Christian Vinther Bertelsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Christian Vinther Bertelsen has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Maria Dimaki
DTU Bioengineering Danmarks Tekniske Universitet (DTU) Kongens Lyngby 2800 Denmark
4 shared publications- Winnie Edith Svendsen
Technical University of Denmark
4 shared publications Winnie Edith Svendsen
Danmarks Tekn Univ DTU, DTU Bioengn, DK-2800 Lyngby, Denmark
3 shared publications- Albert Romano-Rodriguez
Department of Electronic and Biomedical Engineering, University of Barcelona, 08028 Barcelona, Spain
2 shared publications - Daniel Navarro Urrios
University of Barcelona
2 shared publications - David Alonso-Tomás
MIND-IN2UB, Departament d’Enginyeria Electrónica i Biomédica, Facultat de Física, Universitat de Barcelona
2 shared publications
Latest Publications
- Open Access
- 11 October 2025
- Published by Wiley in Advanced Materials Interfaces
- Vol. 13 (4)
Enhancing Grayscale E‐Beam Lithography: Thermal Treatment of Novolak‐Based Resist for 3D Nanostructures
Grayscale electron beam lithography enables the direct writing of 3D nanostructures, which are essential for advanced applications in photonics, biomimetics, and surface engineering, by spatially modulating exposure dose. However, realizing high‐resolution grayscale features remains challenging due to dose‐dependent variations in resist morphology and limited control over nanoscale surface roughness. Here, a systematic study of the thermally induced morphological and chemical evolution of a novolak‐based negative resist commonly used in electron beam lithography is presented. Using atomic force microscopy, scanning electron microscopy, and X‐ray photoelectron spectroscopy, the impact of post‐exposure thermal treatment on surface roughness, chemical bonding, and deformation behavior across a wide range of exposure doses are evaluated. These results offer new insights into how e‐beam dose and thermal treatment interact and highlight potential of thermally optimized novolak resists for high‐precision 3D nanofabrication and highlights the potential of thermally optimized novolak resists for high‐precision 3D nanofabrication.
- 11 October 2025
- Published by Wiley in Advanced Materials Interfaces
- Vol. 13 (4)
Open AccessEnhancing Grayscale E‐Beam Lithography: Thermal Treatment of Novolak‐Based Resist for 3D Nanostructures
Grayscale electron beam lithography enables the direct writing of 3D nanostructures, which are essential for advanced applications in photonics, biomimetics, and surface engineering, by spatially modulating exposure dose. However, realizing high‐resolution grayscale features remains challenging due to dose‐dependent variations in resist morphology and limited control over nanoscale surface roughness. Here, a systematic study of the thermally induced morphological and chemical evolution of a novolak‐based negative resist commonly used in electron beam lithography is presented. Using atomic force microscopy, scanning electron microscopy, and X‐ray photoelectron spectroscopy, the impact of post‐exposure thermal treatment on surface roughness, chemical bonding, and deformation behavior across a wide range of exposure doses are evaluated. These results offer new insights into how e‐beam dose and thermal treatment interact and highlight potential of thermally optimized novolak resists for high‐precision 3D nanofabrication and highlights the potential of thermally optimized novolak resists for high‐precision 3D nanofabrication.
- Open Access
- 28 July 2025
- Published by Wiley in Nanophotonics
- Vol. 14 (17) , 2953-2961
Hybrid SiO 2 /Si pillar‐based optomechanical crystals for on‐chip photonic integration
One‐dimensional photonic crystal (1D‐PhC) pillar cavities allow transducing mechanical pillar vibrations to the optical domain, thereby relaxing the requirements typically associated with mechanical motion detection. In this study, we integrate these geometries into a silicon‐on‐insulator photonics platform and explore their optical and mechanical properties. The 1D‐PhC structures consist of a linear array of high aspect ratio nanopillars with nanometer‐sized diameters, designed to enhance the interaction between transverse‐magnetic (TM) polarized optical fields and mechanical vibrations and to minimize optical leaking to the substrate. Integrated waveguides are engineered to support TM‐like modes, which enable optimized coupling to the 1D‐PhC optical cavity modes via evanescent wave interaction. Finite element method simulations and experimental analyses reveal that these cavities achieve relatively high optical quality factors ( Q ∼ 4 × 10 3 ). In addition, both simulated and experimentally measured mechanical vibrational frequencies show large optomechanical coupling rates exceeding 1 MHz for the fundamental cantilever‐like modes. By tuning the separation between the 1D‐PhC and the waveguide, we achieve optimal optical coupling conditions that enable the transduction of thermally activated mechanical modes across a broad frequency range – from tens to several hundreds of MHz. This enhanced accessibility and efficiency in mechanical motion transduction significantly strengthens the viability of established microelectromechanical (MEMS) and nanoelectromechanical systems (NEMS) technologies based on nanowires, nanorods, and related structures, particularly in applications such as force sensing and biosensing.
- 28 July 2025
- Published by Wiley in Nanophotonics
- Vol. 14 (17) , 2953-2961
Open AccessHybrid SiO 2 /Si pillar‐based optomechanical crystals for on‐chip photonic integration
One‐dimensional photonic crystal (1D‐PhC) pillar cavities allow transducing mechanical pillar vibrations to the optical domain, thereby relaxing the requirements typically associated with mechanical motion detection. In this study, we integrate these geometries into a silicon‐on‐insulator photonics platform and explore their optical and mechanical properties. The 1D‐PhC structures consist of a linear array of high aspect ratio nanopillars with nanometer‐sized diameters, designed to enhance the interaction between transverse‐magnetic (TM) polarized optical fields and mechanical vibrations and to minimize optical leaking to the substrate. Integrated waveguides are engineered to support TM‐like modes, which enable optimized coupling to the 1D‐PhC optical cavity modes via evanescent wave interaction. Finite element method simulations and experimental analyses reveal that these cavities achieve relatively high optical quality factors ( Q ∼ 4 × 10 3 ). In addition, both simulated and experimentally measured mechanical vibrational frequencies show large optomechanical coupling rates exceeding 1 MHz for the fundamental cantilever‐like modes. By tuning the separation between the 1D‐PhC and the waveguide, we achieve optimal optical coupling conditions that enable the transduction of thermally activated mechanical modes across a broad frequency range – from tens to several hundreds of MHz. This enhanced accessibility and efficiency in mechanical motion transduction significantly strengthens the viability of established microelectromechanical (MEMS) and nanoelectromechanical systems (NEMS) technologies based on nanowires, nanorods, and related structures, particularly in applications such as force sensing and biosensing.
- Open Access
- 30 August 2024
- Published by Elsevier in Micro and Nano Engineering
- Vol. 25
Dry etch performance of Novolak-based negative e-beam resist
- 30 August 2024
- Published by Elsevier in Micro and Nano Engineering
- Vol. 25
Open AccessDry etch performance of Novolak-based negative e-beam resist
- Open Access
- 21 August 2024
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 18 (35) , 24550-24557
Strong Cavity-Optomechanical Transduction of Nanopillar Motion
Nanomechanical resonators can serve as ultrasensitive, miniaturized force probes. While vertical structures such as nanopillars are ideal for this purpose, transducing their motion is challenging. Pillar-based photonic crystals (PhCs) offer a potential solution by integrating optical transduction within the pillars. However, achieving high-quality PhCs is hindered by inefficient vertical light confinement. Here, we present a full-silicon photonic crystal cavity based on nanopillars as a platform for applications in force sensing and biosensing areas. Its unit cell consists of a silicon pillar with a larger diameter at its top portion than at the bottom, which allows vertical light confinement and an energy band gap in the near-infrared range for transverse-magnetic polarization. We experimentally demonstrate optical cavities with Q factors exceeding 103, constructed by inserting a defect within a periodic arrangement of this type of pillars. Each nanopillar naturally behaves as a nanomechanical cantilever, making the fabricated geometries excellent optomechanical (OM) photonic crystal cavities in which the mechanical motion of each nanopillar composing the cavity can be optically transduced. These geometries display enhanced mechanical properties, cost-effectiveness, integration possibilities, and scalability. They also present an alternative in front of the widely used suspended Si beam OM cavities made on silicon-on-insulator substrates.
- 21 August 2024
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 18 (35) , 24550-24557
Open AccessStrong Cavity-Optomechanical Transduction of Nanopillar Motion
Nanomechanical resonators can serve as ultrasensitive, miniaturized force probes. While vertical structures such as nanopillars are ideal for this purpose, transducing their motion is challenging. Pillar-based photonic crystals (PhCs) offer a potential solution by integrating optical transduction within the pillars. However, achieving high-quality PhCs is hindered by inefficient vertical light confinement. Here, we present a full-silicon photonic crystal cavity based on nanopillars as a platform for applications in force sensing and biosensing areas. Its unit cell consists of a silicon pillar with a larger diameter at its top portion than at the bottom, which allows vertical light confinement and an energy band gap in the near-infrared range for transverse-magnetic polarization. We experimentally demonstrate optical cavities with Q factors exceeding 103, constructed by inserting a defect within a periodic arrangement of this type of pillars. Each nanopillar naturally behaves as a nanomechanical cantilever, making the fabricated geometries excellent optomechanical (OM) photonic crystal cavities in which the mechanical motion of each nanopillar composing the cavity can be optically transduced. These geometries display enhanced mechanical properties, cost-effectiveness, integration possibilities, and scalability. They also present an alternative in front of the widely used suspended Si beam OM cavities made on silicon-on-insulator substrates.
- Open Access
- 16 February 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (8) , 7714-7721
Using Impedance Flow Cytometry for Rapid Viability Classification of Heat-Treated Bacteria
In the future, rapid electrical characterization of cells with impedance flow cytometry promises to be a fast and accurate method for the evaluation of cell properties. In this paper, we investigate how the conductivity of the suspending medium along with the heat exposure time affects the viability classification of heat-treated E. coli. Using a theoretical model, we show that perforation of the bacteria membrane during heat exposure changes the impedance of the bacterial cell from effectively less conducting than the suspension medium to effectively more conducting. Consequently, this results in a shift in the differential argument of the complex electrical current that can be measured with impedance flow cytometry. We observe this shift experimentally through measurements on E. coli samples with varying medium conductivity and heat exposure times. We show that increased exposure time and lower medium conductivity results in improved classification between untreated and heat-treated bacteria. The best classification was achieved with a medium conductivity of 0.045 S/m after 30 min of heat exposure.
- 16 February 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (8) , 7714-7721
Open AccessUsing Impedance Flow Cytometry for Rapid Viability Classification of Heat-Treated Bacteria
In the future, rapid electrical characterization of cells with impedance flow cytometry promises to be a fast and accurate method for the evaluation of cell properties. In this paper, we investigate how the conductivity of the suspending medium along with the heat exposure time affects the viability classification of heat-treated E. coli. Using a theoretical model, we show that perforation of the bacteria membrane during heat exposure changes the impedance of the bacterial cell from effectively less conducting than the suspension medium to effectively more conducting. Consequently, this results in a shift in the differential argument of the complex electrical current that can be measured with impedance flow cytometry. We observe this shift experimentally through measurements on E. coli samples with varying medium conductivity and heat exposure times. We show that increased exposure time and lower medium conductivity results in improved classification between untreated and heat-treated bacteria. The best classification was achieved with a medium conductivity of 0.045 S/m after 30 min of heat exposure.
- Open Access
Investigating the Use of Impedance Flow Cytometry for Classifying the Viability State of E. coli
Bacteria detection, counting and analysis is of great importance in several fields. When viability plays a major role in decision making, the counting of colony-forming units grown on agar plates remains the gold standard. However, because plate counts depend on the growth of the bacteria, it is a slow procedure and only works with culturable species. Impedance flow cytometry (IFC) is a promising technology for particle detection, counting and characterization. It relies on the perturbation of an electric field by particles flowing through a microfluidic channel. The perturbation is directly related to the electrical properties of the particles, and therefore provides information about their composition and structure. In this work we investigate whether IFC can be used to differentiate viable cells from inactivated cells. Our findings demonstrate that the specific viability state of the bacteria has to be considered, but that with proper characterization thresholds, IFC can be used to classify bacterial viability states. By using three different inactivation methods—ethanol, heat and autoclavation—we have been able to show that the impedance response of Escherichia coli depends on its viability state, but that the specific response depends on the inactivation method. With these findings we expect to be able to optimize IFC for more reliable bacteria detection and counting in the future.
Open AccessInvestigating the Use of Impedance Flow Cytometry for Classifying the Viability State of E. coli
Bacteria detection, counting and analysis is of great importance in several fields. When viability plays a major role in decision making, the counting of colony-forming units grown on agar plates remains the gold standard. However, because plate counts depend on the growth of the bacteria, it is a slow procedure and only works with culturable species. Impedance flow cytometry (IFC) is a promising technology for particle detection, counting and characterization. It relies on the perturbation of an electric field by particles flowing through a microfluidic channel. The perturbation is directly related to the electrical properties of the particles, and therefore provides information about their composition and structure. In this work we investigate whether IFC can be used to differentiate viable cells from inactivated cells. Our findings demonstrate that the specific viability state of the bacteria has to be considered, but that with proper characterization thresholds, IFC can be used to classify bacterial viability states. By using three different inactivation methods—ethanol, heat and autoclavation—we have been able to show that the impedance response of Escherichia coli depends on its viability state, but that the specific response depends on the inactivation method. With these findings we expect to be able to optimize IFC for more reliable bacteria detection and counting in the future.
- Open Access
Bacteria Detection and Differentiation Using Impedance Flow Cytometry
Monitoring of bacteria concentrations is of great importance in drinking water management. Continuous real-time monitoring enables better microbiological control of the water and helps prevent contaminated water from reaching the households. We have developed a microfluidic sensor with the potential to accurately assess bacteria levels in drinking water in real-time. Multi frequency electrical impedance spectroscopy is used to monitor a liquid sample, while it is continuously passed through the sensor. We investigate three aspects of this sensor: First we show that the sensor is able to differentiate Escherichia coli (Gram-negative) bacteria from solid particles (polystyrene beads) based on an electrical response in the high frequency phase and individually enumerate the two samples. Next, we demonstrate the sensor’s ability to measure the bacteria concentration by comparing the results to those obtained by the traditional CFU counting method. Last, we show the sensor’s potential to distinguish between different bacteria types by detecting different signatures for S. aureus and E. coli mixed in the same sample. Our investigations show that the sensor has the potential to be extremely effective at detecting sudden bacterial contaminations found in drinking water, and eventually also identify them.
Open AccessBacteria Detection and Differentiation Using Impedance Flow Cytometry
Monitoring of bacteria concentrations is of great importance in drinking water management. Continuous real-time monitoring enables better microbiological control of the water and helps prevent contaminated water from reaching the households. We have developed a microfluidic sensor with the potential to accurately assess bacteria levels in drinking water in real-time. Multi frequency electrical impedance spectroscopy is used to monitor a liquid sample, while it is continuously passed through the sensor. We investigate three aspects of this sensor: First we show that the sensor is able to differentiate Escherichia coli (Gram-negative) bacteria from solid particles (polystyrene beads) based on an electrical response in the high frequency phase and individually enumerate the two samples. Next, we demonstrate the sensor’s ability to measure the bacteria concentration by comparing the results to those obtained by the traditional CFU counting method. Last, we show the sensor’s potential to distinguish between different bacteria types by detecting different signatures for S. aureus and E. coli mixed in the same sample. Our investigations show that the sensor has the potential to be extremely effective at detecting sudden bacterial contaminations found in drinking water, and eventually also identify them.
- Open Access
- 30 December 2014
- Published by MDPI AG in Micromachines
- Vol. 6 (1) , 110-120
Coplanar Electrode Layout Optimized for Increased Sensitivity for Electrical Impedance Spectroscopy
This work describes an improvement in the layout of coplanar electrodes for electrical impedance spectroscopy. We have developed, fabricated, and tested an improved electrode layout, which improves the sensitivity of an impedance flow cytometry chip. The improved chip was experimentally tested and compared to a chip with a conventional electrode layout. The improved chip was able to discriminate 0.5 μm beads from 1 μm as opposed to the conventional chip. Furthermore, finite element modeling was used to simulate the improvements in electrical field density and uniformity between the electrodes of the new electrode layout. Good agreement was observed between the model and the obtained experimental results.
- 30 December 2014
- Published by MDPI AG in Micromachines
- Vol. 6 (1) , 110-120
Open AccessCoplanar Electrode Layout Optimized for Increased Sensitivity for Electrical Impedance Spectroscopy
This work describes an improvement in the layout of coplanar electrodes for electrical impedance spectroscopy. We have developed, fabricated, and tested an improved electrode layout, which improves the sensitivity of an impedance flow cytometry chip. The improved chip was experimentally tested and compared to a chip with a conventional electrode layout. The improved chip was able to discriminate 0.5 μm beads from 1 μm as opposed to the conventional chip. Furthermore, finite element modeling was used to simulate the improvements in electrical field density and uniformity between the electrodes of the new electrode layout. Good agreement was observed between the model and the obtained experimental results.
- Open Access
- 1 December 2014
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 220, 347-364
Silicon as an anisotropic mechanical material: Deflection of thin crystalline plates
- 1 December 2014
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 220, 347-364
Open AccessSilicon as an anisotropic mechanical material: Deflection of thin crystalline plates
- 1 September 2012
- Published by Elsevier in Microelectronic Engineering
- Vol. 97, 227-230
Reactive ion etching of polymer materials for an energy harvesting device
- 1 September 2012
- Published by Elsevier in Microelectronic Engineering
- Vol. 97, 227-230
Reactive ion etching of polymer materials for an energy harvesting device