Simin Arshi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Simin Arshi has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Edmond Magner
Department of Chemical Sciences, Bernal Institute University of Limerick V94 T9PX, Limerick, Ireland
2 shared publications - Babak Karimi
Institute for Advanced Studies in Basic Sciences (IASBS)
1 shared publication - Fei Shen
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China
1 shared publication Hojatollah Vali
Department of Anatomy & Cell Biology, McGill University, 3640 University St., Montréal, Quebec, Canada
1 shared publication- Jens Ulstrup
Department of Chemistry, Technical University of Denmark, 2800 Kongens Lyngby, Denmark
1 shared publication - Mandana Amiri
University of Mohaghegh Ardabili
1 shared publication
Latest Publications
- Open Access
- 27 October 2022
- Published by Elsevier in Synthetic Metals
- Vol. 291, 117205
One-step electrochemical approach of enzyme immobilization for bioelectrochemical applications
- 27 October 2022
- Published by Elsevier in Synthetic Metals
- Vol. 291, 117205
Open AccessOne-step electrochemical approach of enzyme immobilization for bioelectrochemical applications
- Open Access
Enzymatic Bioreactors: An Electrochemical Perspective
Biocatalysts provide a number of advantages such as high selectivity, the ability to operate under mild reaction conditions and availability from renewable resources that are of interest in the development of bioreactors for applications in the pharmaceutical and other sectors. The use of oxidoreductases in biocatalytic reactors is primarily focused on the use of NAD(P)-dependent enzymes, with the recycling of the cofactor occurring via an additional enzymatic system. The use of electrochemically based systems has been limited. This review focuses on the development of electrochemically based biocatalytic reactors. The mechanisms of mediated and direct electron transfer together with methods of immobilising enzymes are briefly reviewed. The use of electrochemically based batch and flow reactors is reviewed in detail with a focus on recent developments in the use of high surface area electrodes, enzyme engineering and enzyme cascades. A future perspective on electrochemically based bioreactors is presented.
Open AccessEnzymatic Bioreactors: An Electrochemical Perspective
Biocatalysts provide a number of advantages such as high selectivity, the ability to operate under mild reaction conditions and availability from renewable resources that are of interest in the development of bioreactors for applications in the pharmaceutical and other sectors. The use of oxidoreductases in biocatalytic reactors is primarily focused on the use of NAD(P)-dependent enzymes, with the recycling of the cofactor occurring via an additional enzymatic system. The use of electrochemically based systems has been limited. This review focuses on the development of electrochemically based biocatalytic reactors. The mechanisms of mediated and direct electron transfer together with methods of immobilising enzymes are briefly reviewed. The use of electrochemically based batch and flow reactors is reviewed in detail with a focus on recent developments in the use of high surface area electrodes, enzyme engineering and enzyme cascades. A future perspective on electrochemically based bioreactors is presented.
- 16 March 2020
- Published by Wiley in Electroanalysis
- Vol. 32 (7) , 1391-1407
An Overview on Electrochemical Determination of Cholesterol
Cholesterol detection is of great significance in biomedical applications because it is a crucial biomarker for some diseases. It is the precursor of different biological compounds such as vitamin D, hormones, and bile acid, etc. The cholesterol level in blood correlated to various diseases such as hypolipoproteinaemia, septicaemia, malnutrition hypertension, anaemia, brain thrombosis and arteriosclerosis for instance its levels in the blood of more than 200 mg/dL, increase the risk of heart disease. It is also found in foods from animal origin such as milk, meat, cheese, egg and seafood. With respect to dietary reference value for cholesterol intake, most of food safety authorities recommended maximum intake 300 mg per day for adults. Consequently, cholesterol is considered as a critical indicator of clinical biochemistry and so introducing new techniques for determination of it in biological samples and food is important. In this review, Principles, methods and recent developments in electrochemical cholesterol sensors are reviewed. Special attention is given to the discussion on some problems and bottlenecks in areas of enzymatic cholesterol sensing and new advances in non‐enzymatic sensors.
- 16 March 2020
- Published by Wiley in Electroanalysis
- Vol. 32 (7) , 1391-1407
An Overview on Electrochemical Determination of Cholesterol
Cholesterol detection is of great significance in biomedical applications because it is a crucial biomarker for some diseases. It is the precursor of different biological compounds such as vitamin D, hormones, and bile acid, etc. The cholesterol level in blood correlated to various diseases such as hypolipoproteinaemia, septicaemia, malnutrition hypertension, anaemia, brain thrombosis and arteriosclerosis for instance its levels in the blood of more than 200 mg/dL, increase the risk of heart disease. It is also found in foods from animal origin such as milk, meat, cheese, egg and seafood. With respect to dietary reference value for cholesterol intake, most of food safety authorities recommended maximum intake 300 mg per day for adults. Consequently, cholesterol is considered as a critical indicator of clinical biochemistry and so introducing new techniques for determination of it in biological samples and food is important. In this review, Principles, methods and recent developments in electrochemical cholesterol sensors are reviewed. Special attention is given to the discussion on some problems and bottlenecks in areas of enzymatic cholesterol sensing and new advances in non‐enzymatic sensors.
- 9 December 2013
- Published by Royal Society of Chemistry (RSC) in Dalton Transactions
- Vol. 43 (12) , 4901-4908
Ethylenediamine-modified oriented MCM-41 at the electrode surface, cobalt adsorption ability and electrochemical performance
Mesoporous silica thin films (MCM-41) functionalized with ethylenediamine groups were electrochemically fabricated on electrode surfaces. These ligand functionalized film were a promising matrix for the immobilization of cobalt ions and preparation of cobalt complexes covalently bound to the MCM-41 support. The constructed MCM-41 were characterized by TEM, EDS and TGA analysis. This method yields uniform thin films with hexagonal mesochannels aligned and accessible to electrode surface. Well-defined electrode responses were, therefore, observed for the anchored complexes which made the electrochemical analysis of the structure possible as well. Voltammetric studies revealed the reactivity of the covalently bound complexes differed significantly from the dissolved ones. The anchored complexes preferred to be in their oxidized form which inhibits formation of oxygen adducts. The covalently bound complexes had relatively good leaching stability with good catalytic performance towards hydrogen peroxide reduction.
- 9 December 2013
- Published by Royal Society of Chemistry (RSC) in Dalton Transactions
- Vol. 43 (12) , 4901-4908
Ethylenediamine-modified oriented MCM-41 at the electrode surface, cobalt adsorption ability and electrochemical performance
Mesoporous silica thin films (MCM-41) functionalized with ethylenediamine groups were electrochemically fabricated on electrode surfaces. These ligand functionalized film were a promising matrix for the immobilization of cobalt ions and preparation of cobalt complexes covalently bound to the MCM-41 support. The constructed MCM-41 were characterized by TEM, EDS and TGA analysis. This method yields uniform thin films with hexagonal mesochannels aligned and accessible to electrode surface. Well-defined electrode responses were, therefore, observed for the anchored complexes which made the electrochemical analysis of the structure possible as well. Voltammetric studies revealed the reactivity of the covalently bound complexes differed significantly from the dissolved ones. The anchored complexes preferred to be in their oxidized form which inhibits formation of oxygen adducts. The covalently bound complexes had relatively good leaching stability with good catalytic performance towards hydrogen peroxide reduction.