Claudia Venditti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Claudia Venditti has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Alessandra Adrover
Dipartimento di Ingegneria Chimica Materiali Ambiente, Sapienza Università di Roma, Italy
18 shared publications - Gert Desmet
Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, 1050 Brussel, Belgium
6 shared publications - Massimiliano Giona
Sapienza Università di Roma
5 shared publications Massimiliano Giona
3 shared publicationsAlessandra Adrover
Department of Chemical Engineering, Materials, Environment, Sapienza Università di Roma, Via Eudossiana 18, 00184 Rome, Italy
2 shared publications- Ali Moussa
Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium
2 shared publications
Latest Publications
- Open Access
- 9 September 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1787
Wall-induced dispersion in multicapillary columns with diffusional bridging
- 9 September 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1787
Open AccessWall-induced dispersion in multicapillary columns with diffusional bridging
- Open Access
- 17 July 2026
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 27 (14) , 6355
Pilot Study on the Use of Low-Field Nuclear Magnetic Resonance as a Noninvasive Tool for Monitoring Mucus in Obstructive Lung Diseases
Patients with muco-obstructive lung disease (MOLD) exhibit chronic bronchitis and inflammation, along with a progressive decline in lung function. Lung monitoring is typically performed using spirometry, especially by measuring the forced expired volume in the first second (FEV1). However, the limitations of spirometry motivated the exploration of alternative approaches. The spin–spin relaxation time (T2m) and the spin–lattice relaxation time (T1m) of sputum water hydrogens were measured using low-field nuclear magnetic resonance (LF-NMR) in 38 MOLD patients and 16 controls. The levels of TNFα/IL-6, the sputum microbiome composition/amount/indices and FEV1 were determined in parallel. We also investigated the correlation between T2m/T1m and the disease index (ID); ID, calculated relying on patient FEV1/TNFα/IL-6/bacteria concentration Cb values, is a measure of the patient’s distance from the average healthy control. We observed the following significant correlations: T2m/T1m with ID, T2m with Cb, a potential correlation of T2m with the bacteria genera Streptococcus and Staphylococcus, T2m with the Shannon index, which reflects the broadness of the bacterial community in the sputum, and T2m with TNFα. FEV1 did not show any correlation. Our noninvasive/radiation-free/portable method of T2m/T1m measurement shows potential value in monitoring lung conditions in MOLD patients and may contribute to improved clinical decision-making.
- 17 July 2026
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 27 (14) , 6355
Open AccessPilot Study on the Use of Low-Field Nuclear Magnetic Resonance as a Noninvasive Tool for Monitoring Mucus in Obstructive Lung Diseases
Patients with muco-obstructive lung disease (MOLD) exhibit chronic bronchitis and inflammation, along with a progressive decline in lung function. Lung monitoring is typically performed using spirometry, especially by measuring the forced expired volume in the first second (FEV1). However, the limitations of spirometry motivated the exploration of alternative approaches. The spin–spin relaxation time (T2m) and the spin–lattice relaxation time (T1m) of sputum water hydrogens were measured using low-field nuclear magnetic resonance (LF-NMR) in 38 MOLD patients and 16 controls. The levels of TNFα/IL-6, the sputum microbiome composition/amount/indices and FEV1 were determined in parallel. We also investigated the correlation between T2m/T1m and the disease index (ID); ID, calculated relying on patient FEV1/TNFα/IL-6/bacteria concentration Cb values, is a measure of the patient’s distance from the average healthy control. We observed the following significant correlations: T2m/T1m with ID, T2m with Cb, a potential correlation of T2m with the bacteria genera Streptococcus and Staphylococcus, T2m with the Shannon index, which reflects the broadness of the bacterial community in the sputum, and T2m with TNFα. FEV1 did not show any correlation. Our noninvasive/radiation-free/portable method of T2m/T1m measurement shows potential value in monitoring lung conditions in MOLD patients and may contribute to improved clinical decision-making.
- Open Access
- 17 January 2025
- Published by Elsevier in Journal of Chromatography A
- Vol. 1743, 465676
Dispersion properties of triply periodic minimal surface stationary phases for LC: The case of superficial adsorption
- 17 January 2025
- Published by Elsevier in Journal of Chromatography A
- Vol. 1743, 465676
Open AccessDispersion properties of triply periodic minimal surface stationary phases for LC: The case of superficial adsorption
- 11 May 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (21) , 8747-8753
An In-Depth Investigation of Micropillar Array Columns for the Separation of Finite-Sized Particles by Hydrodynamic Chromatography
The exact moment approach (EMA) is adopted to predict, without any fitting parameters, the plate height curves for polystyrene microparticles of different sizes in micropillar array columns performed by hydrodynamic chromatography. The EMA allows us to decouple the contribution of horizontal and vertical dispersion terms and thus investigate the influence of pillar height and interpillar distance on separation performance. In the convection-controlled regime, we found that axial dispersion is mainly controlled by the vertical dispersion term, the latter being due to the flow-arresting top and bottom walls. This vertical contribution can be estimated from the axial dispersion in rectangular, open tubular channels formed between the pillars. Henceforth, plate height curves can be accurately predicted by simply adding the estimated vertical term to the horizontal dispersion term evaluated from 2D simulations. This finding allowed us to understand that, to improve separation performance, it is advisible to decrease the interpillar distance (expected result) and decrease the pillar height (counterintuitive result).
- 11 May 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (21) , 8747-8753
An In-Depth Investigation of Micropillar Array Columns for the Separation of Finite-Sized Particles by Hydrodynamic Chromatography
The exact moment approach (EMA) is adopted to predict, without any fitting parameters, the plate height curves for polystyrene microparticles of different sizes in micropillar array columns performed by hydrodynamic chromatography. The EMA allows us to decouple the contribution of horizontal and vertical dispersion terms and thus investigate the influence of pillar height and interpillar distance on separation performance. In the convection-controlled regime, we found that axial dispersion is mainly controlled by the vertical dispersion term, the latter being due to the flow-arresting top and bottom walls. This vertical contribution can be estimated from the axial dispersion in rectangular, open tubular channels formed between the pillars. Henceforth, plate height curves can be accurately predicted by simply adding the estimated vertical term to the horizontal dispersion term evaluated from 2D simulations. This finding allowed us to understand that, to improve separation performance, it is advisible to decrease the interpillar distance (expected result) and decrease the pillar height (counterintuitive result).
- 19 March 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1720, 464825
On the contribution of the top and bottom walls in micro-pillar array columns and related high-aspect ratio chromatography systems
- 19 March 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1720, 464825
On the contribution of the top and bottom walls in micro-pillar array columns and related high-aspect ratio chromatography systems
- Open Access
- 18 March 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1721, 464817
On the modelling of the effective longitudinal diffusion in bi-continuous chromatographic beds
- 18 March 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1721, 464817
Open AccessOn the modelling of the effective longitudinal diffusion in bi-continuous chromatographic beds
- Open Access
- 6 January 2024
- Published by MDPI AG in Separations
- Vol. 11 (1) , 22
Prediction of Plate Height Curves of Porous-Shell Pillar Array Columns Micro-Pillar Array Columns
We investigate band broadening in the most widely adopted configuration of micro-pillar array columns (PACs)—specifically, a cylindrical pillar array where both the pillar walls and the channel bottom are coated with a thin layer of mesoporous material. The two-zone moment analysis method is adopted to investigate the dispersion properties of PACs in a broad range of shell thicknesses, reduced fluid velocities, and retention factors. Three different models of the unit cell, of increasing complexity, have been implemented, namely a two-dimensional model and two different three-dimensional models with and without the retentive bottom layer, the presence of which seems to have a very significant effect on the plate height curves. Model predictions are compared with experimental van Deemter curves for uncoated and coated porous layers, and a robust relationship between the intra-particle (porous-zone) diffusion coefficient and the retention factor is established.- 6 January 2024
- Published by MDPI AG in Separations
- Vol. 11 (1) , 22
Open AccessPrediction of Plate Height Curves of Porous-Shell Pillar Array Columns Micro-Pillar Array Columns
We investigate band broadening in the most widely adopted configuration of micro-pillar array columns (PACs)—specifically, a cylindrical pillar array where both the pillar walls and the channel bottom are coated with a thin layer of mesoporous material. The two-zone moment analysis method is adopted to investigate the dispersion properties of PACs in a broad range of shell thicknesses, reduced fluid velocities, and retention factors. Three different models of the unit cell, of increasing complexity, have been implemented, namely a two-dimensional model and two different three-dimensional models with and without the retentive bottom layer, the presence of which seems to have a very significant effect on the plate height curves. Model predictions are compared with experimental van Deemter curves for uncoated and coated porous layers, and a robust relationship between the intra-particle (porous-zone) diffusion coefficient and the retention factor is established. - Open Access
- 27 December 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1715, 464598
An alternative general model for the effective longitudinal diffusion in chromatographic beds filled with ordered porous particles
- 27 December 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1715, 464598
Open AccessAn alternative general model for the effective longitudinal diffusion in chromatographic beds filled with ordered porous particles
- 4 October 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (41) , 15199-15207
Nonadditivity and Nonlinearity of Mobile and Stationary Zone Mass Transfer Resistances in Chromatography
Using a two-zone moment analysis (TZMA) method based on Brenner's generalized dispersion theory for two-dimensional (2D) and three-dimensional (3D) periodic media, we investigated the mechanisms for dispersion in particulate media for liquid chromatography. This was done using a set of plate height data covering an unprecedented wide range of retention factors, diffusion coefficients, and velocities, all computed with unequaled accuracy. Applying Giddings' additivity test, based on alternatingly making the diffusion coefficient in the mobile and stationary zones infinitely large, the dispersion data clearly indicate a lack of additivity. Although this lack could be directly understood by identifying the existence of multiple parallel mass transfer paths, the additivity assumption interestingly overestimates the true C term band broadening (typically by more than 10%, depending on conditions and dimensionality of the system). However, Giddings originally asserted the occurrence of parallel paths would always lead to an underestimation of the dispersion. The origin of the lack of additivity is analyzed in detail and qualitatively explained. Finally, we also established a generic framework for the modeling of the effect of the reduced velocity and the retention coefficient on the C term in ordered chromatographic media. This led to the introduction of a new expression for the mobile zone mass transfer term, which, unlike the currently used literature expression, contains the complete k″ dependency.
- 4 October 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (41) , 15199-15207
Nonadditivity and Nonlinearity of Mobile and Stationary Zone Mass Transfer Resistances in Chromatography
Using a two-zone moment analysis (TZMA) method based on Brenner's generalized dispersion theory for two-dimensional (2D) and three-dimensional (3D) periodic media, we investigated the mechanisms for dispersion in particulate media for liquid chromatography. This was done using a set of plate height data covering an unprecedented wide range of retention factors, diffusion coefficients, and velocities, all computed with unequaled accuracy. Applying Giddings' additivity test, based on alternatingly making the diffusion coefficient in the mobile and stationary zones infinitely large, the dispersion data clearly indicate a lack of additivity. Although this lack could be directly understood by identifying the existence of multiple parallel mass transfer paths, the additivity assumption interestingly overestimates the true C term band broadening (typically by more than 10%, depending on conditions and dimensionality of the system). However, Giddings originally asserted the occurrence of parallel paths would always lead to an underestimation of the dispersion. The origin of the lack of additivity is analyzed in detail and qualitatively explained. Finally, we also established a generic framework for the modeling of the effect of the reduced velocity and the retention coefficient on the C term in ordered chromatographic media. This led to the introduction of a new expression for the mobile zone mass transfer term, which, unlike the currently used literature expression, contains the complete k″ dependency.
- 1 December 2022
- Published by AIP Publishing in Physics of Fluids
- Vol. 34 (12) , 122013
Exact moment analysis of transient/asymptotic dispersion properties in periodic media with adsorbing/desorbing walls
The paper develops a robust and computationally efficient homogenization approach, grounded on exact local and integral moments, to investigate the temporal evolution of effective dispersion properties of solute particles in periodic media possessing absorbing/desorbing walls. Adsorption onto and desorption from active walls allow linear and reversible mass transfer between the solid surface and the fluid phase. The transient analysis reveals some important features of the dispersion process that cannot be captured by asymptotic approaches aimed at determining exclusively the long-range/large-distance dispersion properties. Two case studies are considered: the dispersion of an analyte in a sinusoidal channel with adsorbing/desorbing walls and the retentive pillar array column for liquid chromatography. For both systems, the transient analysis shows how the tortuous fluid motion induced by the sinusoidal walls or by the presence of pillars induces wide and persistent temporal oscillations of the effective velocity and dispersion coefficient even for a steady (non-pulsating) Stokes flow. The adsorption/desorption process strongly amplifies the phenomenon of the overshoot for the effective dispersion coefficient that, on short/intermediate time scales, reaches values significantly larger than the asymptotic one. Moreover, the method proposed allows a detailed analysis of the temporal evolution of the skewness of the marginal distribution of the analyte along the main stream direction. It clearly shows that the time scale for achieving the macro-transport regime, which implies a Gaussian (symmetric) marginal pdf, is largely underestimated if one bases the analysis on the attainment of constant asymptotic values for the effective velocity and for the dispersion coefficient.
- 1 December 2022
- Published by AIP Publishing in Physics of Fluids
- Vol. 34 (12) , 122013
Exact moment analysis of transient/asymptotic dispersion properties in periodic media with adsorbing/desorbing walls
The paper develops a robust and computationally efficient homogenization approach, grounded on exact local and integral moments, to investigate the temporal evolution of effective dispersion properties of solute particles in periodic media possessing absorbing/desorbing walls. Adsorption onto and desorption from active walls allow linear and reversible mass transfer between the solid surface and the fluid phase. The transient analysis reveals some important features of the dispersion process that cannot be captured by asymptotic approaches aimed at determining exclusively the long-range/large-distance dispersion properties. Two case studies are considered: the dispersion of an analyte in a sinusoidal channel with adsorbing/desorbing walls and the retentive pillar array column for liquid chromatography. For both systems, the transient analysis shows how the tortuous fluid motion induced by the sinusoidal walls or by the presence of pillars induces wide and persistent temporal oscillations of the effective velocity and dispersion coefficient even for a steady (non-pulsating) Stokes flow. The adsorption/desorption process strongly amplifies the phenomenon of the overshoot for the effective dispersion coefficient that, on short/intermediate time scales, reaches values significantly larger than the asymptotic one. Moreover, the method proposed allows a detailed analysis of the temporal evolution of the skewness of the marginal distribution of the analyte along the main stream direction. It clearly shows that the time scale for achieving the macro-transport regime, which implies a Gaussian (symmetric) marginal pdf, is largely underestimated if one bases the analysis on the attainment of constant asymptotic values for the effective velocity and for the dispersion coefficient.