Marco Femia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marco Femia has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Ruggero Vercelli
Interventional Radiology Unit, ASST Santi Paolo Carlo, 20122 Milan, Italy
3 shared publications - Francesco Giurazza
Vascular and Interventional Radiology Department, Cardarelli Hospital, Naples, Italy
2 shared publications - Maurizio Cariati
Department of Radiology, ASST Santi Paolo e Carlo, San Carlo Borromeo Hospital, Milan, Italy
2 shared publications - Andrea Discalzi
Department of Diagnostic Imaging and Interventional Radiology, Interventional Radiology Unit, AOU Città della Salute e della Scienza di Torino, Turin, Italy
1 shared publication - Anna Rita Scrofani
Emergency and Interventional Radiology, Department of Diagnostic Imaging, Oncologic Radiotherapy and Hematology, Fondazione Policlinico Universitario Agostino Gemelli IRCCS , Roma 00168
1 shared publication - Antonio Basile
Radiology Unit 1, Department of Medical Surgical Sciences and Advanced Technologies “GF Ingrassia”, University Hospital Policlinico “G. Rodolico-San Marco”, University of Catania, 95123 Catania, Italy
1 shared publication
Latest Publications
- Open Access
- 3 September 2025
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 15 (9) , 420
Real-World Outcomes of Splenic Artery Embolization in Blunt Splenic Trauma: Insights from an Italian Multicenter Cohort
Background: Splenic artery embolization (SAE) has emerged as a key adjunct to non-operative management (NOM) in hemodynamically stable patients with blunt splenic trauma, yet variability in its application persists across centers. Objectives: The aim was to evaluate real-life clinical practices, techniques, and outcomes of SAE in blunt splenic trauma across multiple Italian trauma centers. Materials and Methods: This retrospective multicenter study analyzed data from 281 patients undergoing emergency SAE for blunt splenic trauma between January 2019 and December 2021. Demographics, imaging findings, embolization techniques, complications, and outcomes were collected and analyzed. Multivariate logistic regression was used to assess predictors of splenectomy. Results: The technical success rate was 100%, with a 9.6% rate of post-embolization splenectomy and a complication rate of 24.9% (including 5.7% splenic infarction and 3.2% rebleeding). Embolization was performed proximally (46.6%), distally (28.8%), or with a combined approach (24.6%). No significant correlation was found between embolization technique and splenectomy rate. Patients with AAST grade III injuries benefited from SAE with high technical success and low failure rates. Notably, 14.2% of patients underwent angiography despite negative CT, with a splenectomy rate of 10% in this subgroup. Multivariate analysis identified no independent predictors of splenectomy. Conclusions: SAE is a reliable and effective tool in the management of blunt splenic trauma, achieving high splenic salvage rates even in selected grade III injuries and CT-negative patients. In an era of precision medicine, interventional radiology should be regarded as a distinct and specific treatment modality, comparable to surgery, rather than being merely included within non-operative management (NOM).
- 3 September 2025
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 15 (9) , 420
Open AccessReal-World Outcomes of Splenic Artery Embolization in Blunt Splenic Trauma: Insights from an Italian Multicenter Cohort
Background: Splenic artery embolization (SAE) has emerged as a key adjunct to non-operative management (NOM) in hemodynamically stable patients with blunt splenic trauma, yet variability in its application persists across centers. Objectives: The aim was to evaluate real-life clinical practices, techniques, and outcomes of SAE in blunt splenic trauma across multiple Italian trauma centers. Materials and Methods: This retrospective multicenter study analyzed data from 281 patients undergoing emergency SAE for blunt splenic trauma between January 2019 and December 2021. Demographics, imaging findings, embolization techniques, complications, and outcomes were collected and analyzed. Multivariate logistic regression was used to assess predictors of splenectomy. Results: The technical success rate was 100%, with a 9.6% rate of post-embolization splenectomy and a complication rate of 24.9% (including 5.7% splenic infarction and 3.2% rebleeding). Embolization was performed proximally (46.6%), distally (28.8%), or with a combined approach (24.6%). No significant correlation was found between embolization technique and splenectomy rate. Patients with AAST grade III injuries benefited from SAE with high technical success and low failure rates. Notably, 14.2% of patients underwent angiography despite negative CT, with a splenectomy rate of 10% in this subgroup. Multivariate analysis identified no independent predictors of splenectomy. Conclusions: SAE is a reliable and effective tool in the management of blunt splenic trauma, achieving high splenic salvage rates even in selected grade III injuries and CT-negative patients. In an era of precision medicine, interventional radiology should be regarded as a distinct and specific treatment modality, comparable to surgery, rather than being merely included within non-operative management (NOM).
- Open Access
- 26 June 2024
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 14 (7) , 686
Genicular Artery Embolization: A New Tool for the Management of Refractory Osteoarthritis-Related Knee Pain
Osteoarthritis (OA) of the knee is a prevalent cause of chronic pain and disability, particularly affecting women. While traditionally attributed to chronic wear and tear, recent evidence highlights multifactorial pathogenesis involving low-grade inflammation and neoangiogenesis. Current therapeutic options include physical therapy, pharmacotherapy, and total knee arthroplasty (TKA). However, a subset of patients remain symptomatic despite conservative measures, necessitating the development of minimally invasive interventions. Genicular artery embolization (GAE) emerges as a promising option, targeting neovascularization and inflammatory processes in OA. This paper reviews the pathophysiological basis, patient selection criteria, procedural details, and outcomes of GAE. Notably, GAE demonstrates efficacy in relieving knee pain and improving function in patients refractory to conventional therapy. While further research is warranted to elucidate its long-term outcomes and compare it with existing modalities, GAE represents a novel approach in the management of symptomatic knee OA, potentially delaying or obviating the need for surgical intervention. Here, we synthesize the relevant literature, technical details of the procedure, and future perspectives. Moreover, the success of GAE prompts the exploration of transarterial embolization in other musculoskeletal conditions, underscoring the evolving role of interventional radiology in personalized pain management strategies.
- 26 June 2024
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 14 (7) , 686
Open AccessGenicular Artery Embolization: A New Tool for the Management of Refractory Osteoarthritis-Related Knee Pain
Osteoarthritis (OA) of the knee is a prevalent cause of chronic pain and disability, particularly affecting women. While traditionally attributed to chronic wear and tear, recent evidence highlights multifactorial pathogenesis involving low-grade inflammation and neoangiogenesis. Current therapeutic options include physical therapy, pharmacotherapy, and total knee arthroplasty (TKA). However, a subset of patients remain symptomatic despite conservative measures, necessitating the development of minimally invasive interventions. Genicular artery embolization (GAE) emerges as a promising option, targeting neovascularization and inflammatory processes in OA. This paper reviews the pathophysiological basis, patient selection criteria, procedural details, and outcomes of GAE. Notably, GAE demonstrates efficacy in relieving knee pain and improving function in patients refractory to conventional therapy. While further research is warranted to elucidate its long-term outcomes and compare it with existing modalities, GAE represents a novel approach in the management of symptomatic knee OA, potentially delaying or obviating the need for surgical intervention. Here, we synthesize the relevant literature, technical details of the procedure, and future perspectives. Moreover, the success of GAE prompts the exploration of transarterial embolization in other musculoskeletal conditions, underscoring the evolving role of interventional radiology in personalized pain management strategies.
- 30 March 2023
- Published by Springer Nature
- p. 79-85
Radioprotection
- Open Access
- 22 October 2020
- Published by Springer Nature in Internal and Emergency Medicine
- Vol. 16 (3) , 749-756
The role of lung ultrasound as a frontline diagnostic tool in the era of COVID-19 outbreak
The diffusion of the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) worldwide prompted the World Health Organization to declare the status of pandemic. The molecular diagnosis of SARS-CoV-2 infection is based on the detection of viral RNA on different biological specimens. Unfortunately, the test may require several hours to be performed. In the present study, we evaluated the diagnostic accuracy of lung point-of-care ultrasound (POCUS) for SARS-CoV-2 pneumonia in a cohort of symptomatic patients admitted to one emergency department (ED) in a high-prevalence setting. This retrospective study enrolled all patients who visited one ED with suspected respiratory infection in March 2020. All the patients were tested (usually twice if the first was negative) for SARS-CoV-2 on ED admission. The reference standard was considered positive if at least one specimen was positive. If all the specimens tested negative, the reference was considered negative. Diagnostic accuracy was evaluated using sensitivity, specificity, and positive and negative predictive value. Of the 444 symptomatic patients who were admitted to the ED in the study period, the result of the lung POCUS test was available for 384 (86.5%). The sensitivity of the test was 92.0% (95% CI 88.2–94.9%), and the specificity was 64.9% (95% CI 54.6–74.4%). We observed a prevalence of SARS-CoV-2 infection of 74.7%. In this setting, the positive and negative predicted values were 88.6% (95% CI 84.4–92.0) and 73.3% (95% CI 62.6–82.2%), respectively. Lung POCUS is a sensitive first-line screening tool for ED patients presenting with symptoms suggestive of SARS-CoV-2 infection.
- 22 October 2020
- Published by Springer Nature in Internal and Emergency Medicine
- Vol. 16 (3) , 749-756
Open AccessThe role of lung ultrasound as a frontline diagnostic tool in the era of COVID-19 outbreak
The diffusion of the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) worldwide prompted the World Health Organization to declare the status of pandemic. The molecular diagnosis of SARS-CoV-2 infection is based on the detection of viral RNA on different biological specimens. Unfortunately, the test may require several hours to be performed. In the present study, we evaluated the diagnostic accuracy of lung point-of-care ultrasound (POCUS) for SARS-CoV-2 pneumonia in a cohort of symptomatic patients admitted to one emergency department (ED) in a high-prevalence setting. This retrospective study enrolled all patients who visited one ED with suspected respiratory infection in March 2020. All the patients were tested (usually twice if the first was negative) for SARS-CoV-2 on ED admission. The reference standard was considered positive if at least one specimen was positive. If all the specimens tested negative, the reference was considered negative. Diagnostic accuracy was evaluated using sensitivity, specificity, and positive and negative predictive value. Of the 444 symptomatic patients who were admitted to the ED in the study period, the result of the lung POCUS test was available for 384 (86.5%). The sensitivity of the test was 92.0% (95% CI 88.2–94.9%), and the specificity was 64.9% (95% CI 54.6–74.4%). We observed a prevalence of SARS-CoV-2 infection of 74.7%. In this setting, the positive and negative predicted values were 88.6% (95% CI 84.4–92.0) and 73.3% (95% CI 62.6–82.2%), respectively. Lung POCUS is a sensitive first-line screening tool for ED patients presenting with symptoms suggestive of SARS-CoV-2 infection.