Libin Zeng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Libin Zeng has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Yao Pan
National University of Defense Technology
10 shared publications - Hui Luo
National University of Defense Technology
7 shared publications - Jingyu Li
National University of Defense Technology
7 shared publications - Xingyuan Tang
National University of Defense Technology
6 shared publications - Pengbo Xiao
College of Advanced Interdisciplinary Studies, National University of Defense Technology, Changsha 410073, China
5 shared publications - Yiming Luo
College of Advanced Interdisciplinary Studies, National University of Defense Technology, Changsha 410073, China
3 shared publications
Latest Publications
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
Identification and Compensation of Detection Electrode Errors in Hemispherical Resonator Gyroscopes via Bidirectional Turntable Rotations
The increasing demand for whole-angle mode operation in hemispherical resonator gyroscopes (HRGs) necessitates the development of precise calibration and compensation methods for angle-dependent bias (ADB) that preserves their long-term stability and high-accuracy properties. Besides the anisoelasticity and anisodamping of the resonator, the interference between control loops induced by electrode errors, including the actuation electrode error (AEE) and the detection electrode error (DEE), has also become one of the major factors that limit the accuracy of rate-integrating gyroscopes (RIGs). In this paper, a novel bi-directional rotations-based method for the DEE identification is proposed, which significantly improves the compensation accuracy compared to existing techniques. An evaluation criterion based on the invariance of the magnitudes and signs of the residual ADB across varying turntable speeds is further proposed. Notably, this study presents the first explicit demonstration that the DEE must be compensated before the AEE to avoid cross-coupled errors and ensure calibration accuracy. Both gap unevenness and angle misalignment are considered in the error model, and they are found to be proportional with the amplitudes of the Cos4θ and Sin4θ components of the DEE-induced additional ADB. After the compensation of the DEE, AEE and anisodamping error, the real-time bias stability (1σ) of a WA mode HRG was improved to 0.0081°/h. Additionally, this identification and compensation method for the DEE can be widely extended to other resonant gyroscopes with annular sensing elements.
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
Identification and Compensation of Detection Electrode Errors in Hemispherical Resonator Gyroscopes via Bidirectional Turntable Rotations
The increasing demand for whole-angle mode operation in hemispherical resonator gyroscopes (HRGs) necessitates the development of precise calibration and compensation methods for angle-dependent bias (ADB) that preserves their long-term stability and high-accuracy properties. Besides the anisoelasticity and anisodamping of the resonator, the interference between control loops induced by electrode errors, including the actuation electrode error (AEE) and the detection electrode error (DEE), has also become one of the major factors that limit the accuracy of rate-integrating gyroscopes (RIGs). In this paper, a novel bi-directional rotations-based method for the DEE identification is proposed, which significantly improves the compensation accuracy compared to existing techniques. An evaluation criterion based on the invariance of the magnitudes and signs of the residual ADB across varying turntable speeds is further proposed. Notably, this study presents the first explicit demonstration that the DEE must be compensated before the AEE to avoid cross-coupled errors and ensure calibration accuracy. Both gap unevenness and angle misalignment are considered in the error model, and they are found to be proportional with the amplitudes of the Cos4θ and Sin4θ components of the DEE-induced additional ADB. After the compensation of the DEE, AEE and anisodamping error, the real-time bias stability (1σ) of a WA mode HRG was improved to 0.0081°/h. Additionally, this identification and compensation method for the DEE can be widely extended to other resonant gyroscopes with annular sensing elements.
- 1 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 46 (11) , 2134-2137
0.08 ppm Scale Factor Nonlinearity in Whole-Angle Hemispherical Resonator Gyroscopes Enabled by Rapid Detection Signal Nonlinearity Suppression
Detection signal nonlinearity, induced by nonlinear capacitive variations in electrode gaps, fundamentally limits the performance of whole-angle (WA) mode hemispherical resonator gyroscopes (HRGs). This letter proposes a rapid identification method for this nonlinearity based on the relationship between the amplitude-gap ratio and resonator vibration energy. Experimental results across 100-500 °/s input rotation velocities confirms method accuracy and operational robustness. Post-compensation HRG achieves a bias instability (BI) of 0.006 °/h and a scale factor nonlinearity (SFN) of 0.08 ppm. The achieved SFN of 0.08 ppm represents the lowest reported value for WA mode HRGs to date.
- 1 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 46 (11) , 2134-2137
0.08 ppm Scale Factor Nonlinearity in Whole-Angle Hemispherical Resonator Gyroscopes Enabled by Rapid Detection Signal Nonlinearity Suppression
Detection signal nonlinearity, induced by nonlinear capacitive variations in electrode gaps, fundamentally limits the performance of whole-angle (WA) mode hemispherical resonator gyroscopes (HRGs). This letter proposes a rapid identification method for this nonlinearity based on the relationship between the amplitude-gap ratio and resonator vibration energy. Experimental results across 100-500 °/s input rotation velocities confirms method accuracy and operational robustness. Post-compensation HRG achieves a bias instability (BI) of 0.006 °/h and a scale factor nonlinearity (SFN) of 0.08 ppm. The achieved SFN of 0.08 ppm represents the lowest reported value for WA mode HRGs to date.
- 1 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (20) , 37732-37741
Dual-Channel Phase Delay Compensation for Hemispherical Resonator Gyroscopes With Angle-Dependent Bias Reduction to 3.190×10-5°/s
This paper presents a high-precision hemispherical resonator gyroscope (HRG) capable of compensating for dual-channel phase delay induced by both control circuit and control circuit asymmetries. Conventional phase delay identification methods, which target aggregate phase delay, fail to resolve phase delay mismatch between two channels, thereby limiting the achievable precision of HRGs. This work contributes dynamic models analyzing dual-channel phase delay effects on control force coupling and angle-dependent bias (ADB). Novel identification method of dual-channel phase delay is proposed leveraging the quadrature control force under controlled standing wave angles and external rotational rates. Compensation efficacy is benchmarked against conventional phase delay identification methods under identical conditions, and results show the superiority of the proposed method with significant performance improvement: after dual-channel phase delay compensation at room temperature, the ADB decreased from 5.130×10-3°/s to 3.190×10-5°/s with a reduction of 99.378 %, while the bias instability (BI) improved from 1.215×10-1°/h to 8.740×10-3°/h with an improvement of 92.805%.
- 1 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (20) , 37732-37741
Dual-Channel Phase Delay Compensation for Hemispherical Resonator Gyroscopes With Angle-Dependent Bias Reduction to 3.190×10-5°/s
This paper presents a high-precision hemispherical resonator gyroscope (HRG) capable of compensating for dual-channel phase delay induced by both control circuit and control circuit asymmetries. Conventional phase delay identification methods, which target aggregate phase delay, fail to resolve phase delay mismatch between two channels, thereby limiting the achievable precision of HRGs. This work contributes dynamic models analyzing dual-channel phase delay effects on control force coupling and angle-dependent bias (ADB). Novel identification method of dual-channel phase delay is proposed leveraging the quadrature control force under controlled standing wave angles and external rotational rates. Compensation efficacy is benchmarked against conventional phase delay identification methods under identical conditions, and results show the superiority of the proposed method with significant performance improvement: after dual-channel phase delay compensation at room temperature, the ADB decreased from 5.130×10-3°/s to 3.190×10-5°/s with a reduction of 99.378 %, while the bias instability (BI) improved from 1.215×10-1°/h to 8.740×10-3°/h with an improvement of 92.805%.
- 14 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (16) , 30524-30535
Temperature-Dependent Bias Drift Compensation Based on a Dual Hemispherical Resonator Gyroscope System
Hemispherical resonator gyroscopes (HRGs) exhibit exceptional force-to-rebalance (FTR) precision but suffer from temperature-dependent drift, limiting widespread deployment. This study presents a temperature-dependent bias drift compensation method for HRGs using a dual-HRG system configuration. The dual-HRG system compensates for temperature-dependent bias drift based on mode reversal. By implementing alternating mode-reversal control sequences between two HRGs, the dual-HRG system overcomes the limitations of single HRG mode reversal in practical applications. Furthermore, based on the calibration results of phase delay errors, electrode errors and scale factors (SFs) at different temperatures, corresponding temperature compensation modules are incorporated into the dual-HRG system. The residual temperature-dependent bias drift is further compensated by applying the multiple regression algorithm. Experimental results demonstrate that the bias stability of the dual-HRG system after mode reversal is improved by more than 98.7% and 87.7% compared to the two individual HRGs, respectively. Moreover, the temperature-dependent bias drift is further compensated by the multiple regression algorithm, and the bias stability of the dual-HRG system is improved by more than 70.5%.
- 14 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (16) , 30524-30535
Temperature-Dependent Bias Drift Compensation Based on a Dual Hemispherical Resonator Gyroscope System
Hemispherical resonator gyroscopes (HRGs) exhibit exceptional force-to-rebalance (FTR) precision but suffer from temperature-dependent drift, limiting widespread deployment. This study presents a temperature-dependent bias drift compensation method for HRGs using a dual-HRG system configuration. The dual-HRG system compensates for temperature-dependent bias drift based on mode reversal. By implementing alternating mode-reversal control sequences between two HRGs, the dual-HRG system overcomes the limitations of single HRG mode reversal in practical applications. Furthermore, based on the calibration results of phase delay errors, electrode errors and scale factors (SFs) at different temperatures, corresponding temperature compensation modules are incorporated into the dual-HRG system. The residual temperature-dependent bias drift is further compensated by applying the multiple regression algorithm. Experimental results demonstrate that the bias stability of the dual-HRG system after mode reversal is improved by more than 98.7% and 87.7% compared to the two individual HRGs, respectively. Moreover, the temperature-dependent bias drift is further compensated by the multiple regression algorithm, and the bias stability of the dual-HRG system is improved by more than 70.5%.
- Open Access
- 9 July 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (7) , 802
Comparative Noise Analysis of Readout Circuit in Hemispherical Resonator Gyroscope
In high-precision Hemispherical Resonator Gyroscope (HRG) control systems, readout circuit noise critically determines resonator displacement detection precision. Addressing noise issues, this paper compares the noise characteristics and contribution mechanisms of the Transimpedance Amplifier (TIA) and Charge-Sensitive Amplifier (CSA). By establishing a noise model and analyzing circuit bandwidth, the dominant role of feedback resistor thermal noise in the TIA is revealed. These analyses further demonstrate the significant suppression of high-frequency noise by the CSA capacitive feedback network. Simulation and experimental results demonstrate that the measured noise of the TIA and CSA is consistent with the theoretical model. The TIA output noise is 25.8 , with feedback resistor thermal noise accounting for 99.8%, while CSA output noise is reduced to 13.2 , a reduction of 48.8%. Near resonant frequency, the equivalent displacement noise of the CSA is , a reduction of 86.7% compared to the TIA’s , indicating the CSA is more suitable for high-precision applications. This research provides theoretical guidance and technical references for the topological selection and parameter design of HRG readout circuits.- 9 July 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (7) , 802
Open AccessComparative Noise Analysis of Readout Circuit in Hemispherical Resonator Gyroscope
In high-precision Hemispherical Resonator Gyroscope (HRG) control systems, readout circuit noise critically determines resonator displacement detection precision. Addressing noise issues, this paper compares the noise characteristics and contribution mechanisms of the Transimpedance Amplifier (TIA) and Charge-Sensitive Amplifier (CSA). By establishing a noise model and analyzing circuit bandwidth, the dominant role of feedback resistor thermal noise in the TIA is revealed. These analyses further demonstrate the significant suppression of high-frequency noise by the CSA capacitive feedback network. Simulation and experimental results demonstrate that the measured noise of the TIA and CSA is consistent with the theoretical model. The TIA output noise is 25.8 , with feedback resistor thermal noise accounting for 99.8%, while CSA output noise is reduced to 13.2 , a reduction of 48.8%. Near resonant frequency, the equivalent displacement noise of the CSA is , a reduction of 86.7% compared to the TIA’s , indicating the CSA is more suitable for high-precision applications. This research provides theoretical guidance and technical references for the topological selection and parameter design of HRG readout circuits. - 23 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (15) , 28101-28109
A Phase Delay Suppression Method With Temperature Robustness for Hemispherical Resonator Gyroscopes Operating in the Force-to-Rebalance Mode
This paper proposes a temperature-robust phase delay suppression method for hemispherical resonator gyroscopes in the force-to-rebalance mode. The phase delay can lead to coupling between the quadrature control loop and the force-to-rebalance control loop, which is a primary cause of the bias drift. Although methods for the phase delay identification and compensation have been reported in literatures, the effect of temperature variation on the phase delay is not considered and the effectiveness of the phase delay compensation relies heavily on the precision of the phase delay identification. In this paper, a method is proposed to suppress the influence of the phase delay by aligning the azimuth of the standing wave with the stiffness axis instead of identifying and compensating the phase delay. Compared to the phase delay compensation method proposed by our group previously, the method presented in this paper further enhanced the performance of the gyroscope operated under the force-to-rebalance mode. Experimental results reveal that, compared to the phase delay compensation method proposed by our group previously, the bias instability of the hemispherical resonator gyroscope is improved from 0.009 °/h to 0.006 °/h, demonstrating an improvement of 33.3%, and the scale factor nonlinearity is improved from 47.4 ppm to 8.6 ppm, demonstrating an improvement of 81.9%. Measurement results of the stiffness axis and scale factor nonlinearity across the temperature range of -10 °C to 60 °C demonstrate the temperature robustness of the proposed method. The method is straightforward to implement and yields significant improvements, providing a new approach to suppress the influence of phase delay on the performance of hemispherical resonator gyroscopes operating in the force-to-rebalance mode.
- 23 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (15) , 28101-28109
A Phase Delay Suppression Method With Temperature Robustness for Hemispherical Resonator Gyroscopes Operating in the Force-to-Rebalance Mode
This paper proposes a temperature-robust phase delay suppression method for hemispherical resonator gyroscopes in the force-to-rebalance mode. The phase delay can lead to coupling between the quadrature control loop and the force-to-rebalance control loop, which is a primary cause of the bias drift. Although methods for the phase delay identification and compensation have been reported in literatures, the effect of temperature variation on the phase delay is not considered and the effectiveness of the phase delay compensation relies heavily on the precision of the phase delay identification. In this paper, a method is proposed to suppress the influence of the phase delay by aligning the azimuth of the standing wave with the stiffness axis instead of identifying and compensating the phase delay. Compared to the phase delay compensation method proposed by our group previously, the method presented in this paper further enhanced the performance of the gyroscope operated under the force-to-rebalance mode. Experimental results reveal that, compared to the phase delay compensation method proposed by our group previously, the bias instability of the hemispherical resonator gyroscope is improved from 0.009 °/h to 0.006 °/h, demonstrating an improvement of 33.3%, and the scale factor nonlinearity is improved from 47.4 ppm to 8.6 ppm, demonstrating an improvement of 81.9%. Measurement results of the stiffness axis and scale factor nonlinearity across the temperature range of -10 °C to 60 °C demonstrate the temperature robustness of the proposed method. The method is straightforward to implement and yields significant improvements, providing a new approach to suppress the influence of phase delay on the performance of hemispherical resonator gyroscopes operating in the force-to-rebalance mode.
- 5 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-15
An Investigation on Influences of the Phase Delay and the Electrode Errors on a Mode-Reversal Hemispherical Resonator Gyroscope
The damping asymmetry, the phase delay and the electrode errors are crucial factors that limit the performance of hemispherical resonator gyroscopes. This paper employs mode reversal to compensate for damping asymmetry. A mathematical model is first established incorporating the stiffness asymmetry, the damping asymmetry, the phase delay and the electrode errors. The influences of the phase delay and the electrode errors on mode-reversal force-to-rebalance hemispherical resonator gyroscopes are analyzed, respectively. New methods to identify the phase delay and the electrode errors are proposed, which eliminate the influences of both the control-loop couplings and the couplings among different error sources. Experimental results demonstrate that the angle-dependent bias in the turntable-rotation mode is reduced from 3.72 °/s to 0.02 °/s after the compensation of detection electrode errors, demonstrating a decrease of 99.5%; the angle-dependent bias in the virtual-rotation mode is reduced from 0.107 °/s to 0.006 °/s after the compensation of actuation electrode errors, demonstrating a decrease of 94.4%. After compensation, the bias instability of the mode-reversal force-to-rebalance hemispherical resonator gyroscope is improved from 0.046 °/h to 0.003 °/h, demonstrating an improvement of 93.5%. The proposed methods can be widely applied to Coriolis vibratory gyroscopes with symmetric structures operating in both the force-to-rebalance mode and the whole-angle mode.
- 5 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-15
An Investigation on Influences of the Phase Delay and the Electrode Errors on a Mode-Reversal Hemispherical Resonator Gyroscope
The damping asymmetry, the phase delay and the electrode errors are crucial factors that limit the performance of hemispherical resonator gyroscopes. This paper employs mode reversal to compensate for damping asymmetry. A mathematical model is first established incorporating the stiffness asymmetry, the damping asymmetry, the phase delay and the electrode errors. The influences of the phase delay and the electrode errors on mode-reversal force-to-rebalance hemispherical resonator gyroscopes are analyzed, respectively. New methods to identify the phase delay and the electrode errors are proposed, which eliminate the influences of both the control-loop couplings and the couplings among different error sources. Experimental results demonstrate that the angle-dependent bias in the turntable-rotation mode is reduced from 3.72 °/s to 0.02 °/s after the compensation of detection electrode errors, demonstrating a decrease of 99.5%; the angle-dependent bias in the virtual-rotation mode is reduced from 0.107 °/s to 0.006 °/s after the compensation of actuation electrode errors, demonstrating a decrease of 94.4%. After compensation, the bias instability of the mode-reversal force-to-rebalance hemispherical resonator gyroscope is improved from 0.046 °/h to 0.003 °/h, demonstrating an improvement of 93.5%. The proposed methods can be widely applied to Coriolis vibratory gyroscopes with symmetric structures operating in both the force-to-rebalance mode and the whole-angle mode.
- Open Access
- 15 May 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 135 (19)
Frequency mismatch analysis of hemispherical shell resonators with both radius and thickness imperfections
The hemispherical shell resonator (HSR) is the core element of the hemispherical resonator gyroscope (HRG), and its frequency mismatch is a key property influencing gyroscope accuracy. Investigating the mechanism of frequency mismatch is vital for improving the quality of HSRs and performance of HRGs. Midsurface radius imperfections and thickness imperfections are two principal causes of frequency mismatch, but their combined effects have rarely been discussed. This paper develops a model to comprehensively analyze the frequency mismatch of HSRs with both radius and thickness imperfections. The model derives a quantitative relation between the frequency mismatch and the two imperfections, and provides principles for evaluating dominant imperfections. To validate the model, we conduct experiments on a batch of 12 HSRs with random geometric imperfections. We apply the model in calculating the theoretical frequency mismatches of these HSRs, and the results agree well with the experimental data. The experiment also confirms that for macro-HSRs, thickness imperfections have a larger impact than radius imperfections, and the frequency mismatch is approximately linear to the fourth thickness harmonic. Our research can be a useful reference for the design and fabrication of HSRs and may open new possibilities for high-precision manufacture of HRGs.
- 15 May 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 135 (19)
Open AccessFrequency mismatch analysis of hemispherical shell resonators with both radius and thickness imperfections
The hemispherical shell resonator (HSR) is the core element of the hemispherical resonator gyroscope (HRG), and its frequency mismatch is a key property influencing gyroscope accuracy. Investigating the mechanism of frequency mismatch is vital for improving the quality of HSRs and performance of HRGs. Midsurface radius imperfections and thickness imperfections are two principal causes of frequency mismatch, but their combined effects have rarely been discussed. This paper develops a model to comprehensively analyze the frequency mismatch of HSRs with both radius and thickness imperfections. The model derives a quantitative relation between the frequency mismatch and the two imperfections, and provides principles for evaluating dominant imperfections. To validate the model, we conduct experiments on a batch of 12 HSRs with random geometric imperfections. We apply the model in calculating the theoretical frequency mismatches of these HSRs, and the results agree well with the experimental data. The experiment also confirms that for macro-HSRs, thickness imperfections have a larger impact than radius imperfections, and the frequency mismatch is approximately linear to the fourth thickness harmonic. Our research can be a useful reference for the design and fabrication of HSRs and may open new possibilities for high-precision manufacture of HRGs.
- Open Access
- 17 September 2021
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 54 (49) , 495104
Fused silica cylindrical shell resonators with 25 million Q factors
The Q factors of fused silica cylindrical shell resonators reaching 25 million is reported. The finite element method is employed to analyze the anchor loss and chemical etching is used to reduce the surface loss of cylindrical resonators. Two resonators with the same processing parameters are etched for 13 rounds with each round set as 5 min. After each round of chemical etching, the surface roughness, Q factors and resonant frequencies of the two resonators are measured. The Q factors of the two cylindrical resonators have both exceeded 25 million, reaching the level of that of fused silica hemispherical resonators. Results also indicate that the Q factors of fused silica cylindrical resonators are not related with their surface roughness. This study shows the potential of the cylindrical resonator gyroscope to achieve the same degree of precision as the hemispherical resonator gyroscope, which has presented outstanding performances.
- 17 September 2021
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 54 (49) , 495104
Open AccessFused silica cylindrical shell resonators with 25 million Q factors
The Q factors of fused silica cylindrical shell resonators reaching 25 million is reported. The finite element method is employed to analyze the anchor loss and chemical etching is used to reduce the surface loss of cylindrical resonators. Two resonators with the same processing parameters are etched for 13 rounds with each round set as 5 min. After each round of chemical etching, the surface roughness, Q factors and resonant frequencies of the two resonators are measured. The Q factors of the two cylindrical resonators have both exceeded 25 million, reaching the level of that of fused silica hemispherical resonators. Results also indicate that the Q factors of fused silica cylindrical resonators are not related with their surface roughness. This study shows the potential of the cylindrical resonator gyroscope to achieve the same degree of precision as the hemispherical resonator gyroscope, which has presented outstanding performances.
- Open Access
- 30 August 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (9) , 1052
Experimental Study on Variation of Surface Roughness and Q Factors of Fused Silica Cylindrical Resonators with Different Grinding Speeds
For the axisymmetric shell resonator gyroscopes, the quality factor (Q factor) of the resonator is one of the core parameters limiting their performances. Surface loss is one of the dominating losses, which is related to the subsurface damage (SSD) that is influenced by the grinding parameters. This paper experimentally studies the surface roughness and Q factor variation of six resonators ground by three different grinding speeds. The results suggest that the removal of the SSD cannot improve the Q factor continuously, and the variation of surface roughness is not the dominant reason to affect the Q factor. The measurement results indicate that an appropriate increase in the grinding speed can significantly improve the surface quality and Q factor. This study also demonstrates that a 20 million Q factor for fused silica cylindrical resonators is achievable using appropriate manufacturing processes combined with post-processing etching, which offers possibilities for developing high-precision and low-cost cylindrical resonator gyroscopes.
- 30 August 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (9) , 1052
Open AccessExperimental Study on Variation of Surface Roughness and Q Factors of Fused Silica Cylindrical Resonators with Different Grinding Speeds
For the axisymmetric shell resonator gyroscopes, the quality factor (Q factor) of the resonator is one of the core parameters limiting their performances. Surface loss is one of the dominating losses, which is related to the subsurface damage (SSD) that is influenced by the grinding parameters. This paper experimentally studies the surface roughness and Q factor variation of six resonators ground by three different grinding speeds. The results suggest that the removal of the SSD cannot improve the Q factor continuously, and the variation of surface roughness is not the dominant reason to affect the Q factor. The measurement results indicate that an appropriate increase in the grinding speed can significantly improve the surface quality and Q factor. This study also demonstrates that a 20 million Q factor for fused silica cylindrical resonators is achievable using appropriate manufacturing processes combined with post-processing etching, which offers possibilities for developing high-precision and low-cost cylindrical resonator gyroscopes.