MSMalairajan Singanan

Malairajan Singanan

*This is an algorithmically generated author record based on publicly available information.

Malairajan Singanan has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Manoharan E K

    Department of Chemistry, Presidency College (Autonomous), Chennai-600005, Tamil Nadu, India

    2 shared publications
  • Alemayehu Abebaw

    Departmentof Applied Chemistry, Ambo College – Jimma University, P.O. Box 19, Ambo Town, Western Shoa, Ethiopia

    1 shared publication
  • Singanan Vinodhini

    No. 44, Rettai Kuli Street, Tondiyar Pet, Chennai –600 081, Tamilnadu, India

    1 shared publication
  • Sundaram R

    Department of Chemistry, P.T. Lee C.N. Polytechnic College, Chennai-600007, Tamil Nadu, India

    1 shared publication

Latest Publications

  • Open Access

    Investigation on the removal of bivalent cadmium ions from aqueous solution and treatment of industrial wastewater using new alumina interfaced biocarbon

    by Sundaram R, Singanan M

    The presence of heavy metals in water and wastewater is becoming a severe environmental and public health concern. It may contribute variety of adverse environmental and human health effects due to their acute and chronic exposure through air, water and food chain. They are released into the aquatic environment from many industrial activities. The present research paper deals with the adsorption capacity of the biocarbon material produced from the leaves of Lawsonia inermis plant. The biocarbon was prepared by the H2SO4 activation process. The adsorption capacity of the biocarbon was evaluated by considering the effect of various parameters such as pH of the solution, biocarbon dose, contact time, and initial metal ions concentration and to optimize the conditions for maximum adsorption. The metal ion uptake capacity of the biocarbon was tested in the stimulated wastewater containing bivalent cadmium ions. The maximum uptake of 97.85% of the Cd (II) metal ions was observed at the equilibrium time of 3.0 hours at a dose of 3.0 g and at the pH of 4.5 in the stimulated wastewater. In the real sample analysis, electroplating industry wastewater is used for the removal of cadmium (II) ions. The results indicate that 95.16% of ions were effectively removed at the same experimental conditions. It is also further noted that the metal sorption capability of the adsorbent is higher with rising concentration of metal ions in the solution. The percentage of adsorption of the metal ions was also significantly increased with rise of temperature of the wastewater.

  • Open Access

    Corrosion resistance studies of aluminium 7075 / SiC composites materials in an acidic environment

    by Manoharan E K, Singanan M

    The aluminium and silicon carbide-based composite (Al-SiC) material was prepared using commercially available analytical grade Al7075 alloy and SiC. Here the silicon carbide is used as reinforcement particles in the composites. The metal composites were developed using liquid melt techniques (Vortex method). The reinforcement material is introduced in different weight fractions in the range of 0 to 10% in this process. These Al-SiC specimens were used for assessment of its corrosion properties. The acid corrosion experiments were carried out at room temperature (30 ±1oC). The corrosion characteristics were estimated using the conventional weight loss method according to the procedure of ASTM G69-80. The composites performance was evaluated using microstructural analysis and the corrosion resistance tendency in different acidic environmental conditions. The SEM micrographs picture reveals that reinforcement particle was distributed uniformly. The corrosion test was conducted in HCl medium from 0.25N, 0.5N, 1M and 1.5 M respectively. The Al-SiC specimens were dipped in different HCl medium for four days in six experimental baths. Specimens were taken out from each test medium for every 24 hours and tested for its corrosion characteristics. It is observed that the corrosion rate in all HCl medium decreases with an increase in exposure time. This is due to the passivation of the Al-SiC surface induced by aluminium. It was observed that at the 10 w/w % of the aluminium metal matrix composite have higher corrosion resistance than the base alloy.

  • Open Access

    Studies on the corrosion resistance of Al7075 / SiC metal matrix composites in an alkaline environment

    by Manoharan E K, Singanan M

    Metal matrix composites are of interest every day due to their lightweight, improved mechanical properties, and increased corrosion resistance. They are used in the aeronautical, aerospace, marine, and automotive industries. A variety of methods can estimate Their corrosion properties. The open-circuit potential studies are also a tool for evaluating the corrosion of composite materials. This research paper focuses on studying open circuit potential determination of the aluminium 7075 alloys reinforced with silicon carbide particulate in differently concentrated sodium hydroxide solutions. The composite materials were prepared by adding 2, 4, 6, 8 and 10 weight percentages of silicon carbide to the aluminium base metal liquid melt metallurgy technique (Vortex method). The silicon carbide used as reinforcement in size range of 50 – 80 µm, which is commercially available. The SiC particulates material is had been preheated to 400°C and introduced into the liquid melt of Al7075 at a rate of 100 g/m, under constant agitating condition using a mechanical stirrer system for 3 to 4 minutes. Rectangular specimens of 2 cm length, 1cm width and 1 mm thickness were used for the experiments. 1sq.cm area of the specimens was exposed to sodium hydroxide medium. Open circuit potential experiments test was conducted using a multimeter and calomel electrode system. The potential observed for 2, 4, 6, 8 and 10% silicon carbide composites were less than the potential of matrix alloy for a range of 30 hours.


  • Open Access

    REMOVAL OF LEAD IONS FROM INDUSTRIAL WASTE WATER BY USING BIOMATERIALS – A NOVEL METHOD

    by Malairajan Singanan, Alemayehu Abebaw, Singanan Vinodhini

    A simple cost effective and eco-friendly method for the remediation of lead from industrial wastewater has been investigated. A novel biomaterial, Tridax procumbens (Asteraceae) a medicinal plant, was used for the removal of lead ions from synthetic wastewater and the method was also applied for real sample analysis. The operational pH of the experimental solution was fixed as 4.5. The optimum amount of bioadsorbent was 3.5 g. The Pb(II) ions removal efficiency of the raw bioadsorbent was also determined. The removal efficiency of the activated carbon of the bioadsorbent was excellent. 98 % removal of Pb(II) ions was achieved at the dose rate of 3.5 g. The optimum contact time was estimated to be 160 minutes. KEY WORDS: Removal of lead ions, Industrial wastewater, Biomaterial, Tridax procumbens (Asteraceae) Bull. Chem. Soc. Ethiop. 2005, 19(2), 289-294.