Jahirul Islam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jahirul Islam has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Rejvi Kaysir
Department of Electrical and Electronic Engineering (EEE), Khulna University of Engineering & Technology (KUET), Khulna, Bangladesh
10 shared publications - Elora Nahid
Department of Electrical and Electronic Engineering (EEE), Khulna University of Engineering & Technology (KUET), Khulna, Bangladesh
4 shared publications - Mohammad Shaifur Rahman
Department of Electrical and Electronic Engineering (EEE), Khulna University of Engineering & Technology (KUET), Khulna, Bangladesh
4 shared publications Rejvi Kaysir
4 shared publications- Sheikh Shahriar Hossain
Photonics Research Group, Department of EEE, KUET, Khulna, Bangladesh
4 shared publications Istiak Ahmed Ovi
Department of Materials Science and Engineering, Khulna University of Engineering & Technology (KUET), Khulna 9203, Bangladesh
2 shared publications
Latest Publications
- 1 September 2026
- Published by Springer Nature in Plasmonics
- Vol. 21 (10) , 3877-3892
Design and Numerical Analysis of a Chemically Stable and Highly Sensitive Ag/Pd Bimetallic SPR Sensor with ZnO Overlayer for Pathogenic Escherichia Coli Detection
- 1 September 2026
- Published by Springer Nature in Plasmonics
- Vol. 21 (10) , 3877-3892
Design and Numerical Analysis of a Chemically Stable and Highly Sensitive Ag/Pd Bimetallic SPR Sensor with ZnO Overlayer for Pathogenic Escherichia Coli Detection
- 21 July 2026
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 58 (10) , 428
Optical soliton evolution and interaction considering tunable frequency shift and self-steepening in cubic-quintic media
- 21 July 2026
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 58 (10) , 428
Optical soliton evolution and interaction considering tunable frequency shift and self-steepening in cubic-quintic media
- Open Access
- 11 May 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 16 (27) , 24378-24399
Theoretical study of GaBX 3 halide perovskites for optoelectronic and energy conversion applications
ABX 3 perovskite materials have shown great potential for optoelectronic applications in recent years.
- 11 May 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 16 (27) , 24378-24399
Open AccessTheoretical study of GaBX 3 halide perovskites for optoelectronic and energy conversion applications
ABX 3 perovskite materials have shown great potential for optoelectronic applications in recent years.
- Open Access
- 10 May 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (19) , 27931-27941
Noninvasive Blood Glucose Monitoring with Machine Learning Enhanced Transmittance Spectroscopy
Diabetes is a widespread metabolic disease in which the body’s inability to regulate blood glucose levels leads to severe health complications. Current limitations in noninvasive glucose sensing make finger-prick glucometers the standard for personal monitoring despite their discomfort and challenges for frequent measurements. By combining machine learning techniques with transmittance spectroscopy, this study presents a noninvasive approach for estimating BGL in personal healthcare. The system employs multispectral transmittance measurements at 650, 808, and 940 nm to evaluate glucose concentrations in aqueous solutions. Simulation of light absorption in skin layers and in vitro experiments identified 940 nm as the optimal wavelength, offering high sensitivity with minimal interference from water absorption. Using this wavelength, an in vivo system based on transmittance spectroscopy was developed for noninvasive glucose measurement. A machine learning pipeline incorporating ensemble models was implemented to predict glucose levels from optical data. Trained on 200 clinical samples obtained from the in vivo experimental setup, the XGBoost model outperformed other algorithms, achieving an R2 score of 0.94 with a root-mean-squared error (RMSE) of 23.92 mg/dL. The Clarke error grid analysis (CEGA) showed that 92.5% of predictions fell within Zone A and 7.5% within Zone B, with no samples in the critical zones (C–E), demonstrating the system’s robustness. These results highlight the potential of the proposed method as a practical, low-cost, and reliable solution for continuous noninvasive glucose monitoring in diabetes management.
- 10 May 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (19) , 27931-27941
Open AccessNoninvasive Blood Glucose Monitoring with Machine Learning Enhanced Transmittance Spectroscopy
Diabetes is a widespread metabolic disease in which the body’s inability to regulate blood glucose levels leads to severe health complications. Current limitations in noninvasive glucose sensing make finger-prick glucometers the standard for personal monitoring despite their discomfort and challenges for frequent measurements. By combining machine learning techniques with transmittance spectroscopy, this study presents a noninvasive approach for estimating BGL in personal healthcare. The system employs multispectral transmittance measurements at 650, 808, and 940 nm to evaluate glucose concentrations in aqueous solutions. Simulation of light absorption in skin layers and in vitro experiments identified 940 nm as the optimal wavelength, offering high sensitivity with minimal interference from water absorption. Using this wavelength, an in vivo system based on transmittance spectroscopy was developed for noninvasive glucose measurement. A machine learning pipeline incorporating ensemble models was implemented to predict glucose levels from optical data. Trained on 200 clinical samples obtained from the in vivo experimental setup, the XGBoost model outperformed other algorithms, achieving an R2 score of 0.94 with a root-mean-squared error (RMSE) of 23.92 mg/dL. The Clarke error grid analysis (CEGA) showed that 92.5% of predictions fell within Zone A and 7.5% within Zone B, with no samples in the critical zones (C–E), demonstrating the system’s robustness. These results highlight the potential of the proposed method as a practical, low-cost, and reliable solution for continuous noninvasive glucose monitoring in diabetes management.
- 13 January 2026
- Published by Springer Nature in Plasmonics
- Vol. 21 (2) , 1701-1714
Comparative Study of Analytical and Numerical Models of Solid-core Optical Fiber SPR Sensor For Refractive Index Sensing
- 13 January 2026
- Published by Springer Nature in Plasmonics
- Vol. 21 (2) , 1701-1714
Comparative Study of Analytical and Numerical Models of Solid-core Optical Fiber SPR Sensor For Refractive Index Sensing
- 28 November 2025
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 57 (12) , 663
Development of dual-parametric complementary split ring resonator-based microstrip patch antenna sensor for non-invasive blood glucose monitoring
- 28 November 2025
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 57 (12) , 663
Development of dual-parametric complementary split ring resonator-based microstrip patch antenna sensor for non-invasive blood glucose monitoring
- Open Access
- 18 November 2025
- Published by Atlantis Press SARL
- p. 614-621
Implementation of Machine Learning Assisted PPG-based Non-Invasive Blood Glucose Monitoring System
- 18 November 2025
- Published by Atlantis Press SARL
- p. 614-621
Open AccessImplementation of Machine Learning Assisted PPG-based Non-Invasive Blood Glucose Monitoring System
- Open Access
- 22 October 2025
- Published by Springer Nature in Research Square
Development of Dual-Parametric CSRR-Based MPA Sensor for Non-Invasive Blood Glucose Monitoring
A complementary split ring resonator (CSRR)-based microstrip patch sensor is presented for noninvasive estimation of blood glucose concentration. The device employs a triangular patch with a CSRR etched in the ground plane to realize two ISM bands: 2.42–2.62 GHz for wireless telemetry and 5.17–5.24 GHz for sensing, where the structure operates as a microwave resonator. Geometry and feed parameters were optimized to sharpen the S-parameter response and improve glucose-dependent sensitivity. A multilayer human-thumb phantom was constructed, and blood glucose level was swept from 100 to 300 mg/dL to quantify frequency-selective detection while complying with safety constraints. Changes in glucose level alter the tissue permittivity in the resonator-finger configuration, resulting in measurable shifts in resonant frequency and S 11 magnitude, which enables a dual-parameter readout. The prototype exhibits frequency sensitivity of 160 kHz/mg·dL⁻¹ and magnitude sensitivity of 0.0654 dB/mg·dL⁻¹. The sensor was fabricated using conventional PCB etching to validate the simulated design. The measured S-parameters closely follow simulations with minor deviations attributable to fabrication tolerances and tissue-model simplifications. Specific absorption rate (SAR) analysis yields 0.397 W/kg averaged over 1 g of tissue, within commonly accepted IEEE exposure limits. The compact, low-cost, dual-band architecture and dual-parameter sensing indicate strong potential for real-time, noninvasive glucose monitoring and future integration into wearable systems.
- 22 October 2025
- Published by Springer Nature in Research Square
Open AccessDevelopment of Dual-Parametric CSRR-Based MPA Sensor for Non-Invasive Blood Glucose Monitoring
A complementary split ring resonator (CSRR)-based microstrip patch sensor is presented for noninvasive estimation of blood glucose concentration. The device employs a triangular patch with a CSRR etched in the ground plane to realize two ISM bands: 2.42–2.62 GHz for wireless telemetry and 5.17–5.24 GHz for sensing, where the structure operates as a microwave resonator. Geometry and feed parameters were optimized to sharpen the S-parameter response and improve glucose-dependent sensitivity. A multilayer human-thumb phantom was constructed, and blood glucose level was swept from 100 to 300 mg/dL to quantify frequency-selective detection while complying with safety constraints. Changes in glucose level alter the tissue permittivity in the resonator-finger configuration, resulting in measurable shifts in resonant frequency and S 11 magnitude, which enables a dual-parameter readout. The prototype exhibits frequency sensitivity of 160 kHz/mg·dL⁻¹ and magnitude sensitivity of 0.0654 dB/mg·dL⁻¹. The sensor was fabricated using conventional PCB etching to validate the simulated design. The measured S-parameters closely follow simulations with minor deviations attributable to fabrication tolerances and tissue-model simplifications. Specific absorption rate (SAR) analysis yields 0.397 W/kg averaged over 1 g of tissue, within commonly accepted IEEE exposure limits. The compact, low-cost, dual-band architecture and dual-parameter sensing indicate strong potential for real-time, noninvasive glucose monitoring and future integration into wearable systems.
- 18 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (21) , 39802-39810
DLC–TiO₂–Au-Coated D-Shaped SPR Biosensor for Cancer Cell Detection
This study proposes and optimizes a novel highly sensitive D-shaped photonic crystal fiber (PCF)-based surface plasmon resonance (SPR) biosensor incorporating a diamond-like carbon (DLC)-TiO2-Au multilayer structure for the detection of six types of cancer cells, such as MDA-MB-231, Jurkat, MCF-7, Basal, PC12, and HeLa. The assessment of the key performance parameters of the proposed sensor is carried out using numerical simulations with the finite element method (FEM). Both wavelength and amplitude interrogations are performed for the detection of different cancer cells. Numerical results show a maximum wavelength sensitivity of 32,142.86 nm/RIU, and a minimum resolution of 3.11×10-6 RIU for MCF-7 cell detection using x polarized light. Additionally, the DLC-TiO2-Au sensor structure exhibits a peak wavelength sensitivity of 80,000 nm/RIU under x polarized light, which makes it a suitable sensor as a general refractive index (RI) detector over a wide range of analytes with RI values ranging from 1 to 1.401. The statistical results demonstrate that the sensor has a considerably high level of sensitivity and selectivity, which makes it an effective tool in cancer diagnostics through early and accurate detection due to its increased sensitivity and resolution.
- 18 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (21) , 39802-39810
DLC–TiO₂–Au-Coated D-Shaped SPR Biosensor for Cancer Cell Detection
This study proposes and optimizes a novel highly sensitive D-shaped photonic crystal fiber (PCF)-based surface plasmon resonance (SPR) biosensor incorporating a diamond-like carbon (DLC)-TiO2-Au multilayer structure for the detection of six types of cancer cells, such as MDA-MB-231, Jurkat, MCF-7, Basal, PC12, and HeLa. The assessment of the key performance parameters of the proposed sensor is carried out using numerical simulations with the finite element method (FEM). Both wavelength and amplitude interrogations are performed for the detection of different cancer cells. Numerical results show a maximum wavelength sensitivity of 32,142.86 nm/RIU, and a minimum resolution of 3.11×10-6 RIU for MCF-7 cell detection using x polarized light. Additionally, the DLC-TiO2-Au sensor structure exhibits a peak wavelength sensitivity of 80,000 nm/RIU under x polarized light, which makes it a suitable sensor as a general refractive index (RI) detector over a wide range of analytes with RI values ranging from 1 to 1.401. The statistical results demonstrate that the sensor has a considerably high level of sensitivity and selectivity, which makes it an effective tool in cancer diagnostics through early and accurate detection due to its increased sensitivity and resolution.