Zhenlu Shao

Zhenlu Shao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zhenlu Shao has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    3D Inversion of Underground Concealed Coal Fire Sources Based on Self-Potential Data in Xinjiang, China

    by Long Chen, Xiaoxing Zhong, Zhenlu Shao, Tao Zhou, Guofu Zhang, Fei Cao, Zichao Jia

    Accurate localization of concealed fire sources is the fundamental prerequisite for effective coal fire control and mitigation. The self-potential method, as a passive, cost-effective geophysical technique for large-area surveys, exhibits unique advantages in coal fire detection, yet 3D inversion of self-potential data for high-precision coal fire source localization remains insufficiently studied. In this paper, a 3D iterative compact inversion algorithm based on the minimum support functional is adopted to invert self-potential data for 3D localization of underground concealed coal fire sources. The algorithm’s reliability and robustness are verified systematically via numerical simulations at both laboratory and field scales, followed by sandbox experiments with artificial battery sources and burning coal specimens, and finally validated its engineering applicability in the Sandaoba Coal Fire Area in Xinjiang. Numerical results show that the algorithm achieves high-precision inversion of source current density across multiple orders of magnitude, with a relative error below 10%. Sandbox experiments confirm that coal combustion generates a typical dipole self-potential field with distinct negative surface anomalies, whose amplitude is positively correlated with combustion intensity. Field inversion results successfully delineate the 3D boundary of the concealed fire source (buried at 40–140 m), which is highly consistent with borehole temperature measurement data. This study provides a robust technical framework for 3D detection of concealed coal fires, offering strong technical support for precise coal fire governance and hazard mitigation.

  • Open Access

    Monitoring Burning Coal Gangue Dump Based on the 3-D Thermal Infrared Model

    by Zhenlu Shao, Tong Yang, Rong Deng, Hongwen Shao

    Coal gangue is the byproduct of coal mining and preparation. Due to its susceptibility to spontaneous combustion, it causes significant environmental hazards when piled up in open dumps. The fire not only harms the environment but also poses health risks to nearby residents. Therefore, accurately identifying the location and extent of the coal gangue dump fire is crucial for effective fire suppression. However, the clarity and precision of detection face challenges. This article proposes a novel technique that utilizes thermal infrared oblique photography captured by unmanned aerial vehicle to create three-dimensional (3-D) surface temperature field models of fire areas. In addition, batch preprocessing software is designed to standardize the temperature threshold and color distribution across each thermal infrared image, and the effects of different temperature thresholds are investigated. The article focuses on the spontaneous combustion area of the south coal gangue dump at the Antaibao open-pit mine in Shanxi Province. The findings demonstrate the rapid and precise reconstruction of the 3-D temperature field in the fire area, the elimination of pseudo-high-temperature areas, and the accurate identification of the fire within the coal gangue dump. This method facilitates effective fire suppression and controls measures for the burning coal gangue dump, reducing the associated risks.


  • Locating the Scope and Depth of Coal Fires Based on Magnetic and Electrical Data

    by Zhenlu Shao, Guofu Zhang, Tao Zhou, Jun Wei, Fei Cao, Yong Zhang, Hongsheng Li, Huahai Sun, Shangkun Qing, Teng Chen, et al.


  • Open Access

    Fire detection methods based on an optimized YOLOv5 algorithm

    by Zhenlu Shao, Siyu Lu, Xunxian Shi, Dezhi Yang, Zhaolong Wang

    Computer vision technology has broad application prospects in the field of intelligent fire detection, which has the benefits of accuracy, timeliness, visibility, adjustability, and multi-scene adaptability. Traditional computer vision algorithm flaws include erroneous detection, detection gaps, poor precision, and slow detection speed. In this paper, the efficient and lightweight YOLOv5s model is used to detect the fire flame and smoke. The attention mechanism is embedded into the C3 module to enhance the backbone network and maximize the algorithm's suppression of invalid feature data. Alpha CIOU is adopted to improve the positioning function and detection target. At the same time, the concept of transfer learning is used to realize semi-automatic data annotation, which reduces training expenses in terms of manpower and time. The comparative experiments of 6 distinct fire detection algorithms (YOLOv5 and 5 optimization algorithms) are carried out. The results indicate that the self-attention mechanism based on the Transformer structure has a substantial impact on enhancing target detection precision. The improved location function based on Alpha CIOU aids in enhancing the detection recall rate. The average recall rate of fire detection of the YOlOv5+TR+αCIOU algorithm is the highest, which is 68.5%, clearly outperforming other algorithms. Based on the surveillance video, this optimization algorithm is utilized to detect a fire in a factory, and the fire is detected in the 9th second when it starts to appear. The results demonstrate the algorithm's viability for real-time fire detection.


  • Constructing 3-D Land Surface Temperature Model of Local Coal Fires Using UAV Thermal Images

    by Zhenlu Shao, Yuntao Liang, Fuchao Tian, Shuanglin Song, Rong Deng

    Coal fires have led to severe ecological disasters worldwide and threatened the health and safety of nearby residents to a certain extent. It is critical to detect the scope and extent of coal fires in order to control and extinguish them. In this article, the unmanned aerial vehicle (UAV), thermal infrared imaging, and oblique photogrammetry technologies were integrated to create a 3-D land surface temperature model of the Chunjingwa Coal Fire in Shanxi Province, China. Hundreds of visible and thermal infrared images were collected from five flight survey lines. The thermal infrared images were preprocessed in batches to meet the requirements of 3-D modeling. The construction of the thermal infrared 3-D model of the fires was achieved successfully, allowing for the visualization of the surface temperature field in true 3-D. Four high-temperature zones were delineated according to the 3-D land surface temperature model. Furthermore, the features of ground objects were clearly depicted by the visible 3-D model constructed by visible images, and the digital elevation model (DEM) was established based on the spatial coordinate contained in the visible 3-D model. The research results provide technical support for the subsequent firefighting plan and a reference for the high-precision detection of other coal fires around the world.


  • Open Access

    Recapitulation and Prospect of Research on Flow Field in Coal Mine Gob

    by Rui Zhang, Jianwei Cheng, Zui Wang, Zhenlu Shao

    Coal mine gob, mined‐out areas in underground coal mines, often accumulates explosive methane‐air mixtures that pose a deadly hazard to miners. A good understanding of the flow field in a sealed coal mine area is crucial in preventing and minimizing accidents associated with mine combustible gases and also for planning and implementing a mine rescue strategy. In recent years, the research on the flow field in the gob has changed from qualitative research in the past to quantitative research. This paper synthesizes the research results of flow field in gob in recent 40 years, covering the permeability of quarried areas, the airflow simulation in quarried areas, and the influence of ventilation parameters and geohydrological conditions on the flow field. Firstly, the overburden failure mechanism and fracture development characteristics of the mine gob, the distribution of porosity and permeability in the gob, and the relationship between them are introduced. Secondly, the development of research methods and numerical models used to study the flow field in mine gob is discussed. The distribution of the flow field in the gob under different conditions is expounded. Thirdly, the research on the prevention and control of fire and explosion risks in the gob is discussed. Finally, the problems to be solved in such research direction are addressed and suggestions are put forward.


  • Treatment of smouldering coal refuse piles: an application in China

    by Zhenlu Shao, Deming Wang, Kai Cao, Weibin Si, Yizhou Li, Jiaolong Liu

    Coal refuse pile fires are a serious health, safety, and environment hazard. The fires in Guoshan Coal Refuse Pile affect daily life of the local residents. Although conventional fire control methods (water injection, grouting and surface sealing) were used to control the fires, they rekindled soon after the fire-fighting engineering was quitted. Thus, effective methods need to be applied to extinguish the fires completely without reignition. In this paper, the environmental impact of the fire on the local land, water and air is illustrated by sample analysis and photos. The self-potential method, which achieves remote detection from the ground surface, is adopted to delineate the scope of the fires to give support for the efficient and economical extinguishment of them. The three-phase foam containing water, gas and loess is proposed to control and extinguish the fires. The corresponding fire-fighting system is also invented to fit the field work and put out the fires more efficiently and conveniently. The temperature monitoring result shows that the fires are extinguished successfully with no sign of reignition.