LYLiuqing Yang

Liuqing Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Liuqing Yang has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Mechanosensitive Ca 2+ channel TRPV1 activated by low‐intensity pulsed ultrasound ameliorates acute kidney injury through Notch1‐Akt‐ eNOS signaling

    by Qi Huangfu, Jun Zhang, Jiaju Xu, Jinming Xu, Zhangcheng Yang, Jingchao Wei, Liuqing Yang, Yichang Shu, Chengfang Sun, Bohan Wang, et al.

    Acute Kidney Injury (AKI) is a significant medical condition characterized by the abrupt decline in kidney function.Low‐intensity pulsed ultrasound (LIPUS), a non‐invasive therapeutic technique employing low‐intensity acoustic wave pulses, has shown promise in promoting tissue repair and regeneration. A novel LIPUS system was developed and evaluated in rat AKI models, focusing on its effects on glomerular filtration rate (GFR), blood urea nitrogen (BUN), serum creatinine (SCr), and the Notch1‐Akt‐eNOS signaling pathway. The results demonstrated that LIPUS treatment improved GFR, BUN, SCr levels, and renal pathology in AKI rats. In vitro experiments using HUVEC cells revealed that LIPUS stimulation promoted angiogenesis, cell migration mechanically‐dependent calcium ion influx, which was partially attenuated by TRPV1 knockdown. RNA sequencing analysis indicated LIPUS‐induced activation of the Notch pathway, phosphorylation of Akt and eNOS. Furthermore, inhibition or genetic silencing of Notch1 abolished the beneficial effects of LIPUS on angiogenesis, renal function, and Akt‐eNOS phosphorylation in both cells and AKI rats. These findings suggest that LIPUS‐induced calcium influx promotes Akt‐eNOS phosphorylation, nitric oxide (NO) production, angiogenesis, and improved renal function in AKI via Notch1‐Akt‐eNOS signaling, positioning LIPUS as a promising therapeutic strategy for AKI by targeting vascular regeneration.


  • A self-reciprocity calibration of spherical transducers using boundary reflection in a spherical shell

    by Liuqing Yang, Jun Zhang

    A self-reciprocity method is described for calibrating a spherical transducer in a spherical shell. The reciprocity constant is calculated using Green's function and the electroacoustic reciprocal principle in the spherical shell. A sensitivity correction is developed by calculating the transducer's receiving force in different fields. An experimental measurement setup is described to calibrate transducers with diameters of 20 and 30 mm in the frequency range from 25 to 63 kHz, calibrated in a 500 mm diameter spherical shell with a thickness of 2 mm. The largest discrepancy in calibration results between the self-reciprocity and three-transducer spherical-wave reciprocity method is around −1.4 dB. The self-reciprocity calibration method, with a smaller volume required than the three-transducer spherical-wave reciprocity method, has a potential advantage in calibrating the transducer at high hydrostatic pressure and varying water temperatures.


  • Calibration of hydrophones using a frequency domain filter processing method: theory and experiment

    by Yi Chen, Liuqing Yang, Lisheng Zhou, Xiaofeng Jin, Guanghui Jia

    To eliminate the interferences coming from the boundaries of a water tank and extend its low frequency calibration limit, a frequency domain filter processing (FDFP) method is proposed for hydrophone calibration measurements. The frequency domain filter function is designed according to the a priori spatial position of projector and hydrophone pair in a water tank. A simultaneous comparison method is used for calibration, and a wideband pink noise pulse signal is transmitted. After application of the FDFP method, the transfer impedances of projector and hydrophone pairs in a quasi-free-field are obtained, and interferences reflected from the boundaries of the water tank are effectively eliminated. To verify the FDFP method, an experimental system is established for calibration of the free-field sensitivity of a TC 4033 hydrophone. For a non-anechoic water tank of 1.5 m × 0.88 m × 0.90 m, the lowest calibration frequency is extended from 20 kHz to 3.15 kHz, and the calibration result is consistent with the free-field reciprocity calibration result obtained in an anechoic water tank of 50 m × 15 m × 10 m in the frequency range 3.15 kHz to 31.5 kHz.


  • Open Access

    Calibration of echosounder using standard target method

    by Liuqing Yang, Yi Chen, Jun Zhang

    In this work, we develop an underwater echosounder and use the standard target method to calibrate the performance of the device. In the calibration experiments, a solid tungsten carbide sphere of 38mm diameter is used as a standard target for calibrating a HPCTB-200-35 echosounder (manufactured by Hangzhou Applied Acoustics Research Institute) with a working frequency of 220 kHz. Further, the measurement data and uncertainty are presented and analyzed; these results demonstrate that the standard target method can calibrate the combined transmitting-receiving response of echosounders effectively. In our calibration experiment, the combined transmitting-receiving response of HPCTB-200-35 is about 33.8 dB, and the measurement uncertainty is about 1.0 dB (k = 2).