Cheng-Yi Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cheng-Yi Huang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Bei-Yu Wang
Department of Orthopedic Surgery, West China Hospital, Sichuan University, Chengdu, China
1 shared publication - Bei-Yu Wang
Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China
1 shared publication - Chen Ding
Department of Orthopedic Surgery, West China Hospital, Sichuan University, No. 37 Guo Xue Xiang, Chengdu, 610041, Sichuan, China
1 shared publication - Chen Ding
Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China
1 shared publication - Hao Liu
Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, No. 37 Guo Xue Rd, Chengdu 610041, China
1 shared publication - Hao Liu
Department of Orthopedic surgery and Orthopedic Research Institute, West China Hospital Sichuan University Chengdu China
1 shared publication
Latest Publications
- 16 April 2025
- Published by Springer Nature in European Spine Journal
- Vol. 34 (6) , 2290-2300
Clinical and biomechanical effects of bone-implant interface gap after cervical disc replacement
Purpose Due to the irregularity of cervical inferior endplate morphology among individuals and segments, a bone-implant interface (BII) gap is usually unavoidable between the prosthesis and endplate after cervical disc replacement (CDR). This study aimed to investigate the clinical and biomechanical effects of the BII gap after CDR. Methods We retrospectively reviewed the clinical and radiological data of 180 patients who underwent 1-level or 2-level CDR. Cervical sagittal parameters, implant subsidence and migration, heterotopic ossification (HO) were evaluated through lateral radiographs. Endplate morphology was classified into three types according to the position of concavity apex: (I) posterior, (II) central, and (III) anterior. CDR finite element models with and without BII gap were developed based on type II endplate to analyze predictions of relative stress distributions, micromotions and associated risks for subsidence at BII. Results No statistical differences in clinical outcomes and the incidence of implant subsidence or migration between two groups were noted. The proportion of BII gaps after CDR was significantly larger in segments with type I endplate morphology (68.0%) (P = 0.001). The incidence of HO (67.8% vs. 53.5%, P = 0.026), high-grade HO (21.2% vs. 11.4%, P = 0.044), and posterior HO (63.6% vs. 49.1%, P = 0.027) in the gap group was significantly higher. There were obvious stress concentration areas in the posterior region of the endplate in the gap model. The risk for subsidence of the gap model was larger than non-gap model in flexion, extension, and lateral bending. Conclusion The BII gap was common after CDR. The incidences of posterior HO and high-grade HO were higher in the segments with BII gap. Although the BII gap altered the regional biomechanical environment, no effects on the clinical outcomes and risk for implant-related complications were noted.
- 16 April 2025
- Published by Springer Nature in European Spine Journal
- Vol. 34 (6) , 2290-2300
Clinical and biomechanical effects of bone-implant interface gap after cervical disc replacement
Purpose Due to the irregularity of cervical inferior endplate morphology among individuals and segments, a bone-implant interface (BII) gap is usually unavoidable between the prosthesis and endplate after cervical disc replacement (CDR). This study aimed to investigate the clinical and biomechanical effects of the BII gap after CDR. Methods We retrospectively reviewed the clinical and radiological data of 180 patients who underwent 1-level or 2-level CDR. Cervical sagittal parameters, implant subsidence and migration, heterotopic ossification (HO) were evaluated through lateral radiographs. Endplate morphology was classified into three types according to the position of concavity apex: (I) posterior, (II) central, and (III) anterior. CDR finite element models with and without BII gap were developed based on type II endplate to analyze predictions of relative stress distributions, micromotions and associated risks for subsidence at BII. Results No statistical differences in clinical outcomes and the incidence of implant subsidence or migration between two groups were noted. The proportion of BII gaps after CDR was significantly larger in segments with type I endplate morphology (68.0%) (P = 0.001). The incidence of HO (67.8% vs. 53.5%, P = 0.026), high-grade HO (21.2% vs. 11.4%, P = 0.044), and posterior HO (63.6% vs. 49.1%, P = 0.027) in the gap group was significantly higher. There were obvious stress concentration areas in the posterior region of the endplate in the gap model. The risk for subsidence of the gap model was larger than non-gap model in flexion, extension, and lateral bending. Conclusion The BII gap was common after CDR. The incidences of posterior HO and high-grade HO were higher in the segments with BII gap. Although the BII gap altered the regional biomechanical environment, no effects on the clinical outcomes and risk for implant-related complications were noted.
- Open Access
- 6 October 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-9
The effect of the difference in C2–7 angle on the occurrence of dysphagia after anterior cervical discectomy and fusion with the zero-P implant system
Objectives: To investigate the effect of the difference in C2–7 angle on dysphagia after anterior cervical discectomy and fusion (ACDF) with the Zero-P Implant System. Methods: A retrospective analysis of 181 patients who underwent ACDF with the Zero-P Implant System and had at least one year of follow-up from January 2011 to November 2018 was performed. All patients were divided into a non-dysphagia group and a dysphagia group to explore the effect of the difference between postoperative and preoperative C2–7 angle (dC2–7A) on postoperative dysphagia. At the same time, other possible related factors including the difference between postoperative and preoperative O-C2 angle (dO-C2A), sex, age, body mass index (BMI), intraoperative time, estimated blood loss, diabetes mellitus, hypertension, smoking, alcohol consumption, prevertebral soft-tissue swelling (PSTS), the highest segment involved in the surgery and the levels of surgery segments were analyzed. Results: In total, the non-dysphagia group comprised 139 patients and the dysphagia group comprised 42 patients. The single-factor analysis showed that smoking, PSTS and dC2–7A were significantly different between the two groups (P < 0.05). Spearman’s correlation coefficient showed no significant correlation between the degree of dysphagia and dC2–7A (P > 0.05). The results of the multiple-factor analysis with an ordinal logistic regression model showed that smoking, PSTS and dC2–7A were significantly associated with the incidence of dysphagia (P < 0.05). Conclusions: The postoperative C2–7 angle has an important effect on the occurrence of dysphagia in patients undergoing Zero-P implant system interbody fusion surgery.
- 6 October 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-9
Open AccessThe effect of the difference in C2–7 angle on the occurrence of dysphagia after anterior cervical discectomy and fusion with the zero-P implant system
Objectives: To investigate the effect of the difference in C2–7 angle on dysphagia after anterior cervical discectomy and fusion (ACDF) with the Zero-P Implant System. Methods: A retrospective analysis of 181 patients who underwent ACDF with the Zero-P Implant System and had at least one year of follow-up from January 2011 to November 2018 was performed. All patients were divided into a non-dysphagia group and a dysphagia group to explore the effect of the difference between postoperative and preoperative C2–7 angle (dC2–7A) on postoperative dysphagia. At the same time, other possible related factors including the difference between postoperative and preoperative O-C2 angle (dO-C2A), sex, age, body mass index (BMI), intraoperative time, estimated blood loss, diabetes mellitus, hypertension, smoking, alcohol consumption, prevertebral soft-tissue swelling (PSTS), the highest segment involved in the surgery and the levels of surgery segments were analyzed. Results: In total, the non-dysphagia group comprised 139 patients and the dysphagia group comprised 42 patients. The single-factor analysis showed that smoking, PSTS and dC2–7A were significantly different between the two groups (P < 0.05). Spearman’s correlation coefficient showed no significant correlation between the degree of dysphagia and dC2–7A (P > 0.05). The results of the multiple-factor analysis with an ordinal logistic regression model showed that smoking, PSTS and dC2–7A were significantly associated with the incidence of dysphagia (P < 0.05). Conclusions: The postoperative C2–7 angle has an important effect on the occurrence of dysphagia in patients undergoing Zero-P implant system interbody fusion surgery.