Chuanmao Fan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chuanmao Fan has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
- Gang Yao
University of Missouri
2 shared publications
Latest Publications
- 28 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 57 (10) , 2556-2559
Correcting Optical-Axis Calculation in Polarization-Sensitive Optical Coherence Tomography
Polarization-sensitive optical coherence tomography (PSOCT) has found many applications in imaging birefringence tissue samples. Polarization-sensitive detection is often implemented by utilizing a circularly polarized incident light and detecting the two orthogonal horizontal- and vertical-polarized interference components. However, the obtained optical axes images were inappropriately represented as depth-dependent periodic maps in all reported studies. A detailed analysis confirmed that this misrepresentation was caused by the accumulation of optical retardation with depth. A simple method was proposed to numerically correct this optical-axis calculation. Experimental studies in tendon tissue demonstrated that this method can be applied to map the 2-D optical-axis distributions in enface PSOCT images.
- 28 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 57 (10) , 2556-2559
Correcting Optical-Axis Calculation in Polarization-Sensitive Optical Coherence Tomography
Polarization-sensitive optical coherence tomography (PSOCT) has found many applications in imaging birefringence tissue samples. Polarization-sensitive detection is often implemented by utilizing a circularly polarized incident light and detecting the two orthogonal horizontal- and vertical-polarized interference components. However, the obtained optical axes images were inappropriately represented as depth-dependent periodic maps in all reported studies. A detailed analysis confirmed that this misrepresentation was caused by the accumulation of optical retardation with depth. A simple method was proposed to numerically correct this optical-axis calculation. Experimental studies in tendon tissue demonstrated that this method can be applied to map the 2-D optical-axis distributions in enface PSOCT images.
- 24 March 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (7) , 7281-7287
Single camera spectral domain polarization-sensitive optical coherence tomography using offset B-scan modulation
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 24 March 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (7) , 7281-7287
Single camera spectral domain polarization-sensitive optical coherence tomography using offset B-scan modulation
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.