Latest Publications
- 1 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Modélisation de la ventilation naturelle en vue d'une conception optimisée d'ouvertures vitrées
La ventilation naturelle est une solution passive de rafraichissement des bâtiments dont la performance est souvent limitée par des contraintes acoustiques et visuelles. Les travaux de cette thèse visent à améliorer la conception des ouvertures vitrées pour intégrer ces multiples contraintes. Des modèles thermo-aéraulique, acoustique et d'éclairement sont intégrés dans une plate-forme de simulation énergétique du bâtiment afin d'évaluer la performance de la ventilation naturelle dans des bâtiments tertiaires et résidentiels en termes de confort global et de consommation énergétique. La thèse contribue en particulier au développement et à la validation de modèles thermo-aérauliques à partir d'essais expérimentaux et de la simulation numérique. Une nouvelle technique de mesure du taux de renouvellement d'air par gaz traceur est développée en conditions de laboratoire puis appliquée dans une campagne d'essais in-situ pour caractériser l'écoulement d'air en ventilation traversante et mono-façade. Des simulations numériques ont été menées pour analyser les écarts observés entre les mesures et les corrélations. A l'aide de la CFD, des géométries d'ouverture spécifiques au cas d'étude (présence de loggia, tailles différentes de fenêtres) sous différentes conditions de vent permettent d'identifier les plages d'application des corrélations. Enfin, des simulations énergétiques du bâtiment intégrant les modèles développés et comparant différents modes de gestion sont effectuées en bâtiment de bureaux et résidentiel. On observe une réduction importante du potentiel de rafraichissement dans un environnement bruyant. Des prototypes de volets acoustiques sont conçus pour assurer un compromis entre confort thermique et acoustique. Des indicateurs applicables à la conception des ouvertures vitrées en fonction de paramètres climatiques sont également proposés.
- 1 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Modélisation de la ventilation naturelle en vue d'une conception optimisée d'ouvertures vitrées
La ventilation naturelle est une solution passive de rafraichissement des bâtiments dont la performance est souvent limitée par des contraintes acoustiques et visuelles. Les travaux de cette thèse visent à améliorer la conception des ouvertures vitrées pour intégrer ces multiples contraintes. Des modèles thermo-aéraulique, acoustique et d'éclairement sont intégrés dans une plate-forme de simulation énergétique du bâtiment afin d'évaluer la performance de la ventilation naturelle dans des bâtiments tertiaires et résidentiels en termes de confort global et de consommation énergétique. La thèse contribue en particulier au développement et à la validation de modèles thermo-aérauliques à partir d'essais expérimentaux et de la simulation numérique. Une nouvelle technique de mesure du taux de renouvellement d'air par gaz traceur est développée en conditions de laboratoire puis appliquée dans une campagne d'essais in-situ pour caractériser l'écoulement d'air en ventilation traversante et mono-façade. Des simulations numériques ont été menées pour analyser les écarts observés entre les mesures et les corrélations. A l'aide de la CFD, des géométries d'ouverture spécifiques au cas d'étude (présence de loggia, tailles différentes de fenêtres) sous différentes conditions de vent permettent d'identifier les plages d'application des corrélations. Enfin, des simulations énergétiques du bâtiment intégrant les modèles développés et comparant différents modes de gestion sont effectuées en bâtiment de bureaux et résidentiel. On observe une réduction importante du potentiel de rafraichissement dans un environnement bruyant. Des prototypes de volets acoustiques sont conçus pour assurer un compromis entre confort thermique et acoustique. Des indicateurs applicables à la conception des ouvertures vitrées en fonction de paramètres climatiques sont également proposés.
- Open Access
- 25 July 2023
- Published by Elsevier in Applied Thermal Engineering
- Vol. 234
Benchmarking metal-organic framework coatings from Large-Temperature-Jump experiments: Learning from trade-offs in mean powers versus characteristic times
- 25 July 2023
- Published by Elsevier in Applied Thermal Engineering
- Vol. 234
Open AccessBenchmarking metal-organic framework coatings from Large-Temperature-Jump experiments: Learning from trade-offs in mean powers versus characteristic times
- 1 October 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 161
Heat properties of a hydrophilic carboxylate-based MOF for water adsorption applications
- 1 October 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 161
Heat properties of a hydrophilic carboxylate-based MOF for water adsorption applications
- Open Access
- 1 September 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 609 (5) , 052013
Performance comparison between metal-organic framework (MOFs) and conventional desiccants (silica gel, zeolite) for a novel high temperature cooling system
The use of desiccant-coated heat exchangers (DCHE) in air conditioning systems possesses great advantages in the independent control of both temperature and humidity, as well as low energy consumption and high coefficient of performance (COP). The paper presents a novel high temperature cooling system that uses metal-organic frameworks (MOFs) as sorbents for humidity control. MOFs are a new class of porous crystalline materials consisted of metal clusters and organic linkers, which have an excellent performance of water sorption due to the large specific surface areas and high porosity. In this research, we directly coat MOFs on the heat exchange surface of evaporator and condenser. The evaporator can simultaneously remove both the sensible and latent loads of the incoming air without reducing the temperature below its dew point. The regeneration of wet MOFs is completely driven by the residual heat from the condenser. We also make comparison between the MOF-coated cooling system and conventional desiccants coated ones (i.e. silica gel, zeolite) by way of tests and calculation. The results indicate that the dehumidification capacity of the MOF-coated heat exchanger outperforms other conventional desiccant coated ones under low regeneration temperature (∼50°C). The MOF-coated system has a high COP, up to 7.9, and can save 36.1% of the energy required, compared to the traditional vapour compression system with reheating. The amphiphilic MOFs used in the study have high water uptake and low regeneration temperature, and they thus have the potential for being scaled up for large-scale applications in energy efficient air conditioning systems.
- 1 September 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 609 (5) , 052013
Open AccessPerformance comparison between metal-organic framework (MOFs) and conventional desiccants (silica gel, zeolite) for a novel high temperature cooling system
The use of desiccant-coated heat exchangers (DCHE) in air conditioning systems possesses great advantages in the independent control of both temperature and humidity, as well as low energy consumption and high coefficient of performance (COP). The paper presents a novel high temperature cooling system that uses metal-organic frameworks (MOFs) as sorbents for humidity control. MOFs are a new class of porous crystalline materials consisted of metal clusters and organic linkers, which have an excellent performance of water sorption due to the large specific surface areas and high porosity. In this research, we directly coat MOFs on the heat exchange surface of evaporator and condenser. The evaporator can simultaneously remove both the sensible and latent loads of the incoming air without reducing the temperature below its dew point. The regeneration of wet MOFs is completely driven by the residual heat from the condenser. We also make comparison between the MOF-coated cooling system and conventional desiccants coated ones (i.e. silica gel, zeolite) by way of tests and calculation. The results indicate that the dehumidification capacity of the MOF-coated heat exchanger outperforms other conventional desiccant coated ones under low regeneration temperature (∼50°C). The MOF-coated system has a high COP, up to 7.9, and can save 36.1% of the energy required, compared to the traditional vapour compression system with reheating. The amphiphilic MOFs used in the study have high water uptake and low regeneration temperature, and they thus have the potential for being scaled up for large-scale applications in energy efficient air conditioning systems.
- 1 November 2018
- Published by Elsevier in Building and Environment
- Vol. 145, 234-242
Metal-organic framework MIL-100(Fe) as a novel moisture buffer material for energy-efficient indoor humidity control
- 1 November 2018
- Published by Elsevier in Building and Environment
- Vol. 145, 234-242
Metal-organic framework MIL-100(Fe) as a novel moisture buffer material for energy-efficient indoor humidity control
- Open Access
- 16 October 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-9
Metal-Organic Frameworks as advanced moisture sorbents for energy-efficient high temperature cooling
Latent cooling load accounts for 30% of the total load of air-conditioning, and its proportion is even higher in many tropical and subtropical climates. Traditional vapour-compression air-conditioning (VCAC) has a low coefficient of performance (COP) due to the refrigeration dehumidification process, which often makes necessary a great deal of subsequent re-heating. Technologies using conventional desiccants or sorbents for indoor moisture control are even less competitive than VCAC due to their high regeneration temperature, long cycling time and bulky components. Here, we report a novel high temperature cooling system that uses porous metal-organic frameworks (MOFs) as advanced sorbents for humidity control. We directly coat MOFs on the surface of evaporator and condenser. The system has no additional components compared to a traditional VCAC. The evaporator can simultaneously remove both the sensible and latent loads of the incoming air without reducing the temperature below its dew point. The regeneration of wet MOFs is completely driven by the residual heat from the condenser. The MOF-coated heat exchangers can achieve a cooling power density of 82 W·L −1 . We demonstrate that the system has a high COP, up to 7.9, and can save 36.1% of the energy required, compared to the traditional VCAC system with reheating. The amphiphilic MOFs used in the research have high water uptake, are made of low-cost raw materials and have high hydrothermal stability. They thus have the potential for being scaled up for large-scale applications in air conditioning.
- 16 October 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-9
Open AccessMetal-Organic Frameworks as advanced moisture sorbents for energy-efficient high temperature cooling
Latent cooling load accounts for 30% of the total load of air-conditioning, and its proportion is even higher in many tropical and subtropical climates. Traditional vapour-compression air-conditioning (VCAC) has a low coefficient of performance (COP) due to the refrigeration dehumidification process, which often makes necessary a great deal of subsequent re-heating. Technologies using conventional desiccants or sorbents for indoor moisture control are even less competitive than VCAC due to their high regeneration temperature, long cycling time and bulky components. Here, we report a novel high temperature cooling system that uses porous metal-organic frameworks (MOFs) as advanced sorbents for humidity control. We directly coat MOFs on the surface of evaporator and condenser. The system has no additional components compared to a traditional VCAC. The evaporator can simultaneously remove both the sensible and latent loads of the incoming air without reducing the temperature below its dew point. The regeneration of wet MOFs is completely driven by the residual heat from the condenser. The MOF-coated heat exchangers can achieve a cooling power density of 82 W·L −1 . We demonstrate that the system has a high COP, up to 7.9, and can save 36.1% of the energy required, compared to the traditional VCAC system with reheating. The amphiphilic MOFs used in the research have high water uptake, are made of low-cost raw materials and have high hydrothermal stability. They thus have the potential for being scaled up for large-scale applications in air conditioning.
- 1 September 2016
- Published by Elsevier in Building and Environment
- Vol. 106, 131-142
Numerical simulation of wind-driven natural ventilation: Effects of loggia and facade porosity on air change rate
- 1 September 2016
- Published by Elsevier in Building and Environment
- Vol. 106, 131-142
Numerical simulation of wind-driven natural ventilation: Effects of loggia and facade porosity on air change rate
- Top Cited Papers
- 1 January 2015
- Published by Elsevier in Building and Environment
- Vol. 84, 162-169
CO2 tracer gas concentration decay method for measuring air change rate
- 1 January 2015
- Published by Elsevier in Building and Environment
- Vol. 84, 162-169
Top Cited PapersCO2 tracer gas concentration decay method for measuring air change rate