Jan Sijbrands
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jan Sijbrands has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Arlene L. Oei
Department of Radiation Oncology, Amsterdam UMC, Amsterdam, The Netherlands
2 shared publications - Hans M. Rodermond
Laboratory for Experimental Oncology and Radiobiology (LEXOR), Center for Experimental Molecular Medicine, Amsterdam University Medical Centers, P.O. Box 22700, 1100 DE Amsterdam, The Netherlands
2 shared publications - Hp Kok
Amsterdam University Medical Center, University of Amsterdam, Department of Radiation Oncology, Cancer Center Amsterdam, Amsterdam, The Netherlands
2 shared publications - Johannes Crezee
Department of Radiation Oncology, Amsterdam UMC, University of Amsterdam, Cancer Center Amsterdam, 1105 AZ Amsterdam, The Netherlands
2 shared publications - Nicolaas A. P. Franken
Laboratory for Experimental Oncology and Radiobiology (LEXOR), Center for Experimental Molecular Medicine, Amsterdam University Medical Centers, P.O. Box 22700, 1100 DE Amsterdam, The Netherlands
2 shared publications - Daan R. Löke
Department of Radiation Oncology, Cancer Center Amsterdam, Amsterdam University Medical Centers (UMC), University of Amsterdam, Amsterdam, Netherlands
1 shared publication
Latest Publications
- Open Access
A Four-Inflow Construction to Ensure Thermal Stability and Uniformity during Hyperthermic Intraperitoneal Chemotherapy (HIPEC) in Rats
Background: Hyperthermic intraperitoneal chemotherapy (HIPEC) after cytoreductive surgery (CRS) is used for treating peritoneal metastases of various origins. Present HIPEC protocols have rarely been validated for relevant parameters such as optimal agent, duration and perfusate temperature. In vitro experiments are not completely representative of clinical circumstances. Therefore, a good preclinical in vivo HIPEC model is needed in which temperature distributions can be well-controlled and are stable throughout treatments. Methods: We designed a setup able to generate and maintain a homogeneous flow during a 90-min HIPEC procedure using our in-house developed treatment planning tools and computer aided design (CAD) techniques. Twelve rats were treated with heated phosphate-buffered saline (PBS) using two catheter setups (one vs. four- inflows) and extensive thermometry. Simulated and measured thermal distribution and core temperatures were evaluated for the different setups. Results: Overall, the four-inflow resulted in more stable and more homogeneous thermal distributions than the one-inflow, with lower standard deviations (0.79 °C vs. 1.41 °C at the outflow, respectively) and less thermal losses. The average thermal loss was 0.4 °C lower for rats treated with the four-inflow setup. Rat core temperatures were kept stable using occasional tail cooling, and rarely exceeded 39 °C. Conclusion: Increasing the number of inflow catheters from one to four resulted in increased flow and temperature homogeneity and stability. Tail cooling is an adequate technique to prevent rats from overheating during 90-min treatments. This validated design can improve accuracy in future in vivo experiments investigating the impact of relevant parameters on the efficacy of different HIPEC protocols.
Open AccessA Four-Inflow Construction to Ensure Thermal Stability and Uniformity during Hyperthermic Intraperitoneal Chemotherapy (HIPEC) in Rats
Background: Hyperthermic intraperitoneal chemotherapy (HIPEC) after cytoreductive surgery (CRS) is used for treating peritoneal metastases of various origins. Present HIPEC protocols have rarely been validated for relevant parameters such as optimal agent, duration and perfusate temperature. In vitro experiments are not completely representative of clinical circumstances. Therefore, a good preclinical in vivo HIPEC model is needed in which temperature distributions can be well-controlled and are stable throughout treatments. Methods: We designed a setup able to generate and maintain a homogeneous flow during a 90-min HIPEC procedure using our in-house developed treatment planning tools and computer aided design (CAD) techniques. Twelve rats were treated with heated phosphate-buffered saline (PBS) using two catheter setups (one vs. four- inflows) and extensive thermometry. Simulated and measured thermal distribution and core temperatures were evaluated for the different setups. Results: Overall, the four-inflow resulted in more stable and more homogeneous thermal distributions than the one-inflow, with lower standard deviations (0.79 °C vs. 1.41 °C at the outflow, respectively) and less thermal losses. The average thermal loss was 0.4 °C lower for rats treated with the four-inflow setup. Rat core temperatures were kept stable using occasional tail cooling, and rarely exceeded 39 °C. Conclusion: Increasing the number of inflow catheters from one to four resulted in increased flow and temperature homogeneity and stability. Tail cooling is an adequate technique to prevent rats from overheating during 90-min treatments. This validated design can improve accuracy in future in vivo experiments investigating the impact of relevant parameters on the efficacy of different HIPEC protocols.
- Open Access
HyCHEED System for Maintaining Stable Temperature Control during Preclinical Irreversible Electroporation Experiments at Clinically Relevant Temperature and Pulse Settings
Electric permeabilization of cell membranes is the main mechanism of irreversible electroporation (IRE), an ablation technique for treatment of unresectable cancers, but the pulses also induce a significant temperature increase in the treated volume. To investigate the therapeutically thermal contribution, a preclinical setup is required to apply IRE at desired temperatures while maintaining stable temperatures. This study’s aim was to develop and test an electroporation device capable of maintaining a pre-specified stable and spatially homogeneous temperatures and electric field in a tumor cell suspension for several clinical-IRE-settings. A hydraulically controllable heat exchange electroporation device (HyCHEED) was developed and validated at 37 °C and 46 °C. Through plate electrodes, HyCHEED achieved both a homogeneous electric field and homogenous-stable temperatures; IRE heat was removed through hydraulic cooling. IRE was applied to 300 μL of pancreatic carcinoma cell suspension (Mia PaCa-2), after which cell viability and specific conductivity were determined. HyCHEED maintained stable temperatures within ±1.5 °C with respect to the target temperature for multiple IRE-settings at the selected temperature levels. An increase of cell death and specific conductivity, including post-treatment, was found to depend on electric-field strength and temperature. HyCHEED is capable of maintaining stable temperatures during IRE-experiments. This provides an excellent basis to assess the contribution of thermal effects to IRE and other bio-electromagnetic techniques.
Open AccessHyCHEED System for Maintaining Stable Temperature Control during Preclinical Irreversible Electroporation Experiments at Clinically Relevant Temperature and Pulse Settings
Electric permeabilization of cell membranes is the main mechanism of irreversible electroporation (IRE), an ablation technique for treatment of unresectable cancers, but the pulses also induce a significant temperature increase in the treated volume. To investigate the therapeutically thermal contribution, a preclinical setup is required to apply IRE at desired temperatures while maintaining stable temperatures. This study’s aim was to develop and test an electroporation device capable of maintaining a pre-specified stable and spatially homogeneous temperatures and electric field in a tumor cell suspension for several clinical-IRE-settings. A hydraulically controllable heat exchange electroporation device (HyCHEED) was developed and validated at 37 °C and 46 °C. Through plate electrodes, HyCHEED achieved both a homogeneous electric field and homogenous-stable temperatures; IRE heat was removed through hydraulic cooling. IRE was applied to 300 μL of pancreatic carcinoma cell suspension (Mia PaCa-2), after which cell viability and specific conductivity were determined. HyCHEED maintained stable temperatures within ±1.5 °C with respect to the target temperature for multiple IRE-settings at the selected temperature levels. An increase of cell death and specific conductivity, including post-treatment, was found to depend on electric-field strength and temperature. HyCHEED is capable of maintaining stable temperatures during IRE-experiments. This provides an excellent basis to assess the contribution of thermal effects to IRE and other bio-electromagnetic techniques.