SFS. Flohr‐Madsen

S. Flohr‐Madsen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


S. Flohr‐Madsen has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • L. M. Ytrebø

    Department of Anaesthesiology University Hospital of North Norway Tromsø Norway

    1 shared publication
  • S. Kregnes

    Department of Anaesthesiology University Hospital of North Norway Tromsø Norway

    1 shared publication
  • T. Wilsgaard

    Department of Community Medicine University of Tromsø Tromsø Norway

    1 shared publication
  • Ø. Klaastad

    Department of Anaesthesiology University Hospital of North Norway Tromsø Norway

    1 shared publication

Latest Publications

  • Minimum effective volume of ropivacaine 7.5 mg/ml for an ultrasound‐guided infraclavicular brachial plexus block

    by S. Flohr‐Madsen, L. M. Ytrebø, S. Kregnes, T. Wilsgaard, Ø. Klaastad

    Background: Ultrasound guidance has been shown to reduce the minimum effective volume (MEV) of local anaesthetics for several peripheral nerve blocks. Although the lateral sagittal infraclavicular block (LSIB) is a well‐established anaesthesia method, MEV for this technique has not been established. Our aim with this study was to determine the MEV using ropivacaine 7.5 mg/ml for the LSIB method.Methods: Twenty‐five adult American Society of Anesthesiologists physical status I‐II patients scheduled for hand surgery received an ultrasound‐guided LSIB with ropivacaine 7.5 mg/ml. A successful block was defined as anaesthesia or analgesia for all five sensory nerves distal to the elbow, 30 min after local anaesthetic injection. The MEV for a successful block in 50% of the patients was determined by using the staircase up‐and‐down method introduced by Dixon and Massey. Logistic regression and probit transformation were applied to estimate the MEV for a successful block in 95% of the patients.Results: The patients received ropivacaine 7.5 mg/ml volumes in the range of 12.5–30 ml. The MEVs in 50% and 95% of the patients were 19 ml [95% confidence interval (CI), 14–27] and 31 ml (95% CI, 18–45), respectively.Conclusions: For surgery distal to the elbow, the MEV in 95% of patients for an ultrasound‐guided LSIB with ropivacaine 7.5 mg/ml was estimated to be 31 ml (95% CI, 18–45 ml). Further studies should determine the factors that influence the volume of local anaesthetic required for a successful infraclavicular block.