    Quantitative Imaging With a Pinhole Cardiac SPECT CZT Camera

    by Amir Pourmoghaddas, Amir

    This work develops methods to quantify absolute activity measurements with a multi-head pinhole cardiac SPECT camera that uses cadmium-zinc-telluride (CZT) detectors (Discovery NM530c, GE Healthcare). A central component of absolute activity quantification is the correction for Compton scattered photons. A modified Dual Energy Window (DEW) scatter correction (SC) method was developed that compensates for the presence of unscattered photons in the lower-energy window used to measure scatter. The DEW-SC method was validated using phantom experiments. The mean error in absolute activity measurement was 5 ± 4 % when correcting for attenuation, scatter and the partial volume effects. Clinical accuracy was assessed using 99mTc-tetrofosmin myocardial perfusion images obtained on the NM530c and comparing to DEW scatter-corrected images acquired on a conventional SPECT camera for the same patient. DEW-SC images acquired on the NM530c had increased noise but had summed perfusion scores that were not significantly different from those acquired on the conventional SPECT camera. To reduce noise in scatter corrected images and provide a more accurate estimate of scatter, a model-based SC method was developed based on the analytical photon distribution (APD) approach. Using physical phantom experiments and a set of five clinical studies, the accuracy of APD-SC was evaluated and compared to DEW-SC. Images generated using the model-based method agreed well with acquired data. APD-SC images had lower noise than DEW-SC images and provided a more accurate measure of cardiac activity in high-scatter scenarios. The developed methods provide an accurate means of correcting for scatter and thereby allow the absolute quantification of pinhole cardiac SPECT images.

  • Analytically based photon scatter modeling for a multipinhole cardiac SPECT camera

    by Amir Pourmoghaddas, R. Glenn Wells

    Purpose: Dedicated cardiac SPECT scanners have improved performance over standard gamma cameras allowing reductions in acquisition times and/or injected activity. One approach to improving performance has been to use pinhole collimators, but this can cause position‐dependent variations in attenuation, sensitivity, and spatial resolution. CT attenuation correction (AC) and an accurate system model can compensate for many of these effects; however, scatter correction (SC) remains an outstanding issue. In addition, in cameras using cadmium‐zinc‐telluride‐based detectors, a large portion of unscattered photons is detected with reduced energy (low‐energy tail). Consequently, application of energy‐based SC approaches in these cameras leads to a higher increase in noise than with standard cameras due to the subtraction of true counts detected in the low‐energy tail. Model‐based approaches with parallel‐hole collimator systems accurately calculate scatter based on the physics of photon interactions in the patient and camera and generate lower‐noise estimates of scatter than energy‐based SC. In this study, the accuracy of a model‐based SC method was assessed using physical phantom studies on the GE‐Discovery NM530c and its performance was compared to a dual energy window (DEW)‐SC method.Methods: The analytical photon distribution (APD) method was used to calculate the distribution of probabilities that emitted photons will scatter in the surrounding scattering medium and be subsequently detected. APD scatter calculations for 99mTc‐SPECT (140 ± 14 keV) were validated with point‐source measurements and 15 anthropomorphic cardiac‐torso phantom experiments and varying levels of extra‐cardiac activity causing scatter inside the heart. The activity inserted into the myocardial compartment of the phantom was first measured using a dose calibrator. CT images were acquired on an Infinia Hawkeye (GE Healthcare) SPECT/CT and coregistered with emission data for AC. For comparison, DEW scatter projections (120 ± 6 keV) were also extracted from the acquired list‐mode SPECT data. Either APD or DEW scatter projections were subtracted from corresponding 140 keV measured projections and then reconstructed with AC (APD‐SC and DEW‐SC). Quantitative accuracy of the activity measured in the heart for the APD‐SC and DEW‐SC images was assessed against dose calibrator measurements. The difference between modeled and acquired projections was measured as the root‐mean‐squared‐error (RMSE). APD‐modeled projections for a clinical cardiac study were also evaluated.Results: APD‐modeled projections showed good agreement with SPECT measurements and had reduced noise compared to DEW scatter estimates. APD‐SC reduced mean error in activity measurement compared to DEW‐SC in images and the reduction was statistically significant where the scatter fraction (SF) was large (mean SF = 28.5%, T‐test p = 0.007). APD‐SC reduced measurement uncertainties as well; however, the difference was not found to be statistically significant (F‐test p > 0.5). RMSE comparisons showed that elevated levels of scatter did not significantly contribute to a change in RMSE (p > 0.2).Conclusions: Model‐based APD scatter estimation is feasible for dedicated cardiac SPECT scanners with pinhole collimators. APD‐SC images performed better than DEW‐SC images and improved the accuracy of activity measurement in high‐scatter scenarios.


  • Use of Radiolabeled Compounds and Imaging as Cardiac Biomarkers

    by Ran Klein, Amir Pourmoghaddas, Brian Mc Ardle, Benjamin J. W. Chow

  • Scatter correction improves concordance in SPECT MPI with a dedicated cardiac SPECT solid-state camera

    by Amir Pourmoghaddas, Karen Vanderwerf, Terrence D. Ruddy, R. Glenn Wells


  • Respiratory phase alignment improves blood-flow quantification in Rb82 PET myocardial perfusion imaging

    by Amir Pourmoghaddas, Ran Klein, Robert A. Dekemp, R. Glenn Wells

    Purpose: Positron emission tomography (PET) is considered the gold standard for measuring myocardial blood flowin vivo but it is known that respiratory motion can lead to misalignment of the PET and...