Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Minhee Yun has a total of 68 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Rapid ultrasensitive and specific BNP biosensor with LED readout

    by Seth So, Jorge Torres Quiñones, Soonkon Kim, Byoungdeog Choi, Minhee Yun

    Biosensing for diagnostics has risen rapidly in popularity over the past decades. With the discovery of new nanomaterials and morphologies, sensitivity is being constantly improved enough for reliable detection of trace biomarkers in human samples, like serum or sweat. This precision has enabled detailed research on the efficacy of biosensors. However, current biosensors suffer from reduced speed of operation. To make better use of this sensitivity, the development of a conductometric biosensor with in-situ use of an Laser Emitting Device (LED) display can provide rapid determination of sample results, steadily pushing biosensors toward more clinical, point-of-care (POC) applications. In this research, a simple LED was used for facile optical determination and visual output of an ultrasensitive bio-signal amplification circuit was made to interface with a B-type Natriuretic Peptide (BNP) biosensor. Tuning circuit gain enables an elegant method for adjustable separation of concentrations into 3 discrete categories: sub-threshold, analog, and saturation regions. These regions corresponded to 0 < [C] < 500 pg/mL (25, 100, 250 pg/mL, LED off), 500 < [C] < 1000 pg/mL (LED varying intensity), and 1000 pg/mL < [C] (LED full intensity). System efficacy was tested using human blood serum samples from University of Pittsburgh Medical Center patients, which were able to be accurately detected and sorted for rapid low cost and power. determination without need for complex digital elements. Additional specificity testing suggests insignificant impact of non-target biomarkers.

  • Open Access

    Rapid Ultrasensitive and Specific BNP Biosensor with LED Readout

    by Seth So, Jorge Torres Quiñones, Soonkon Kim, Byoungdeog Choi, Minhee Yun

    Biosensing for diagnostics has risen rapidly in popularity over the past decades. With the discovery of new nanomaterials and morphologies, sensitivity is being constantly improved enough for reliable detection of trace biomarkers in human samples, like serum or sweat. This precision has enabled detailed research on the efficacy of biosensors. However, current biosensors suffer from reduced speed of operation. To make better use of this sensitivity, the development of a conductometric biosensor with in-situ use of an LED display can provide rapid determination of sample results, steadily pushing biosensors toward more clinical, point-of-care (POC) applications. In this research, a simple LED (laser emitting diode) was used for facile optical determination and visual output of an ultrasensitive bio-signal amplification circuit was made to interface with a b-type natriuretic peptide (BNP) biosensor. Tuning circuit gain enables an elegant method for adjustable separation of concentrations into 3 discrete categories: sub-threshold, analog, and saturation regions. These regions corresponded to 0 < [C] < 500 pg/mL (LED off), 500 < [C] < 1000 pg/mL (LED varying intensity), and 1000 pg/mL < [C] (LED full intensity). System efficacy was tested using human blood serum samples from University of Pittsburgh Medical Center patients, which were able to be accurately detected and sorted for rapid lo-fi. determination without need for complex digital elements. Additional specificity testing suggests insignificant impact of non-target biomarkers.

  • Optical Duality of Molybdenum Disulfide: Metal and Semiconductor

    by Wonkil Sakong, Hamza Zad Gul, Byungwook Ahn, Suar Oh, Giheon Kim, Eunji Sim, Jaeuk Bahng, Hojoon Yi, Minjeong Kim, Minhee Yun, et al.

    The two different light-matter interactions between visible and infrared light are not switchable because control mechanisms have not been elucidated so far, which restricts the effective spectral range in light-sensing devices. In this study, modulation of the effective spectral range is demonstrated using the metal-insulator transition of MoS2. Nondegenerate MoS2 exhibits a photoconductive effect in detecting visible light. In contrast, degenerate MoS2 responds only to mid-infrared (not visible) light by displaying a photoinduced heating effect via free carrier absorption. Depending on the doping level, the optical behavior of MoS2 simulates the photoconductivity of either the semiconductor or the metal, further indicating that the optical metal-insulator transition is coherent with its electrical counterpart. The electrical switchability of MoS2 enables the development of an unprecedented and novel design optical sensor that can detect both visible and mid-IR (wavelength of 9.6 μm) ranges with a singular optoelectronic device.


  • Asymmetric Bipolar Resistive Switching of Halide Perovskite Film in Contact with TiO2 Layer

    by Seongha Lee, Sarah Wolfe, Jorge Torres, Minhee Yun, Jung-Kun Lee

    Halide perovskite materials such as methylammonium lead iodide (CH3NH3PbI3) have attracted considerable interest for the resistive random-access memory applications, which exploit a dramatic change in the resistance by an external electric bias. In many semiconductor films, the drift, accumulation, and chain formation of defects explain the change in the resistance by an external bias. This study demonstrates that the interface of CH3NH3PbI3 with TiO2 has a significant impact on the formation and rupture of defect chains and causes the asymmetric bipolar resistive switching in the Au/CH3NH3PbI3/TiO2/FTO device (FTO = fluorine-doped tin oxide). When a negative bias is applied to the Au electrode, iodine interstitials with the lowest migration activation energy move toward TiO2 in the CH3NH3PbI3 layer and pile up at the CH3NH3PbI3–TiO2 interface. Under the same condition, oxygen vacancies in the TiO2 layer also travel to the CH3NH3PbI3–TiO2 interface and strongly attract iodine interstitials. As a result, a Schottky barrier appears at the CH3NH3PbI3–TiO2 interface, and the resistance of Au/CH3NH3PbI3/TiO2/FTO becomes much larger than that of Au/CH3NH3PbI3/FTO in the high resistance state. The frequency dependence of the capacitance confirms the asymmetric appearance of a large space charge polarization at the CH3NH3PbI3–TiO2 interface, which causes the unique bipolar resistive switching behavior with the on/off ratio (103) and retention time (>104 seconds) at −0.85 V in Au/CH3NH3PbI3/TiO2/FTO film.


  • Induced bioresistance via BNP detection for machine learning-based risk assessment

    by Seth So, Aya Khalaf, Xinruo Yi, Connor Herring, Yingze Zhang, Marc A. Simon, Murat Akcakaya, SeungHee Lee, Minhee Yun


  • Effects of Surface Modifications to Single and Multilayer Graphene Temperature Coefficient of Resistance

    by Jorge Torres, Yulin Liu, Seth So, Hojoon Yi, Sangho Park, Jung-Kun Lee, Seong Chu Lim, Min Hee Yun

    Interfacial effects on single-layer graphene (SLG) or multilayer graphene (MLG) properties greatly affect device performance. Thus, the effect of the interface on the temperature coefficient of resistance (TCR) on SLG and MLG due to surface deposited core-shell metallic nanoparticles (MNPs) and various substrates was experimentally investigated. Observed substrates included glass, SiO2, and Si3N4. We show that these modifications can be used to strongly influence SLG interface effects, thus increasing TCR up to a 0.456% per K resistance change when in contact with SiO2 substrate at the bottom surface and MNPs on the top surface. However, these surface interactions are muted in MLG due to the screening effect of non-superficial layers, only achieving a -0.0998% per K resistance change in contact with the bottom Si3N4 substrate and the top MNPs. We also demonstrate contrary thermal sensitivity responses between SLG and MLG after the addition of MNP to the surface.


  • Adhesion Energies of 2D Graphene and MoS2 to Silicon and Metal Substrates

    by Jorge Torres, Yisi Zhu, Pei Liu, Seong Chu Lim, Minhee Yun

    In this paper, results for the adhesion energy of graphene and MoS2 to silicon based and metal substrates using the intercalation of nanoparticles method are presented. In this method, nanoparticles are dispersed onto the substrates before transferring the 2D material onto the substrate. This causes a blister to form, the width and height of which can be measured by AFM. Using a simple model then allows for the adhesion energy to be found. The substrates tested are SiO2, Si­3N4, gold, and platinum. Gold is found to have the highest adhesion energy per area of 7687.10 and 1207.26 mJ m−2 for graphene and MoS2 respectively.


  • Two-dimensional polyaniline nanostructure to the development of microfluidic integrated flexible biosensors for biomarker detection

    by Pei Liu, Yisi Zhu, Seung Hee Lee, Minhee Yun

    In this work, we report a flexible field-effect-transistor (FET) biosensor design based on two-dimensional (2-D) polyaniline (PANI) nanostructure. The flexible biosensor devices were fabricated through a facile and inexpensive method that combines top-down and bottom-up processes. The chemically synthesized PANI nanostructure showed excellent p-type semiconductor properties as well as good compatibility with flexible design. With the 2-D PANI nanostructure being as thin as 80 nm and its extremely large surface-area-to-volume (SA/V) ratio due to the intrinsic properties of PANI chemical synthesis, the developed flexible biosensor exhibited outstanding sensing performance in detecting B-type natriuretic peptide (BNP) biomarkers, and was able to achieve high specificity (averagely 112 folds) with the limit of detection as low as 100 pg/mL. PANI nanostructure under bending condition was also investigated and showed controllable conductance changes being less than 20% with good restorability which may open up the possibility for wearable applications.


  • Open Access

    Changes in Carbon Electrode Morphology Affect Microbial Fuel Cell Performance with Shewanella oneidensis MR-1

    by David V. P. Sanchez, Daniel Jacobs, Kelvin Gregory, Jiyong Huang, Yushi Hu, Radisav Vidic, Minhee Yun

    The formation of biofilm-electrodes is crucial for microbial fuel cell current production because optimal performance is often associated with thick biofilms. However, the influence of the electrode structure and morphology on biofilm formation is only beginning to be investigated. This study provides insight on how changing the electrode morphology affects current production of a pure culture of anode-respiring bacteria. Specifically, an analysis of the effects of carbon fiber electrodes with drastically different morphologies on biofilm formation and anode respiration by a pure culture (Shewanella oneidensis MR-1) were examined. Results showed that carbon nanofiber mats had ~10 fold higher current than plain carbon microfiber paper and that the increase was not due to an increase in electrode surface area, conductivity, or the size of the constituent material. Cyclic voltammograms reveal that electron transfer from the carbon nanofiber mats was biofilm-based suggesting that decreasing the diameter of the constituent carbon material from a few microns to a few hundred nanometers is beneficial for electricity production solely because the electrode surface creates a more relevant mesh for biofilm formation by Shewanella oneidensis MR-1.