Hesham M. Fekry
Hesham M. Fekry has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Azza Ahmed ElDesouky
Port Said University
2 shared publications - Abdulwasa Bakr Barnawi
Department of Electrical Engineering, College of Engineering, King Khalid University, Abha, Saudi Arabia
1 shared publication - Ahmed Ali Salem
Suez Canal University
1 shared publication - Ahmed Hussain Elmetwaly
Electrical Power and Machines Engineering Department, The Higher Institute of Engineering at El-Shorouk City, El-Shorouk Academy, Cairo, Egypt
1 shared publication Ahmed M. Kassem
Faculty of Engineering, Sohag University, Sohag, Egypt
1 shared publication- Almoataz Youssef Abdelaziz
Electrical Power and Machines Engineering Department, Faculty of Engineering, Ain Shams University, Cairo, Egypt
1 shared publication
Latest Publications
- Open Access
- 1 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 99822-99835
Improving Power Quality Problems of Isolated MG Based on ANN Under Different Operating Conditions Through PMS and ASSC Integration
Microgrid (MG) technologies assist the power grid in evolving to become more efficient, less polluting, and more resilient by addressing the requirements of energy users. However, several technological issues arise as a result of the unpredictability and difficulty in estimating the efficacy and regulation of the many renewable energy resources (RERs) incorporated in MGs. Two of the most significant of these issues are maintaining system stability and power quality, which necessitate to get better the performance of the MGs. The most difficult challenge, system stability, can be achieved with successful Power Management System (PMS). This paper proposes an effective PMS for an AC MG equipped with a diesel generator (DG), a permanent magnet wind generator (PMWG), and a solar photovoltaic (PV) panel Based on an adaptable Artificial Neural Network (ANN). The ANN weights are properly tuned via the Enhanced Bald Eagle Search (EBES) optimization algorithm to produce a stable system during the whole training period, achieve MG energy balance, reduce the usage of fossil fuel DG and maintain MG voltage stability. In addition, for keeping power quality, an adaptive series shunt compensator (ASSC) is described in this work, along with a developed integrative PID controller, where the latter’s controller gains are ideally set utilizing the EBES optimization algorithm to perform adaptably with self-tuning when the operational circumstances of an MG change. various cases are displayed to test the strong of offered ASSC on harmonic mitigation, dynamic voltage stabilization, reactive power control and power factor correction. Moreover, comprehensive case study based on realistic on-site location for Zafarana region, Suez Gulf region of Egypt is proposed. Taking into account The changing nature of weather-related renewable energy, actual loads states and transient faults.
- 1 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 99822-99835
Open AccessImproving Power Quality Problems of Isolated MG Based on ANN Under Different Operating Conditions Through PMS and ASSC Integration
Microgrid (MG) technologies assist the power grid in evolving to become more efficient, less polluting, and more resilient by addressing the requirements of energy users. However, several technological issues arise as a result of the unpredictability and difficulty in estimating the efficacy and regulation of the many renewable energy resources (RERs) incorporated in MGs. Two of the most significant of these issues are maintaining system stability and power quality, which necessitate to get better the performance of the MGs. The most difficult challenge, system stability, can be achieved with successful Power Management System (PMS). This paper proposes an effective PMS for an AC MG equipped with a diesel generator (DG), a permanent magnet wind generator (PMWG), and a solar photovoltaic (PV) panel Based on an adaptable Artificial Neural Network (ANN). The ANN weights are properly tuned via the Enhanced Bald Eagle Search (EBES) optimization algorithm to produce a stable system during the whole training period, achieve MG energy balance, reduce the usage of fossil fuel DG and maintain MG voltage stability. In addition, for keeping power quality, an adaptive series shunt compensator (ASSC) is described in this work, along with a developed integrative PID controller, where the latter’s controller gains are ideally set utilizing the EBES optimization algorithm to perform adaptably with self-tuning when the operational circumstances of an MG change. various cases are displayed to test the strong of offered ASSC on harmonic mitigation, dynamic voltage stabilization, reactive power control and power factor correction. Moreover, comprehensive case study based on realistic on-site location for Zafarana region, Suez Gulf region of Egypt is proposed. Taking into account The changing nature of weather-related renewable energy, actual loads states and transient faults.
- Open Access
- 21 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 192087-192100
Power Management Strategy Based on Adaptive Neuro Fuzzy Inference System for AC Microgrid
Microgrids (MGs) have been widely implemented as they increase the efficiency and resiliency of electrical networks. However, the uncertain nature of renewable energy resources (RERs) integrated into the MGs usually results in different technical problems. System stability, the most challenging problem, can be achieved via a robust power management strategy (PMS) of the MG. This paper introduces a PMS based on adaptive neuro fuzzy inference system (ANFIS) for AC MG consisting of a diesel generator (DG), a double fed induction generator (DFIG) driven by a wind turbine (WT) and a solar photovoltaic (PV) panel. The proposed strategy aims to achieve MG power balance, decrease DG fossil fuel to minimum consumption, keep the MG voltage stability and finally tracking the maximum power point (MPP) of each RER. Metaheuristic optimization techniques; including genetic algorithm (GA) and particle swarm optimization (PSO), are employed to train the ANFIS to accomplish the desired objectives and fulfill the generation/consumption balance. The proposed AC MG with the PMS is simulated by the MATLAB/Simulink software in order to analyze the system performance under different climatic conditions. The simulation results under symmetrical and asymmetrical electrical faults validated the effectiveness of the proposed strategy.
- 21 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 192087-192100
Open AccessPower Management Strategy Based on Adaptive Neuro Fuzzy Inference System for AC Microgrid
Microgrids (MGs) have been widely implemented as they increase the efficiency and resiliency of electrical networks. However, the uncertain nature of renewable energy resources (RERs) integrated into the MGs usually results in different technical problems. System stability, the most challenging problem, can be achieved via a robust power management strategy (PMS) of the MG. This paper introduces a PMS based on adaptive neuro fuzzy inference system (ANFIS) for AC MG consisting of a diesel generator (DG), a double fed induction generator (DFIG) driven by a wind turbine (WT) and a solar photovoltaic (PV) panel. The proposed strategy aims to achieve MG power balance, decrease DG fossil fuel to minimum consumption, keep the MG voltage stability and finally tracking the maximum power point (MPP) of each RER. Metaheuristic optimization techniques; including genetic algorithm (GA) and particle swarm optimization (PSO), are employed to train the ANFIS to accomplish the desired objectives and fulfill the generation/consumption balance. The proposed AC MG with the PMS is simulated by the MATLAB/Simulink software in order to analyze the system performance under different climatic conditions. The simulation results under symmetrical and asymmetrical electrical faults validated the effectiveness of the proposed strategy.