Long Shao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Long Shao has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Wei Huang
Department of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
6 shared publications - Xiang-Dong Wu
Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Capital Medical University, Fengtai, China
3 shared publications Ting Wang
Department of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, No. 1 Youyi Road, Yuan Jiagang, Yuzhong District, Chongqing, China
2 shared publications- Ting Wang
Department of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, No.1, Yixueyuan Road, Yuanjiagang, Yuzhong District, Chongqing, China
2 shared publications Wei Xu
Department of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, No. 1 Youyi Road, Yuan Jiagang, Yuzhong District, Chongqing, China
2 shared publications- Wei Xu
Department of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, No.1, Yixueyuan Road, Yuanjiagang, Yuzhong District, Chongqing, China
2 shared publications
Latest Publications
- 27 July 2021
- Published by American Medical Association (AMA) in JAMA
- Vol. 326 (4) , 358
Effect of Ventral vs Dorsal Spinal Surgery in Patients With Cervical Spondylotic Myelopathy
To the Editor The recently published CSM-S trial1 demonstrated that both ventral and dorsal surgical approaches performed equally well in patients with cervical spondylotic myelopathy. We have several comments about this study. First, while Dr Ghogawala and colleagues have used randomized clinical trials comparing the ventral and dorsal approaches,2-4 they refined the eligibility criteria to a patient population suitable for either surgical approach. The careful selection of patients provided clinical equipoise but also reduces the generalizability of their findings.1 For patients who met the study inclusion criteria, patient-reported physical functioning at 1 year was similar with the ventral and dorsal surgical approaches. However, a dorsal approach is often preferred if there is ossification of the posterior longitudinal ligament with preserved cervical lordosis or multilevel compression from predominantly dorsal pathology. A ventral approach is more suitable for cervical lordosis or predominantly ventral compressive pathology over a limited number of vertebral segments.
- 27 July 2021
- Published by American Medical Association (AMA) in JAMA
- Vol. 326 (4) , 358
Effect of Ventral vs Dorsal Spinal Surgery in Patients With Cervical Spondylotic Myelopathy
To the Editor The recently published CSM-S trial1 demonstrated that both ventral and dorsal surgical approaches performed equally well in patients with cervical spondylotic myelopathy. We have several comments about this study. First, while Dr Ghogawala and colleagues have used randomized clinical trials comparing the ventral and dorsal approaches,2-4 they refined the eligibility criteria to a patient population suitable for either surgical approach. The careful selection of patients provided clinical equipoise but also reduces the generalizability of their findings.1 For patients who met the study inclusion criteria, patient-reported physical functioning at 1 year was similar with the ventral and dorsal surgical approaches. However, a dorsal approach is often preferred if there is ossification of the posterior longitudinal ligament with preserved cervical lordosis or multilevel compression from predominantly dorsal pathology. A ventral approach is more suitable for cervical lordosis or predominantly ventral compressive pathology over a limited number of vertebral segments.
- Open Access
- 23 October 2020
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 36 (3) , 617-618
Cardiovascular Safety of Denosumab Across Multiple Indications
- 23 October 2020
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 36 (3) , 617-618
Open AccessCardiovascular Safety of Denosumab Across Multiple Indications
- Open Access
- 29 June 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-9
Approximating the maximum tibial coverage in total knee arthroplasty does not necessarily result in implant malrotation
Traditionally, the practice of the tibial component placement in total knee arthroplasty has focused on achieving maximum coverage without malrotation. However, the concept of maximizing coverage has not been well defined or researched and yet biased results are often produced. This study aimed to evaluate the effect of a prioritizing maximum coverage positioning strategy on the rotational alignment by using a strict computer algorithm. Computed tomographic scans of 103 tibial specimens were used to reconstruct three-dimensional tibia models. A virtual surgery was performed to generate the resection plane with a posterior slope of 7° on the proximal tibia. Symmetrical and anatomical tibial components were placed and analyzed with an automated program designed for approximating the maximum coverage based on the coherent point drift algorithm. We found that the average tibial coverage achieved across all specimens and implants was 85.62 ± 3.65%, ranging from 83.64 ± 4.10% to 86.69 ± 3.07%. When placed for maximal tibial coverage, the mean degree of rotation related to the Insall line was − 0.73° ± 4.53° for all subjects, 23% of the tibial components were malrotated. The average percentage position of the baseplate anteroposterior axis over the patellar tendon was 26.95 ± 14.71% from the medial edge. These results suggest that with specific design and proper placement of the component, approximating the maximum tibial coverage in total knee arthroplasty does not necessarily result in implant malrotation. The current tibial baseplates have shown good performance on the coverage when aligned parallel to the Insall line with the anteroposterior axis positioned between the medial 1/3 and medial 1/6 of the patella tendon.
- 29 June 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-9
Open AccessApproximating the maximum tibial coverage in total knee arthroplasty does not necessarily result in implant malrotation
Traditionally, the practice of the tibial component placement in total knee arthroplasty has focused on achieving maximum coverage without malrotation. However, the concept of maximizing coverage has not been well defined or researched and yet biased results are often produced. This study aimed to evaluate the effect of a prioritizing maximum coverage positioning strategy on the rotational alignment by using a strict computer algorithm. Computed tomographic scans of 103 tibial specimens were used to reconstruct three-dimensional tibia models. A virtual surgery was performed to generate the resection plane with a posterior slope of 7° on the proximal tibia. Symmetrical and anatomical tibial components were placed and analyzed with an automated program designed for approximating the maximum coverage based on the coherent point drift algorithm. We found that the average tibial coverage achieved across all specimens and implants was 85.62 ± 3.65%, ranging from 83.64 ± 4.10% to 86.69 ± 3.07%. When placed for maximal tibial coverage, the mean degree of rotation related to the Insall line was − 0.73° ± 4.53° for all subjects, 23% of the tibial components were malrotated. The average percentage position of the baseplate anteroposterior axis over the patellar tendon was 26.95 ± 14.71% from the medial edge. These results suggest that with specific design and proper placement of the component, approximating the maximum tibial coverage in total knee arthroplasty does not necessarily result in implant malrotation. The current tibial baseplates have shown good performance on the coverage when aligned parallel to the Insall line with the anteroposterior axis positioned between the medial 1/3 and medial 1/6 of the patella tendon.
- Open Access
- 12 March 2020
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 35 (5) , 998-999
The Efficacy of Denosumab for Prevention of Early Periprosthetic Bone Loss After Cementless Total Hip Arthroplasty
- 12 March 2020
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 35 (5) , 998-999
Open AccessThe Efficacy of Denosumab for Prevention of Early Periprosthetic Bone Loss After Cementless Total Hip Arthroplasty
- 3 May 2019
- Published by Springer Nature in International Orthopaedics
- Vol. 43 (11) , 2467-2475
Comparison of morphological changes of gluteus medius and abductor strength for total hip arthroplasty via posterior and modified direct lateral approaches
It is a general belief among orthopedists that the muscle damage of the hip abductors after total hip arthroplasty (THA) is theoretically minimal via posterior approach. However, there is little data scientifically supporting the purported advantage. The purpose of this study was to quantifiably assess the injury to the gluteus medius (GMED) after THA via the minimally invasive (MIS) posterior and the modified direct lateral (mDL) approaches.
- 3 May 2019
- Published by Springer Nature in International Orthopaedics
- Vol. 43 (11) , 2467-2475
Comparison of morphological changes of gluteus medius and abductor strength for total hip arthroplasty via posterior and modified direct lateral approaches
It is a general belief among orthopedists that the muscle damage of the hip abductors after total hip arthroplasty (THA) is theoretically minimal via posterior approach. However, there is little data scientifically supporting the purported advantage. The purpose of this study was to quantifiably assess the injury to the gluteus medius (GMED) after THA via the minimally invasive (MIS) posterior and the modified direct lateral (mDL) approaches.
- Open Access
- 14 January 2019
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 20 (1) , 22
Surgical injury and repair of hip external rotators in THA via posterior approach: a three-dimensional MRI-evident quantitative prospective study
As one of the classical total hip arthroplasty (THA) approaches, the posterior approach is widely used. However, there is a lack of in-depth quantitative researches on the surgical-related injury to the hip external rotators. The purpose of this study is to quantificationally analyse the surgical injury of hip external rotators after posterior THA and explore the effect of the muscle repair on the muscle recovery using the MRI three-dimensional reconstruction technique combined with the clinical assessment. Sixty five patients were eligible to receive a unilateral cementless THA via the posterior approach. During operation, the piriformis tendon was reattached but it was not applicable for the internal obturator muscle. We performed three-dimensional MRI reconstruction of bilateral piriformis and internal obturator muscle along with clinical assessment preoperatively, 6, 12 and 52 weeks postoperatively. Bilateral piriformis and internal obturator muscle were homogeneous preoperatively. Compared with the contralateral side, the volume atrophy and fat-muscle ratio of the piriformis on the operated side increased inconspicuously by 1.64%, 0.26% (p = 0.062, p = 0.071) at 6 weeks and 1.33%, 0.20% (p = 0.057, p = 0.058) at 12 weeks, while 7.28%, 2.09% and 15.71%, 5.14% for the internal obturator muscle (p < 0.01). Up to 52 weeks, the pirformis also showed significant muscle atrophy as well as fatty infiltration (increased by 7.79%, 4.21%; p < 0.01), and 24.18%, 11.91% for the internal obturator muscle (p < 0.01). The THA via posterior approach significantly harms the hip external rotators and the early hip external rotation function. The effective repair could be conducive to the early postoperative recovery of the hip external rotators. The study has been registered in Chinese Clinical Trial Registry (ChiCTR) before the clical trial started, the Clinical Trial Registry Number is ChiCTR-IOR-17013007 . Registered 17 October 2017. The Trial registration is prospective registration.
- 14 January 2019
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 20 (1) , 22
Open AccessSurgical injury and repair of hip external rotators in THA via posterior approach: a three-dimensional MRI-evident quantitative prospective study
As one of the classical total hip arthroplasty (THA) approaches, the posterior approach is widely used. However, there is a lack of in-depth quantitative researches on the surgical-related injury to the hip external rotators. The purpose of this study is to quantificationally analyse the surgical injury of hip external rotators after posterior THA and explore the effect of the muscle repair on the muscle recovery using the MRI three-dimensional reconstruction technique combined with the clinical assessment. Sixty five patients were eligible to receive a unilateral cementless THA via the posterior approach. During operation, the piriformis tendon was reattached but it was not applicable for the internal obturator muscle. We performed three-dimensional MRI reconstruction of bilateral piriformis and internal obturator muscle along with clinical assessment preoperatively, 6, 12 and 52 weeks postoperatively. Bilateral piriformis and internal obturator muscle were homogeneous preoperatively. Compared with the contralateral side, the volume atrophy and fat-muscle ratio of the piriformis on the operated side increased inconspicuously by 1.64%, 0.26% (p = 0.062, p = 0.071) at 6 weeks and 1.33%, 0.20% (p = 0.057, p = 0.058) at 12 weeks, while 7.28%, 2.09% and 15.71%, 5.14% for the internal obturator muscle (p < 0.01). Up to 52 weeks, the pirformis also showed significant muscle atrophy as well as fatty infiltration (increased by 7.79%, 4.21%; p < 0.01), and 24.18%, 11.91% for the internal obturator muscle (p < 0.01). The THA via posterior approach significantly harms the hip external rotators and the early hip external rotation function. The effective repair could be conducive to the early postoperative recovery of the hip external rotators. The study has been registered in Chinese Clinical Trial Registry (ChiCTR) before the clical trial started, the Clinical Trial Registry Number is ChiCTR-IOR-17013007 . Registered 17 October 2017. The Trial registration is prospective registration.
- 21 December 2018
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 33 (01) , 053-061
Effect of Tibial Component Alignment and Posterior Slope on Tibial Coverage in a Chinese Population: A Three-dimensional Anthropometric Study
The standard for rotational alignment and posterior slope of the tibial component in total knee arthroplasty remains controversial. This study aimed to evaluate the effect of tibial component alignment and posterior slope on tibial coverage. Computer tomographic scans of 101 tibial specimens were used to reconstruct three-dimensional tibia models. A virtual surgery was performed to generate a resection plane with different posterior slopes on the proximal tibia. Symmetrical and anatomical tibial components were placed aligning to the medial one-third of tibial tubercle (Insall) and the medial edge of patella tendon (Akagi), respectively. Differences in coverage and mismatch were evaluated and statistically compared across alignments, slope angles, and genders. The tibial coverage increased from 83.21 to 85.96% for Akagi's alignments and from 85.19 to 87.22% for Insall alignments along with the increasing of posterior slope from 0 to 7 degrees. Regardless of the prosthesis design, there was a significant difference between two rotational alignments as the Insall alignment was significantly higher in tibial coverage. With a slope of 7 degrees, more overhang along with less underhang anteromedially were found in males compared with females. The current anatomical tibial design has a tendency of overhang in the anteromedial zone which does not exist in the symmetrical design. The current tibial baseplate design has better tibial coverage when aligning to the medial third of tibial tuberosity with slopes of 5 and 7 degrees. Gender difference should be taken into account and given priority for prosthesis design. * Long Shao and Ting Wang contributed equally to this work and should be considered co-first authors.
- 21 December 2018
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 33 (01) , 053-061
Effect of Tibial Component Alignment and Posterior Slope on Tibial Coverage in a Chinese Population: A Three-dimensional Anthropometric Study
The standard for rotational alignment and posterior slope of the tibial component in total knee arthroplasty remains controversial. This study aimed to evaluate the effect of tibial component alignment and posterior slope on tibial coverage. Computer tomographic scans of 101 tibial specimens were used to reconstruct three-dimensional tibia models. A virtual surgery was performed to generate a resection plane with different posterior slopes on the proximal tibia. Symmetrical and anatomical tibial components were placed aligning to the medial one-third of tibial tubercle (Insall) and the medial edge of patella tendon (Akagi), respectively. Differences in coverage and mismatch were evaluated and statistically compared across alignments, slope angles, and genders. The tibial coverage increased from 83.21 to 85.96% for Akagi's alignments and from 85.19 to 87.22% for Insall alignments along with the increasing of posterior slope from 0 to 7 degrees. Regardless of the prosthesis design, there was a significant difference between two rotational alignments as the Insall alignment was significantly higher in tibial coverage. With a slope of 7 degrees, more overhang along with less underhang anteromedially were found in males compared with females. The current anatomical tibial design has a tendency of overhang in the anteromedial zone which does not exist in the symmetrical design. The current tibial baseplate design has better tibial coverage when aligning to the medial third of tibial tuberosity with slopes of 5 and 7 degrees. Gender difference should be taken into account and given priority for prosthesis design. * Long Shao and Ting Wang contributed equally to this work and should be considered co-first authors.