Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shahid Iqbal has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Ahsan Ali

    Department of Civil Engineering, University of Applied Sciences, Leipzig, Germany

    1 shared publication
  • Chen Yaqin

    School of Civil Engineering and Architecture, Xi’an University of Technology, Xi’an, China

    1 shared publication
  • Inamullah Khan

    National Institute of Transportation National University of Sciences and Technology (NUST) Islamabad Pakistan nust.edu.pk

    1 shared publication
  • N. Ullah

    Department of Civil Engineering, CECOS University of Information Technology and Emerging Sciences, Peshawar, Pakistan

    1 shared publication
  • Saud Ul Haq

    Department of Civil Engineering, Sarhad University of Science and Information Technology, Peshawar, Pakistan

    1 shared publication
  • Shah Room

    School of Computing and Engineering, University of West London, London, UK

    1 shared publication

Latest Publications

  • Open Access

    Performance evaluation of indented macro synthetic polypropylene fibers in high strength self-compacting concrete (SCC)

    by Chen Yaqin, Saud Ul Haq, Shahid Iqbal, Inamullah Khan, Shah Room, Shaukat Ali Khan

    Concrete is used worldwide as a construction material in many projects. It exhibits a brittle nature, and fibers' addition to it improves its mechanical properties. Polypropylene (PP) fibers stand out as widely employed fibers in concrete. However, conventional micro-PP fibers pose challenges due to their smooth texture, affecting bonding within concrete and their propensity to clump during mixing due to their thin and soft nature. Addressing these concerns, a novel type of PP fiber is proposed by gluing thin fibers jointly and incorporating surface indentations to enhance mechanical anchorage. This study investigates the incorporation of macro-PP fibers into high-strength concrete, examining its fresh and mechanical properties. Three different concrete strengths 40 MPa, 45 MPa, and 50 MPa, were studied with fiber content of 0–1.5% v/f. ASTM specifications were utilized to test the fresh and mechanical properties, while the RILEM specifications were adopted to test the bond of bar reinforcements in concrete. Test results indicate a decrease in workability, increased air content, and no substantial shift in fresh concrete density. Hardened concrete tests, adding macro-PP fibers, show a significant increase in splitting tensile strength, bond strength, and flexural strength with a maximum increase of 34.5%, 35%, and 100%, respectively. Concrete exhibits strain-hardening behavior with 1% and 1.5% fiber content, and the flexural toughness increases remarkably from 2.2 to 47.1. Thus, macro PP fibers can effectively improve concrete's mechanical properties and resistance against crack initiation and spread.


  • Open Access

    Effect of Maximum Aggregate Size on the Bond Strength of Reinforcements in Concrete

    by S. Iqbal, N. Ullah, A. Ali

    The bond between reinforcements and concrete is the only mechanism that transfers the tensile stresses from concrete to reinforcements. Several factors including chemical adhesion, roughness and reinforcement interface and bar bearing affect the bond strength of reinforcements with concrete. This work was carried out considering another varying factor which is maximum aggregate size. Four mixes of concrete with similar compressive strengths but different maximum aggregate sizes of 25.4mm, 19.05mm, 12.7mm and 9.53mm were used with the same bar size of 16mm. Compressive strength, splitting tensile strength and bond strength for each concrete mix were studied. Test results depict a slight increase in compressive and splitting tensile strength with decrease in maximum aggregate size. The bond strength remained at the same level with decrease in maximum aggregate size except at maximum aggregate size of 9.53mm when there was a drop in bond strength, despite better compressive and splitting tensile strengths. ACI-318 and FIB-2010 codes equation for bond strength calculation work well only when the maximum aggregate size is 12.7mm and above. Therefore, maximum aggregate size is critical for bond strength when smaller size aggregates are used.