operator. Results: Measurements were found highly repeatable, with a mean absolute difference ± standard deviation of 3.16 ± 3.79 m/s. Multiple measurements were combined yielding a single g-SoS estimate per each patient, which strongly correlated to m-ACR categories (Spearman’s = 0.773). The g-SoS values for categories A-D were 1459.6 ± 0.74, 1475.6 ± 15.92, 1515.6 ± 27.10, and 1545.7 ± 20.62, with all groups (except A-B) being significantly different from each other. Dense breasts (m-ACR C&D) were classified with 100% specificity at 78% sensitivity, with an area under the curve (AUC) of 0.931. Extremely dense breasts (m-ACR D) were classified with 100% sensitivity at 77.5% specificity (AUC = 0.906). Conclusion: Quantitative g-SoS measurement of the breast was shown feasible and repeatable using conventional US machines, with values correlating strongly with m-ACR assessments. Key Points: Question Breast density is a strong predictor of risk for breast cancer, which frequently develops in dense tissue regions. Therefore, density assessment calls for refined non-ionizing methods. Findings Quantitative global speed-of-sound (g-SoS) measurement of the breast is shown to be feasible using conventional US machines, repeatable, and able to classify breast density with high accuracy. Clinical relevance Being effective in classifying dense breasts, where mammography has reduced sensitivity, g-SoS can help stratify patients for alternative modalities. Ideal day for mammography or MRI can be determined by monitoring g-SoS. Furthermore, g-SoS can be integrated into personalized risk assessment. Graphical
- Open Access
- 7 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 70 (10) , 1308-1318
Robust Imaging of Speed of Sound Using Virtual Source Transmission
Speed-of-sound (SoS) is a novel imaging biomarker for assessing biomechanical characteristics of soft tissues. SoS imaging in pulse-echo mode using conventional ultrasound systems with hand-held transducers has the potential to enable new clinical uses. Recent work demonstrated diverging waves from single-element (SE) transmits to outperform plane-wave sequences. However, single-element transmits have severely limited power and hence produce low signal-to-noise ratio (SNR) in echo data. We herein propose Walsh-Hadamard (WH) coded and virtual-source (VS) transmit sequences for improved SNR in SoS imaging. We additionally present an iterative method of estimating beamforming SoS in the medium, which otherwise confound SoS reconstructions due to beamforming inaccuracies in the images used for reconstruction. Through numerical simulations, phantom experiments, and in-vivo imaging data, we show that WH is not robust against motion, which is often unavoidable in clinical imaging scenarios. Our proposed virtual-source sequence is shown to provide the highest SoS reconstruction performance, especially robust to motion-artifacts. In phantom experiments, despite having a comparable SoS root-mean-square-error (RMSE) of 17.5 to 18.0 m/s at rest, with a minor axial probe motion of ≈0.67 mm/s the RMSE for SE, WH, and VS already deteriorate to 20.2, 105.4, 19.0 m/s, respectively; showing that WH produces unacceptable results, not robust to motion. In the clinical data, the high SNR and motion-resilience of VS sequence is seen to yield superior contrast compared to SE and WH sequences.
- 7 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 70 (10) , 1308-1318
Open AccessRobust Imaging of Speed of Sound Using Virtual Source Transmission
Speed-of-sound (SoS) is a novel imaging biomarker for assessing biomechanical characteristics of soft tissues. SoS imaging in pulse-echo mode using conventional ultrasound systems with hand-held transducers has the potential to enable new clinical uses. Recent work demonstrated diverging waves from single-element (SE) transmits to outperform plane-wave sequences. However, single-element transmits have severely limited power and hence produce low signal-to-noise ratio (SNR) in echo data. We herein propose Walsh-Hadamard (WH) coded and virtual-source (VS) transmit sequences for improved SNR in SoS imaging. We additionally present an iterative method of estimating beamforming SoS in the medium, which otherwise confound SoS reconstructions due to beamforming inaccuracies in the images used for reconstruction. Through numerical simulations, phantom experiments, and in-vivo imaging data, we show that WH is not robust against motion, which is often unavoidable in clinical imaging scenarios. Our proposed virtual-source sequence is shown to provide the highest SoS reconstruction performance, especially robust to motion-artifacts. In phantom experiments, despite having a comparable SoS root-mean-square-error (RMSE) of 17.5 to 18.0 m/s at rest, with a minor axial probe motion of ≈0.67 mm/s the RMSE for SE, WH, and VS already deteriorate to 20.2, 105.4, 19.0 m/s, respectively; showing that WH produces unacceptable results, not robust to motion. In the clinical data, the high SNR and motion-resilience of VS sequence is seen to yield superior contrast compared to SE and WH sequences.
- Open Access
- 1 January 2021
- Published by Elsevier in Medical Image Analysis
- Vol. 67, 101875
Frequency-dependent attenuation reconstruction with an acoustic reflector
- 1 January 2021
- Published by Elsevier in Medical Image Analysis
- Vol. 67, 101875
Open AccessFrequency-dependent attenuation reconstruction with an acoustic reflector
- 10 October 2019
- Published by Springer Nature
- p. 601-609
Attenuation Imaging with Pulse-Echo Ultrasound Based on an Acoustic Reflector
- 10 October 2019
- Published by Springer Nature
- p. 601-609
Attenuation Imaging with Pulse-Echo Ultrasound Based on an Acoustic Reflector
- 1 December 2003
- Published by Canadian Science Publishing in Genome
- Vol. 46 (6) , 1070-1076
Karyotype analysis in Hyacinthella dalmatica (Hyacinthaceae) reveals vertebrate-type telomere repeats at the chromosome ends
Chromosome analysis of three different populations of Hyacinthella dalmatica (Lallem.) Trinajstić, an endemic species of the coastal region of southeastern Europe, showed a unique chromosome number, 2n = 2x = 20, and bimodal karyotype with one large and nine smaller pairs of chromosomes. Staining with fluorochromes CMA3 (chromomycin A3) and DAPI (4,6-diamidino-2-phenylindole) revealed heterochromatic regions associated with NORs, centromeres, and several interstitial heterochromatic bands on the longest chromosome pair. Double-target FISH with two ribosomal DNA probes revealed one locus of 5S rRNA genes in the pericentromeric region of chromosome pair 3 and one locus of 18S-5.8S-26S rRNA genes on the short arm of chromosome pair 4 in all plants and populations analyzed. Southern hybridization analysis and FISH experiments demonstrated that the distal ends of H. dalmatica chromosomes contain the vertebrate telomere (5'-TTAGGG-3') repeat type rather than the Arabidopsis (5'-TTTAGGG-3') heptamer, and so suggest that this Asparagales species along with Aloe and Othocallis contains the vertebrate-type telomere repeat.
- 1 December 2003
- Published by Canadian Science Publishing in Genome
- Vol. 46 (6) , 1070-1076
Karyotype analysis in Hyacinthella dalmatica (Hyacinthaceae) reveals vertebrate-type telomere repeats at the chromosome ends
Chromosome analysis of three different populations of Hyacinthella dalmatica (Lallem.) Trinajstić, an endemic species of the coastal region of southeastern Europe, showed a unique chromosome number, 2n = 2x = 20, and bimodal karyotype with one large and nine smaller pairs of chromosomes. Staining with fluorochromes CMA3 (chromomycin A3) and DAPI (4,6-diamidino-2-phenylindole) revealed heterochromatic regions associated with NORs, centromeres, and several interstitial heterochromatic bands on the longest chromosome pair. Double-target FISH with two ribosomal DNA probes revealed one locus of 5S rRNA genes in the pericentromeric region of chromosome pair 3 and one locus of 18S-5.8S-26S rRNA genes on the short arm of chromosome pair 4 in all plants and populations analyzed. Southern hybridization analysis and FISH experiments demonstrated that the distal ends of H. dalmatica chromosomes contain the vertebrate telomere (5'-TTAGGG-3') repeat type rather than the Arabidopsis (5'-TTTAGGG-3') heptamer, and so suggest that this Asparagales species along with Aloe and Othocallis contains the vertebrate-type telomere repeat.