Zoltán Csernátony
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zoltán Csernátony has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Sándor Manó
Department of Orthopaedic Surgery, University of Debrecen, Debrecen, Hungary
7 shared publications - Loránd Csámer
Laboratory of Biomechanics, Department of Orthopaedics and Traumatology, Faculty of Medicine, University of Debrecen, H-4032 Debrecen, Hungary
4 shared publications - Dániel Szabó
Department of Orthopaedics and Traumatology, Faculty of Medicine, University of Debrecen, H-4032 Debrecen, Hungary
2 shared publications - Hajnalka Soósné Horváth
Department of Orthopaedic Surgery, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
2 shared publications - Lei Zhang
Laboratory of Biomechanics, Department of Orthopaedic Surgery, Faculty of Medicine, University of Debrecen, H-4032 Debrecen, Hungary
2 shared publications - Viktor Zsolt Kovari
Department of Neurosurgery, Hungarian Defense Forces Medical Centre, 44. Robert Karoly krt., Budapest, 1134, Hungary.
2 shared publications
Latest Publications
- Open Access
- 18 September 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (9) , 1095
Acetabular Revision with McMinn Cup: Development and Application of a Patient-Specific Targeting Device
Background: Surgeries of severe periacetabular bone defects (Paprosky ≥ 2B) are a major challenge in current practice. Although solutions are available for this serious clinical problem, they all have their disadvantages as well as their advantages. An alternative method of reconstructing such extensive defects was the use of a cup with a stem to solve these revision situations. As the instrumentation offered is typically designed for scenarios where a significant bone defect is not present, our unique technique has been developed for implantation in cases where reference points are missing. Our hypothesis was that a targeting device designed based on the CT scan of a patient’s pelvis could facilitate the safe insertion of the guiding wire. Methods: Briefly, our surgical solution consists of a two-step operation. If periacetabular bone loss was found to be more significant during revision surgery, all implants were removed, and two titanium marker screws in the anterior iliac crest were percutaneously inserted. Next, by applying the metal artifact removal (MAR) algorithm, a CT scan of the pelvis was performed. Based on that, the dimensions and positioning of the cup to be inserted were determined, and a patient-specific 3D printed targeting device made of biocompatible material was created to safely insert the guidewire, which is essential to the implantation process. Results: In this study, medical, engineering, and technical tasks related to the design, the surgical technique, and experiences from 17 surgical cases between February 2018 and July 2021 are reported. There were no surgical complications in any cases. The implant had to be removed due to septic reasons (independently from the technique) in a single case, consistent with the septic statistics for this type of surgery. There was not any perforation of the linea terminalis of the pelvis due to the guiding method. The wound healing of patients was uneventful, and the implant was fixed securely. Following rehabilitation, the joints were able to bear weight again. After one to four years of follow-up, the patient satisfaction level was high, and the gait function of the patients improved a lot in all cases. Conclusions: Our results show that CT-based virtual surgical planning and, based on it, the use of a patient-specific 3D printed aiming device is a reliable method for major hip surgeries with significant bone loss. This technique has also made it possible to perform these operations with minimal X-ray exposure.
- 18 September 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (9) , 1095
Open AccessAcetabular Revision with McMinn Cup: Development and Application of a Patient-Specific Targeting Device
Background: Surgeries of severe periacetabular bone defects (Paprosky ≥ 2B) are a major challenge in current practice. Although solutions are available for this serious clinical problem, they all have their disadvantages as well as their advantages. An alternative method of reconstructing such extensive defects was the use of a cup with a stem to solve these revision situations. As the instrumentation offered is typically designed for scenarios where a significant bone defect is not present, our unique technique has been developed for implantation in cases where reference points are missing. Our hypothesis was that a targeting device designed based on the CT scan of a patient’s pelvis could facilitate the safe insertion of the guiding wire. Methods: Briefly, our surgical solution consists of a two-step operation. If periacetabular bone loss was found to be more significant during revision surgery, all implants were removed, and two titanium marker screws in the anterior iliac crest were percutaneously inserted. Next, by applying the metal artifact removal (MAR) algorithm, a CT scan of the pelvis was performed. Based on that, the dimensions and positioning of the cup to be inserted were determined, and a patient-specific 3D printed targeting device made of biocompatible material was created to safely insert the guidewire, which is essential to the implantation process. Results: In this study, medical, engineering, and technical tasks related to the design, the surgical technique, and experiences from 17 surgical cases between February 2018 and July 2021 are reported. There were no surgical complications in any cases. The implant had to be removed due to septic reasons (independently from the technique) in a single case, consistent with the septic statistics for this type of surgery. There was not any perforation of the linea terminalis of the pelvis due to the guiding method. The wound healing of patients was uneventful, and the implant was fixed securely. Following rehabilitation, the joints were able to bear weight again. After one to four years of follow-up, the patient satisfaction level was high, and the gait function of the patients improved a lot in all cases. Conclusions: Our results show that CT-based virtual surgical planning and, based on it, the use of a patient-specific 3D printed aiming device is a reliable method for major hip surgeries with significant bone loss. This technique has also made it possible to perform these operations with minimal X-ray exposure.
- Open Access
- 25 July 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-15
Custom-made 3D printing-based cranioplasty using a silicone mould and PMMA
All types of cranioplasty techniques restore the morphology of the skull and affect patient aesthetics. Safe and easy techniques are required to enhance patients’ recovery and the rehabilitation process. We propose a new method of cranioplasty. The 3-dimensional (3D) reconstruction of a thin-layer computed tomography (CT) scan of the skull was used to reflect the intact side onto the defect and subtract the overlapping points from one another. In this way, a 3D model of the planned implant can be built in the required shape and size. The precise fit of the implant can be checked by printing the defective part of the skull in case it can be modified. A sterilisable silicone mould based on the finalized model was created afterwards. Polymethyl methacrylate implants were prepared directly in an aseptic environment in the operating room during surgery. Between 2005 and 2020, we performed 54 cranioplasties on 52 patients whose craniotomies were performed previously for indications of traumatic brain injury, stroke or tumour surgeries. No technical problems were noted during the operations. In 2 cases, septic complications that occurred were not connected to the technique itself, and the implants were removed and later replaced. Our proposed technique based on 3D-printed individual silicone moulds is a reliable, safe, easily reproducible and low-cost method to repair different skull defects.
- 25 July 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-15
Open AccessCustom-made 3D printing-based cranioplasty using a silicone mould and PMMA
All types of cranioplasty techniques restore the morphology of the skull and affect patient aesthetics. Safe and easy techniques are required to enhance patients’ recovery and the rehabilitation process. We propose a new method of cranioplasty. The 3-dimensional (3D) reconstruction of a thin-layer computed tomography (CT) scan of the skull was used to reflect the intact side onto the defect and subtract the overlapping points from one another. In this way, a 3D model of the planned implant can be built in the required shape and size. The precise fit of the implant can be checked by printing the defective part of the skull in case it can be modified. A sterilisable silicone mould based on the finalized model was created afterwards. Polymethyl methacrylate implants were prepared directly in an aseptic environment in the operating room during surgery. Between 2005 and 2020, we performed 54 cranioplasties on 52 patients whose craniotomies were performed previously for indications of traumatic brain injury, stroke or tumour surgeries. No technical problems were noted during the operations. In 2 cases, septic complications that occurred were not connected to the technique itself, and the implants were removed and later replaced. Our proposed technique based on 3D-printed individual silicone moulds is a reliable, safe, easily reproducible and low-cost method to repair different skull defects.
- Open Access
Comparative Analysis of Bone Ingrowth in 3D-Printed Titanium Lattice Structures with Different Patterns
In this study, metal 3D printing technology was used to create lattice-shaped test specimens of orthopedic implants to determine the effect of different lattice shapes on bone ingrowth. Six different lattice shapes were used: gyroid, cube, cylinder, tetrahedron, double pyramid, and Voronoi. The lattice-structured implants were produced from Ti6Al4V alloy using direct metal laser sintering 3D printing technology with an EOS M290 printer. The implants were implanted into the femoral condyles of sheep, and the animals were euthanized 8 and 12 weeks after surgery. To determine the degree of bone ingrowth for different lattice-shaped implants, mechanical, histological, and image processing tests on ground samples and optical microscopic images were performed. In the mechanical test, the force required to compress the different lattice-shaped implants and the force required for a solid implant were compared, and significant differences were found in several instances. Statistically evaluating the results of our image processing algorithm, it was found that the digitally segmented areas clearly consisted of ingrown bone tissue; this finding is also supported by the results of classical histological processing. Our main goal was realized, so the bone ingrowth efficiencies of the six lattice shapes were ranked. It was found that the gyroid, double pyramid, and cube-shaped lattice implants had the highest degree of bone tissue growth per unit time. This ranking of the three lattice shapes remained the same at both 8 and 12 weeks after euthanasia. In accordance with the study, as a side project, a new image processing algorithm was developed that proved suitable for determining the degree of bone ingrowth in lattice implants from optical microscopic images. Along with the cube lattice shape, whose high bone ingrowth values have been previously reported in many studies, it was found that the gyroid and double pyramid lattice shapes produced similarly good results.
Open AccessComparative Analysis of Bone Ingrowth in 3D-Printed Titanium Lattice Structures with Different Patterns
In this study, metal 3D printing technology was used to create lattice-shaped test specimens of orthopedic implants to determine the effect of different lattice shapes on bone ingrowth. Six different lattice shapes were used: gyroid, cube, cylinder, tetrahedron, double pyramid, and Voronoi. The lattice-structured implants were produced from Ti6Al4V alloy using direct metal laser sintering 3D printing technology with an EOS M290 printer. The implants were implanted into the femoral condyles of sheep, and the animals were euthanized 8 and 12 weeks after surgery. To determine the degree of bone ingrowth for different lattice-shaped implants, mechanical, histological, and image processing tests on ground samples and optical microscopic images were performed. In the mechanical test, the force required to compress the different lattice-shaped implants and the force required for a solid implant were compared, and significant differences were found in several instances. Statistically evaluating the results of our image processing algorithm, it was found that the digitally segmented areas clearly consisted of ingrown bone tissue; this finding is also supported by the results of classical histological processing. Our main goal was realized, so the bone ingrowth efficiencies of the six lattice shapes were ranked. It was found that the gyroid, double pyramid, and cube-shaped lattice implants had the highest degree of bone tissue growth per unit time. This ranking of the three lattice shapes remained the same at both 8 and 12 weeks after euthanasia. In accordance with the study, as a side project, a new image processing algorithm was developed that proved suitable for determining the degree of bone ingrowth in lattice implants from optical microscopic images. Along with the cube lattice shape, whose high bone ingrowth values have been previously reported in many studies, it was found that the gyroid and double pyramid lattice shapes produced similarly good results.
- Open Access
- 25 March 2022
- Published by Joint Diseases and Related Surgery in Joint Diseases and Related Surgery
- Vol. 33 (1) , 9-16
The roof step cut: A novel technique for bony reconstruction of acetabular roof deficiency during total hip replacement
Joint Diseases and Related Surgery (JDRS), the official journal of the Turkish Joint Diseases Foundation, is an international, peer-reviewed, immediate open access journal. All published articles in JDRS has been free for everyone, without embargo, since 1990.
- 25 March 2022
- Published by Joint Diseases and Related Surgery in Joint Diseases and Related Surgery
- Vol. 33 (1) , 9-16
Open AccessThe roof step cut: A novel technique for bony reconstruction of acetabular roof deficiency during total hip replacement
Joint Diseases and Related Surgery (JDRS), the official journal of the Turkish Joint Diseases Foundation, is an international, peer-reviewed, immediate open access journal. All published articles in JDRS has been free for everyone, without embargo, since 1990.
- Open Access
- 9 December 2021
- Published by MDPI AG in Antibiotics
- Vol. 10 (12) , 1509
The Effect of Pharmacist-Led Intervention on Surgical Antibacterial Prophylaxis (SAP) at an Orthopedic Unit
Perioperative antibiotic use is a common reason for antibiotic misuse. Evidence suggests that adherence to SAP guidelines may improve outcomes. The purpose of this study was to analyze the impact of pharmacist-led antibiotic stewardship interventions on SAP guideline compliance. The study was conducted at an Orthopedic Department of a tertiary care medical center. SAP compliance and antibiotic exposure in the pre-intervention and intervention period was compared using chi-square, Fisher exact, and Mann-Whitney tests, as appropriate. Prophylactic antibiotic use in orthopedic joint arthroplasties (overall guideline adherence: agent, dose, frequency, duration), clinical outcomes (length of stay-LOS, number of surgical site infections-SSIs), antibiotic exposure and direct antibiotic costs were compared between pre-intervention and intervention periods. Significant improvement in mean SAP duration (by 42.9%, 4.08 ± 2.08 vs. 2.08 ± 1.90 days, p ˂ 0.001), and overall guideline adherence regarding antibiotic use (by 56.2%, from 2% to 58.2%, p ˂ 0.001) were observed. A significant decrease was observed in antibiotic exposure in SAP (by 41%, from 6.07 ± 0.05 to 3.58 ± 4.33 DDD/patient, p ˂ 0.001), average prophylactic antibiotic cost (by 54.8%, 9278.79 ± 6094.29 vs. 3598.16 ± 3354.55 HUF/patient), and mean LOS (by 37.2%, from 11.22 ± 6.96 to 7.62 ± 3.02 days, p < 0.001); and a slight decrease in the number of confirmed SSIs was found between the two periods (by 1.8%, from 3% to 1.2%, p = 0.21). Continuous presence of the clinical pharmacist led to significant improvement in SAP guideline adherence, which was accompanied by decreased antibiotic exposure and cost.
- 9 December 2021
- Published by MDPI AG in Antibiotics
- Vol. 10 (12) , 1509
Open AccessThe Effect of Pharmacist-Led Intervention on Surgical Antibacterial Prophylaxis (SAP) at an Orthopedic Unit
Perioperative antibiotic use is a common reason for antibiotic misuse. Evidence suggests that adherence to SAP guidelines may improve outcomes. The purpose of this study was to analyze the impact of pharmacist-led antibiotic stewardship interventions on SAP guideline compliance. The study was conducted at an Orthopedic Department of a tertiary care medical center. SAP compliance and antibiotic exposure in the pre-intervention and intervention period was compared using chi-square, Fisher exact, and Mann-Whitney tests, as appropriate. Prophylactic antibiotic use in orthopedic joint arthroplasties (overall guideline adherence: agent, dose, frequency, duration), clinical outcomes (length of stay-LOS, number of surgical site infections-SSIs), antibiotic exposure and direct antibiotic costs were compared between pre-intervention and intervention periods. Significant improvement in mean SAP duration (by 42.9%, 4.08 ± 2.08 vs. 2.08 ± 1.90 days, p ˂ 0.001), and overall guideline adherence regarding antibiotic use (by 56.2%, from 2% to 58.2%, p ˂ 0.001) were observed. A significant decrease was observed in antibiotic exposure in SAP (by 41%, from 6.07 ± 0.05 to 3.58 ± 4.33 DDD/patient, p ˂ 0.001), average prophylactic antibiotic cost (by 54.8%, 9278.79 ± 6094.29 vs. 3598.16 ± 3354.55 HUF/patient), and mean LOS (by 37.2%, from 11.22 ± 6.96 to 7.62 ± 3.02 days, p < 0.001); and a slight decrease in the number of confirmed SSIs was found between the two periods (by 1.8%, from 3% to 1.2%, p = 0.21). Continuous presence of the clinical pharmacist led to significant improvement in SAP guideline adherence, which was accompanied by decreased antibiotic exposure and cost.
- Open Access
- 1 December 2020
- Published by University of Debrecen/ Debreceni Egyetem in Biomechanica Hungarica
- Vol. 13 (1) , 49-56
3D nyomtatás alapú cranioplasztika szilikon öntészeti módszerek és csontcement alkalmazásával
A koponyacsont veleszületett, vagy szerzett hiányainak pótlása az intracraniális tér különleges fizikai és élettani viszonyai miatt rendkívül fontos. Nem hanyagolható el a műtét esztétikai hatása sem. Az intézetünkben kidolgozott cranioplasztikai eljárás folyamán, a koponyáról készült vékony réteg CT felvételek 3D rekonstrukciója során az ép oldalt szoftveresen a sérült régióra tükrözzük, majd az átfedő pontokat kivonjuk egymásból. Így előállítható a defektus pótlására alkalmas alak-és méretpontos 3D modell. A sérült koponyarészletet kinyomtatva a pótlás pontos illeszkedése könnyen ellenőrizhető, probléma esetén a modell módosítható. A végleges modellről sterilizálható szilikon öntőmintát készítünk, melynek felhasználásával műtét közben a megfelelő pótlás poly(methyl methacrylate) (PMMA) alapú csontcementből steril körülmények között kiönthető és beültethető. 2013-tól 2020-ig a Szegedi Tudományegyetem Általános Orvostudományi Karának Idegsebészeti Tanszékével és a Magyar Honvédség Egészségügyi Központ Honvédkórház Idegsebészeti Osztályával együttműködve 51 esetben készítettünk ezzel a módszerrel cranioplasztika öntőformát. Műtéttechnikai probléma nem volt. 2 beteg esetében 3 pótlást érintően lépett fel szeptikus, a bemutatott implantátum-előállító eljárástól független szövődmény, emiatt a pótlások eltávolítására kényszerültünk. Véleményünk szerint a 3D nyomtatási technológiával előállított szilikon öntőformában, csontcementből készülő egyedi implantátumok igen jó eredménnyel alkalmazhatóak a koponya csontos hiányainak pótlására.
- 1 December 2020
- Published by University of Debrecen/ Debreceni Egyetem in Biomechanica Hungarica
- Vol. 13 (1) , 49-56
Open Access3D nyomtatás alapú cranioplasztika szilikon öntészeti módszerek és csontcement alkalmazásával
A koponyacsont veleszületett, vagy szerzett hiányainak pótlása az intracraniális tér különleges fizikai és élettani viszonyai miatt rendkívül fontos. Nem hanyagolható el a műtét esztétikai hatása sem. Az intézetünkben kidolgozott cranioplasztikai eljárás folyamán, a koponyáról készült vékony réteg CT felvételek 3D rekonstrukciója során az ép oldalt szoftveresen a sérült régióra tükrözzük, majd az átfedő pontokat kivonjuk egymásból. Így előállítható a defektus pótlására alkalmas alak-és méretpontos 3D modell. A sérült koponyarészletet kinyomtatva a pótlás pontos illeszkedése könnyen ellenőrizhető, probléma esetén a modell módosítható. A végleges modellről sterilizálható szilikon öntőmintát készítünk, melynek felhasználásával műtét közben a megfelelő pótlás poly(methyl methacrylate) (PMMA) alapú csontcementből steril körülmények között kiönthető és beültethető. 2013-tól 2020-ig a Szegedi Tudományegyetem Általános Orvostudományi Karának Idegsebészeti Tanszékével és a Magyar Honvédség Egészségügyi Központ Honvédkórház Idegsebészeti Osztályával együttműködve 51 esetben készítettünk ezzel a módszerrel cranioplasztika öntőformát. Műtéttechnikai probléma nem volt. 2 beteg esetében 3 pótlást érintően lépett fel szeptikus, a bemutatott implantátum-előállító eljárástól független szövődmény, emiatt a pótlások eltávolítására kényszerültünk. Véleményünk szerint a 3D nyomtatási technológiával előállított szilikon öntőformában, csontcementből készülő egyedi implantátumok igen jó eredménnyel alkalmazhatóak a koponya csontos hiányainak pótlására.
- Open Access
- 31 October 2020
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 21 (21) , 8172
Heme-Induced Oxidation of Cysteine Groups of Myofilament Proteins Leads to Contractile Dysfunction of Permeabilized Human Skeletal Muscle Fibres
Heme released from red blood cells targets a number of cell components including the cytoskeleton. The purpose of the present study was to determine the impact of free heme (20–300 µM) on human skeletal muscle fibres made available during orthopedic surgery. Isometric force production and oxidative protein modifications were monitored in permeabilized skeletal muscle fibre segments. A single heme exposure (20 µM) to muscle fibres decreased Ca2+-activated maximal (active) force (Fo) by about 50% and evoked an approximately 3-fold increase in Ca2+-independent (passive) force (Fpassive). Oxidation of sulfhydryl (SH) groups was detected in structural proteins (e.g., nebulin, α-actinin, meromyosin 2) and in contractile proteins (e.g., myosin heavy chain and myosin-binding protein C) as well as in titin in the presence of 300 µM heme. This SH oxidation was not reversed by dithiothreitol (50 mM). Sulfenic acid (SOH) formation was also detected in the structural proteins (nebulin, α-actinin, meromyosin). Heme effects on SH oxidation and SOH formation were prevented by hemopexin (Hpx) and α1-microglobulin (A1M). These data suggest that free heme has a significant impact on human skeletal muscle fibres, whereby oxidative alterations in structural and contractile proteins limit contractile function. This may explain and or contribute to the weakness and increase of skeletal muscle stiffness in chronic heart failure, rhabdomyolysis, and other hemolytic diseases. Therefore, therapeutic use of Hpx and A1M supplementation might be effective in preventing heme-induced skeletal muscle alterations.
- 31 October 2020
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 21 (21) , 8172
Open AccessHeme-Induced Oxidation of Cysteine Groups of Myofilament Proteins Leads to Contractile Dysfunction of Permeabilized Human Skeletal Muscle Fibres
Heme released from red blood cells targets a number of cell components including the cytoskeleton. The purpose of the present study was to determine the impact of free heme (20–300 µM) on human skeletal muscle fibres made available during orthopedic surgery. Isometric force production and oxidative protein modifications were monitored in permeabilized skeletal muscle fibre segments. A single heme exposure (20 µM) to muscle fibres decreased Ca2+-activated maximal (active) force (Fo) by about 50% and evoked an approximately 3-fold increase in Ca2+-independent (passive) force (Fpassive). Oxidation of sulfhydryl (SH) groups was detected in structural proteins (e.g., nebulin, α-actinin, meromyosin 2) and in contractile proteins (e.g., myosin heavy chain and myosin-binding protein C) as well as in titin in the presence of 300 µM heme. This SH oxidation was not reversed by dithiothreitol (50 mM). Sulfenic acid (SOH) formation was also detected in the structural proteins (nebulin, α-actinin, meromyosin). Heme effects on SH oxidation and SOH formation were prevented by hemopexin (Hpx) and α1-microglobulin (A1M). These data suggest that free heme has a significant impact on human skeletal muscle fibres, whereby oxidative alterations in structural and contractile proteins limit contractile function. This may explain and or contribute to the weakness and increase of skeletal muscle stiffness in chronic heart failure, rhabdomyolysis, and other hemolytic diseases. Therefore, therapeutic use of Hpx and A1M supplementation might be effective in preventing heme-induced skeletal muscle alterations.
- 31 December 2010
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 131 (7) , 1007-1012
Biomechanical comparison of three cemented stem removal techniques in revision hip surgery
There are various techniques available to remove a cemented femoral component and distal cement in the case of septic or aseptic loosening, periprosthetic or component fracture. The present study describes the mechanical effects of three techniques: the transfemoral approach (TFA), the distal fenestration technique (DF) and the retrograde stem removal technique (RSR). An experiment on cadaveric femora was performed to establish if there are any differences in the resistance to fracture in and between the various groups.
- 31 December 2010
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 131 (7) , 1007-1012
Biomechanical comparison of three cemented stem removal techniques in revision hip surgery
There are various techniques available to remove a cemented femoral component and distal cement in the case of septic or aseptic loosening, periprosthetic or component fracture. The present study describes the mechanical effects of three techniques: the transfemoral approach (TFA), the distal fenestration technique (DF) and the retrograde stem removal technique (RSR). An experiment on cadaveric femora was performed to establish if there are any differences in the resistance to fracture in and between the various groups.