JSJames B. Stubbs

James B. Stubbs

*This is an algorithmically generated author record based on publicly available information.

James B. Stubbs has a total of 15 co-authors. Here are the top co-authors by number of shared publications:

  • Ana Grace

    Department of Radiation Oncology, White Memorial Medical Center, 1720 Cesar Chavez Avenue, Los Angeles, California 90033

    1 shared publication
  • Andrew D. Bohner

    Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory, University School of Medicine, Atlanta, GA 30332, USA

    1 shared publication
  • Asher Altman

    School of Chemical & Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA

    1 shared publication
  • Baldassarre Stea

    Department of Radiation Oncology, University of Arizona, Tucson, AZ 85719, USA

    1 shared publication
  • Daniel Silvain

    Radiation Control Office, The University of Arizona, P.O. Box 245101, Tucson, Arizona 85724

    1 shared publication
  • James K. Rains

    Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University School of Medicine, Atlanta, USA

    1 shared publication

Latest Publications

  • Open Access

    Introducing the Stool Stomper: A Device Designed to Enable Accelerated and Standardized Stool Sample Preparation Using the Kato–Katz Technique

    by Asher C. Altman, Andrew D. Bohner, Victoria J. Brown, Lauren Barger, Rudolph L. Gleason, James K. Rains, James B. Stubbs, Kelsey P. Kubelick, Mariana Stephens

    Soil-transmitted helminths (STHs) are parasitic worms that impact over 1.5 billion people globally. The Kato–Katz technique analyzes stool samples for STHs, allowing for individual diagnoses of STH infection and the estimation of community-level prevalence. One challenge that arises with the procedure is that lab technicians often struggle to prepare microscope slides of sufficient quality for analysis after one attempt. As a result, Kato–Katz procedures are repeated, wasting time and resources. To aid technicians during in-field slide preparation, we created the Stool Stomper. The Stool Stomper is a user-friendly, handheld mechanical device that applies constant, uniform pressure to stool samples to ensure standardized sample preparation onto microscope slides to improve egg counts. The Stool Stomper was assessed using artificial eggs during in-country testing in a lab setting in Dodoma, Tanzania, by lab technicians with various experience levels, from beginner to advanced. Compared to the traditional method, we found that the Stool Stomper reduced slide preparation time, reduced artificial egg counting time, and standardized artificial egg counts with more consistent and accurate readings. The current pilot study highlights the potential for future development and integration of the Stool Stomper device into the Kato–Katz technique to improve community-based STH treatment.


  • Open Access

    Capstone During COVID-19: Medical Device Development at Home to Solve Global Health Problems

    by Kelsey P. Kubelick, Rudolph L. Gleason, James K. Rains, James B. Stubbs

  • Feasibility and safety of outpatient brachytherapy in 37 patients with brain tumors using the GliaSite® Radiation Therapy System

    by Kazumi Chino, Daniel Silvain, Ana Grace, James Stubbs, Baldassarre Stea

    Temporary, low dose rate brachytherapy to the margins of resected brain tumors, using a balloon catheter system (GliaSite Radiation Therapy System) and liquid I-125 radiation source (Iotrex), began in 2002 at the University of Arizona Medical Center. Initially, all patients were treated on an inpatient basis. For patient convenience, we converted to outpatient therapy. In this article we review the exposure data and safety history for the 37 patients treated as outpatients. Proper patient selection and instruction is crucial to having a successful outpatient brachytherapy program. A set of evaluation criteria and patient instructions were developed in compliance with the U.S. Nuclear Regulatory Commission's document NUREG-1556 Volume 9 (Appendix U) and Arizona State Nuclear regulatory guidelines, which specify acceptable exposure rates for outpatient release in this setting. Of the 37 patients monitored, 26 patients were treated for recurrent glioblastoma multiforme (GBM), six for primary GBM, and five for metastatic brain tumors. All 37 patients and their primary caregivers gave signed agreement to follow a specific set of instructions and were released for the duration of brachytherapy (3-7 days). The typical prescription dose was 60 Gy delivered at 0.5 cm from the balloon surface. Afterloaded activities in these patients ranged from 90.9 to 750.0 mCi and measured exposure rates at 1 m from the head were less than 14 mR/h. The mean exposure to the caretaker measured by personal radiation Landauer Luxel + whole body dosimeters for 25 caretakers was found to be 9.6 mR, which was significantly less than the mean calculated exposure of 136.8 mR. For properly selected patients, outpatient brachytherapy is simple and can be performed within established regulatory guidelines.