Ravikumar Bhimasingu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ravikumar Bhimasingu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Yellapragada Venkata Pavan Kumar
School of Electronics Engineering, VIT-AP University, Amaravati 522241, Andhra Pradesh, India
20 shared publications - Pinjala Mohana Kishore
Department of Electrical Engineering, Indian Institute of Technology Hyderabad, India
9 shared publications Bogala Ramakrishna
EEE Department, University College of Engineering, JNTUK, India
2 shared publicationsKiran Kumar Munji
Crompton Greaves Ltd., Global R&D Centre, Mumbai, INDIA
2 shared publicationsPurushotham Reddy Chegireddy
Department of Electrical Engineering, Indian Institute of Technology Hyderabad, Hyderabad, India
2 shared publicationsAbhinay Chennamadhavuni
Department of Electrical Engg., National Institute of Technology, Warangal, INDIA
1 shared publication
Latest Publications
- 31 July 2025
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (11) , 14703-14718
Simplified two-vector predictive control for a VSI with LC filter for grid-forming applications
- 31 July 2025
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (11) , 14703-14718
Simplified two-vector predictive control for a VSI with LC filter for grid-forming applications
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (1) , 155-167
Multi-Terminal Fault Locator for Homogeneous Transmission Lines Using Extended Proportions
This paper proposes a fault location estimation algorithm for multi-terminal homogeneous transmission lines using synchronized voltage and current measurements. The algorithm can estimate the fault location using a Polynomial Equation Solution (PES) method, where the fault location is estimated with the help of sequence components of voltage and current data using extended proportions. Further, the proposed method is improved (IPES) by adopting distributed long line model equations and Taylor series to estimate the actual line parameters before estimating the modified fault location. In both the methods, fault location has been estimated without the use of line parameter data. The fault location estimation results have been provided for four terminal and five terminal networks whose mean percentage errors with IPES method are found to be 0.10% and 0.05%, which shows the preciseness of the proposed algorithm. For the considered four terminal network, analysis have been done with unsynchronized data and fault inception angle. From the analysis, it has been observed that the % error is reduced for higher synchronization errors with the inclusion of correction factors. It is also observed that the % error hasn't effected much even with higher fault inception angles.
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (1) , 155-167
Multi-Terminal Fault Locator for Homogeneous Transmission Lines Using Extended Proportions
This paper proposes a fault location estimation algorithm for multi-terminal homogeneous transmission lines using synchronized voltage and current measurements. The algorithm can estimate the fault location using a Polynomial Equation Solution (PES) method, where the fault location is estimated with the help of sequence components of voltage and current data using extended proportions. Further, the proposed method is improved (IPES) by adopting distributed long line model equations and Taylor series to estimate the actual line parameters before estimating the modified fault location. In both the methods, fault location has been estimated without the use of line parameter data. The fault location estimation results have been provided for four terminal and five terminal networks whose mean percentage errors with IPES method are found to be 0.10% and 0.05%, which shows the preciseness of the proposed algorithm. For the considered four terminal network, analysis have been done with unsynchronized data and fault inception angle. From the analysis, it has been observed that the % error is reduced for higher synchronization errors with the inclusion of correction factors. It is also observed that the % error hasn't effected much even with higher fault inception angles.
- 1 August 2023
- Published by Springer Nature in Electrical Engineering
- Vol. 105 (6) , 4271-4287
An interpretative fault location and section identification algorithm for a three-terminal non-homogeneous transmission network
- 1 August 2023
- Published by Springer Nature in Electrical Engineering
- Vol. 105 (6) , 4271-4287
An interpretative fault location and section identification algorithm for a three-terminal non-homogeneous transmission network
- 24 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (5) , 5833-5843
Optimal Sector-Based Sequential Model Predictive Control for Current Source Rectifier
Conventional Model Predictive Control (MPC) methods for Current Source Rectifier (CSR) use either a PI controller or weight factor based methods which require time-consuming tuning methods to develop an efficient controller. Moreover, the limitations on the bandwidth requirements of the LC filter cause resonances and grid current distortions if a Variable Switching Frequency based predictive control is used. So, a new fixed switching frequency based MPC algorithm has been developed to control the load and source current simultaneously thereby facilitating the weight factor less operation and applying a predefined space vector sequence. Unlike the conventional single cost function methods applied to CSR, the proposed method uses separate cost function for each control variable. Simultaneously to provide fixed frequency operation, duty ratio based modulation of grid current control has been applied. A virtual impedance based active damping has been embedded into the supply current control to suppress the oscillations caused by the LC filter and grid current harmonics. Simulation and experimental results have been supported to validate the improvements in terms of supply current THD, steady state, and transient switching performance.
- 24 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (5) , 5833-5843
Optimal Sector-Based Sequential Model Predictive Control for Current Source Rectifier
Conventional Model Predictive Control (MPC) methods for Current Source Rectifier (CSR) use either a PI controller or weight factor based methods which require time-consuming tuning methods to develop an efficient controller. Moreover, the limitations on the bandwidth requirements of the LC filter cause resonances and grid current distortions if a Variable Switching Frequency based predictive control is used. So, a new fixed switching frequency based MPC algorithm has been developed to control the load and source current simultaneously thereby facilitating the weight factor less operation and applying a predefined space vector sequence. Unlike the conventional single cost function methods applied to CSR, the proposed method uses separate cost function for each control variable. Simultaneously to provide fixed frequency operation, duty ratio based modulation of grid current control has been applied. A virtual impedance based active damping has been embedded into the supply current control to suppress the oscillations caused by the LC filter and grid current harmonics. Simulation and experimental results have been supported to validate the improvements in terms of supply current THD, steady state, and transient switching performance.
- Open Access
- 9 October 2021
- Published by Springer Nature in SN Applied Sciences
- Vol. 3 (11) , 1-17
Design of voltage and current controller parameters using small signal model-based pole-zero cancellation method for improved transient response in microgrids
Microgrids are supposed to provide stable power for seamless utility-grid interaction under all conditions as stated by IEEE-1547 standard. But, the use of power electronic inverter makes the microgrid sensitive to transients than synchronous generator-based plants. This degrades the voltage/frequency responses during transients, which can lead to transient stability problem if not controlled properly. Hence, the design of effective closed-loop voltage and current (V/I) controllers is highly desired to control the inverter output against the disturbances. The V/I controllers are based on PI (proportional-cum-integral) formulas. Thus, the effectiveness of V/I controllers relies on how accurate that their gain parameters are tuned. Many PI-tuning methods have been developed in the literature, but, it is yet difficult to identify a suitable method for an application. Also, only a few researchers have focused on the microgrids due to the complexity involved in its controller design by the presence of V/I cascaded dual-loop. Hence, to address this problem, this paper proposes a novel way of designing V/I controller parameters by using pole-zero cancellation method. This method is implemented by deriving the microgrid’s small-signal model. This improves the transient response through reduced system order and/or alleviated sluggish/marginal-stable/unstable poles by adding zeros at same places where those poles are laid, to in effect cancel them. The efficacy of the proposed method over existing methods is assessed by plotting frequency and voltage responses under different test conditions. From the simulation results, it is witnessed that the proposed method relatively improved the transient characteristics of microgrids. Article Highlights: Analyzes the applicability of conventional PI tuning methods for microgrid controllers’ design. Proposes a novel small signal model based pole-zero cancellation method for the design of microgrid controllers. Enhances the gain margin, which improves the stabilization capacity of the system when subjected to disturbances. Improves the transient behavior of frequency and voltage responses, which ensure the safety of sensitive loads.
- 9 October 2021
- Published by Springer Nature in SN Applied Sciences
- Vol. 3 (11) , 1-17
Open AccessDesign of voltage and current controller parameters using small signal model-based pole-zero cancellation method for improved transient response in microgrids
Microgrids are supposed to provide stable power for seamless utility-grid interaction under all conditions as stated by IEEE-1547 standard. But, the use of power electronic inverter makes the microgrid sensitive to transients than synchronous generator-based plants. This degrades the voltage/frequency responses during transients, which can lead to transient stability problem if not controlled properly. Hence, the design of effective closed-loop voltage and current (V/I) controllers is highly desired to control the inverter output against the disturbances. The V/I controllers are based on PI (proportional-cum-integral) formulas. Thus, the effectiveness of V/I controllers relies on how accurate that their gain parameters are tuned. Many PI-tuning methods have been developed in the literature, but, it is yet difficult to identify a suitable method for an application. Also, only a few researchers have focused on the microgrids due to the complexity involved in its controller design by the presence of V/I cascaded dual-loop. Hence, to address this problem, this paper proposes a novel way of designing V/I controller parameters by using pole-zero cancellation method. This method is implemented by deriving the microgrid’s small-signal model. This improves the transient response through reduced system order and/or alleviated sluggish/marginal-stable/unstable poles by adding zeros at same places where those poles are laid, to in effect cancel them. The efficacy of the proposed method over existing methods is assessed by plotting frequency and voltage responses under different test conditions. From the simulation results, it is witnessed that the proposed method relatively improved the transient characteristics of microgrids. Article Highlights: Analyzes the applicability of conventional PI tuning methods for microgrid controllers’ design. Proposes a novel small signal model based pole-zero cancellation method for the design of microgrid controllers. Enhances the gain margin, which improves the stabilization capacity of the system when subjected to disturbances. Improves the transient behavior of frequency and voltage responses, which ensure the safety of sensitive loads.
- 25 August 2021
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 31 (11) , e13068
Sequential model predictive control of quasiZ‐sourceinverter with fixed frequency operation
- 25 August 2021
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 31 (11) , e13068
Sequential model predictive control of quasiZ‐sourceinverter with fixed frequency operation
- 1 February 2021
- Published by Elsevier in Electric Power Systems Research
- Vol. 191
Synchrophasor based fault location algorithm for three terminal homogeneous transmission lines
- 1 February 2021
- Published by Elsevier in Electric Power Systems Research
- Vol. 191
Synchrophasor based fault location algorithm for three terminal homogeneous transmission lines
- 20 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 6 (3) , 1177-1187
Improving the DC-Link Utilization of Nine-Switch Boost Inverter Suitable for Six-Phase Induction Motor
Nowadays multi-phase induction drives are used in electric vehicle applications to improve reliability and efficiency. These induction motors are controlled by using a multi-phase voltage source inverter (VSI). As the number of phases increases, the number of switching devices used in multi-phase VSI also increases, which results in a reduction of the system efficiency and increase in the cost. Among these multi-phase drives, the six-phase drive is used more frequently in electric vehicular industries. For a conventional six-phase VSI requires twelve switches to drive the six-phase machine. Also, conventional six-phase, VSI requires more dc-link voltage than the boost six-phase VSI to drive the six-phase machine. In order to overcome the problems associated with the conventional six-phase VSI controlled six-phase induction drives, this paper proposes a nine-switch boost inverter (NSBI) for six-phase induction drive applications. The proposed NSBI has a single input dc voltage source and it provides six-phase ac output voltages. These six-phase output voltages are regulated by using modified non-sinusoidal pulse width modulation (MNSPWM) technique. The proposed NSBI with a six-phase induction motor is simulated using a MATLAB/Simulink ® and validated using FPGA controlled hardware prototype. The verification of the proposed system during load torque variations, winding failure conditions are carried out.
- 20 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 6 (3) , 1177-1187
Improving the DC-Link Utilization of Nine-Switch Boost Inverter Suitable for Six-Phase Induction Motor
Nowadays multi-phase induction drives are used in electric vehicle applications to improve reliability and efficiency. These induction motors are controlled by using a multi-phase voltage source inverter (VSI). As the number of phases increases, the number of switching devices used in multi-phase VSI also increases, which results in a reduction of the system efficiency and increase in the cost. Among these multi-phase drives, the six-phase drive is used more frequently in electric vehicular industries. For a conventional six-phase VSI requires twelve switches to drive the six-phase machine. Also, conventional six-phase, VSI requires more dc-link voltage than the boost six-phase VSI to drive the six-phase machine. In order to overcome the problems associated with the conventional six-phase VSI controlled six-phase induction drives, this paper proposes a nine-switch boost inverter (NSBI) for six-phase induction drive applications. The proposed NSBI has a single input dc voltage source and it provides six-phase ac output voltages. These six-phase output voltages are regulated by using modified non-sinusoidal pulse width modulation (MNSPWM) technique. The proposed NSBI with a six-phase induction motor is simulated using a MATLAB/Simulink ® and validated using FPGA controlled hardware prototype. The verification of the proposed system during load torque variations, winding failure conditions are carried out.
- Open Access
- 1 March 2020
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 13 (4) , 808-820
Dual‐input and triple‐output boost hybrid converter suitable for grid‐connected renewable energy sources
In grid‐connected distributed energy system, power converters are used to integrate different renewable sources and loads. If the number of sources/loads increases, the number of converters/conversions are required. Because of more conversions and operations, the conversion efficiency decreases, and it is difficult to control load/source parameters independently. In order to overcome the problems associated with the integration of multiple sources and loads, this study proposes a dual‐input and triple‐output boost hybrid converter (DTBHC) with independent control. The dual input ports of the proposed converter can be used to connect two different dc voltage sources. Triple output ports of the proposed converter can be used to connect ac grid, ac local loads, and dc local loads. These load voltages are regulated by using carrier‐based modified sinusoidal pulse‐width modulation (CBMSPWM) technique in order to control the dc and the ac loads independently with respect to sources. The DTBHC with CBMSPWM control is simulated using a MATLAB/Simulink validated using FPGA controlled laboratory prototype. The validation of the proposed converter is carried out with variation of load current, different input voltages to generate stable ac output voltages (same as well as different frequencies).
- 1 March 2020
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 13 (4) , 808-820
Open AccessDual‐input and triple‐output boost hybrid converter suitable for grid‐connected renewable energy sources
In grid‐connected distributed energy system, power converters are used to integrate different renewable sources and loads. If the number of sources/loads increases, the number of converters/conversions are required. Because of more conversions and operations, the conversion efficiency decreases, and it is difficult to control load/source parameters independently. In order to overcome the problems associated with the integration of multiple sources and loads, this study proposes a dual‐input and triple‐output boost hybrid converter (DTBHC) with independent control. The dual input ports of the proposed converter can be used to connect two different dc voltage sources. Triple output ports of the proposed converter can be used to connect ac grid, ac local loads, and dc local loads. These load voltages are regulated by using carrier‐based modified sinusoidal pulse‐width modulation (CBMSPWM) technique in order to control the dc and the ac loads independently with respect to sources. The DTBHC with CBMSPWM control is simulated using a MATLAB/Simulink validated using FPGA controlled laboratory prototype. The validation of the proposed converter is carried out with variation of load current, different input voltages to generate stable ac output voltages (same as well as different frequencies).
- 25 January 2020
- Published by Springer Nature
- p. 111-148
Modern Control Methods for Adaptive Droop Coefficients’ Design
- 25 January 2020
- Published by Springer Nature
- p. 111-148
Modern Control Methods for Adaptive Droop Coefficients’ Design