    Configuration Approaches of CFAST for Prediction of Smoke and Heat Detector Activation Times in Corridor Fires

    by Hyo-Yeon Jang, Cheol-Hong Hwang

    In performance-based design for domestic buildings, there is a growing need for real-time comparison between the Available Safe Egress Time and Required Safe Egress Time through the integration of fire and evacuation simulations. Therefore, the utilization of the Consolidated Model of Fire and Smoke Transport (CFAST) has been discussed as an alternative to the Fire Dynamics Simulator (FDS), which has high computational costs; requires sufficient experience in the numerical calculation of fire dynamics, along with various input parameters; and has limitations in coupling with evacuation simulations. In this study, the prediction performance of CFAST for the activation times of smoke and heat detectors was evaluated. Specifically, it is essential to configure the mass movement between adjacent computational regions for smoke concentration. For achieving adequate predictive performance, the temperature should be determined according to the ceiling jet velocity generated by the fire source. Therefore, a method for setting a computational domain that can produce reasonable prediction results while considering the characteristics of CFAST for different types of smoke and heat detectors is proposed.


  • Open Access

    Preliminary Study for Smoke Color Classification of Combustibles Using the Distribution of Light Scattering by Smoke Particles

    by Hyo-Yeon Jang, Cheol-Hong Hwang

    Photoelectric smoke detectors are used for early detection of building fires, and sensitivity adjustment is generally performed using white smoke generated by the burning of filter paper. Therefore, when black smoke of the same concentration is introduced, the detector is often not activated. To address this problem, differences in the distribution of light scattered by smoke of various colors were analyzed. A light-scattering chamber with a light-receiving unit for various scattering angles was constructed to measure the scattered light generated inside the chamber of the smoke detector. The light scattering distribution was measured for smoke generated from three combustibles—filter paper (white smoke), kerosene (black smoke), and polyurethane (gray-black smoke)—and three analysis criteria were applied. By identifying a section where the measured values were concentrated for a specific analysis criterion and scattering angle, it was confirmed that some combustibles can be distinguished. Specifically, criterion III, a probabilistic section, was presented to determine which combustible smoke particles were close by applying the proposed section in a complex manner. A preliminary study was conducted to evaluate a methodology for the color classification of smoke particles flowing into a smoke detector chamber; this can be utilized as a foundation for determining optical properties.


  • Open Access

    Obscuration Threshold Database Construction of Smoke Detectors for Various Combustibles

    by Hyo-Yeon Jang, Cheol-Hong Hwang

    The obscuration thresholds for various smoke detectors and combustibles, required as an input parameter in fire simulation, were measured to predict the accurate activation time of detectors. One ionization detector and nine photoelectric detectors were selected. A fire detector evaluator, which can uniformly control the velocity and smoke concentration, was utilized. Filter paper, liquid fuels, and polymer pellets were employed as smoke-generation combustibles. The nominal obscuration thresholds of the considered detectors were 15 %/m, but the ionization detectors activated at approximately 40 %/m and 16 %/m, respectively, on applying filter paper and kerosene. In contrast, the reverse obscuration thresholds were found quantitatively according to the combustibles in the photoelectric detector. This phenomenon was caused by differences in the color of the smoke particles according to the combustibles, which is explained by single-scattering albedo (ratio of light scattering to light extinction). The obscuration thresholds for liquid fuels (kerosene, heptane and toluene) as well as fire types of polymer plastic pellets were also measured for several photoelectric detectors. A database of obscuration thresholds was thereby established according to the detector and combustible types, and it is expected to provide useful information for predicting more accurate detector activation time and required safe egress time (REST).