Oliver Pearce
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Oliver Pearce has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
A. Riddick
Department of Trauma & Orthopaedic Surgery, Southmead Hospital, Bristol, UK
2 shared publicationsKhalid Al-Hourani
Edinburgh Orthopaedics, The Royal Infirmary of Edinburgh, Edinburgh, United Kingdom
2 shared publications- Khalid Al-Hourani
Frimley Knee Unit, Frimley Health NHS Foundation Trust, Frimley, UK
2 shared publications Michael Kelly
Department of Orthopaedic Surgery, Southmead Hospital, Bristol, United Kingdom
2 shared publications- Alasdair Bott
Southmead Hospital, Bristol, UK
1 shared publication - Alex Trompeter
St George’s University Hospitals NHS Foundation Trust, London, UK
1 shared publication
Latest Publications
- Open Access
- 4 August 2026
- Published by Wolters Kluwer Health in OTA International
- Vol. 9 (3)
Application of a dynamic wound closure device in orthopaedic trauma patients following fasciotomy: A level-1 trauma center perspective and preliminary case series
The challenge of achieving delayed primary closure of fasciotomy wounds is well known, and multiple techniques of achieving either delayed primary closure or alternative forms of soft-tissue reconstruction have been described in the literature. However, a universally accepted consensus of the optimal management strategy has yet to be established. We describe our experience with a device designed to use the mechanical concept of dermatotraction—a surgical technique that uses the skin's natural elasticity to close wounds. This device (ABRA Surgical, Southmedic, Inc) promotes a delayed primary wound healing environment and facilitates dynamic approximation of wound edges in complex fasciotomy defects. During ward-based dynamic closure fasciotomy defects transition to a state where primary closure is safely achievable. This avoids the need for soft-tissue reconstruction which is associated with variable outcomes and cosmetic acceptance. Here, we present our surgical technique and case series using this dynamic closure device.
- 4 August 2026
- Published by Wolters Kluwer Health in OTA International
- Vol. 9 (3)
Open AccessApplication of a dynamic wound closure device in orthopaedic trauma patients following fasciotomy: A level-1 trauma center perspective and preliminary case series
The challenge of achieving delayed primary closure of fasciotomy wounds is well known, and multiple techniques of achieving either delayed primary closure or alternative forms of soft-tissue reconstruction have been described in the literature. However, a universally accepted consensus of the optimal management strategy has yet to be established. We describe our experience with a device designed to use the mechanical concept of dermatotraction—a surgical technique that uses the skin's natural elasticity to close wounds. This device (ABRA Surgical, Southmedic, Inc) promotes a delayed primary wound healing environment and facilitates dynamic approximation of wound edges in complex fasciotomy defects. During ward-based dynamic closure fasciotomy defects transition to a state where primary closure is safely achievable. This avoids the need for soft-tissue reconstruction which is associated with variable outcomes and cosmetic acceptance. Here, we present our surgical technique and case series using this dynamic closure device.
- 10 September 2021
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 32 (7) , 1435-1441
Three-vessel view debridement of the open tibial fracture: a surgical technique
Adequate debridement of an open fracture is a key component of successful management. Despite having set debridement principles, there is no structured technique available in the literature to guide the surgeon in achieving this. We therefore present a technical note detailing the structured approach to the debridement of any open tibial fracture. Our unit has developed a novel stepwise technique termed locally as the “three-vessel view”. Identifying all three primary vessels of the leg facilitates confirmation of inspection of all lower limb compartments thus minimising the risk of missed devitalised tissue or neglected areas of contamination and the potential for consequent disastrous outcomes as a result of inadequate exposure.
- 10 September 2021
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 32 (7) , 1435-1441
Three-vessel view debridement of the open tibial fracture: a surgical technique
Adequate debridement of an open fracture is a key component of successful management. Despite having set debridement principles, there is no structured technique available in the literature to guide the surgeon in achieving this. We therefore present a technical note detailing the structured approach to the debridement of any open tibial fracture. Our unit has developed a novel stepwise technique termed locally as the “three-vessel view”. Identifying all three primary vessels of the leg facilitates confirmation of inspection of all lower limb compartments thus minimising the risk of missed devitalised tissue or neglected areas of contamination and the potential for consequent disastrous outcomes as a result of inadequate exposure.
- Open Access
- 1 September 2021
- Published by Oxford University Press (OUP) in British Journal of Surgery
- Vol. 108 (Supplement)
578 Insights into Patient Satisfaction with Telephone Fracture Clinic Consultations During COVID-19
Aim: The COVID-19 pandemic led to an unusually fast pace of change in clinical practice in the UK. An early requirement to reduce outpatient attendances to a pminimum meant that this Trust adopted remote consultations for fracture clinics whenever possible. This study aimed to evaluate patient satisfaction with the new system of telephone consultations to assess its acceptability and guide future decisions. Method: 299 patients who received remote telephone consultations for fracture clinic appointments at North Bristol NHS Trust during the COVID-19 pandemic in early 2020 were retrospectively identified and sent a postal survey. Satisfaction levels were assessed through degree of agreement with statements (9 items), yes/no answers (4 questions) and space for comments. Data was analysed with Excel pivot tables and Chi-squared tests. Results: 131 survey responses were included (43.8% response rate). The majority of patients were satisfied overall with the care they received (82%) and preferred a telephone consultation to a face-to-face appointment during the pandemic (78%). However, only 22% maintained this preference in ‘normal’ (pre-COVID-19) times. Conclusions: The positive responses to the survey reassure us that telephone consultations for fracture clinic consultations are acceptable to the majority of patients during a pandemic. The results as well as free text comments will help us ameliorate the fracture clinic service to minimise infection risk without compromising on quality of care.
- 1 September 2021
- Published by Oxford University Press (OUP) in British Journal of Surgery
- Vol. 108 (Supplement)
Open Access578 Insights into Patient Satisfaction with Telephone Fracture Clinic Consultations During COVID-19
Aim: The COVID-19 pandemic led to an unusually fast pace of change in clinical practice in the UK. An early requirement to reduce outpatient attendances to a pminimum meant that this Trust adopted remote consultations for fracture clinics whenever possible. This study aimed to evaluate patient satisfaction with the new system of telephone consultations to assess its acceptability and guide future decisions. Method: 299 patients who received remote telephone consultations for fracture clinic appointments at North Bristol NHS Trust during the COVID-19 pandemic in early 2020 were retrospectively identified and sent a postal survey. Satisfaction levels were assessed through degree of agreement with statements (9 items), yes/no answers (4 questions) and space for comments. Data was analysed with Excel pivot tables and Chi-squared tests. Results: 131 survey responses were included (43.8% response rate). The majority of patients were satisfied overall with the care they received (82%) and preferred a telephone consultation to a face-to-face appointment during the pandemic (78%). However, only 22% maintained this preference in ‘normal’ (pre-COVID-19) times. Conclusions: The positive responses to the survey reassure us that telephone consultations for fracture clinic consultations are acceptable to the majority of patients during a pandemic. The results as well as free text comments will help us ameliorate the fracture clinic service to minimise infection risk without compromising on quality of care.
- 1 April 2021
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 36 (4) , 1380-1387
Predictive Factors for Revision and Survivorship Analysis of a Prevalent 36-mm Metal-on-Metal Total Hip Replacement System: A Large Single-Center Retrospective Cohort Study
- 1 April 2021
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 36 (4) , 1380-1387
Predictive Factors for Revision and Survivorship Analysis of a Prevalent 36-mm Metal-on-Metal Total Hip Replacement System: A Large Single-Center Retrospective Cohort Study
- 15 February 2021
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 31 (5) , 825-840
Evaluation and management of atypical femoral fractures: an update of current knowledge
Atypical femoral fractures are often attributed to the use of anti-resorptive medications such as bisphosphonates (BP). Whilst they have proven effects on fragility fracture prevention, clinical and laboratory evidence is evolving linking BP-related suppression of bone remodelling to the development of atypical stress-related sub-trochanteric fractures (Shane et al. in JBMR 29:1–23, 2014; Odvina et al. in JCEM 90:1294–301, 2005; Durchschlag et al. in JBMR 21(10):1581–1590, 2006; Donnelly et al. in JBMR 27:672–678, 2012; Mashiba et al. in Bone 28(5):524–531, 2001; Dell et al. in JBMR 27(12):2544–2550, 2012; Black et al. in Lancet 348:1535–1541, 1996; Black et al. in NEJM 356:1809–1822, 2007; Black et al. in JAMA 296:2927–2938, 2006; Schwartz et al. in JBMR 25:976–82, 2010). Injuries may present asymptomatically or with prodromal thigh pain and most can be successfully managed with cephalomedullary nailing and discontinuation of BP therapy. Such injuries exhibit a prolonged time to fracture union with high rates of non-union and metal-work failure when compared to typical subtrochanteric osteoporotic femoral fractures. Despite emerging literature on AFFs, their management continues to pose a challenge to the orthopaedic and extended multi-disciplinary team. The purpose of this review includes evaluation of the current evidence supporting the management of AFFs, clinical and radiological features associated with their presentation and a review of reported surgical strategies to treat and prevent these devastating injures.
- 15 February 2021
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 31 (5) , 825-840
Evaluation and management of atypical femoral fractures: an update of current knowledge
Atypical femoral fractures are often attributed to the use of anti-resorptive medications such as bisphosphonates (BP). Whilst they have proven effects on fragility fracture prevention, clinical and laboratory evidence is evolving linking BP-related suppression of bone remodelling to the development of atypical stress-related sub-trochanteric fractures (Shane et al. in JBMR 29:1–23, 2014; Odvina et al. in JCEM 90:1294–301, 2005; Durchschlag et al. in JBMR 21(10):1581–1590, 2006; Donnelly et al. in JBMR 27:672–678, 2012; Mashiba et al. in Bone 28(5):524–531, 2001; Dell et al. in JBMR 27(12):2544–2550, 2012; Black et al. in Lancet 348:1535–1541, 1996; Black et al. in NEJM 356:1809–1822, 2007; Black et al. in JAMA 296:2927–2938, 2006; Schwartz et al. in JBMR 25:976–82, 2010). Injuries may present asymptomatically or with prodromal thigh pain and most can be successfully managed with cephalomedullary nailing and discontinuation of BP therapy. Such injuries exhibit a prolonged time to fracture union with high rates of non-union and metal-work failure when compared to typical subtrochanteric osteoporotic femoral fractures. Despite emerging literature on AFFs, their management continues to pose a challenge to the orthopaedic and extended multi-disciplinary team. The purpose of this review includes evaluation of the current evidence supporting the management of AFFs, clinical and radiological features associated with their presentation and a review of reported surgical strategies to treat and prevent these devastating injures.
- Open Access
- 9 June 2020
- Published by Springer Nature in Cureus
- Vol. 12 (6) , e8520
Proximal Humerus Fractures: Reliability of Neer Versus AO Classification on Plain Radiographs and Computed Tomography
Introduction: Several classifications for proximal humeral fractures exist, with excellent reliability and reproducibility of such classifications being a desirable feature. Despite their widespread use, these systems are variable in both reliability and accuracy. We aimed to, a) assess and compare the reliability of the Neer (complete and abbreviated versions) and Arbeitsgemeinschaft fur Osteosynthesefragenbeing (AO) classifications, and b) identify if computed tomography (CT) made any difference to the reliability of Neer and AO classifications when compared to plain radiographs alone. Materials and methods: This is a single-centre retrospective study identifying all proximal humeral fractures presenting between February 2016 and February 2017 as a result of trauma that subsequently proceeded to CT. Two specialty orthopaedic trainees analysed the plain radiographs as well as CT images over two rounds, spaced two weeks apart. The Neer 16-grade, abbreviated Neer 6-grade and AO classifications were used. Intra- and inter-observer reliability of each classification system was assessed using the Kappa coefficient. Results: Twenty-two patients were included. The mean age was 62 years (SD 14.5). Management changed in 9/22 patients based on CT. Computed tomography changed Neer-16 type in 16% observations, Neer-6 in 10%, and AO in 23%. This was significant when comparing Neer-6 and AO classifications (p = 0.04). Neer-6 had the best inter-observer reliability (0.737) with the management of one patient changing after CT. On X-ray and CT, intra-observer agreement was substantial, >0.7, using Neer-16 and Neer-6 (p0.7 (p<0.005). In comparison, intra- and inter-observer agreements for AO were lower on X-ray and CT, 0.4-0.6, (p<0.005). Conclusion: Our study shows that simplicity is key with a high degree of reliability in the abbreviated Neer classification. Computed tomography allowed greater reliability than radiographs in classifying fractures, affecting management decisions in 41% of patients. The comprehensive Neer classification showed similar intra- and inter-observer reliabilities to AO.
- 9 June 2020
- Published by Springer Nature in Cureus
- Vol. 12 (6) , e8520
Open AccessProximal Humerus Fractures: Reliability of Neer Versus AO Classification on Plain Radiographs and Computed Tomography
Introduction: Several classifications for proximal humeral fractures exist, with excellent reliability and reproducibility of such classifications being a desirable feature. Despite their widespread use, these systems are variable in both reliability and accuracy. We aimed to, a) assess and compare the reliability of the Neer (complete and abbreviated versions) and Arbeitsgemeinschaft fur Osteosynthesefragenbeing (AO) classifications, and b) identify if computed tomography (CT) made any difference to the reliability of Neer and AO classifications when compared to plain radiographs alone. Materials and methods: This is a single-centre retrospective study identifying all proximal humeral fractures presenting between February 2016 and February 2017 as a result of trauma that subsequently proceeded to CT. Two specialty orthopaedic trainees analysed the plain radiographs as well as CT images over two rounds, spaced two weeks apart. The Neer 16-grade, abbreviated Neer 6-grade and AO classifications were used. Intra- and inter-observer reliability of each classification system was assessed using the Kappa coefficient. Results: Twenty-two patients were included. The mean age was 62 years (SD 14.5). Management changed in 9/22 patients based on CT. Computed tomography changed Neer-16 type in 16% observations, Neer-6 in 10%, and AO in 23%. This was significant when comparing Neer-6 and AO classifications (p = 0.04). Neer-6 had the best inter-observer reliability (0.737) with the management of one patient changing after CT. On X-ray and CT, intra-observer agreement was substantial, >0.7, using Neer-16 and Neer-6 (p0.7 (p<0.005). In comparison, intra- and inter-observer agreements for AO were lower on X-ray and CT, 0.4-0.6, (p<0.005). Conclusion: Our study shows that simplicity is key with a high degree of reliability in the abbreviated Neer classification. Computed tomography allowed greater reliability than radiographs in classifying fractures, affecting management decisions in 41% of patients. The comprehensive Neer classification showed similar intra- and inter-observer reliabilities to AO.