Derya Burcu Özkan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Derya Burcu Özkan has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Cüneyt Deniz Küheylan
Department of Mechanical Engineering, Faculty of Mechanical Engineering, Yildiz Technical University, 34349 Istanbul, Turkey
1 shared publication - M. Handan Çubuk
Yildiz Technical University, Mechanical Eng.Dep., Istanbul, Turkey
1 shared publication - Omer Alp Ati̇ci̇
Department of Mechanical Engineering, Faculty of Mechanical Engineering, Yildiz Technical University, 34349 Istanbul, Turkey
1 shared publication Özlem Emanet
Yıldız Technical University
1 shared publication
Latest Publications
- Open Access
- 16 July 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (14) , 6194
Experimental and Theoretical Investigation of Thermal Parameters Influencing the Freezing Process of Ice Cream
Freezing time stands out as the most critical parameter in ice cream production, significantly influencing the final product’s quality and production efficiency. Therefore, it is essential to accurately estimate the freezing time based on ice cream recipes. This research paper focuses on determining the thermal properties of ice cream samples by leveraging insights from previous studies. Moreover, a new specific heat correlation is proposed to account for the latent heat effect of water during the freezing process. The results demonstrated that the new specific heat correlation aligns well with established formulas from previous research as well as experimental results with maximum 2.5% deviation. To validate the accuracy of the proposed numerical model, experimental studies were compared with numerical results for the first time in the context of ice cream freezing inside a mold. Additionally, a parametric analysis was conducted using numerical modelling to discern the relative importance of various production process parameters. Notably, the glycol–water mixture temperature emerged as the most influential parameter affecting freezing time, while the amount of air inside the ice cream was identified as the least significant factor.
- 16 July 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (14) , 6194
Open AccessExperimental and Theoretical Investigation of Thermal Parameters Influencing the Freezing Process of Ice Cream
Freezing time stands out as the most critical parameter in ice cream production, significantly influencing the final product’s quality and production efficiency. Therefore, it is essential to accurately estimate the freezing time based on ice cream recipes. This research paper focuses on determining the thermal properties of ice cream samples by leveraging insights from previous studies. Moreover, a new specific heat correlation is proposed to account for the latent heat effect of water during the freezing process. The results demonstrated that the new specific heat correlation aligns well with established formulas from previous research as well as experimental results with maximum 2.5% deviation. To validate the accuracy of the proposed numerical model, experimental studies were compared with numerical results for the first time in the context of ice cream freezing inside a mold. Additionally, a parametric analysis was conducted using numerical modelling to discern the relative importance of various production process parameters. Notably, the glycol–water mixture temperature emerged as the most influential parameter affecting freezing time, while the amount of air inside the ice cream was identified as the least significant factor.
- Open Access
- 6 July 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (13) , 5908
Experimental and Theoretical Study of Heat Transfer in a Chilled Ceiling System
Radiant cooling has been growing in recent years due to energy savings and improved comfort and health. The aim of this study was to reduce energy consumption and provide comfort using a chilled ceiling panel in the zone. In the experimental part of this study, a test room was created to investigate the change in the heat transfer performance of a chilled ceiling panel according to different water temperatures, different water flow rates and different heat source values. As a result of the experimental study, it was found that optimum conditions were achieved with a heat rate of 280 Watts and the lowest supply water temperature of 14 °C, with indoor comfort conditions being achieved with water flow rates of 0.93 m3/h. In the theoretical part of this study, a thermal balance was established for ceiling panel cooling applications. An analytical model of the heat transfer between the cold ceiling panel and the room air was also developed. The convection coefficient, convective heat transfer and total heat transfer coefficient were compared using the values obtained from the experiments and those reported in the literature. It was found that the convection coefficient was within the range reported in the literature, and the radiation heat coefficient was within 99.8% of the literature values.
- 6 July 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (13) , 5908
Open AccessExperimental and Theoretical Study of Heat Transfer in a Chilled Ceiling System
Radiant cooling has been growing in recent years due to energy savings and improved comfort and health. The aim of this study was to reduce energy consumption and provide comfort using a chilled ceiling panel in the zone. In the experimental part of this study, a test room was created to investigate the change in the heat transfer performance of a chilled ceiling panel according to different water temperatures, different water flow rates and different heat source values. As a result of the experimental study, it was found that optimum conditions were achieved with a heat rate of 280 Watts and the lowest supply water temperature of 14 °C, with indoor comfort conditions being achieved with water flow rates of 0.93 m3/h. In the theoretical part of this study, a thermal balance was established for ceiling panel cooling applications. An analytical model of the heat transfer between the cold ceiling panel and the room air was also developed. The convection coefficient, convective heat transfer and total heat transfer coefficient were compared using the values obtained from the experiments and those reported in the literature. It was found that the convection coefficient was within the range reported in the literature, and the radiation heat coefficient was within 99.8% of the literature values.
- 1 January 2010
- Published by Springer Nature
- p. 931-941
NOx Formation of Co-combustion of Sweet Sorghum – Lignite (Orhaneli) Mixtures in Fluidised Beds
- 1 January 2010
- Published by Springer Nature
- p. 931-941
NOx Formation of Co-combustion of Sweet Sorghum – Lignite (Orhaneli) Mixtures in Fluidised Beds