Jiyoung Hwang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jiyoung Hwang has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Seong Sook Hong
Department of Radiology, Soonchunhyang University Seoul Hospital, Seoul, Korea
17 shared publications - Eun Ji Lee
Department of Radiology, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul, Korea
14 shared publications - Yun-Woo Chang
Department of Radiology, Soonchunhyang University Seoul Hospital, Seoul, Korea
13 shared publications - Hyun-Joo Kim
Department of Radiology, Soonchunhyang University Seoul Hospital, Seoul, Korea
8 shared publications Seong Sook Hong
Department of Radiology, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul, Korea
7 shared publications- Bo Da Nam
Department of Radiology, Soonchunhyang University Seoul Hospital, Soonchunhyang University School of Medicine, Seoul 04401, Republic of Korea
5 shared publications
Latest Publications
- Open Access
- 1 March 2025
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 44 (2) , 160-169
Novel non-invasive and quantitative assessment of the renal function of transplanted kidneys using Doppler ultrasonography with the vascular index of superb microvascular imaging
Purpose: This study assessed the reproducibility and clinical value of the vascular index (VI), derived from superb microvascular imaging (SMI) using Doppler ultrasonography, for evaluating renal function in transplanted kidneys.Methods: This retrospective study included 63 renal transplant patients who underwent grayscale and Doppler ultrasonography with SMI from January 2022 to February 2023. The VI of the transplanted kidneys was measured using three methods (VIbox, VIF1, VIF2). The VI was compared across chronic kidney disease (CKD) groups categorized by estimated glomerular filtration rate (eGFR) and Kidney Disease: Improving Global Outcomes (KDIGO) CKD risk groups based on eGFR and albuminuria. The correlation between VI and renal function was evaluated. Univariate and multivariate linear regression analyses were used to identify predictors of eGFR.Results: Significant differences in VI were observed among CKD groups based on eGFR (VIbox, P=0.001; VIF1, P<0.001; VIF2, P<0.001) and KDIGO CKD groups based on eGFR and albuminuria (VIbox, P=0.039; VIF1, P=0.001; VIF2, P<0.001). VIF1 and VIF2 demonstrated moderate/high correlations with eGFR (r=0.627, P<0.001 and r=0.657, P<0.001, respectively) and serum creatinine (r=-0.626, P<0.001 and r=-0.649, P<0.001, respectively). VIbox moderately correlated with eGFR (r=0.445, P<0.001). Multivariate regression identified the urine albumincreatinine ratio (ACR) (adjusted odds ratio [aOR], 1.122; 95% confidence interval [CI], -0.007 to, 0.000; P=0.030) and VIF2 (aOR, 1.114; 95% CI, 0.466 to 1.235; P<0.001) were independently associated with eGFR.Conclusion: The VI measured by drawing a region of interest along the border of the transplanted kidney in SMI (VIF2) is highly reproducible and correlates well with eGFR. Both VIF2 and ACR independently predict eGFR.
- 1 March 2025
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 44 (2) , 160-169
Open AccessNovel non-invasive and quantitative assessment of the renal function of transplanted kidneys using Doppler ultrasonography with the vascular index of superb microvascular imaging
Purpose: This study assessed the reproducibility and clinical value of the vascular index (VI), derived from superb microvascular imaging (SMI) using Doppler ultrasonography, for evaluating renal function in transplanted kidneys.Methods: This retrospective study included 63 renal transplant patients who underwent grayscale and Doppler ultrasonography with SMI from January 2022 to February 2023. The VI of the transplanted kidneys was measured using three methods (VIbox, VIF1, VIF2). The VI was compared across chronic kidney disease (CKD) groups categorized by estimated glomerular filtration rate (eGFR) and Kidney Disease: Improving Global Outcomes (KDIGO) CKD risk groups based on eGFR and albuminuria. The correlation between VI and renal function was evaluated. Univariate and multivariate linear regression analyses were used to identify predictors of eGFR.Results: Significant differences in VI were observed among CKD groups based on eGFR (VIbox, P=0.001; VIF1, P<0.001; VIF2, P<0.001) and KDIGO CKD groups based on eGFR and albuminuria (VIbox, P=0.039; VIF1, P=0.001; VIF2, P<0.001). VIF1 and VIF2 demonstrated moderate/high correlations with eGFR (r=0.627, P<0.001 and r=0.657, P<0.001, respectively) and serum creatinine (r=-0.626, P<0.001 and r=-0.649, P<0.001, respectively). VIbox moderately correlated with eGFR (r=0.445, P<0.001). Multivariate regression identified the urine albumincreatinine ratio (ACR) (adjusted odds ratio [aOR], 1.122; 95% confidence interval [CI], -0.007 to, 0.000; P=0.030) and VIF2 (aOR, 1.114; 95% CI, 0.466 to 1.235; P<0.001) were independently associated with eGFR.Conclusion: The VI measured by drawing a region of interest along the border of the transplanted kidney in SMI (VIF2) is highly reproducible and correlates well with eGFR. Both VIF2 and ACR independently predict eGFR.
- Open Access
- 1 January 2025
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 86 (5) , 720-745
Comprehensive Review of Endometriosis Based on Imaging Findings: What Radiologists Need to Know
김현정, et al. J Korean Soc Radiol. 2025 Sep;86(5):720-745. https://doi.org/10.3348/jksr.2024.0104
- 1 January 2025
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 86 (5) , 720-745
Open AccessComprehensive Review of Endometriosis Based on Imaging Findings: What Radiologists Need to Know
김현정, et al. J Korean Soc Radiol. 2025 Sep;86(5):720-745. https://doi.org/10.3348/jksr.2024.0104
- Open Access
- 1 January 2025
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 86 (3) , 407-412
Transperineal US-Guided Biopsy in Metastatic Prostate Cancer with Low Prostate Specific Antigen: A Case Report
정성은, et al. J Korean Soc Radiol. 2025 May;86(3):407-412. https://doi.org/10.3348/jksr.2024.0006
- 1 January 2025
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 86 (3) , 407-412
Open AccessTransperineal US-Guided Biopsy in Metastatic Prostate Cancer with Low Prostate Specific Antigen: A Case Report
정성은, et al. J Korean Soc Radiol. 2025 May;86(3):407-412. https://doi.org/10.3348/jksr.2024.0006
- Open Access
- 1 January 2025
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 86 (1) , 129-140
Anatomical Variations, Genitourinary Anomalies and Clinical Presentations in Obstructed Hemivagina and Ipsilateral Renal Anomaly Syndrome: Case Series
김현정, et al. J Korean Soc Radiol. 2025 Jan;86(1):129-140. https://doi.org/10.3348/jksr.2024.0018
- 1 January 2025
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 86 (1) , 129-140
Open AccessAnatomical Variations, Genitourinary Anomalies and Clinical Presentations in Obstructed Hemivagina and Ipsilateral Renal Anomaly Syndrome: Case Series
김현정, et al. J Korean Soc Radiol. 2025 Jan;86(1):129-140. https://doi.org/10.3348/jksr.2024.0018
- Open Access
- 1 July 2024
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 43 (4) , 229-237
Transperineal versus transrectal prostate fiducial insertion in radiation treatment of prostate cancer: a systematic review and meta-analysis
Purpose: To provide more accurate and definitive conclusions regarding the clinical and technical complications associated with the transperineal (TP) and transrectal (TR) approaches, a comprehensive review of observational studies and randomized controlled trials was conducted. This systematic review covered all eligible studies to facilitate a thorough comparison of complications linked to the two fiducial marker insertion methods, TP and TR.Methods: A comprehensive search of the literature was conducted, encompassing databases such as PubMed, Embase, and the Cochrane Library, up to July 7, 2023. The relative risk and 95% confidence interval were utilized to evaluate the diagnosis and complication rates.Results: The final selection for the methodological quality analysis included 13 observational studies that utilized TP and TR gold fiducial insertion approaches. The meta-analysis revealed significantly lower risks of urinary tract infections (UTI) and rectal bleeding with the TP approach.Conclusion: The use of both TP and TR techniques for placing gold seed fiducial markers has proven to be an effective, safe, and well-tolerated method for image-guided radiation therapy in prostate cancer patients. A significant benefit of the TP technique is its ability to avoid rectal puncture, thereby reducing the risk of UTIs. Although the incidence of UTIs and rectal bleeding associated with the TR method is relatively low, these complications can disrupt patient wellbeing and potentially cause delays in treatment.
- 1 July 2024
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 43 (4) , 229-237
Open AccessTransperineal versus transrectal prostate fiducial insertion in radiation treatment of prostate cancer: a systematic review and meta-analysis
Purpose: To provide more accurate and definitive conclusions regarding the clinical and technical complications associated with the transperineal (TP) and transrectal (TR) approaches, a comprehensive review of observational studies and randomized controlled trials was conducted. This systematic review covered all eligible studies to facilitate a thorough comparison of complications linked to the two fiducial marker insertion methods, TP and TR.Methods: A comprehensive search of the literature was conducted, encompassing databases such as PubMed, Embase, and the Cochrane Library, up to July 7, 2023. The relative risk and 95% confidence interval were utilized to evaluate the diagnosis and complication rates.Results: The final selection for the methodological quality analysis included 13 observational studies that utilized TP and TR gold fiducial insertion approaches. The meta-analysis revealed significantly lower risks of urinary tract infections (UTI) and rectal bleeding with the TP approach.Conclusion: The use of both TP and TR techniques for placing gold seed fiducial markers has proven to be an effective, safe, and well-tolerated method for image-guided radiation therapy in prostate cancer patients. A significant benefit of the TP technique is its ability to avoid rectal puncture, thereby reducing the risk of UTIs. Although the incidence of UTIs and rectal bleeding associated with the TR method is relatively low, these complications can disrupt patient wellbeing and potentially cause delays in treatment.
- Open Access
- 1 January 2024
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 85 (3) , 654-660
Imaging and Clinical Findings of Primary Malignant Fibrous Histiocytoma of the Urinary Bladder: A Case Report
이윤정, et al. J Korean Soc Radiol. 2024 Jan;85:e17. https://doi.org/10.3348/jksr.2023.0083
- 1 January 2024
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 85 (3) , 654-660
Open AccessImaging and Clinical Findings of Primary Malignant Fibrous Histiocytoma of the Urinary Bladder: A Case Report
이윤정, et al. J Korean Soc Radiol. 2024 Jan;85:e17. https://doi.org/10.3348/jksr.2023.0083
- 14 June 2023
- Published by Springer Nature in European Radiology
- Vol. 33 (11) , 7697-7706
Utility of accelerated T2-weighted turbo spin-echo imaging with deep learning reconstruction in female pelvic MRI: a multi-reader study
Objectives To determine the clinical feasibility of T2-weighted turbo spin-echo (T2-TSE) imaging with deep learning reconstruction (DLR) in female pelvic MRI compared with conventional T2 TSE in terms of image quality and scan time. Methods Between May 2021 and September 2021, 52 women (mean age, 44 years ± 12) who underwent 3-T pelvic MRI with additional T2-TSE using a DLR algorithm were included in this single-center prospective study with patient’s informed consents. Conventional, DLR, and DLR T2-TSE images with reduced scan times were independently assessed and compared by four radiologists. The overall image quality, differentiation of anatomic details, lesion conspicuity, and artifacts were evaluated using a 5-point scale. Inter-observer agreement of the qualitative scores was compared and reader protocol preferences were then evaluated. Results In the qualitative analysis of all readers, fast DLR T2-TSE showed significantly better overall image quality, differentiation of anatomic regions, lesion conspicuity, and lesser artifacts than conventional T2-TSE and DLR T2-TSE, despite approximately 50% reduction in scan time (all p < 0.05). The inter-reader agreement for the qualitative analysis was moderate to good. All readers preferred DLR over conventional T2-TSE regardless of scan time and preferred fast DLR T2-TSE (57.7–78.8%), except for one who preferred DLR over fast DLR T2-TSE (53.8% vs. 46.1%). Conclusion In female pelvic MRI, image quality and accelerated image acquisition for T2-TSE can be significantly improved by using DLR compared to conventional T2-TSE. Fast DLR T2-TSE was non-inferior to DLR T2-TSE in terms of reader preference and image quality. Clinical relevance statement DLR of T2-TSE in female pelvic MRI enables fast imaging along with maintaining optimal image quality compared with parallel imaging-based conventional T2-TSE. Key Points • Conventional T2 turbo spin-echo based on parallel imaging has limitations for accelerated image acquisition while maintaining good image quality. • Deep learning image reconstruction showed better image quality in both images obtained using the same or accelerated image acquisition parameters compared with conventional T2 turbo spin-echo in female pelvic MRI. • Deep learning image reconstruction enables accelerated image acquisition while maintaining good image quality in the T2-TSE of female pelvic MRI.
- 14 June 2023
- Published by Springer Nature in European Radiology
- Vol. 33 (11) , 7697-7706
Utility of accelerated T2-weighted turbo spin-echo imaging with deep learning reconstruction in female pelvic MRI: a multi-reader study
Objectives To determine the clinical feasibility of T2-weighted turbo spin-echo (T2-TSE) imaging with deep learning reconstruction (DLR) in female pelvic MRI compared with conventional T2 TSE in terms of image quality and scan time. Methods Between May 2021 and September 2021, 52 women (mean age, 44 years ± 12) who underwent 3-T pelvic MRI with additional T2-TSE using a DLR algorithm were included in this single-center prospective study with patient’s informed consents. Conventional, DLR, and DLR T2-TSE images with reduced scan times were independently assessed and compared by four radiologists. The overall image quality, differentiation of anatomic details, lesion conspicuity, and artifacts were evaluated using a 5-point scale. Inter-observer agreement of the qualitative scores was compared and reader protocol preferences were then evaluated. Results In the qualitative analysis of all readers, fast DLR T2-TSE showed significantly better overall image quality, differentiation of anatomic regions, lesion conspicuity, and lesser artifacts than conventional T2-TSE and DLR T2-TSE, despite approximately 50% reduction in scan time (all p < 0.05). The inter-reader agreement for the qualitative analysis was moderate to good. All readers preferred DLR over conventional T2-TSE regardless of scan time and preferred fast DLR T2-TSE (57.7–78.8%), except for one who preferred DLR over fast DLR T2-TSE (53.8% vs. 46.1%). Conclusion In female pelvic MRI, image quality and accelerated image acquisition for T2-TSE can be significantly improved by using DLR compared to conventional T2-TSE. Fast DLR T2-TSE was non-inferior to DLR T2-TSE in terms of reader preference and image quality. Clinical relevance statement DLR of T2-TSE in female pelvic MRI enables fast imaging along with maintaining optimal image quality compared with parallel imaging-based conventional T2-TSE. Key Points • Conventional T2 turbo spin-echo based on parallel imaging has limitations for accelerated image acquisition while maintaining good image quality. • Deep learning image reconstruction showed better image quality in both images obtained using the same or accelerated image acquisition parameters compared with conventional T2 turbo spin-echo in female pelvic MRI. • Deep learning image reconstruction enables accelerated image acquisition while maintaining good image quality in the T2-TSE of female pelvic MRI.
- Open Access
- 1 January 2023
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 84 (1) , 127-149
Radiologic Evaluation of Uterine Lesions Using a Pattern Recognition Approach
이나영, et al. J Korean Soc Radiol. 2023 Jan;84:e3. https://doi.org/10.3348/jksr.2022.0009
- 1 January 2023
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 84 (1) , 127-149
Open AccessRadiologic Evaluation of Uterine Lesions Using a Pattern Recognition Approach
이나영, et al. J Korean Soc Radiol. 2023 Jan;84:e3. https://doi.org/10.3348/jksr.2022.0009
- 1 August 2022
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 18 (9) , 1000-1002
Acute Ectopic Pancreatitis Mimicking Peptic Ulcer Disease: A Case Report
Background: Ectopic pancreas is an anatomically separate pancreatic tissue from normal glands with its own vascular and ductal system and most commonly occurs in the upper gastrointestinal tract. Ectopic pancreas is usually asymptomatic, but it can present with symptoms associated with complications, including bleeding, inflammation, and neoplasm without abnormalities in the normal pancreas. Case Presentation: We report a 31-year-old female with acute ectopic pancreatitis involving gastric antrum and proximal duodenum mimicking peptic ulcer disease, without pancreatitis in the normal pancreas. Conclusion: Ectopic pancreatitis is a rare condition and can mimic more common diseases depending on the anatomical location.
- 1 August 2022
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 18 (9) , 1000-1002
Acute Ectopic Pancreatitis Mimicking Peptic Ulcer Disease: A Case Report
Background: Ectopic pancreas is an anatomically separate pancreatic tissue from normal glands with its own vascular and ductal system and most commonly occurs in the upper gastrointestinal tract. Ectopic pancreas is usually asymptomatic, but it can present with symptoms associated with complications, including bleeding, inflammation, and neoplasm without abnormalities in the normal pancreas. Case Presentation: We report a 31-year-old female with acute ectopic pancreatitis involving gastric antrum and proximal duodenum mimicking peptic ulcer disease, without pancreatitis in the normal pancreas. Conclusion: Ectopic pancreatitis is a rare condition and can mimic more common diseases depending on the anatomical location.