LCLuis Arturo Aleman Castaneda

Luis Arturo Aleman Castaneda

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Luis Arturo Aleman Castaneda has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Structured light, polarization and birefringence

    by Luis Arturo Aleman Castaneda

    Lumière structurée, polarisation et biréfringence: Le concept de lumière structurée est devenu de plus en plus populaire au sein de la communauté des chercheurs en optique. Ce concept fait référence à l'étude, la génération et les applications de champs optiques dont l'intensité, la phase et/ou la polarisation présentent des variations spatiales qui confèrent à la lumière des propriétés intéressantes ou utiles. Ces degrés de liberté peuvent également porter des informations sur les milieux dans lesquels la lumière s'est propagée et avec lesquels elle a interagi. Il est donc important de savoir comment les manipuler, afin de caractériser les milieux / systèmes optiques. Ces informations peuvent également permettre de corriger ou d'éliminer les biais dans de techniques optiques de mesure. Cette thèse rend compte de quatre projets dans lesquels la lumière structurée, la polarisation et/ou la biréfringence jouent un rôle essentiel et s'entremêlent : 1. Etude de réflecteurs pour l'illumination structurée via des transformations conformes. 2. Interférométrie par cisaillement de polarisation via la phase géométrique. 3. Microscopie polarisée à super-résolution avec l’estimation simultanée de la localisation 3D, de l'orientation 3D et de l'oscillation pour les émetteurs uniques. 4. Elastographie par cisaillement réverbéré pour les matériaux anisotropes

  • Open Access

    4polar3D single molecule imaging of 3D orientation in dense actin networks using ratiometric polarization splitting

    by Charitra S. Senthil Kumar, Cesar A. Valades Cruz, Miguel Sison, Arturo G. Vesga, Javier Rey-Barroso, Valentina Curcio, Luis A. Alemán-Castañeda, Miguel A. Alonso, Renaud Poincloux, Manos Mavrakis, et al.

    Single Molecule Orientation and Localization Microscopy (SMOLM) aims at simultaneously measuring the position and orientation of single molecules, generating orientation-encoded super-resolved images by estimating both their 3D mean orientation and the extent of their angular fluctuations (wobble). Most existing SMOLM approaches rely on the engineering of single molecules’ point spread functions, which requires complex optical setups and long computational times that can be an obstacle in dense cellular environments with high detection density and challenging imaging conditions. In this work, we propose a simpler and effective method named 4polar3D, based on the estimation of single molecule intensities projected onto four polarized channels with controlled numerical apertures. This strategy enables 3D orientation measurements of single molecules within a 0-180° azimuthal range in addition to their angular range of fluctuations and their 2D localization, using a setup requiring minimal alignment complexity. It is moreover based on pure intensity-estimation, making data processing considerably faster than complex PSF shape analysis and relatively insensitive to geometrical aberrations. We demonstrate that 4polar3D can resolve nanoscale molecular organization in whole cells’ crowded structures, uncovering 3D-oriented actin filament networks in densely packed lamellipodia and podosomes.


  • Open Access

    SMOLM-LFM: ratiometric single molecule orientation without polarizers

    by Arturo G. Vesga, Luis Aleman-Castaneda, Hannah S. Heil, Sam Daly, Ezra Bruggeman, Steven F. Lee, Sophie Brasselet, Ricardo Henriques

    Single-molecule orientation and localization microscopy (SMOLM) enables the determination of molecular orientation, wobbling, and position. However, most SMOLM implementations rely on complex point spread function (PSF) fitting, which limits analysis throughput and introduces high computational cost. A way to overcome these limitations is to simplify the analysis using a ratiometric intensity estimation, often relying on polarization projections. While effective in 2D, extending these methods to 3D remains challenging. Here, we introduce a new ratiometric strategy for SMOLM in 3D. Building on the principles of Single Molecule Light Field Microscopy, which captures the 3D position information from a single snapshot by segmenting the back focal plane, we extend this strategy to orientation retrieval. Our approach uses the generalized 3D Stokes formalism to linearly decompose the intensity measurements across the light-field channels, allowing computationally-efficient estimations, while avoiding both complex PSF fitting and polarization projections. This framework, called SMOLM-LFM, enables 6D estimation of single molecules (3D position + 3D orientation) with a simplified optical setup and a large depth-of-field. We present the theoretical foundations, experimental implementation, and validation through measurements on calibration beads, single fluorophores, and cells, thereby demonstrating the method’s potential and practical limitations.

  • Stokes-based analysis for the estimation of 3D dipolar emission

    by Isael Herrera, Luis A. Alemán-Castañeda, Sophie Brasselet, Miguel A. Alonso

    We provide a general description of the measurement capabilities of systems that probe the 3D state of polarization of light emitted by a dipole or a collection of dipoles. This analysis is based on a generalization of the Stokes parameters for 3D polarization, and its goal is to provide insight into what constitutes a good measurement system under specific circumstances, through the definition of appropriate merit functions. Three cases are considered: the general case of arbitrary states of 3D polarization, the special case of 3D linear full or partial polarization states, and the even more specific case of linear dipoles that wobble with rotational symmetry around a central direction. Note that the latter two cases are of interest in fluorescence microscopy. The analysis presented here is illustrated by applying it to two different approaches used commonly in orientation microscopy: PSF engineering and ratiometric measurements.


  • Open Access

    Vectorial phase retrieval in super-resolution polarization microscopy

    by R. Gutiérrez-Cuevas, L. A. Alemán-Castañeda, I. Herrera, S. Brasselet, M. A. Alonso

    In single-molecule orientation localization microscopy, valuable information about the orientation and longitudinal position of each molecule is often encoded in the shape of the point spread function (PSF). Yet, this shape can be significantly affected by aberrations and other imperfections in the imaging system, leading to an erroneous estimation of the measured parameters. A basic solution is to model the aberrations as a scalar mask in the pupil plane that is characterized through phase retrieval algorithms. However, this approach is not suitable for cases involving polarization-dependent aberrations, introduced either through unintentional anisotropy in the elements or by using birefringent masks for PSF shaping. Here, this problem is addressed by introducing a fully vectorial model in which the polarization aberrations are represented via a spatially dependent Jones matrix, commonly used to describe polarization-dependent elements. It is then shown that these aberrations can be characterized by a set of PSF measurements at varying focal planes and for various polarization projections. This PZ-stack of PSFs, which contains diversity in both phase and polarization projection, is used in a phase retrieval algorithm based on nonlinear optimization to determine the aberrations. This methodology is demonstrated with numerical simulations and experimental measurements. The pyPSFstack software developed for modeling and characterization is made freely available.


  • Open Access

    Using fluorescent beads to emulate single flurophores

    by Luis A. Aleman-Castaneda, Sherry Yi-Ting Feng, Rodrigo Gutierrez-Cuevas, Isael Herrera, Thomas G. Brown, Sophie Brasselet, Miguel A. Alonso

    In this work, we study the conditions under which fluorescent beads can be used to emulate single fluorescent molecules in the calibration of optical microscopes. Although beads are widely used due to their brightness and easy manipulation, there can be notable differences between the point spread functions (PSFs) they produce and those for single-molecule fluorophores, caused by their different emission pattern and their size. We study theoretically these differences for various scenarios, e.g. with or without polarization channel splitting, to determine the conditions under which the use of beads as a model for single molecules is valid. We also propose methods to model the blurring due to the size difference and compensate for it to produce PSFs that are more similar to those for single molecules.

  • Using fluorescent beads to emulate single fluorophores

    by Luis A. Alemán-Castañeda, Sherry Yi-Ting Feng, Rodrigo Gutiérrez-Cuevas, Isael Herrera, Thomas G. Brown, Sophie Brasselet, Miguel A. Alonso

    We study the conditions under which fluorescent beads can be used to emulate single fluorescent molecules in the calibration of optical microscopes. Although beads are widely used due to their brightness and easy manipulation, there can be notable differences between the point spread functions (PSFs) they produce and those for single-molecule fluorophores, caused by their different emission patterns and sizes. We study theoretically these differences for various scenarios, e.g., with or without polarization channel splitting, to determine the conditions under which the use of beads as a model for single molecules is valid. We also propose methods to model the blurring due to the size difference and compensate for it to produce PSFs that are more similar to those for single molecules.


  • Reverberant Elastography for the Elastic Characterization of Anisotropic Tissues

    by Luis A. Aleman-Castaneda, Fernando Zvietcovich, Kevin J. Parker

    We derive closed-form solutions for reverberant elastography in anisotropic elastic media by adapting the framework used in electromagnetic theory to treat transverse isotropic materials. Different sample-setup geometries are analyzed, highlighting their relevance for both optical coherence elastography (OCE) and ultrasound elastography (USE). Numerical simulations using finite elements are used to validate the proposed solutions in practical cases. OCE experiments are conducted in ex vivo chicken muscle samples for the characterization of in-plane and out-of-plane shear modulus assuming a transverse isotropic elastic model. Additionally, we obtained a generalized geometry-independent solution for the isotropic media case, thus unifying previous results for reverberant elastography.


  • Open Access

    Reverberant Elastography for the Elastic Characterization of Anisotropic Tissues

    by Luis A. Aleman-Castaneda, Fernando Zvietcovich, Kevin J. Parker

    We derive closed-form solutions for reverberant elastography in anisotropic elastic media by adapting the framework used in electromagnetic theory to treat transverse isotropic materials. Different sample-setup geometries are analyzed, highlighting their relevance for both optical coherence elastography (OCE) and ultrasound elastography (USE). Numerical simulations using finite elements are used to validate the proposed solutions in practical cases. OCE experiments are conducted in ex vivo chicken muscle samples for the characterization of in-plane and out-of-plane shear modulus assuming a transverse isotropic elastic model. Additionally, we obtained a generalized geometry-independent solution for the isotropic media case, thus unifying previous results for reverberant elastography.

  • Open Access

    Birefringent Fourier filtering for single molecule coordinate and height super-resolution imaging with dithering and orientation

    by Valentina Curcio, Luis A. Alemán-Castañeda, Thomas G. Brown, Sophie Brasselet, Miguel A. Alonso

    Super-resolution imaging based on single molecule localization allows accessing nanometric-scale information in biological samples with high precision. However, complete measurements including molecule orientation are still challenging. Orientation is intrinsically coupled to position in microscopy imaging, and molecular wobbling during the image integration time can bias orientation measurements. Providing 3D molecular orientation and orientational fluctuations would offer new ways to assess the degree of alignment of protein structures, which cannot be monitored by pure localization. Here we demonstrate that by adding polarization control to phase control in the Fourier plane of the imaging path, all parameters can be determined unambiguously from single molecules: 3D spatial position, 3D orientation and wobbling or dithering angle. The method, applied to fluorescent labels attached to single actin filaments, provides precisions within tens of nanometers in position and few degrees in orientation.