Амин Рашитович Шабаев
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Амин Рашитович Шабаев has a total of 129 co-authors. Here are the top co-authors by number of shared publications:
- Anton Nikolaevich Kazantsev
135th Separate Medical Battalion of the Ministry of Defense of the Russian Federation
12 shared publications - Goderzi Sh. Bagdavadze
Alexandrovskaya hospital
10 shared publications - Anton G. Kutikhin
Research Institute for Complex Issues of Cardiovascular Diseases, Kemerovo, Russia
9 shared publications - Leo A. Bogdanov
Department of Experimental Medicine, Research Institute for Complex Issues of Cardiovascular Diseases, 6 Sosnovy Boulevard, 650002, Kemerovo, Russia
8 shared publications - Roman Aleksandrovich Vinogradov
Scientific Research Institute – Ochapovsky Regional Clinical Hospital no. 1; Kuban State Medical University
8 shared publications - Roman Yu. Lider
Kemerovo State Medical University
8 shared publications
Latest Publications
- Open Access
- 1 March 2026
- Published by Bentham Science Publishers Ltd. in Current Medicinal Chemistry
- Vol. 33 (9) , 1730-1758
Citrullination Accompanies the Development of Carotid Atherosclerotic Plaques
Background: Citrullination represents a post-translational modification primarily mediated by peptidylarginine deiminase (PADI) 2 and 4 and resulting in the conversion of positively charged peptidylarginine to neutrally charged peptidylcitrulline. Molecular consequences of citrullination include the generation of neoepitopes which provoke the production of autoantibodies implicated in the development of autoimmune diseases. As citrullination initiates, promotes, and is enhanced by aseptic inflammation which plays a pivotal role in atherosclerosis, we proposed that citrullination might accompany the development of atherosclerotic vascular disease. Objective: To investigate features and patterns of citrullination in atherosclerotic plaques. objective: To investigate features and patterns of citrullination in atherosclerotic plaques. Methods: We collected carotid atherosclerotic plaques (n = 14) and adjacent arterial segments (n = 14) which were pairwise excised during the carotid endarterectomy. The tissues were examined employing proteomic profiling (ultra-high performance liquid chromatography-tandem mass spectrometry analysis), haematoxylin and eosin staining, Western blotting and immunofluorescence staining for peptidylcitrulline, PADI2, and PADI4, and gene expression analysis. To better explore the mechanisms of citrullination in the neointima, we have also stained excised plaques for the extracellular vesicle markers (CD9 and CD81) and assessed co-localisation of PADI2 (a citrullination marker) with CD81 (an extracellular vesicle marker). In order to study the systemic response to citrullination in an atherosclerotic vascular disease setting, we measured the level of anti-citrullinated protein antibodies in the serum of patients with ischaemic stroke and healthy volunteers. Results: Proteomic profiling found 213 plaque-specific and 111 intact arteria-specific proteins, as well as 46 proteins and 13 proteins which have been respectively upregulated or downregulated in plaques as compared with the adjacent intact segments. Among the top 20 upregulated proteins were atherogenic apolipoprotein B-100, iron-associated protein haptoglobin, and matrix metal-loproteinase-9, together indicating the advanced stage of plaque progression. In comparison with the intact arterial segments, plaques demonstrated protein signatures of innate immune response and oxidative stress, suggesting aseptic inflammation as a driver of atherosclerotic vascular disease. Both peptidylcitrulline and PADI2 have been abundant in the neointima but negligible in tunica media; further, the levels of peptidylcitrulline, PADI2, and PADI4 were elevated in plaque lysates in comparison with those from adjacent arterial segments (p = 0.025, 0.025, and 0.010, respectively). Notably, PADI2 and peptidylcitrulline were co-localised with the cells in the neointima and a considerable proportion of PADI2 was co-localised with CD81-positive extracellular vesicles (p = 0.003). Albeit citrullinated histone H3 and myeloperoxidase showed higher signal in the neointima than in tunica media (p = 0.048 and 0.023, respectively), we did not observe any signs of neutrophil extracellular traps (e.g., unwound chromatin or co-localisation of citrullinated histone H3 with neutrophil elastase) in the plaque tissue. Serum anti-citrullinated protein antibodies were not elevated in patients with ischaemic stroke (p = 0.71), suggesting that vascular citrullination likely does not trigger a generalised immune response. Conclusions: The development of carotid atherosclerosis is associated with citrullination, although it represents a local rather than systemic phenomenon in this clinical scenario.
- 1 March 2026
- Published by Bentham Science Publishers Ltd. in Current Medicinal Chemistry
- Vol. 33 (9) , 1730-1758
Open AccessCitrullination Accompanies the Development of Carotid Atherosclerotic Plaques
Background: Citrullination represents a post-translational modification primarily mediated by peptidylarginine deiminase (PADI) 2 and 4 and resulting in the conversion of positively charged peptidylarginine to neutrally charged peptidylcitrulline. Molecular consequences of citrullination include the generation of neoepitopes which provoke the production of autoantibodies implicated in the development of autoimmune diseases. As citrullination initiates, promotes, and is enhanced by aseptic inflammation which plays a pivotal role in atherosclerosis, we proposed that citrullination might accompany the development of atherosclerotic vascular disease. Objective: To investigate features and patterns of citrullination in atherosclerotic plaques. objective: To investigate features and patterns of citrullination in atherosclerotic plaques. Methods: We collected carotid atherosclerotic plaques (n = 14) and adjacent arterial segments (n = 14) which were pairwise excised during the carotid endarterectomy. The tissues were examined employing proteomic profiling (ultra-high performance liquid chromatography-tandem mass spectrometry analysis), haematoxylin and eosin staining, Western blotting and immunofluorescence staining for peptidylcitrulline, PADI2, and PADI4, and gene expression analysis. To better explore the mechanisms of citrullination in the neointima, we have also stained excised plaques for the extracellular vesicle markers (CD9 and CD81) and assessed co-localisation of PADI2 (a citrullination marker) with CD81 (an extracellular vesicle marker). In order to study the systemic response to citrullination in an atherosclerotic vascular disease setting, we measured the level of anti-citrullinated protein antibodies in the serum of patients with ischaemic stroke and healthy volunteers. Results: Proteomic profiling found 213 plaque-specific and 111 intact arteria-specific proteins, as well as 46 proteins and 13 proteins which have been respectively upregulated or downregulated in plaques as compared with the adjacent intact segments. Among the top 20 upregulated proteins were atherogenic apolipoprotein B-100, iron-associated protein haptoglobin, and matrix metal-loproteinase-9, together indicating the advanced stage of plaque progression. In comparison with the intact arterial segments, plaques demonstrated protein signatures of innate immune response and oxidative stress, suggesting aseptic inflammation as a driver of atherosclerotic vascular disease. Both peptidylcitrulline and PADI2 have been abundant in the neointima but negligible in tunica media; further, the levels of peptidylcitrulline, PADI2, and PADI4 were elevated in plaque lysates in comparison with those from adjacent arterial segments (p = 0.025, 0.025, and 0.010, respectively). Notably, PADI2 and peptidylcitrulline were co-localised with the cells in the neointima and a considerable proportion of PADI2 was co-localised with CD81-positive extracellular vesicles (p = 0.003). Albeit citrullinated histone H3 and myeloperoxidase showed higher signal in the neointima than in tunica media (p = 0.048 and 0.023, respectively), we did not observe any signs of neutrophil extracellular traps (e.g., unwound chromatin or co-localisation of citrullinated histone H3 with neutrophil elastase) in the plaque tissue. Serum anti-citrullinated protein antibodies were not elevated in patients with ischaemic stroke (p = 0.71), suggesting that vascular citrullination likely does not trigger a generalised immune response. Conclusions: The development of carotid atherosclerosis is associated with citrullination, although it represents a local rather than systemic phenomenon in this clinical scenario.
- 30 December 2025
- Published by NII KPSSZ in Complex Issues of Cardiovascular Diseases
- Vol. 14 (6)
AN EXPERIMENT WITHOUT CONTRAST IMPLANTATION OF STENTS INTO THE CAROTID ARTERY OF SHEEP UNDER THE CONTROL OF IVUS IN AN EXPERIMENT
Highlights Contrast‑induced nephropathy is a serious complication of endovascular procedures caused by the administration of contrast media; its incidence reaches 30 %, and no effective treatments for сontrast‑induced nephropathy currently exist. The study proposes an innovative stenting technique using external and intravascular ultrasound guidance that completely eliminates the use of contrast media and fluoroscopy, thereby avoiding the risk of developing contrast‑induced nephropathy. The use of intravascular ultrasound as a substitute for conventional angiography has the potential to reduce or completely eliminate the need for fluoroscopy and contrast media during stenting; this technique has demonstrated safety and efficacy, but requires further clinical research. Aim. To develop a technique for contrast-free and fluoroscopic stenting in an experiment using intravascular ultrasound. Methods. In the experiment, six healthy sheep of the Edilbaev’s breed, under general anesthesia and under the control of percutaneous ultrasound, underwent puncture of the common carotid artery. After systemic heparinization (2 500 units), a IVUS sensor was installed to assess the reference diameter of the vessel and select the required stent size. In parallel to the sensor, the stent is placed 0.5–1.0 cm distally. After positioning, the IVUS sensor was inserted into a conductive catheter for further monitoring. The stent was implanted with a nominal pressure (9–10 atm), after which the IVUS was monitored, and when a malformation was detected, postdilation with a balloon from under the stent (14–16 atm.) was performed with a re-evaluation of the result. Coronary balloon-expandable stents were implanted in sheep, sizes 5 × 8 mm and 4.5 × 10 mm were used. Results. Suturing of the puncture site was performed using an Angio-seal device. In the postoperative period, all animals were prescribed double antiplatelet therapy. On a control ultrasound 3 months after stenting, the stents are passable. Conclusion. The problem of reducing the fluoroscopy time and the amount of contrast used remains one of the most urgent today. The use of IVUS, as a replacement for the usual angiography, can potentially lead to a decrease or even complete absence of X-ray and CA during stenting. The technique demonstrated above has shown its safety and viability. However, this methodology requires further clinical studies.
- 30 December 2025
- Published by NII KPSSZ in Complex Issues of Cardiovascular Diseases
- Vol. 14 (6)
AN EXPERIMENT WITHOUT CONTRAST IMPLANTATION OF STENTS INTO THE CAROTID ARTERY OF SHEEP UNDER THE CONTROL OF IVUS IN AN EXPERIMENT
Highlights Contrast‑induced nephropathy is a serious complication of endovascular procedures caused by the administration of contrast media; its incidence reaches 30 %, and no effective treatments for сontrast‑induced nephropathy currently exist. The study proposes an innovative stenting technique using external and intravascular ultrasound guidance that completely eliminates the use of contrast media and fluoroscopy, thereby avoiding the risk of developing contrast‑induced nephropathy. The use of intravascular ultrasound as a substitute for conventional angiography has the potential to reduce or completely eliminate the need for fluoroscopy and contrast media during stenting; this technique has demonstrated safety and efficacy, but requires further clinical research. Aim. To develop a technique for contrast-free and fluoroscopic stenting in an experiment using intravascular ultrasound. Methods. In the experiment, six healthy sheep of the Edilbaev’s breed, under general anesthesia and under the control of percutaneous ultrasound, underwent puncture of the common carotid artery. After systemic heparinization (2 500 units), a IVUS sensor was installed to assess the reference diameter of the vessel and select the required stent size. In parallel to the sensor, the stent is placed 0.5–1.0 cm distally. After positioning, the IVUS sensor was inserted into a conductive catheter for further monitoring. The stent was implanted with a nominal pressure (9–10 atm), after which the IVUS was monitored, and when a malformation was detected, postdilation with a balloon from under the stent (14–16 atm.) was performed with a re-evaluation of the result. Coronary balloon-expandable stents were implanted in sheep, sizes 5 × 8 mm and 4.5 × 10 mm were used. Results. Suturing of the puncture site was performed using an Angio-seal device. In the postoperative period, all animals were prescribed double antiplatelet therapy. On a control ultrasound 3 months after stenting, the stents are passable. Conclusion. The problem of reducing the fluoroscopy time and the amount of contrast used remains one of the most urgent today. The use of IVUS, as a replacement for the usual angiography, can potentially lead to a decrease or even complete absence of X-ray and CA during stenting. The technique demonstrated above has shown its safety and viability. However, this methodology requires further clinical studies.
- Open Access
- 29 September 2025
- Published by Kemerovo State Medical University in Fundamental and Clinical Medicine
- Vol. 10 (3) , 72-86
Electron microscopy analysis of endothelial-to-mesenchymal transition in native and prosthetic blood vessels and heart valves
Aim. To analyse the electron microscopy signs of endothelial-to-mesenchymal transition (EndoMT) in endothelial cells (ECs) of native blood vessels and medical devices for cardiovascular surgery (including vascular patches, stents, and bioprosthetic heart valves) for assessing the role of EndoMT in the pathogenesis of implantation-associated long-term complications. Materials and Methods. To achieve this task, we interrogated internal thoracic artery used as a coronary bypass conduit, ovine carotid artery with a xenopericardial patch, stented human carotid artery, and bioprosthetic aortic valve. The tissues were stained with heavy metals, embedded into epoxy resin, grinded and polished, sputter coated with carbon, and visualised using backscattered scanning electron microscopy (EM-BSEM technique). Results. All samples contained both physiological ECs and the cells undergoing EndoMT. Physiological ECs retained apicobasal polarity, elongated nucleus, and intact basement membrane. Cells undergoing EndoMT had polymorphic nuclei, loss of apicobasal polarity, degraded and disintegrated basement membrane and internal elastic lamina, and migration into the vascular wall. Numerous immune cells (i.e., neutrophils, eosinophils, and macrophages) in the subendothelial layer indicated distinct stages of inflammation and vascular or valvular remodeling. Cell undergoing EndoMT migrated into the medial layer acquiring a myofibroblastic phenotype. Conclusion. These results confirm the role of EndoMT in the pathogenesis of the complications associated with the implantation of medical devices. Signs of dysfunctional ECs and EndoMT have been accompanied by inflammation, extracellular matrix degradation, and disruption of endothelial barrier altogether promoting intimal hyperplasia and restenosis as well as structural valve deterioration. These data require the detailed investigation of EndoMT molecular mechanisms and therapeutic approaches of its prevention in patients undergoing cardiovascular surgery interventions.
- 29 September 2025
- Published by Kemerovo State Medical University in Fundamental and Clinical Medicine
- Vol. 10 (3) , 72-86
Open AccessElectron microscopy analysis of endothelial-to-mesenchymal transition in native and prosthetic blood vessels and heart valves
Aim. To analyse the electron microscopy signs of endothelial-to-mesenchymal transition (EndoMT) in endothelial cells (ECs) of native blood vessels and medical devices for cardiovascular surgery (including vascular patches, stents, and bioprosthetic heart valves) for assessing the role of EndoMT in the pathogenesis of implantation-associated long-term complications. Materials and Methods. To achieve this task, we interrogated internal thoracic artery used as a coronary bypass conduit, ovine carotid artery with a xenopericardial patch, stented human carotid artery, and bioprosthetic aortic valve. The tissues were stained with heavy metals, embedded into epoxy resin, grinded and polished, sputter coated with carbon, and visualised using backscattered scanning electron microscopy (EM-BSEM technique). Results. All samples contained both physiological ECs and the cells undergoing EndoMT. Physiological ECs retained apicobasal polarity, elongated nucleus, and intact basement membrane. Cells undergoing EndoMT had polymorphic nuclei, loss of apicobasal polarity, degraded and disintegrated basement membrane and internal elastic lamina, and migration into the vascular wall. Numerous immune cells (i.e., neutrophils, eosinophils, and macrophages) in the subendothelial layer indicated distinct stages of inflammation and vascular or valvular remodeling. Cell undergoing EndoMT migrated into the medial layer acquiring a myofibroblastic phenotype. Conclusion. These results confirm the role of EndoMT in the pathogenesis of the complications associated with the implantation of medical devices. Signs of dysfunctional ECs and EndoMT have been accompanied by inflammation, extracellular matrix degradation, and disruption of endothelial barrier altogether promoting intimal hyperplasia and restenosis as well as structural valve deterioration. These data require the detailed investigation of EndoMT molecular mechanisms and therapeutic approaches of its prevention in patients undergoing cardiovascular surgery interventions.
- Open Access
- 31 August 2025
- Published by NII KPSSZ in Complex Issues of Cardiovascular Diseases
- Vol. 14 (4) , 216-227
ATHEROSCLEROSIS SEVERITY AFFECTS ARTERIAL REMODELING AFTER THE CAROTID ANGIOPLASTY
Highlights In the examined human stented internal carotid artery sample, we identified significant differences in remodeling patterns between the initially intact intima and atherosclerotic plaque area. Severe restenosis in the initially intact intima was characterized by intensive neutrophilic infiltration, proliferation of vascular smooth muscle cells and fibroblasts, active extracellular matrix remodeling, and immature microvessels. Moderate restenosis in the atherosclerotic plaque area was characterized by the absence of neutrophils, notable macrophage infiltration, and mature microvessels. AbstractAim. To perform a histological analysis of arterial remodeling after the carotid angioplasty depending on the extent of atherosclerosis before the surgery.Methods. Here we examined human internal carotid artery excised during carotid endarterectomy which has been performed because of severe in-stent restenosis. The artery was sectioned into segments with initially intact intima (n = 3) and segments with atherosclerotic plaque (n = 3). Visualization was performed using backscattered scanning electron microscopy (EM-BSEM) after staining the segments with heavy metals, embedding them into epoxy resin, grinding and polishing of embedded specimens, and sputter coating the samples with carbon. We further assessed neointimal thickness, extracellular matrix state, microvessel parameters (total and mean lumen area, vessel density by area and quantity, presence of blood cells within and surrounding vessels), cellular composition, and immune cell infiltration patterns.Results. Significant differences in patterns of arterial remodeling were observed between the initially intact intima and atherosclerotic plaque area. Restenotic neointima in initially intact regions was thick, loose and disorganized and was notable for high cellular density, severe neutrophilic infiltration, and immature microvessels (i.e., signs of acute inflammation). In contrast, atherosclerotic plaque areas had moderate degree of restenosis, dense neointima, mature microvessels, and macrophage infiltration, altogether suggestive of chronic inflammation. Morphometric analysis revealed a trend toward increased neointimal thickness in the initially intact intima; however, microvascular parameters did not differ significantly between the intact and atherosclerotic areas.Conclusion. The initial state of the carotid artery wall affects the neointimal composition, extracellular matrix remodeling, angiogenesis and inflammation patterns. Initially intact intima exhibited high reactivity associated with a severe restenosis, loose neointima formation, and acute inflammation. In contrast, plaque areas demonstrate more stable neointimal structure and features of chronic inflammation.
- 31 August 2025
- Published by NII KPSSZ in Complex Issues of Cardiovascular Diseases
- Vol. 14 (4) , 216-227
Open AccessATHEROSCLEROSIS SEVERITY AFFECTS ARTERIAL REMODELING AFTER THE CAROTID ANGIOPLASTY
Highlights In the examined human stented internal carotid artery sample, we identified significant differences in remodeling patterns between the initially intact intima and atherosclerotic plaque area. Severe restenosis in the initially intact intima was characterized by intensive neutrophilic infiltration, proliferation of vascular smooth muscle cells and fibroblasts, active extracellular matrix remodeling, and immature microvessels. Moderate restenosis in the atherosclerotic plaque area was characterized by the absence of neutrophils, notable macrophage infiltration, and mature microvessels. AbstractAim. To perform a histological analysis of arterial remodeling after the carotid angioplasty depending on the extent of atherosclerosis before the surgery.Methods. Here we examined human internal carotid artery excised during carotid endarterectomy which has been performed because of severe in-stent restenosis. The artery was sectioned into segments with initially intact intima (n = 3) and segments with atherosclerotic plaque (n = 3). Visualization was performed using backscattered scanning electron microscopy (EM-BSEM) after staining the segments with heavy metals, embedding them into epoxy resin, grinding and polishing of embedded specimens, and sputter coating the samples with carbon. We further assessed neointimal thickness, extracellular matrix state, microvessel parameters (total and mean lumen area, vessel density by area and quantity, presence of blood cells within and surrounding vessels), cellular composition, and immune cell infiltration patterns.Results. Significant differences in patterns of arterial remodeling were observed between the initially intact intima and atherosclerotic plaque area. Restenotic neointima in initially intact regions was thick, loose and disorganized and was notable for high cellular density, severe neutrophilic infiltration, and immature microvessels (i.e., signs of acute inflammation). In contrast, atherosclerotic plaque areas had moderate degree of restenosis, dense neointima, mature microvessels, and macrophage infiltration, altogether suggestive of chronic inflammation. Morphometric analysis revealed a trend toward increased neointimal thickness in the initially intact intima; however, microvascular parameters did not differ significantly between the intact and atherosclerotic areas.Conclusion. The initial state of the carotid artery wall affects the neointimal composition, extracellular matrix remodeling, angiogenesis and inflammation patterns. Initially intact intima exhibited high reactivity associated with a severe restenosis, loose neointima formation, and acute inflammation. In contrast, plaque areas demonstrate more stable neointimal structure and features of chronic inflammation.
- Open Access
- 12 July 2025
- Published by V.I. Shimakov Federal Research Center of Transplantology and Artificial Organs in Russian Journal of Transplantology and Artificial Organs
- Vol. 27 (2) , 127-138
Preclinical evaluation of tissue-engineered vascular grafts with biodegradable components: assessing the effectiveness of animal models from rats to primates
Currently, there are no highly effective small-diameter (≤4 mm) grafts on the market for cardiovascular surgery. Tissue-engineered, functionally active vascular grafts with prolonged resorption and regeneration capacity have the potential to serve as alternatives to traditional arterial grafts. These bioengineered grafts could eliminate the need for repeated surgical interventions to replace failed grafts. The accuracy of assessing the risks of failure in biodegradable small-diameter vascular grafts (SDVGs) during preclinical trials is highly dependent on the choice of animal model. This article presents the results of comprehensive preclinical trials conducted on an SDVG developed at the Research Institute for Complex Issues of Cardiovascular Diseases. Based on these findings, the study evaluates the effectiveness and feasibility of different animal models for testing biodegradable SDVGs.
- 12 July 2025
- Published by V.I. Shimakov Federal Research Center of Transplantology and Artificial Organs in Russian Journal of Transplantology and Artificial Organs
- Vol. 27 (2) , 127-138
Open AccessPreclinical evaluation of tissue-engineered vascular grafts with biodegradable components: assessing the effectiveness of animal models from rats to primates
Currently, there are no highly effective small-diameter (≤4 mm) grafts on the market for cardiovascular surgery. Tissue-engineered, functionally active vascular grafts with prolonged resorption and regeneration capacity have the potential to serve as alternatives to traditional arterial grafts. These bioengineered grafts could eliminate the need for repeated surgical interventions to replace failed grafts. The accuracy of assessing the risks of failure in biodegradable small-diameter vascular grafts (SDVGs) during preclinical trials is highly dependent on the choice of animal model. This article presents the results of comprehensive preclinical trials conducted on an SDVG developed at the Research Institute for Complex Issues of Cardiovascular Diseases. Based on these findings, the study evaluates the effectiveness and feasibility of different animal models for testing biodegradable SDVGs.
- Open Access
- 28 December 2024
- Published by NII KPSSZ in Complex Issues of Cardiovascular Diseases
- Vol. 13 (4) , 77-89
SELECTION OF POLYMER FOR STENT-GRAFT COATING IN TERMS OF BIOCOMPATIBILITY AND BIODEGRADATION CHARACTERISTICS
HighlightsCoated stents or stent-grafts are widely used in endovascular surgery to close arterial perforations, dissections and aneurysms, as well as in stenting of arteries with loose atherosclerotic plaques in order to reduce the risk of emboli and strokes. The material of stent coating is of great importance in the prevention of early thrombosis and restenosis of stent grafts. Biodegradable polymers have an advantage over non-biodegradable polymers because they do not remain in the patient's tissues for a long period of time and do not cause chronic inflammation. The study of the dynamics and biodegradation characteristics of polymer coating can provide information about its suitability and safety in the stent graft. Annotation Aim. To screen potentially suitable polymers for stent-graft coating with the following assessment of biocompatibility and biodegradation dynamics in an in vivo experiment.Methods. The coating was applied on the stent by electrospinning from a solution of polymers: Polycaprolactone (PCL); polydioxanone (PDO); polylactide-co-caprolactone (P(LA/CL)) with lactide: caprolactone ratio – 70:30; polylactide-co-glycolide (PLGA) with lactide: glycolide ratio – 50:50. Chloroform (CHCl3) and 1,1,1,1,3,3,3,3,3-hexafluoro-2-propanol (HFP) were used as a solvent. Gore-Tex polymer membrane made of polytetrafluoroethylene (ePTFE) was used as control. In order to evaluate biocompatibility and biodegradation dynamics in vivo, the studied polymeric samples were implanted subcutaneously in male Wistar rats for periods of 7 and 14 days, 1, 2, 3 and 6 months. After explantation all samples were studied histologically.Results. 14 days after implantation a moderate inflammatory reaction developed on all polymer specimens. The PTFE material was separated from the surrounding tissues by a thin ordered fibrous capsule, confirming its satisfactory biocompatible properties. The porous structure of PCL membranes was filled by fibroblasts and the specimens were tightly integrated into the surrounding tissues. P(LA/CL) degrades with the formation of large fragments. The composite polymer P(LA/CL)/PDO degraded to form small fragments that are tightly integrated with the fibrous capsule. PLGA membranes showed high rates of degradation - membrane fragments were detected 3 months after implantation, after 6 months the samples were completely degraded.Conclusion. The results of biocompatibility and biodegradation assessment in vivo indicate that the most promising polymers for stent-graft creation are PCL, PLGA and composite polymer P(LA/CL)/PDO. In order to finalize the choice of polymer, it is necessary to conduct further studies to assess the biocompatibility and degradation of polymer coating during implantation of stent-grafts into the arterial bed of large laboratory animals.
- 28 December 2024
- Published by NII KPSSZ in Complex Issues of Cardiovascular Diseases
- Vol. 13 (4) , 77-89
Open AccessSELECTION OF POLYMER FOR STENT-GRAFT COATING IN TERMS OF BIOCOMPATIBILITY AND BIODEGRADATION CHARACTERISTICS
HighlightsCoated stents or stent-grafts are widely used in endovascular surgery to close arterial perforations, dissections and aneurysms, as well as in stenting of arteries with loose atherosclerotic plaques in order to reduce the risk of emboli and strokes. The material of stent coating is of great importance in the prevention of early thrombosis and restenosis of stent grafts. Biodegradable polymers have an advantage over non-biodegradable polymers because they do not remain in the patient's tissues for a long period of time and do not cause chronic inflammation. The study of the dynamics and biodegradation characteristics of polymer coating can provide information about its suitability and safety in the stent graft. Annotation Aim. To screen potentially suitable polymers for stent-graft coating with the following assessment of biocompatibility and biodegradation dynamics in an in vivo experiment.Methods. The coating was applied on the stent by electrospinning from a solution of polymers: Polycaprolactone (PCL); polydioxanone (PDO); polylactide-co-caprolactone (P(LA/CL)) with lactide: caprolactone ratio – 70:30; polylactide-co-glycolide (PLGA) with lactide: glycolide ratio – 50:50. Chloroform (CHCl3) and 1,1,1,1,3,3,3,3,3-hexafluoro-2-propanol (HFP) were used as a solvent. Gore-Tex polymer membrane made of polytetrafluoroethylene (ePTFE) was used as control. In order to evaluate biocompatibility and biodegradation dynamics in vivo, the studied polymeric samples were implanted subcutaneously in male Wistar rats for periods of 7 and 14 days, 1, 2, 3 and 6 months. After explantation all samples were studied histologically.Results. 14 days after implantation a moderate inflammatory reaction developed on all polymer specimens. The PTFE material was separated from the surrounding tissues by a thin ordered fibrous capsule, confirming its satisfactory biocompatible properties. The porous structure of PCL membranes was filled by fibroblasts and the specimens were tightly integrated into the surrounding tissues. P(LA/CL) degrades with the formation of large fragments. The composite polymer P(LA/CL)/PDO degraded to form small fragments that are tightly integrated with the fibrous capsule. PLGA membranes showed high rates of degradation - membrane fragments were detected 3 months after implantation, after 6 months the samples were completely degraded.Conclusion. The results of biocompatibility and biodegradation assessment in vivo indicate that the most promising polymers for stent-graft creation are PCL, PLGA and composite polymer P(LA/CL)/PDO. In order to finalize the choice of polymer, it is necessary to conduct further studies to assess the biocompatibility and degradation of polymer coating during implantation of stent-grafts into the arterial bed of large laboratory animals.
- Open Access
- 29 December 2023
- Published by NII KPSSZ in Complex Issues of Cardiovascular Diseases
- Vol. 12 (4S) , 110-119
FEATURES OF POLYURETHANE MATRIX REMODELING IN SHEEP MODEL EXPERIMENTS
HighlightsThe article describes the features of remodeling of polyurethane matrices during long-term implantation into the vascular bed of sheep. The results indicate high biocompatibility of polyurethane and resistance to bioresorption. The obtained data are significant for the development of medical products for cardiovascular surgery, in particular, biodegradable vascular prostheses. AbstractAim. To evaluate the features of polyurethane remodeling in a long-term experiment on a large animal model.Methods. Matrices made of 12% polyurethane solution in chloroform were manufactured by electrospinning at the Nanon-01A nanofiber electrospinning system (MIC, Japan). Matrix samples in the form of patches were implanted into the carotid arteries of sheep (n = 3) for a period of 6 months. The patency of vessels with implanted matrices was assessed after 2, 4 and 6 months using a portable hand-carried color Doppler - M7 Premium Ultrasound Machine (Mindray, China). The structure of the matrix surface before and after implantation was studied using an S-3400N scanning electron microscope (Hitachi, Japan). Histological examination of the explanted samples was carried out using an AXIO Imager A1 microscope (Carl Zeiss, Oberkochen, Germany) with previous staining of matrix sections with hematoxylin-eosin, Van Gieson and alizarin red C. Data processing was performed using the Statistica 6.0 software.Results. After 2, 4 and 6 months of implantation of polyurethane matrices into the carotid artery of sheep, complete patency of the carotid arteries was revealed. Macroscopically, after 6 months of implantation, the matrix completely resembled the carotid artery wall due to the full consolidation of the matrix with the artery wall and remodeling. Layers of newly formed vascular tissue – neointima and neoadventitia – were formed on the basis of the matrix. Histological examination revealed the structural integrity of the matrix without signs of inflammation and calcification both in the matrix structure and adjacent tissues.Conclusion. The biological inertia of polyurethane matrices with signs of remodeling was noted, which indicates a high biocompatibility of the material. Resistance to bioresorption and the ability to keep the frame of the product for a long time allows us to consider polyurethane as a suitable material for the formation of anti-aneurysmal protection of biodegradable vascular prostheses.
- 29 December 2023
- Published by NII KPSSZ in Complex Issues of Cardiovascular Diseases
- Vol. 12 (4S) , 110-119
Open AccessFEATURES OF POLYURETHANE MATRIX REMODELING IN SHEEP MODEL EXPERIMENTS
HighlightsThe article describes the features of remodeling of polyurethane matrices during long-term implantation into the vascular bed of sheep. The results indicate high biocompatibility of polyurethane and resistance to bioresorption. The obtained data are significant for the development of medical products for cardiovascular surgery, in particular, biodegradable vascular prostheses. AbstractAim. To evaluate the features of polyurethane remodeling in a long-term experiment on a large animal model.Methods. Matrices made of 12% polyurethane solution in chloroform were manufactured by electrospinning at the Nanon-01A nanofiber electrospinning system (MIC, Japan). Matrix samples in the form of patches were implanted into the carotid arteries of sheep (n = 3) for a period of 6 months. The patency of vessels with implanted matrices was assessed after 2, 4 and 6 months using a portable hand-carried color Doppler - M7 Premium Ultrasound Machine (Mindray, China). The structure of the matrix surface before and after implantation was studied using an S-3400N scanning electron microscope (Hitachi, Japan). Histological examination of the explanted samples was carried out using an AXIO Imager A1 microscope (Carl Zeiss, Oberkochen, Germany) with previous staining of matrix sections with hematoxylin-eosin, Van Gieson and alizarin red C. Data processing was performed using the Statistica 6.0 software.Results. After 2, 4 and 6 months of implantation of polyurethane matrices into the carotid artery of sheep, complete patency of the carotid arteries was revealed. Macroscopically, after 6 months of implantation, the matrix completely resembled the carotid artery wall due to the full consolidation of the matrix with the artery wall and remodeling. Layers of newly formed vascular tissue – neointima and neoadventitia – were formed on the basis of the matrix. Histological examination revealed the structural integrity of the matrix without signs of inflammation and calcification both in the matrix structure and adjacent tissues.Conclusion. The biological inertia of polyurethane matrices with signs of remodeling was noted, which indicates a high biocompatibility of the material. Resistance to bioresorption and the ability to keep the frame of the product for a long time allows us to consider polyurethane as a suitable material for the formation of anti-aneurysmal protection of biodegradable vascular prostheses.
- Open Access
- 9 April 2023
- Published by Cardiology Research Institute in Siberian Journal of Clinical and Experimental Medicine
- Vol. 38 (1) , 151-159
Features of remodeling of newly formed vascular tissue based on biodegradable vascular prostheses implanted in the carotid artery of sheep: morphogenetic analysis
Tissue-engineered vascular prostheses developed for prosthesis of small-diameter arteries have high biocompatibility and coverage of their patency after implantation into the vascular bed, and should also show a high probability of forming on their basis a newly formed tissue that is largely susceptible to native vascular tissue.Aim: To evaluate the expected patency of biodegradable vascular prostheses with athrombogenic drug coating in large laboratory animal models.Material and Methods. Vascular prostheses Ø 4 mm were fabricated by electrospinning from a polymer composition of 5% polyhydrosibutyrate/valeriate (PHBV) and 10% polycaprolactone (PCL) and a complex of proangiogenic tissues (GFmix): vascular endothelial growth (VEGF), rare fibroblast growth (bFGF) and chemoattractant molecule (SDF-1α). To induce thromboresistant properties of grafts, an athrombogenic modification of the surface of parts of the fabricated prostheses with heparin and iloprost was carried out. Modified prostheses were implanted in the carotid artery for a period of 12 months. The group with autoarterial implantation acted as a control.Results. In 12 months after implantation, the patency of auto-arterial grafts was 87.5%. The patency of PHBV/PCL/GFmix with heparin and iloprost reached 50% at the time of implantation. The biodegradable frame made of reinforced prostheses was almost completely resorbed with the formation of aneurysms throughout. In the modified prostheses, the main elements of the newly formed vascular tissue are present. There is no formation in the walls of the prostheses.Conclusion. The results showed that biodegradable vascular prostheses PHBV/PCL/GFmixHep/Ilo have a high final patency, which allows us to consider them suitable for the formation of newly formed vascular tissue on their basis. However, due to the aneurysm formation, a long-term execution of the bone tissue of the prosthesis and the thrombogenic properties of the inner surface are required.
- 9 April 2023
- Published by Cardiology Research Institute in Siberian Journal of Clinical and Experimental Medicine
- Vol. 38 (1) , 151-159
Open AccessFeatures of remodeling of newly formed vascular tissue based on biodegradable vascular prostheses implanted in the carotid artery of sheep: morphogenetic analysis
Tissue-engineered vascular prostheses developed for prosthesis of small-diameter arteries have high biocompatibility and coverage of their patency after implantation into the vascular bed, and should also show a high probability of forming on their basis a newly formed tissue that is largely susceptible to native vascular tissue.Aim: To evaluate the expected patency of biodegradable vascular prostheses with athrombogenic drug coating in large laboratory animal models.Material and Methods. Vascular prostheses Ø 4 mm were fabricated by electrospinning from a polymer composition of 5% polyhydrosibutyrate/valeriate (PHBV) and 10% polycaprolactone (PCL) and a complex of proangiogenic tissues (GFmix): vascular endothelial growth (VEGF), rare fibroblast growth (bFGF) and chemoattractant molecule (SDF-1α). To induce thromboresistant properties of grafts, an athrombogenic modification of the surface of parts of the fabricated prostheses with heparin and iloprost was carried out. Modified prostheses were implanted in the carotid artery for a period of 12 months. The group with autoarterial implantation acted as a control.Results. In 12 months after implantation, the patency of auto-arterial grafts was 87.5%. The patency of PHBV/PCL/GFmix with heparin and iloprost reached 50% at the time of implantation. The biodegradable frame made of reinforced prostheses was almost completely resorbed with the formation of aneurysms throughout. In the modified prostheses, the main elements of the newly formed vascular tissue are present. There is no formation in the walls of the prostheses.Conclusion. The results showed that biodegradable vascular prostheses PHBV/PCL/GFmixHep/Ilo have a high final patency, which allows us to consider them suitable for the formation of newly formed vascular tissue on their basis. However, due to the aneurysm formation, a long-term execution of the bone tissue of the prosthesis and the thrombogenic properties of the inner surface are required.
- Open Access
- 4 January 2023
- Published by Silicea - Poligraf, LLC in Russian Journal of Cardiology
- Vol. 27 (12) , 5064
Quantification of the initial levels of calciprotein particles as a screening marker of mineral homeostasis in patients with cardiovascular disease and in patients with chronic kidney disease
Aim. To evaluate the initial concentration of calciprotein particles (CPPs), which are scavengers of excessive calcium and phosphate, in patients with cardiovascular disease and in patients with chronic kidney disease as compared with the healthy volunteers.Material and methods. The study included 308 individuals as follows: 1) 88 participants of the PURE study without hemodynamically relevant carotid athero scle rosis and symptomatic coronary atherosclerosis; 2) 88 patients with cere brovascular disease (CVD) who required carotid endarterectomy; 3) 88 pa tients with coronary artery disease (CAD) who required percutaneous coronary intervention or coronary artery bypass graft surgery; 4) 63 patients with stage 5 chronic kidney disease (CKD). We measured following mineral homeostasis parameters: total and ionized calcium, phosphate, total protein, albumin, and fetuin-A. Then, we determined a baseline serum CPP concentration by flow cytometry using a fluorescent-labeled bisphosphonate OsteoSense 680EX. Results. In comparison with other patients, healthy volunteers had the highest serum CPP concentration (249 CPPs/µL), indicating the retained ability to compensate mineral homeostasis disturbances by aggregation of excessive calcium and pho sphate with acidic proteins (mineral chaperones). Reduced serum CPP concentration in patients with CVD (170 CPPs/µL), CAD (139 CPPs/µL), and stage 5 CKD (193-203 CPPs/µL) showed impaired aggregation of excessive serum calcium and phosphate, which was also reflected by an increased level of blood ionized calcium.Conclusion. Patients with CVD, CAD, and stage 5 CKD have lower serum CPP concentration than healthy individuals. In combination with elevated ionized calcium and reduced albumin, this suggests the depletion of calcium binding buffers in the serum of patients with cardiovascular and renal diseases.
- 4 January 2023
- Published by Silicea - Poligraf, LLC in Russian Journal of Cardiology
- Vol. 27 (12) , 5064
Open AccessQuantification of the initial levels of calciprotein particles as a screening marker of mineral homeostasis in patients with cardiovascular disease and in patients with chronic kidney disease
Aim. To evaluate the initial concentration of calciprotein particles (CPPs), which are scavengers of excessive calcium and phosphate, in patients with cardiovascular disease and in patients with chronic kidney disease as compared with the healthy volunteers.Material and methods. The study included 308 individuals as follows: 1) 88 participants of the PURE study without hemodynamically relevant carotid athero scle rosis and symptomatic coronary atherosclerosis; 2) 88 patients with cere brovascular disease (CVD) who required carotid endarterectomy; 3) 88 pa tients with coronary artery disease (CAD) who required percutaneous coronary intervention or coronary artery bypass graft surgery; 4) 63 patients with stage 5 chronic kidney disease (CKD). We measured following mineral homeostasis parameters: total and ionized calcium, phosphate, total protein, albumin, and fetuin-A. Then, we determined a baseline serum CPP concentration by flow cytometry using a fluorescent-labeled bisphosphonate OsteoSense 680EX. Results. In comparison with other patients, healthy volunteers had the highest serum CPP concentration (249 CPPs/µL), indicating the retained ability to compensate mineral homeostasis disturbances by aggregation of excessive calcium and pho sphate with acidic proteins (mineral chaperones). Reduced serum CPP concentration in patients with CVD (170 CPPs/µL), CAD (139 CPPs/µL), and stage 5 CKD (193-203 CPPs/µL) showed impaired aggregation of excessive serum calcium and phosphate, which was also reflected by an increased level of blood ionized calcium.Conclusion. Patients with CVD, CAD, and stage 5 CKD have lower serum CPP concentration than healthy individuals. In combination with elevated ionized calcium and reduced albumin, this suggests the depletion of calcium binding buffers in the serum of patients with cardiovascular and renal diseases.
- Open Access
- 17 January 2022
- Published by The Scientific and Practical Society of Emergency Medicine Physicians in Russian Sklifosovsky Journal "Emergency Medical Care"
- Vol. 10 (4) , 649-658
Multicenter Study of Resistant Arterial Hypertension Course After Classic and Eversion Carotid Endarterectomy
Aim of study. Analysis of the dynamics of resistant arterial hypertension (RAH) and the spectrum of adverse cardiovascular events in patients after classical carotid endarterectomy (CEE) with preservation of carotid body (CB) and eversion CEE with CB transection.Material and methods. This cohort, comparative, retrospective, open-label study from January 2014 to December 2020 included 761 patients with hemodynamically significant stenosis of the internal carotid arteries (ICA) and RH lasting more than 3 years. Depending on the implemented revascularization strategy, 2 groups were formed: Group 1: 38.0% (n=289) — classical CEE with plasty of the reconstruction zone with a patch (made of diepoxy-treated xenopericardium or synthetic); Group 2: 62% (n=472) — eversion CEE with CB transection. To study the dynamics of systolic blood pressure (SBP) in the preoperative period for 4 days, and in the postoperative period, blood pressure was measured for 10 days (during the period when the patient was in intensive care - according to daily monitoring of blood pressure; in the department - 10 times per day, daily). The average SBP figures for all patients were taken into account when constructing a graph of BP fluctuations.Results. In the postoperative period, the groups were comparable in the frequency of the following events: death (group 1: 0.34% (n=1), group 2: 0.63% (n=3); p=0.98; OR 0.54; 95% CI 0.05–5.21), myocardial infarction (group 1: 0.34% (n=1), group 2: 0.84% (n=4); p=0.71; OR 0, 40; 95% CI 0.04–3.65), ischemic stroke (group 1: 0.34% (n=1), group 2: 1.27% (n=6); p=0.36; OR 0.26; 95% CI 0.03–2.25), hemorrhagic transformation (group 1: 0%, group 2: 0.84% (n=4); p=0.29; OR 0.17; 95% CI 0.009–3.35). However, in terms of the number of all complications (death + myocardial infarction + ischemic stroke + hemorrhagic transformation) presented as a combined endpoint, patients after eversion CEE with CB transection were three times superior to classical surgery (group 1: 1.03% (n=3 ), group 2: 3.60% (n=17); p=0.05; OR 0.28; 95% CI 0.08–0.9).Conclusion. The choice of a revascularization strategy in patients with hemodynamically significant ICA stenosis should be personalized and based on the conclusion of a multidisciplinary consultation, and not only on the preferences of the operating surgeon. In patients with RH, it is more expedient to use classical CEE with plasty of the reconstruction zone with a patch in view of the preservation of the CB during this operation. The intersection of the latter with eversion CEE provokes labile hypertension, progression of RAH and a statistically significant increase in the number of all unfavorable cardiovascular events. Thus, the use of carotid body preserving CEE in patients with RAH confirms the therapeutic mechanism of this manipulation in achieving the target SBP level.
- 17 January 2022
- Published by The Scientific and Practical Society of Emergency Medicine Physicians in Russian Sklifosovsky Journal "Emergency Medical Care"
- Vol. 10 (4) , 649-658
Open AccessMulticenter Study of Resistant Arterial Hypertension Course After Classic and Eversion Carotid Endarterectomy
Aim of study. Analysis of the dynamics of resistant arterial hypertension (RAH) and the spectrum of adverse cardiovascular events in patients after classical carotid endarterectomy (CEE) with preservation of carotid body (CB) and eversion CEE with CB transection.Material and methods. This cohort, comparative, retrospective, open-label study from January 2014 to December 2020 included 761 patients with hemodynamically significant stenosis of the internal carotid arteries (ICA) and RH lasting more than 3 years. Depending on the implemented revascularization strategy, 2 groups were formed: Group 1: 38.0% (n=289) — classical CEE with plasty of the reconstruction zone with a patch (made of diepoxy-treated xenopericardium or synthetic); Group 2: 62% (n=472) — eversion CEE with CB transection. To study the dynamics of systolic blood pressure (SBP) in the preoperative period for 4 days, and in the postoperative period, blood pressure was measured for 10 days (during the period when the patient was in intensive care - according to daily monitoring of blood pressure; in the department - 10 times per day, daily). The average SBP figures for all patients were taken into account when constructing a graph of BP fluctuations.Results. In the postoperative period, the groups were comparable in the frequency of the following events: death (group 1: 0.34% (n=1), group 2: 0.63% (n=3); p=0.98; OR 0.54; 95% CI 0.05–5.21), myocardial infarction (group 1: 0.34% (n=1), group 2: 0.84% (n=4); p=0.71; OR 0, 40; 95% CI 0.04–3.65), ischemic stroke (group 1: 0.34% (n=1), group 2: 1.27% (n=6); p=0.36; OR 0.26; 95% CI 0.03–2.25), hemorrhagic transformation (group 1: 0%, group 2: 0.84% (n=4); p=0.29; OR 0.17; 95% CI 0.009–3.35). However, in terms of the number of all complications (death + myocardial infarction + ischemic stroke + hemorrhagic transformation) presented as a combined endpoint, patients after eversion CEE with CB transection were three times superior to classical surgery (group 1: 1.03% (n=3 ), group 2: 3.60% (n=17); p=0.05; OR 0.28; 95% CI 0.08–0.9).Conclusion. The choice of a revascularization strategy in patients with hemodynamically significant ICA stenosis should be personalized and based on the conclusion of a multidisciplinary consultation, and not only on the preferences of the operating surgeon. In patients with RH, it is more expedient to use classical CEE with plasty of the reconstruction zone with a patch in view of the preservation of the CB during this operation. The intersection of the latter with eversion CEE provokes labile hypertension, progression of RAH and a statistically significant increase in the number of all unfavorable cardiovascular events. Thus, the use of carotid body preserving CEE in patients with RAH confirms the therapeutic mechanism of this manipulation in achieving the target SBP level.