Songhang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Songhang Li has a total of 100 co-authors. Here are the top co-authors by number of shared publications:
- Yunfeng Lin
State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology Sichuan University Chengdu Sichuan China
15 shared publications - Xiaoxiao Cai
Sichuan University
14 shared publications - Taoran Tian
State Key Laboratory of Oral Diseases, National Center for Stomatology, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China
8 shared publications Tianxu Zhang
State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, P. R. China
7 shared publications- Xueyuan Li
Department of ophthalmology, The General Hospital of Western Theater Command, Chengdu, China
6 shared publications Zhiqiang Liu
5 shared publications
Latest Publications
- Open Access
- 1 December 2026
- Published by KEAI Publishing in Journal of Clinical Insight
- Vol. 1
Virtual patients in digital oral healthcare: From multimodal integration to clinical translation
- 1 December 2026
- Published by KEAI Publishing in Journal of Clinical Insight
- Vol. 1
Open AccessVirtual patients in digital oral healthcare: From multimodal integration to clinical translation
- 6 October 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 18 (41) , 56910-56911
Correlation to “A Bioswitchable miRNA Delivery System: Tetrahedral Framework DNA-Based miRNA Delivery System for Applications in Wound Healing”
- 6 October 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 18 (41) , 56910-56911
Correlation to “A Bioswitchable miRNA Delivery System: Tetrahedral Framework DNA-Based miRNA Delivery System for Applications in Wound Healing”
- 1 September 2026
- Published by Springer Nature in Science China Chemistry
- Vol. 69 (11) , 6197-6223
Engineered nucleic acid nanostructures: biomedical innovations in oral healthcare
- 1 September 2026
- Published by Springer Nature in Science China Chemistry
- Vol. 69 (11) , 6197-6223
Engineered nucleic acid nanostructures: biomedical innovations in oral healthcare
- 3 August 2026
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 54 (10) , 109845
Pilot Study for Validation of Stereophotogrammetric and Mobile LiDAR Facial Scanning Against Vernier Caliper Measurements
- 3 August 2026
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 54 (10) , 109845
Pilot Study for Validation of Stereophotogrammetric and Mobile LiDAR Facial Scanning Against Vernier Caliper Measurements
- 30 July 2026
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (69)
An Enzyme‐Responsive Nucleic Acid‐Based Nanoassembly for Coordinated Co‐Delivery of microRNA and Puerarin in Osteoporotic Bone Regeneration
The repair of osteoporotic bone defects presents a formidable challenge due to the disrupted osteogenic‐adipogenic equilibrium within the bone marrow microenvironment. To address the limitations of monotherapies in regulating this pathological condition, this study engineers an enzyme‐responsive delivery platform, the puerarin‐reinforced nucleic acid‐based nanoassembly (Pue@NB), via structural reprogramming of tetrahedral framework nucleic acid (tFNA). This system enables precise co‐encapsulation and intracellular co‐delivery of osteogenic microRNA (miR‐335‐5p) and puerarin (Pue). While preserving the biocompatibility and cellular entry efficiency of tFNA, Pue@NB incorporates an embedded DNA‐RNA hybrid bio‐switch that responds to endogenous RNase H, enabling structural transformation and coordinated release of both therapeutic agents. In vitro, beyond promoting the migration of bone marrow mesenchymal stem cells (BMSCs), Pue@NB also exhibits a bidirectional regulatory capacity for BMSCs differentiation: its pro‐osteogenic and anti‐adipogenic effects are accompanied by increased hedgehog‐related signaling markers, upregulated TGF‐β1, and suppressed PPARγ/FABP4 expression. In an ovariectomy‐induced osteoporotic bone defect model, Pue@NB substantially accelerated bone regeneration, restored bone mineral density, and improved trabecular microstructure. This work elucidates a synergistic therapeutic strategy that integrates genetic and small‐molecule drugs via nucleic acid nanostructure reengineering, providing foundations for developing next‐generation dynamic nanomaterials for recalcitrant tissue defects.
- 30 July 2026
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (69)
An Enzyme‐Responsive Nucleic Acid‐Based Nanoassembly for Coordinated Co‐Delivery of microRNA and Puerarin in Osteoporotic Bone Regeneration
The repair of osteoporotic bone defects presents a formidable challenge due to the disrupted osteogenic‐adipogenic equilibrium within the bone marrow microenvironment. To address the limitations of monotherapies in regulating this pathological condition, this study engineers an enzyme‐responsive delivery platform, the puerarin‐reinforced nucleic acid‐based nanoassembly (Pue@NB), via structural reprogramming of tetrahedral framework nucleic acid (tFNA). This system enables precise co‐encapsulation and intracellular co‐delivery of osteogenic microRNA (miR‐335‐5p) and puerarin (Pue). While preserving the biocompatibility and cellular entry efficiency of tFNA, Pue@NB incorporates an embedded DNA‐RNA hybrid bio‐switch that responds to endogenous RNase H, enabling structural transformation and coordinated release of both therapeutic agents. In vitro, beyond promoting the migration of bone marrow mesenchymal stem cells (BMSCs), Pue@NB also exhibits a bidirectional regulatory capacity for BMSCs differentiation: its pro‐osteogenic and anti‐adipogenic effects are accompanied by increased hedgehog‐related signaling markers, upregulated TGF‐β1, and suppressed PPARγ/FABP4 expression. In an ovariectomy‐induced osteoporotic bone defect model, Pue@NB substantially accelerated bone regeneration, restored bone mineral density, and improved trabecular microstructure. This work elucidates a synergistic therapeutic strategy that integrates genetic and small‐molecule drugs via nucleic acid nanostructure reengineering, providing foundations for developing next‐generation dynamic nanomaterials for recalcitrant tissue defects.
- 27 July 2026
- Published by Springer Nature in Nature Protocols
- p. 1-31
A programmable DNA tetrahedron platform for selective and efficient capture of cells and proteins
- 27 July 2026
- Published by Springer Nature in Nature Protocols
- p. 1-31
A programmable DNA tetrahedron platform for selective and efficient capture of cells and proteins
- 16 July 2026
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 30 (8) , 331
Comparison of accuracy and reliability between smartphone and digital single-lens reflex camera in clinical dental photography: an in vivo study
Objectives This study aimed to determine whether flagship smartphones can approach the performance of professional digital single-lens reflex (DSLR) cameras using a standardized workflow incorporating color calibration and optical zoom. Methods Three DSLR cameras (Canon EOS 5D Mark IV, Canon EOS 80D, Nikon D610) and two smartphones (iPhone 17 Pro Max, Galaxy S24 Ultra) were used to capture nine standardized extraoral and intraoral views for each of 25 volunteers. Images were evaluated for color accuracy, dimensional accuracy, and image quality. Statistical analyses were conducted using one-way repeated-measures analysis of variance and paired t-tests, with Bonferroni correction applied for multiple comparisons (α = 0.05). Results Gray-card calibration significantly reduced smartphone image ΔE values (P < 0.001), resulting in lower ΔE values than those of the DSLR group with standardized white balance (P < 0.001). Regarding dimensional accuracy, images captured with the iPhone 17 Pro Max at 4× optical zoom showed no significant difference from DSLR cameras (P = 0.178), whereas the Samsung device significantly underestimated arch width (P = 0.041). Samsung achieved the most favorable BRISQUE score. Conclusions Under a standardized workflow incorporating color calibration and appropriate optical zoom, smartphone photography achieved gray-card-based color accuracy and relative dimensional consistency comparable to those of DSLR cameras, providing a more convenient and feasible imaging option. However, DSLR cameras still demonstrated advantages in clinically demanding aesthetic cases. Clinical relevance Using a standardized workflow that includes appropriate optical zoom, professional dental lighting, and gray-card-based color calibration, smartphone photography can achieve relatively satisfactory reproduction of dental color and dimensional consistency, representing a potentially reliable and cost-effective option for clinical documentation.
- 16 July 2026
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 30 (8) , 331
Comparison of accuracy and reliability between smartphone and digital single-lens reflex camera in clinical dental photography: an in vivo study
Objectives This study aimed to determine whether flagship smartphones can approach the performance of professional digital single-lens reflex (DSLR) cameras using a standardized workflow incorporating color calibration and optical zoom. Methods Three DSLR cameras (Canon EOS 5D Mark IV, Canon EOS 80D, Nikon D610) and two smartphones (iPhone 17 Pro Max, Galaxy S24 Ultra) were used to capture nine standardized extraoral and intraoral views for each of 25 volunteers. Images were evaluated for color accuracy, dimensional accuracy, and image quality. Statistical analyses were conducted using one-way repeated-measures analysis of variance and paired t-tests, with Bonferroni correction applied for multiple comparisons (α = 0.05). Results Gray-card calibration significantly reduced smartphone image ΔE values (P < 0.001), resulting in lower ΔE values than those of the DSLR group with standardized white balance (P < 0.001). Regarding dimensional accuracy, images captured with the iPhone 17 Pro Max at 4× optical zoom showed no significant difference from DSLR cameras (P = 0.178), whereas the Samsung device significantly underestimated arch width (P = 0.041). Samsung achieved the most favorable BRISQUE score. Conclusions Under a standardized workflow incorporating color calibration and appropriate optical zoom, smartphone photography achieved gray-card-based color accuracy and relative dimensional consistency comparable to those of DSLR cameras, providing a more convenient and feasible imaging option. However, DSLR cameras still demonstrated advantages in clinically demanding aesthetic cases. Clinical relevance Using a standardized workflow that includes appropriate optical zoom, professional dental lighting, and gray-card-based color calibration, smartphone photography can achieve relatively satisfactory reproduction of dental color and dimensional consistency, representing a potentially reliable and cost-effective option for clinical documentation.
Non‐Invasive Transdermal Delivery of miR‐30a‐5p via MUC1‐Aptamer‐Guided Tetrahedral DNA Nanostructures for Gene Silencing in Cutaneous Melanoma
Cutaneous malignant melanoma is a highly aggressive skin cancer with poor prognosis. Although microRNA (miRNA)‐based gene therapy shows promise, its clinical translation is limited by rapid degradation in serum and the barrier function of the stratum corneum. Herein, we engineer a programmable, targeted, and non‐invasive nanoplatform, termed MARS (MUC1‐Aptamer‐functionalized, tetrahedral framework nucleic acid‐based miRNA delivery system for gene Silencing). The therapeutic miR‐30a‐5p is encapsulated within a self‐assembled DNA tetrahedron, an architecture that confers exceptional structural stability. The framework is specifically functionalized with an MUC1 aptamer to act as a navigator for active tumor targeting while simultaneously carrying the gene‐silencing payload. In vitro assays demonstrate that MARS successfully delivers miR‐30a‐5p into A375 cells, effectively silencing the transcription factor E2F7 and subsequently triggering the intrinsic apoptotic pathway. Importantly, in vivo studies using a xenograft mouse model reveal that topically applied MARS can penetrate the skin barrier and accumulate in tumor tissues, achieving a tumor growth inhibition rate of 66.86%, comparable to intravenous anti‐PD‐L1 immunotherapy but with superior safety, compliance, and cost‐effectiveness. This study presents MARS as a robust strategy that integrates stability, programmable dual‐functionality (targeting and gene silencing), and non‐invasive transdermal capabilities, providing a promising strategy for localized melanoma treatment.
Non‐Invasive Transdermal Delivery of miR‐30a‐5p via MUC1‐Aptamer‐Guided Tetrahedral DNA Nanostructures for Gene Silencing in Cutaneous Melanoma
Cutaneous malignant melanoma is a highly aggressive skin cancer with poor prognosis. Although microRNA (miRNA)‐based gene therapy shows promise, its clinical translation is limited by rapid degradation in serum and the barrier function of the stratum corneum. Herein, we engineer a programmable, targeted, and non‐invasive nanoplatform, termed MARS (MUC1‐Aptamer‐functionalized, tetrahedral framework nucleic acid‐based miRNA delivery system for gene Silencing). The therapeutic miR‐30a‐5p is encapsulated within a self‐assembled DNA tetrahedron, an architecture that confers exceptional structural stability. The framework is specifically functionalized with an MUC1 aptamer to act as a navigator for active tumor targeting while simultaneously carrying the gene‐silencing payload. In vitro assays demonstrate that MARS successfully delivers miR‐30a‐5p into A375 cells, effectively silencing the transcription factor E2F7 and subsequently triggering the intrinsic apoptotic pathway. Importantly, in vivo studies using a xenograft mouse model reveal that topically applied MARS can penetrate the skin barrier and accumulate in tumor tissues, achieving a tumor growth inhibition rate of 66.86%, comparable to intravenous anti‐PD‐L1 immunotherapy but with superior safety, compliance, and cost‐effectiveness. This study presents MARS as a robust strategy that integrates stability, programmable dual‐functionality (targeting and gene silencing), and non‐invasive transdermal capabilities, providing a promising strategy for localized melanoma treatment.
- 30 December 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
An Immunomodulatory DNA Hydrogel Based on Tetrahedral Framework Nucleic Acids for Treating Psoriasis
Psoriasis represents a persistent immune-mediated dermatological disorder for which no curative therapy is currently available, imposing a considerable burden on affected individuals and healthcare resources. And aberrant macrophage activation is one of the main factors influencing the course of psoriasis. However, safe and drug-free strategy to modulate macrophages is still urgently needed. Here, we developed a tetrahedral framework DNA-based hydrogel (TDH), which was constructed via the self-assembly of sticky-ended tetrahedral DNA nanostructures (TDNs). TDH exhibited robust mechanical strength, injectability, and self-healing properties, demonstrating advantages over conventional DNA hydrogels. TDH markedly downregulated pro-inflammatory cytokine and chemokine levels in macrophages activated by lipopolysaccharide (LPS). Furthermore, a widespread reprogramming of inflammatory signaling networks was shown by transcriptome analysis. Clinical symptoms were significantly reduced by topical TDH application in an imiquimod-induced psoriasis mouse model in vivo, which also decreased the infiltration of immune cells and both epidermal hyperplasia, and successfully resulted in immune homeostasis. Importantly, this effect was achieved without systemic toxicity. Collectively, this study establishes TDH as a biocompatible, programmable, and drug-free immunoregulatory platform, which provides a strategy for the application of nucleic acid-based biomaterials in dermatological therapy.
- 30 December 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
An Immunomodulatory DNA Hydrogel Based on Tetrahedral Framework Nucleic Acids for Treating Psoriasis
Psoriasis represents a persistent immune-mediated dermatological disorder for which no curative therapy is currently available, imposing a considerable burden on affected individuals and healthcare resources. And aberrant macrophage activation is one of the main factors influencing the course of psoriasis. However, safe and drug-free strategy to modulate macrophages is still urgently needed. Here, we developed a tetrahedral framework DNA-based hydrogel (TDH), which was constructed via the self-assembly of sticky-ended tetrahedral DNA nanostructures (TDNs). TDH exhibited robust mechanical strength, injectability, and self-healing properties, demonstrating advantages over conventional DNA hydrogels. TDH markedly downregulated pro-inflammatory cytokine and chemokine levels in macrophages activated by lipopolysaccharide (LPS). Furthermore, a widespread reprogramming of inflammatory signaling networks was shown by transcriptome analysis. Clinical symptoms were significantly reduced by topical TDH application in an imiquimod-induced psoriasis mouse model in vivo, which also decreased the infiltration of immune cells and both epidermal hyperplasia, and successfully resulted in immune homeostasis. Importantly, this effect was achieved without systemic toxicity. Collectively, this study establishes TDH as a biocompatible, programmable, and drug-free immunoregulatory platform, which provides a strategy for the application of nucleic acid-based biomaterials in dermatological therapy.
- 5 December 2025
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 27 (6) , e70101
Effects of Three‐Dimensional Print Offsets of Sleeves on Implant Placement Trueness: An In Vitro Study
Introduction: This study assesses the effects of different three‐dimensional (3D) print offsets of sleeves on sleeve and implant placement trueness in guided implant surgery. Methods: Twenty‐five sleeves were installed on 3D‐printed surgical guides, with sleeve offsets of 0.02, 0.04, 0.06, 0.08, and 0.10 mm (five groups with five sleeves per group). The actual surgical guides were scanned to generate digital files, which were compared with the reference group based on design positions. The experimental verification and evaluation method involves assessing sleeve installations and measuring the deviations between the actual position of the sleeve and implant compared with the reference group. Results: The sleeve installations in the 0.02‐mm offset group were not acceptable, as there were visible cracks in the sleeve; in the case of the 0.04‐mm offset group, there were also installation difficulties. At the sleeve position level, there were larger deviations in the 0.10‐mm offset group, whereas the 0.08‐mm group had smaller deviations in the labial and palatal directions ( p < 0.05). At the implant level, the 0.10‐mm offset group showed a significantly larger deviation (labial: 0.453 ± 0.165 mm; palatal: 0.399 ± 0.160 mm; p < 0.05). As for the mesial–distal direction, there were no significant differences between the groups. Conclusions: Print offsets of sleeves had a significant effect on the ease of installation and the placement accuracy of sleeves and implants. Under the printer and sleeves conditions used in this experiment, smaller offsets (0.02 and 0.04 mm) caused installation difficulties and misalignments. Larger offsets (0.10 mm) created noticeable deviations. Sleeve offsets of 0.06 and 0.08 mm provided a balance between ease of installation and high placement trueness, making them more suitable in this experiment. Excessive or insufficient print offsets of sleeves can affect installation conditions and positional trueness of sleeves and implants.
- 5 December 2025
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 27 (6) , e70101
Effects of Three‐Dimensional Print Offsets of Sleeves on Implant Placement Trueness: An In Vitro Study
Introduction: This study assesses the effects of different three‐dimensional (3D) print offsets of sleeves on sleeve and implant placement trueness in guided implant surgery. Methods: Twenty‐five sleeves were installed on 3D‐printed surgical guides, with sleeve offsets of 0.02, 0.04, 0.06, 0.08, and 0.10 mm (five groups with five sleeves per group). The actual surgical guides were scanned to generate digital files, which were compared with the reference group based on design positions. The experimental verification and evaluation method involves assessing sleeve installations and measuring the deviations between the actual position of the sleeve and implant compared with the reference group. Results: The sleeve installations in the 0.02‐mm offset group were not acceptable, as there were visible cracks in the sleeve; in the case of the 0.04‐mm offset group, there were also installation difficulties. At the sleeve position level, there were larger deviations in the 0.10‐mm offset group, whereas the 0.08‐mm group had smaller deviations in the labial and palatal directions ( p < 0.05). At the implant level, the 0.10‐mm offset group showed a significantly larger deviation (labial: 0.453 ± 0.165 mm; palatal: 0.399 ± 0.160 mm; p < 0.05). As for the mesial–distal direction, there were no significant differences between the groups. Conclusions: Print offsets of sleeves had a significant effect on the ease of installation and the placement accuracy of sleeves and implants. Under the printer and sleeves conditions used in this experiment, smaller offsets (0.02 and 0.04 mm) caused installation difficulties and misalignments. Larger offsets (0.10 mm) created noticeable deviations. Sleeve offsets of 0.06 and 0.08 mm provided a balance between ease of installation and high placement trueness, making them more suitable in this experiment. Excessive or insufficient print offsets of sleeves can affect installation conditions and positional trueness of sleeves and implants.