Razieh Alemi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Razieh Alemi has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Alexandre Lehmann
McGill Univ, Fac Med, Dept Otolaryngol, Montreal, PQ, Canada
3 shared publications- Alexander G. Bien
Department of Otolaryngology – Head and Neck Surgery The University of Oklahoma Health Sciences Center Oklahoma City Oklahoma USA
1 shared publication - Alexandre Lehmann
McGill University Faculty of Medicine
1 shared publication Caleb Wilson
Department of Otolaryngology-Head & Neck Surgery, University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA
1 shared publicationErin Schafer
Department of Audiology & Speech-Language Pathology, University of North Texas, Denton, TX, USA
1 shared publicationJace Wolfe
Oberkotter Foundation, Oklahoma City, OK, USA
1 shared publication
Latest Publications
- Open Access
- 17 November 2023
- Published by SAGE Publications in Perceptual and Motor Skills
- Vol. 131 (1) , 74-105
Motor Processing in Children With Cochlear Implants as Assessed by Functional Near-Infrared Spectroscopy
Auditory-motor and visual-motor networks are often coupled in daily activities, such as when listening to music and dancing; but these networks are known to be highly malleable as a function of sensory input. Thus, congenital deafness may modify neural activities within the connections between the motor, auditory, and visual cortices. Here, we investigated whether the cortical responses of children with cochlear implants (CI) to a simple and repetitive motor task would differ from that of children with typical hearing (TH) and we sought to understand whether this response related to their language development. Participants were 75 school-aged children, including 50 with CI (with varying language abilities) and 25 controls with TH. We used functional near-infrared spectroscopy (fNIRS) to record cortical responses over the whole brain, as children squeezed the back triggers of a joystick that vibrated or not with the squeeze. Motor cortex activity was reflected by an increase in oxygenated hemoglobin concentration (HbO) and a decrease in deoxygenated hemoglobin concentration (HbR) in all children, irrespective of their hearing status. Unexpectedly, the visual cortex (supposedly an irrelevant region) was deactivated in this task, particularly for children with CI who had good language skills when compared to those with CI who had language delays. Presence or absence of vibrotactile feedback made no difference in cortical activation. These findings support the potential of fNIRS to examine cognitive functions related to language in children with CI.
- 17 November 2023
- Published by SAGE Publications in Perceptual and Motor Skills
- Vol. 131 (1) , 74-105
Open AccessMotor Processing in Children With Cochlear Implants as Assessed by Functional Near-Infrared Spectroscopy
Auditory-motor and visual-motor networks are often coupled in daily activities, such as when listening to music and dancing; but these networks are known to be highly malleable as a function of sensory input. Thus, congenital deafness may modify neural activities within the connections between the motor, auditory, and visual cortices. Here, we investigated whether the cortical responses of children with cochlear implants (CI) to a simple and repetitive motor task would differ from that of children with typical hearing (TH) and we sought to understand whether this response related to their language development. Participants were 75 school-aged children, including 50 with CI (with varying language abilities) and 25 controls with TH. We used functional near-infrared spectroscopy (fNIRS) to record cortical responses over the whole brain, as children squeezed the back triggers of a joystick that vibrated or not with the squeeze. Motor cortex activity was reflected by an increase in oxygenated hemoglobin concentration (HbO) and a decrease in deoxygenated hemoglobin concentration (HbR) in all children, irrespective of their hearing status. Unexpectedly, the visual cortex (supposedly an irrelevant region) was deactivated in this task, particularly for children with CI who had good language skills when compared to those with CI who had language delays. Presence or absence of vibrotactile feedback made no difference in cortical activation. These findings support the potential of fNIRS to examine cognitive functions related to language in children with CI.
- 1 May 2023
- Published by Elsevier in Journal of Voice
- Vol. 37 (3) , 466.e1-466.e15
Changes in Spoken and Sung Productions Following Adaptation to Pitch-shifted Auditory Feedback
- 1 May 2023
- Published by Elsevier in Journal of Voice
- Vol. 37 (3) , 466.e1-466.e15
Changes in Spoken and Sung Productions Following Adaptation to Pitch-shifted Auditory Feedback
- 29 June 2021
- Published by Springer Nature in Brain Topography
- Vol. 34 (5) , 664-680
Free-Field Cortical Steady-State Evoked Potentials in Cochlear Implant Users
Auditory steady-state evoked potentials (SS-EPs) are phase-locked neural responses to periodic stimuli, believed to reflect specific neural generators. As an objective measure, steady-state responses have been used in different clinical settings, including measuring hearing thresholds of normal and hearing-impaired subjects. Recent studies are in favor of recording these responses as a part of the cochlear implant (CI) device-fitting procedure. Considering these potential benefits, the goals of the present study were to assess the feasibility of recording free-field SS-EPs in CI users and to compare their characteristics between CI users and controls. By taking advantage of a recently developed dual-frequency tagging method, we attempted to record subcortical and cortical SS-EPs from adult CI users and controls and measured reliable subcortical and cortical SS-EPs in the control group. Independent component analysis (ICA) was used to remove CI stimulation artifacts, yet subcortical responses of several CIs were heavily contaminated by these artifacts. Consequently, only cortical SS-EPs were compared between groups, which were found to be larger in the controls. The lower cortical SS-EPs’ amplitude in CI users might indicate a reduction in neural synchrony evoked by the modulation rate of the auditory input across different neural assemblies in the auditory pathway. The brain topographies of cortical auditory SS-EPs, the time course of cortical responses, and the reconstructed cortical maps were highly similar between groups, confirming their neural origin and possibility to obtain such responses also in CI recipients. As for subcortical SS-EPs, our results highlight a need for sophisticated denoising algorithms to pinpoint and remove artifactual components from the biological response.
- 29 June 2021
- Published by Springer Nature in Brain Topography
- Vol. 34 (5) , 664-680
Free-Field Cortical Steady-State Evoked Potentials in Cochlear Implant Users
Auditory steady-state evoked potentials (SS-EPs) are phase-locked neural responses to periodic stimuli, believed to reflect specific neural generators. As an objective measure, steady-state responses have been used in different clinical settings, including measuring hearing thresholds of normal and hearing-impaired subjects. Recent studies are in favor of recording these responses as a part of the cochlear implant (CI) device-fitting procedure. Considering these potential benefits, the goals of the present study were to assess the feasibility of recording free-field SS-EPs in CI users and to compare their characteristics between CI users and controls. By taking advantage of a recently developed dual-frequency tagging method, we attempted to record subcortical and cortical SS-EPs from adult CI users and controls and measured reliable subcortical and cortical SS-EPs in the control group. Independent component analysis (ICA) was used to remove CI stimulation artifacts, yet subcortical responses of several CIs were heavily contaminated by these artifacts. Consequently, only cortical SS-EPs were compared between groups, which were found to be larger in the controls. The lower cortical SS-EPs’ amplitude in CI users might indicate a reduction in neural synchrony evoked by the modulation rate of the auditory input across different neural assemblies in the auditory pathway. The brain topographies of cortical auditory SS-EPs, the time course of cortical responses, and the reconstructed cortical maps were highly similar between groups, confirming their neural origin and possibility to obtain such responses also in CI recipients. As for subcortical SS-EPs, our results highlight a need for sophisticated denoising algorithms to pinpoint and remove artifactual components from the biological response.
- Open Access
- 8 October 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-20
Adaptation to pitch-altered feedback is independent of one’s own voice pitch sensitivity
Monitoring voice pitch is a fine-tuned process in daily conversations as conveying accurately the linguistic and affective cues in a given utterance depends on the precise control of phonation and intonation. This monitoring is thought to depend on whether the error is treated as self-generated or externally-generated, resulting in either a correction or inflation of errors. The present study reports on two separate paradigms of adaptation to altered feedback to explore whether participants could behave in a more cohesive manner once the error is of comparable size perceptually. The vocal behavior of normal-hearing and fluent speakers was recorded in response to a personalized size of pitch shift versus a non-specific size, one semitone. The personalized size of shift was determined based on the just-noticeable difference in fundamental frequency (F0) of each participant’s voice. Here we show that both tasks successfully demonstrated opposing responses to a constant and predictable F0 perturbation (on from the production onset) but these effects barely carried over once the feedback was back to normal, depicting a pattern that bears some resemblance to compensatory responses. Experiencing a F0 shift that is perceived as self-generated (because it was precisely just-noticeable) is not enough to force speakers to behave more consistently and more homogeneously in an opposing manner. On the contrary, our results suggest that the type of the response as well as the magnitude of the response do not depend in any trivial way on the sensitivity of participants to their own voice pitch. Based on this finding, we speculate that error correction could possibly occur even with a bionic ear, typically even when F0 cues are too subtle for cochlear implant users to detect accurately.
- 8 October 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-20
Open AccessAdaptation to pitch-altered feedback is independent of one’s own voice pitch sensitivity
Monitoring voice pitch is a fine-tuned process in daily conversations as conveying accurately the linguistic and affective cues in a given utterance depends on the precise control of phonation and intonation. This monitoring is thought to depend on whether the error is treated as self-generated or externally-generated, resulting in either a correction or inflation of errors. The present study reports on two separate paradigms of adaptation to altered feedback to explore whether participants could behave in a more cohesive manner once the error is of comparable size perceptually. The vocal behavior of normal-hearing and fluent speakers was recorded in response to a personalized size of pitch shift versus a non-specific size, one semitone. The personalized size of shift was determined based on the just-noticeable difference in fundamental frequency (F0) of each participant’s voice. Here we show that both tasks successfully demonstrated opposing responses to a constant and predictable F0 perturbation (on from the production onset) but these effects barely carried over once the feedback was back to normal, depicting a pattern that bears some resemblance to compensatory responses. Experiencing a F0 shift that is perceived as self-generated (because it was precisely just-noticeable) is not enough to force speakers to behave more consistently and more homogeneously in an opposing manner. On the contrary, our results suggest that the type of the response as well as the magnitude of the response do not depend in any trivial way on the sensitivity of participants to their own voice pitch. Based on this finding, we speculate that error correction could possibly occur even with a bionic ear, typically even when F0 cues are too subtle for cochlear implant users to detect accurately.
- 1 May 2019
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 30 (5) , 396-405
Middle Latency Responses to Optimized Chirps in Adult Cochlear Implant Users
Background:Cochlear implant (CI) outcomes can be assessed using objective measures that reflect the integrity of the auditory pathway. One such measure is the middle latency response (MLR), which can provide valuable information for clinicians.Purpose:Traditional stimuli for evoking MLRs, that is, clicks or tone bursts, do not stimulate all parts of the cochlea simultaneously, whereas chirp stimuli compensate for the cochlear neural delay and, therefore, produce more synchronous responses from the different neural elements of the cochlea. The purpose of the present study was to determine whether chirp stimuli can elicit reliable MLRs in CI users and whether those responses correlate with clinical outcomes and with deprivation-related factors.Research Design:We presented 2,000 free-field optimized chirp stimuli to CI and control participants while their electroencephalography (EEG) was being recorded.Study Sample:Twenty-four adult CI users and 24 matched normal-hearing (NH) individuals (age range from 18 to 63 years) participated in this study.Data Collections and Analysis:The EEG was recorded from 64 active electrodes placed on the scalp. EEG signals were processed using EEGLAB and ERPLAB toolboxes. We characterized the latencies and amplitudes of the different MLR components in both groups.Results:Chirp stimuli reliably evoked qualitatively similar MLRs across all NH and CI participants with a couple of differences observed between the NH and CI group. Among the different MLR components, the Na latency was significantly shorter for the CI group. A significant amplitude difference was also found between groups for the Pa‐Nb complex, with higher amplitudes observed in the NH group. Finally, there were no significant correlations between MLR latencies (or amplitudes) and clinical outcomes or deprivation-related measures.Conclusions:Free-field‐presented optimized chirp stimuli were shown to evoke measurable and reliable MLRs in CI users. In this experiment, the MLR morphology in CI users was similar to those observed in NH participants. Even though we did not replicate here a significant relationship between MLR and speech perception measures, we were able to successfully collect acoustically evoked MLRs, which could constitute an important supplemental measure to the standard behavioral tests presently being used in postoperative clinical evaluation settings.
- 1 May 2019
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 30 (5) , 396-405
Middle Latency Responses to Optimized Chirps in Adult Cochlear Implant Users
Background:Cochlear implant (CI) outcomes can be assessed using objective measures that reflect the integrity of the auditory pathway. One such measure is the middle latency response (MLR), which can provide valuable information for clinicians.Purpose:Traditional stimuli for evoking MLRs, that is, clicks or tone bursts, do not stimulate all parts of the cochlea simultaneously, whereas chirp stimuli compensate for the cochlear neural delay and, therefore, produce more synchronous responses from the different neural elements of the cochlea. The purpose of the present study was to determine whether chirp stimuli can elicit reliable MLRs in CI users and whether those responses correlate with clinical outcomes and with deprivation-related factors.Research Design:We presented 2,000 free-field optimized chirp stimuli to CI and control participants while their electroencephalography (EEG) was being recorded.Study Sample:Twenty-four adult CI users and 24 matched normal-hearing (NH) individuals (age range from 18 to 63 years) participated in this study.Data Collections and Analysis:The EEG was recorded from 64 active electrodes placed on the scalp. EEG signals were processed using EEGLAB and ERPLAB toolboxes. We characterized the latencies and amplitudes of the different MLR components in both groups.Results:Chirp stimuli reliably evoked qualitatively similar MLRs across all NH and CI participants with a couple of differences observed between the NH and CI group. Among the different MLR components, the Na latency was significantly shorter for the CI group. A significant amplitude difference was also found between groups for the Pa‐Nb complex, with higher amplitudes observed in the NH group. Finally, there were no significant correlations between MLR latencies (or amplitudes) and clinical outcomes or deprivation-related measures.Conclusions:Free-field‐presented optimized chirp stimuli were shown to evoke measurable and reliable MLRs in CI users. In this experiment, the MLR morphology in CI users was similar to those observed in NH participants. Even though we did not replicate here a significant relationship between MLR and speech perception measures, we were able to successfully collect acoustically evoked MLRs, which could constitute an important supplemental measure to the standard behavioral tests presently being used in postoperative clinical evaluation settings.