Rajib Biswas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rajib Biswas has a total of 115 co-authors. Here are the top co-authors by number of shared publications:
- Nirmal Mazumder
Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, India
16 shared publications - Nilutpal Bora
Department of Civil Engineering, Indian Institute of Technology Guwahati, Guwahati, India
10 shared publications Upama Das
Applied Optics and Photonics Research Laboratory, Department of Physics, Tezpur University, Tezpur-784028, Assam, India
10 shared publicationsAshamoni Neog
9 shared publicationsVickey Sharma
Applied Geophysics Lab, Department of Physics, Tezpur University, Tezpur, India
7 shared publicationsNirmal Mazumder
Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
6 shared publications
Latest Publications
- 2 November 2026
- Published by Springer Nature in Journal of Optics
- p. 1-7
Deciphering refractive index of analytes via machine learning over simulated grating structures
- 2 November 2026
- Published by Springer Nature in Journal of Optics
- p. 1-7
Deciphering refractive index of analytes via machine learning over simulated grating structures
- 1 October 2026
- Published by Springer Nature in Earthquake Engineering and Engineering Vibration
- Vol. 25 (4) , 1195-1210
Pre-seismic patterns of logarithmic seismicity factor and quiescence for 2023 Kahramanmaraş earthquake, Türkiye
- 1 October 2026
- Published by Springer Nature in Earthquake Engineering and Engineering Vibration
- Vol. 25 (4) , 1195-1210
Pre-seismic patterns of logarithmic seismicity factor and quiescence for 2023 Kahramanmaraş earthquake, Türkiye
- 21 September 2026
- Published by Wiley in Geological Journal
Understanding the Seismicity Pattern Across the Eastern Himalayan Region by Means of Spatiotemporal Variations in the Seismic b ‐Value
Himalayan earthquakes are triggered by the release of accumulated strain driven by tectonic forces. The different geological settings of the Himalayan Seismic belt contribute to the inhomogeneous seismicity profile of the region. In this study, we estimated the spatial and temporal variation of seismicity using a unified and homogeneous part of the seismicity record (declustered dataset of 2051 earthquakes between January 1905 and May 2026) in the entire eastern Himalaya region by using the Gutenberg‐Richter relationship. A comprehensive study on the behaviour of natural seismicity encompassing the seismic gap regions is performed. The entire area is divided into square grids of size 0.2° × 0.2°, and after that, the b ‐value associated with each square grid is calculated. The results indicate that the cyclical fluctuations of the b ‐value characterise the ongoing stress build‐up and its subsequent release. The observed low b ‐value zones mark high‐stress asperities prone to large events, whereas high b ‐values reflect complex geology. It is observed that the b ‐values decrease with depth and correlate with underlying shear‐wave velocity. The inferred correlation of b ‐values with gravity anomalies is not uniform but tectonically controlled. A close comparison between b ‐values and different faulting styles reveals that the area with the highest b ‐values exhibits normal faulting. In contrast, low b ‐values are associated with thrust faulting. We believe that this unified multi‐parametric assessment offers critical insights into seismic hazard assessment by identifying high‐risk zones, which demand urgent attention.
- 21 September 2026
- Published by Wiley in Geological Journal
Understanding the Seismicity Pattern Across the Eastern Himalayan Region by Means of Spatiotemporal Variations in the Seismic b ‐Value
Himalayan earthquakes are triggered by the release of accumulated strain driven by tectonic forces. The different geological settings of the Himalayan Seismic belt contribute to the inhomogeneous seismicity profile of the region. In this study, we estimated the spatial and temporal variation of seismicity using a unified and homogeneous part of the seismicity record (declustered dataset of 2051 earthquakes between January 1905 and May 2026) in the entire eastern Himalaya region by using the Gutenberg‐Richter relationship. A comprehensive study on the behaviour of natural seismicity encompassing the seismic gap regions is performed. The entire area is divided into square grids of size 0.2° × 0.2°, and after that, the b ‐value associated with each square grid is calculated. The results indicate that the cyclical fluctuations of the b ‐value characterise the ongoing stress build‐up and its subsequent release. The observed low b ‐value zones mark high‐stress asperities prone to large events, whereas high b ‐values reflect complex geology. It is observed that the b ‐values decrease with depth and correlate with underlying shear‐wave velocity. The inferred correlation of b ‐values with gravity anomalies is not uniform but tectonically controlled. A close comparison between b ‐values and different faulting styles reveals that the area with the highest b ‐values exhibits normal faulting. In contrast, low b ‐values are associated with thrust faulting. We believe that this unified multi‐parametric assessment offers critical insights into seismic hazard assessment by identifying high‐risk zones, which demand urgent attention.
- 27 August 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (33) , 7139-7149
Electrically modulated optical transmittance of silver nanoparticles: effects of concentration, pH, and applied potential for sensing applications
Transient electro-optical response of AgNP solutions across different concentrations and pH under an external potential.
- 27 August 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (33) , 7139-7149
Electrically modulated optical transmittance of silver nanoparticles: effects of concentration, pH, and applied potential for sensing applications
Transient electro-optical response of AgNP solutions across different concentrations and pH under an external potential.
- 5 August 2026
- Published by Wiley in Journal of Biophotonics
- Vol. 19 (8)
Facile Optical Interrogation for Random Pulse Measurement: Characterization and Analysis of PPG Waveforms Using a Reflection‐Based Sensor
A compact reflection‐mode optical sensor was developed and evaluated for noninvasive pulse waveform measurement using photoplethysmography (PPG). The sensor integrates an infrared light‐emitting diode and photodetector, enabling real‐time acquisition of PPG signals from subjects with diverse ages and health conditions. Despite a limited sample size, the device demonstrated reliable detection of physiologically relevant differences in pulse waveforms. The average systolic amplitude was 105.06 mV, with a mean pulse width of 0.14 s and an augmentation index of 0.19. Notably, subjects with identified health issues showed a trend toward higher augmentation index values and reduced compliance in pulse waveform morphology, consistent with diminished vascular elasticity. These findings highlight the potential of the proposed approach for early cardiovascular screening and personalized health monitoring. Future work will focus on validating the sensor in larger cohorts and enhancing robustness for real‐world applications.
- 5 August 2026
- Published by Wiley in Journal of Biophotonics
- Vol. 19 (8)
Facile Optical Interrogation for Random Pulse Measurement: Characterization and Analysis of PPG Waveforms Using a Reflection‐Based Sensor
A compact reflection‐mode optical sensor was developed and evaluated for noninvasive pulse waveform measurement using photoplethysmography (PPG). The sensor integrates an infrared light‐emitting diode and photodetector, enabling real‐time acquisition of PPG signals from subjects with diverse ages and health conditions. Despite a limited sample size, the device demonstrated reliable detection of physiologically relevant differences in pulse waveforms. The average systolic amplitude was 105.06 mV, with a mean pulse width of 0.14 s and an augmentation index of 0.19. Notably, subjects with identified health issues showed a trend toward higher augmentation index values and reduced compliance in pulse waveform morphology, consistent with diminished vascular elasticity. These findings highlight the potential of the proposed approach for early cardiovascular screening and personalized health monitoring. Future work will focus on validating the sensor in larger cohorts and enhancing robustness for real‐world applications.
- Open Access
- 1 August 2026
- Published by Scientific Archives in Journal of Nanotechnology and Nanomaterials
- Vol. 7 (1) , 18-22
A Brief Note on Multifaceted Aspect of Functional Quantum Dots
Discovered in 1981, Quantum Dots (QDs) are semiconductor nanocrystals defined by quantum confinement, which allows for precise sizetuneable optoelectronic properties. Their brightness, photostability, and discrete energy levels have revolutionized fields from energy storage to optoelectronics. This brief note focuses on the transformative role of QDs as a multi-faceted entity. We underline the historical evolution of synthesis and surface functionalization techniques that enable advanced applications in imaging and biosensing. Despite their potential for application in domain such as precision medicine, challenges regarding cytotoxicity and biocompatibility remain significant hurdles. By exploring current research into safer design strategies and regulatory frameworks, this work outlines how integrating QDs with broader nanotechnologies will shape the future of clinical diagnostics and personalized therapy.
- 1 August 2026
- Published by Scientific Archives in Journal of Nanotechnology and Nanomaterials
- Vol. 7 (1) , 18-22
Open AccessA Brief Note on Multifaceted Aspect of Functional Quantum Dots
Discovered in 1981, Quantum Dots (QDs) are semiconductor nanocrystals defined by quantum confinement, which allows for precise sizetuneable optoelectronic properties. Their brightness, photostability, and discrete energy levels have revolutionized fields from energy storage to optoelectronics. This brief note focuses on the transformative role of QDs as a multi-faceted entity. We underline the historical evolution of synthesis and surface functionalization techniques that enable advanced applications in imaging and biosensing. Despite their potential for application in domain such as precision medicine, challenges regarding cytotoxicity and biocompatibility remain significant hurdles. By exploring current research into safer design strategies and regulatory frameworks, this work outlines how integrating QDs with broader nanotechnologies will shape the future of clinical diagnostics and personalized therapy.
- 18 June 2026
- Published by Springer Nature in Interactions
- Vol. 247 (1)
A DFT study on influence of solvent media on electronic, optical and vibrational properties of TiO2nanoparticle
- 18 June 2026
- Published by Springer Nature in Interactions
- Vol. 247 (1)
A DFT study on influence of solvent media on electronic, optical and vibrational properties of TiO2nanoparticle
- 30 May 2026
- Published by Elsevier in Ceramics International
- Vol. 52 (27) , 55683-55693
A promising application of semiconducting TiO2 nanoparticles towards detection of food colorants
- 30 May 2026
- Published by Elsevier in Ceramics International
- Vol. 52 (27) , 55683-55693
A promising application of semiconducting TiO2 nanoparticles towards detection of food colorants
- 25 May 2026
- Published by Elsevier in Ceramics International
- Vol. 52 (27) , 55649-55653
Semiconducting WS2 nanosheet functionalization on optical fiber for smart environmental sensing
- 25 May 2026
- Published by Elsevier in Ceramics International
- Vol. 52 (27) , 55649-55653
Semiconducting WS2 nanosheet functionalization on optical fiber for smart environmental sensing