Feng Mei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Feng Mei has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Bo Pan
Harbin Institute of Technology Nan Gang Harbin People's Republic of China
1 shared publicationChang Liu
Fourth Hospital of Harbin Medical University Harbin People's Republic of China
1 shared publicationFu Yili
School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, People’s Republic of China
1 shared publicationPan Bo
School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, People’s Republic of China
1 shared publicationYili Fu
Harbin Institute of Technology Nan Gang Harbin People's Republic of China
1 shared publicationZhao Xudong
School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, People’s Republic of China
1 shared publication
Latest Publications
- 23 May 2012
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 226 (8) , 623-630
An improved surgical instrument without coupled motions that can be used in robotic-assisted minimally invasive surgery
In order to enhance the dexterity of surgical instruments in robotic-assisted minimally invasive surgery, the robot is generally configured so as to have a wrist. However, this configuration has a problem in that there is a coupling of the motions of the wrist and the end-effector. In this paper an improved surgical instrument is proposed that eliminates the coupled motion using a compensation mechanism. The design concept behind the compensation mechanism can be applied to other types of surgical instruments. The performance of the proposed surgical instrument is validated by mechanical performance testing and animal experiments, which indicate that the problem of the coupled motion is successfully solved and the instrument is able to perform surgical tasks.
- 23 May 2012
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 226 (8) , 623-630
An improved surgical instrument without coupled motions that can be used in robotic-assisted minimally invasive surgery
In order to enhance the dexterity of surgical instruments in robotic-assisted minimally invasive surgery, the robot is generally configured so as to have a wrist. However, this configuration has a problem in that there is a coupling of the motions of the wrist and the end-effector. In this paper an improved surgical instrument is proposed that eliminates the coupled motion using a compensation mechanism. The design concept behind the compensation mechanism can be applied to other types of surgical instruments. The performance of the proposed surgical instrument is validated by mechanical performance testing and animal experiments, which indicate that the problem of the coupled motion is successfully solved and the instrument is able to perform surgical tasks.
- 11 October 2011
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 8 (1) , 85-96
Development of a medical robot system for minimally invasive surgery
Background: Robot‐assisted systems have been widely used in minimally invasive surgery (MIS) practice, and with them the precision and accuracy of surgical procedures can be significantly improved. Promoting the development of robot technology in MIS will improve robot performance and help in tackling problems from complex surgical procedures.Methods: A medical robot system with a new mechanism for MIS was proposed to achieve a two‐dimensional (2D) remote centre of motion (RCM). An improved surgical instrument was designed to enhance manipulability and eliminate the coupling motion between the wrist and the grippers. The control subsystem adopted a master–slave control mode, upon which a new method with error compensation of repetitive feedback can be based for the inverse kinematics solution. A unique solution with less computation and higher satisfactory accuracy was also obtained. Tremor filtration and trajectory planning were also addressed with regard to the smoothness of the surgical instrument movement.Results: The robot system was tested on pigs weighing 30–45 kg. The experimental results show that the robot can successfully complete a cholecystectomy and meet the demands of MIS.Conclusions: The results of the animal experiments were excellent, indicating a promising clinical application of the robot with high manipulability. Copyright © 2011 John Wiley & Sons, Ltd.
- 11 October 2011
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 8 (1) , 85-96
Development of a medical robot system for minimally invasive surgery
Background: Robot‐assisted systems have been widely used in minimally invasive surgery (MIS) practice, and with them the precision and accuracy of surgical procedures can be significantly improved. Promoting the development of robot technology in MIS will improve robot performance and help in tackling problems from complex surgical procedures.Methods: A medical robot system with a new mechanism for MIS was proposed to achieve a two‐dimensional (2D) remote centre of motion (RCM). An improved surgical instrument was designed to enhance manipulability and eliminate the coupling motion between the wrist and the grippers. The control subsystem adopted a master–slave control mode, upon which a new method with error compensation of repetitive feedback can be based for the inverse kinematics solution. A unique solution with less computation and higher satisfactory accuracy was also obtained. Tremor filtration and trajectory planning were also addressed with regard to the smoothness of the surgical instrument movement.Results: The robot system was tested on pigs weighing 30–45 kg. The experimental results show that the robot can successfully complete a cholecystectomy and meet the demands of MIS.Conclusions: The results of the animal experiments were excellent, indicating a promising clinical application of the robot with high manipulability. Copyright © 2011 John Wiley & Sons, Ltd.