Charlotte Arnal
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Charlotte Arnal has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
B Besse
2 shared publicationsS Billaudel
2 shared publicationsV Ferré-Aubineau
2 shared publicationsB Mignotte
1 shared publicationBerangere Mignotte
<!--label omitted: 3-->Laboratoire de Virologie, UMR 7564 CNRS, Faculté de Pharmacie, Université Poincaré, 54001 Nancy Cedex,3 France
1 shared publicationBerthe Marie Imbert-Marcille
<!--label omitted: 2-->Université de Nantes EA1156, 44035 Nantes,2 and
1 shared publication
Latest Publications
- 1 January 1999
- Published by Elsevier in Journal of Virological Methods
- Vol. 77 (1) , 17-26
Comparison of seven RNA extraction methods on stool and shellfish samples prior to hepatitis A virus amplification
- 1 January 1999
- Published by Elsevier in Journal of Virological Methods
- Vol. 77 (1) , 17-26
Comparison of seven RNA extraction methods on stool and shellfish samples prior to hepatitis A virus amplification
- 1 January 1999
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 65 (1) , 322-326
Quantification of Hepatitis A Virus in Shellfish by Competitive Reverse Transcription-PCR with Coextraction of Standard RNA
To quantify hepatitis A virus (HAV) in experimentally contaminated mussels, we developed an internal standard RNA with a 7-nucleotide deletion for competitive reverse transcription (RT)-PCR. Deposited directly into the sample, this standard was used both as extraction control and as quantification tool. After coextraction and competitive RT-PCR, standard and wild-type products were detected by differential hybridization with specific probes and a DNA enzyme immunoassay. The quantifiable range with this reproducible method was 10 4 to 10 7 copies of HAV/gram or 400 to 10 6 50% tissue culture infective doses/ml.
- 1 January 1999
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 65 (1) , 322-326
Quantification of Hepatitis A Virus in Shellfish by Competitive Reverse Transcription-PCR with Coextraction of Standard RNA
To quantify hepatitis A virus (HAV) in experimentally contaminated mussels, we developed an internal standard RNA with a 7-nucleotide deletion for competitive reverse transcription (RT)-PCR. Deposited directly into the sample, this standard was used both as extraction control and as quantification tool. After coextraction and competitive RT-PCR, standard and wild-type products were detected by differential hybridization with specific probes and a DNA enzyme immunoassay. The quantifiable range with this reproducible method was 10 4 to 10 7 copies of HAV/gram or 400 to 10 6 50% tissue culture infective doses/ml.
- 1 March 1998
- Vol. 44 (3) , 298-302
Simplified reverse transcription polymerase chain reaction procedure with detection by microplate hybridization for routine screening of hepatitis A virus.
Reverse transcription polymerase chain reaction, using either nested or seminested primers, is used extensively for the detection of viruses in small quantities. However, existing methods are prone to false positive reactions. We report here an improved polymerase chain reaction technique based on the use of longer primers (39 nucleotides) with single-step amplification, applied to the detection of hepatitis A in low quantities. While the sensitivity of this technique (10 x the 50% tissue culture infective dose) is equivalent to that of existing methods, it is a simpler procedure, less time consuming, and less susceptible to contamination and therefore provides a more reliable tool for routine diagnosis. Finally, the development of a DNA enzyme immunoassay detection technique and the complete automation of the procedure allow a large number of samples to be processed in clinical laboratories.
- 1 March 1998
- Vol. 44 (3) , 298-302
Simplified reverse transcription polymerase chain reaction procedure with detection by microplate hybridization for routine screening of hepatitis A virus.
Reverse transcription polymerase chain reaction, using either nested or seminested primers, is used extensively for the detection of viruses in small quantities. However, existing methods are prone to false positive reactions. We report here an improved polymerase chain reaction technique based on the use of longer primers (39 nucleotides) with single-step amplification, applied to the detection of hepatitis A in low quantities. While the sensitivity of this technique (10 x the 50% tissue culture infective dose) is equivalent to that of existing methods, it is a simpler procedure, less time consuming, and less susceptible to contamination and therefore provides a more reliable tool for routine diagnosis. Finally, the development of a DNA enzyme immunoassay detection technique and the complete automation of the procedure allow a large number of samples to be processed in clinical laboratories.