Matteo Chighizola
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Matteo Chighizola has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Podestà
Department of Physics “Aldo Pontremoli”, University of Milan, Milan, Italy
14 shared publications - Carsten Schulte
CIMAINA and Dipartimento di Fisica, Università degli Studi di Milano, via Celoria 16, 20133 Milano, Italy
12 shared publications - Cristina Lenardi
Dipartimento di Fisica “Aldo Pontremoli”, Università degli Studi di Milano, 20133 Milan, Italy
6 shared publications - Hatice Holuigue
Dipartimento di Fisica “Aldo Pontremoli”, Università degli Studi di Milano, Via G. Celoria 16, 20133, Milano, Italy
5 shared publications - Paolo Milani
CIMAINA and Dipartimento di Fisica “A. Pontremoli”, Università degli Studi di Milano, Milan, Italy
5 shared publications - Anita Previdi
CIMAINA and Dipartimento di Fisica, Università degli Studi di Milano, via Celoria 16, 20133 Milano, Italy
4 shared publications
Latest Publications
- Open Access
- 10 April 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 18 (19) , 10420-10436
Validation of contact mechanics models for atomic force microscopy via finite elements analysis and nanoindentation experiments
This work validates the application of Hertzian contact mechanics models and corrections on force-indentation curves obtained using spherical indenters on linear elastic samples, using finite elements analysis and AFM nanomechanical measurments.
- 10 April 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 18 (19) , 10420-10436
Open AccessValidation of contact mechanics models for atomic force microscopy via finite elements analysis and nanoindentation experiments
This work validates the application of Hertzian contact mechanics models and corrections on force-indentation curves obtained using spherical indenters on linear elastic samples, using finite elements analysis and AFM nanomechanical measurments.
- Open Access
- 7 September 2023
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 15 (37) , 15382-15395
Native extracellular matrix probes to target patient- and tissue-specific cell–microenvironment interactions by force spectroscopy
Native extracellular matrix probes for Atomic Force Microscopy can be successfully used for the quantitative investigation of the cellular mechanosensing of the microenvironment.
- 7 September 2023
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 15 (37) , 15382-15395
Open AccessNative extracellular matrix probes to target patient- and tissue-specific cell–microenvironment interactions by force spectroscopy
Native extracellular matrix probes for Atomic Force Microscopy can be successfully used for the quantitative investigation of the cellular mechanosensing of the microenvironment.
- Open Access
Native extracellular matrix probes to target patient- and tissue- specific cell-microenvironment interactions by force spectroscopy
Atomic Force Microscopy (AFM) is successfully used for the quantitative investigation of the cellular mechanosensing of the microenvironment. To this purpose, several force spectroscopy approaches aim at measuring the adhesive forces between two living cells and also between a cell and a suitable reproduction of the extracellular matrix (ECM), typically exploiting tips suitably functionalised with single components (e.g. collagen, fibronectin) of the ECM. However, these probes only poorly reproduce the complexity of the native cellular microenvironment and consequently of the biological interactions. We developed a novel approach to produce AFM probes that faithfully retain the structural and biochemical complexity of the ECM; this was achieved by attaching to an AFM cantilever a micrometric slice of native decellularised ECM, which was cut by laser microdissection. We demonstrate that these probes preserve the morphological, mechanical, and chemical heterogeneity of the ECM. Native ECM probes can be used in force spectroscopy experiments aimed at targeting cell-microenvironment interactions. Here, we demonstrate the feasibility of dissecting mechanotransductive cell-ECM interactions in the 10 pN range. As proof-of-principle, we tested a rat bladder ECM probe against the AY-27 rat bladder cancer cell line. On the one hand, we obtained reproducible results using different probes derived from the same ECM regions; on the other hand, we detected differences in the adhesion patterns of distinct bladder ECM regions, such as submucosa and detrusor, in line with the disparities in composition and biophysical properties of these ECM regions. Our results demonstrate that native ECM probes, produced from patient-specific regions of organs and tissues, can be used to investigate cell-microenvironment interactions and early mechanotransductive processes by force spectroscopy. This opens new possibilities in the field of personalised medicine.
Open AccessNative extracellular matrix probes to target patient- and tissue- specific cell-microenvironment interactions by force spectroscopy
Atomic Force Microscopy (AFM) is successfully used for the quantitative investigation of the cellular mechanosensing of the microenvironment. To this purpose, several force spectroscopy approaches aim at measuring the adhesive forces between two living cells and also between a cell and a suitable reproduction of the extracellular matrix (ECM), typically exploiting tips suitably functionalised with single components (e.g. collagen, fibronectin) of the ECM. However, these probes only poorly reproduce the complexity of the native cellular microenvironment and consequently of the biological interactions. We developed a novel approach to produce AFM probes that faithfully retain the structural and biochemical complexity of the ECM; this was achieved by attaching to an AFM cantilever a micrometric slice of native decellularised ECM, which was cut by laser microdissection. We demonstrate that these probes preserve the morphological, mechanical, and chemical heterogeneity of the ECM. Native ECM probes can be used in force spectroscopy experiments aimed at targeting cell-microenvironment interactions. Here, we demonstrate the feasibility of dissecting mechanotransductive cell-ECM interactions in the 10 pN range. As proof-of-principle, we tested a rat bladder ECM probe against the AY-27 rat bladder cancer cell line. On the one hand, we obtained reproducible results using different probes derived from the same ECM regions; on the other hand, we detected differences in the adhesion patterns of distinct bladder ECM regions, such as submucosa and detrusor, in line with the disparities in composition and biophysical properties of these ECM regions. Our results demonstrate that native ECM probes, produced from patient-specific regions of organs and tissues, can be used to investigate cell-microenvironment interactions and early mechanotransductive processes by force spectroscopy. This opens new possibilities in the field of personalised medicine.
- Open Access
- 19 September 2022
- Published by Springer Nature in Journal of Nanobiotechnology
- Vol. 20 (1) , 1-20
The glycocalyx affects the mechanotransductive perception of the topographical microenvironment
The cell/microenvironment interface is the starting point of integrin-mediated mechanotransduction, but many details of mechanotransductive signal integration remain elusive due to the complexity of the involved (extra)cellular structures, such as the glycocalyx. We used nano-bio-interfaces reproducing the complex nanotopographical features of the extracellular matrix to analyse the glycocalyx impact on PC12 cell mechanosensing at the nanoscale (e.g., by force spectroscopy with functionalised probes). Our data demonstrates that the glycocalyx configuration affects spatio-temporal nanotopography-sensitive mechanotransductive events at the cell/microenvironment interface. Opposing effects of major glycocalyx removal were observed, when comparing flat and specific nanotopographical conditions. The excessive retrograde actin flow speed and force loading are strongly reduced on certain nanotopographies upon strong reduction of the native glycocalyx, while on the flat substrate we observe the opposite trend. Our results highlight the importance of the glycocalyx configuration in a molecular clutch force loading-dependent cellular mechanism for mechanosensing of microenvironmental nanotopographical features. Graphical Abstract
- 19 September 2022
- Published by Springer Nature in Journal of Nanobiotechnology
- Vol. 20 (1) , 1-20
Open AccessThe glycocalyx affects the mechanotransductive perception of the topographical microenvironment
The cell/microenvironment interface is the starting point of integrin-mediated mechanotransduction, but many details of mechanotransductive signal integration remain elusive due to the complexity of the involved (extra)cellular structures, such as the glycocalyx. We used nano-bio-interfaces reproducing the complex nanotopographical features of the extracellular matrix to analyse the glycocalyx impact on PC12 cell mechanosensing at the nanoscale (e.g., by force spectroscopy with functionalised probes). Our data demonstrates that the glycocalyx configuration affects spatio-temporal nanotopography-sensitive mechanotransductive events at the cell/microenvironment interface. Opposing effects of major glycocalyx removal were observed, when comparing flat and specific nanotopographical conditions. The excessive retrograde actin flow speed and force loading are strongly reduced on certain nanotopographies upon strong reduction of the native glycocalyx, while on the flat substrate we observe the opposite trend. Our results highlight the importance of the glycocalyx configuration in a molecular clutch force loading-dependent cellular mechanism for mechanosensing of microenvironmental nanotopographical features. Graphical Abstract
- Open Access
The nanomechanical fingerprint of colorectal cancer -derived peritoneal metastasis
Peritoneal metastases (PM) are one of the most common routes of dissemination for colorectal cancer (CRC) and remain a lethal disease with a poor prognosis. The compositional, mechanical and structural properties of the extracellular matrix (ECM) play an important role in cancer development; studying how these properties change during the progression of the disease is crucial to understand CRC-PM development. The elastic properties of ECMs derived from human samples of normal and neoplastic PM in different pathological conditions were studied by atomic force microscopy (AFM); results were correlated to patients’ clinical data and to the expression of ECM components related to metastatic spread. Our results show that PM progression is accompanied by stiffening of ECM as a common feature; spatially resolved mechanical analysis highlighted significant spatial heterogeneity of the elastic properties of both normal and neoplastic ECMs, which show significant overlap in the two conditions. On the micrometre scale, ECMs that are considered normal according to the pathological classification possess stiffer spatial domains, which are typically associated with cancer associated fibroblasts (CAF) activity and tumour development in neoplastic matrices; on the other hand, softer regions are found in neoplastic ECMs on the same scales. Our results support the hypothesis that local changes (stiffening) in the normal ECM can create the ground for growth and spread from the tumour of invading metastatic cells. Mechanical changes correlate well with the presence of CAF and an increase in collagen deposition, which are well known markers of cancer progression. Furthermore, we have found correlations between the mechanical properties of the ECM and patients’ clinical data like age, sex, presence of mutations in BRAF and KRAS genes and tumour grade. Overall, our findings suggest that the mechanical phenotyping of the PM-ECM has the potential for predicting tumour development.
Open AccessThe nanomechanical fingerprint of colorectal cancer -derived peritoneal metastasis
Peritoneal metastases (PM) are one of the most common routes of dissemination for colorectal cancer (CRC) and remain a lethal disease with a poor prognosis. The compositional, mechanical and structural properties of the extracellular matrix (ECM) play an important role in cancer development; studying how these properties change during the progression of the disease is crucial to understand CRC-PM development. The elastic properties of ECMs derived from human samples of normal and neoplastic PM in different pathological conditions were studied by atomic force microscopy (AFM); results were correlated to patients’ clinical data and to the expression of ECM components related to metastatic spread. Our results show that PM progression is accompanied by stiffening of ECM as a common feature; spatially resolved mechanical analysis highlighted significant spatial heterogeneity of the elastic properties of both normal and neoplastic ECMs, which show significant overlap in the two conditions. On the micrometre scale, ECMs that are considered normal according to the pathological classification possess stiffer spatial domains, which are typically associated with cancer associated fibroblasts (CAF) activity and tumour development in neoplastic matrices; on the other hand, softer regions are found in neoplastic ECMs on the same scales. Our results support the hypothesis that local changes (stiffening) in the normal ECM can create the ground for growth and spread from the tumour of invading metastatic cells. Mechanical changes correlate well with the presence of CAF and an increase in collagen deposition, which are well known markers of cancer progression. Furthermore, we have found correlations between the mechanical properties of the ECM and patients’ clinical data like age, sex, presence of mutations in BRAF and KRAS genes and tumour grade. Overall, our findings suggest that the mechanical phenotyping of the PM-ECM has the potential for predicting tumour development.
- Open Access
Force Sensing on Cells and Tissues by Atomic Force Microscopy
Biosensors are aimed at detecting tiny physical and chemical stimuli in biological systems. Physical forces are ubiquitous, being implied in all cellular processes, including cell adhesion, migration, and differentiation. Given the strong interplay between cells and their microenvironment, the extracellular matrix (ECM) and the structural and mechanical properties of the ECM play an important role in the transmission of external stimuli to single cells within the tissue. Vice versa, cells themselves also use self-generated forces to probe the biophysical properties of the ECM. ECM mechanics influence cell fate, regulate tissue development, and show peculiar features in health and disease conditions of living organisms. Force sensing in biological systems is therefore crucial to dissecting and understanding complex biological processes, such as mechanotransduction. Atomic Force Microscopy (AFM), which can both sense and apply forces at the nanoscale, with sub-nanonewton sensitivity, represents an enabling technology and a crucial experimental tool in biophysics and mechanobiology. In this work, we report on the application of AFM to the study of biomechanical fingerprints of different components of biological systems, such as the ECM, the whole cell, and cellular components, such as the nucleus, lamellipodia and the glycocalyx. We show that physical observables such as the (spatially resolved) Young’s Modulus (YM) of elasticity of ECMs or cells, and the effective thickness and stiffness of the glycocalyx, can be quantitatively characterized by AFM. Their modification can be correlated to changes in the microenvironment, physio-pathological conditions, or gene regulation.
Open AccessForce Sensing on Cells and Tissues by Atomic Force Microscopy
Biosensors are aimed at detecting tiny physical and chemical stimuli in biological systems. Physical forces are ubiquitous, being implied in all cellular processes, including cell adhesion, migration, and differentiation. Given the strong interplay between cells and their microenvironment, the extracellular matrix (ECM) and the structural and mechanical properties of the ECM play an important role in the transmission of external stimuli to single cells within the tissue. Vice versa, cells themselves also use self-generated forces to probe the biophysical properties of the ECM. ECM mechanics influence cell fate, regulate tissue development, and show peculiar features in health and disease conditions of living organisms. Force sensing in biological systems is therefore crucial to dissecting and understanding complex biological processes, such as mechanotransduction. Atomic Force Microscopy (AFM), which can both sense and apply forces at the nanoscale, with sub-nanonewton sensitivity, represents an enabling technology and a crucial experimental tool in biophysics and mechanobiology. In this work, we report on the application of AFM to the study of biomechanical fingerprints of different components of biological systems, such as the ECM, the whole cell, and cellular components, such as the nucleus, lamellipodia and the glycocalyx. We show that physical observables such as the (spatially resolved) Young’s Modulus (YM) of elasticity of ECMs or cells, and the effective thickness and stiffness of the glycocalyx, can be quantitatively characterized by AFM. Their modification can be correlated to changes in the microenvironment, physio-pathological conditions, or gene regulation.
- Open Access
Force sensing on cells and tissues by atomic force microscopy
Biosensors are aimed to detect tiny physical and chemical stimuli in biological systems. Physical forces are ubiquitous, being implied in all cellular processes, including cell adhesion, migration, and differentiation. Given the strong interplay between cells and their microenvironment, the extracellular matrix (ECM), the structural and mechanical properties of the ECM play an important role in the transmission of external stimuli to single cells within the tissue. Vice versa, also cells themselves use self-generated forces to probe the biophysical properties of the ECM. ECM mechanics influences cell fate, regulates tissue development and show peculiar features in health and disease conditions of living organisms. Force sensing in biological systems is therefore crucial to dissect and understand complex biological processes, such as mechanotransduction. Atomic Force Microscopy (AFM), which can both sense and apply forces at the nanoscale, with sub-nanoNewton sensitivity, represents an enabling technology and a crucial experimental tool in biophysics and mechanobiology. In this work, we report on the application of AFM to study of biomechanical fingerprints of different components of biological systems, such as the ECM, the whole cell, and cellular components, like the nucleus and the glycocalyx. We show that physical observables like the (spatially resolved) Young’s modulus of elasticity of ECMs or cells, and the effective thickness and stiffness of the glycocalyx, can be quantitatively characterised by AFM. Their modification can be correlated to changes of the microenvironment, physio-pathological conditions, or gene regulation.
Open AccessForce sensing on cells and tissues by atomic force microscopy
Biosensors are aimed to detect tiny physical and chemical stimuli in biological systems. Physical forces are ubiquitous, being implied in all cellular processes, including cell adhesion, migration, and differentiation. Given the strong interplay between cells and their microenvironment, the extracellular matrix (ECM), the structural and mechanical properties of the ECM play an important role in the transmission of external stimuli to single cells within the tissue. Vice versa, also cells themselves use self-generated forces to probe the biophysical properties of the ECM. ECM mechanics influences cell fate, regulates tissue development and show peculiar features in health and disease conditions of living organisms. Force sensing in biological systems is therefore crucial to dissect and understand complex biological processes, such as mechanotransduction. Atomic Force Microscopy (AFM), which can both sense and apply forces at the nanoscale, with sub-nanoNewton sensitivity, represents an enabling technology and a crucial experimental tool in biophysics and mechanobiology. In this work, we report on the application of AFM to study of biomechanical fingerprints of different components of biological systems, such as the ECM, the whole cell, and cellular components, like the nucleus and the glycocalyx. We show that physical observables like the (spatially resolved) Young’s modulus of elasticity of ECMs or cells, and the effective thickness and stiffness of the glycocalyx, can be quantitatively characterised by AFM. Their modification can be correlated to changes of the microenvironment, physio-pathological conditions, or gene regulation.
- Open Access
The glycocalyx affects the mechanotransductive perception of the topographical microenvironment
The cell/microenvironment interface is the starting point of integrin-mediated mechanotransduction, but many details of mechanotransductive signal integration remain elusive due to the complexity of the involved (extra)cellular structures, such as the glycocalyx. We used nano-bio-interfaces reproducing the complex nanotopographical features of the extracellular matrix to analyse the glycocalyx impact on PC12 cell mechanosensing at the nanoscale ( e.g ., by force spectroscopy with functionalised probes). Our data demonstrates that the glycocalyx configuration affects spatio-temporal nanotopography-sensitive mechanotransductive events at the cell/microenvironment interface. Opposing effects of glycocalyx removal were observed, when comparing flat and specific nanotopographical conditions. The excessive retrograde actin flow speed and force loading are strongly reduced on certain nanotopographies upon removal of the native glycocalyx, while on the flat substrate we observe the opposite trend. Our results highlight the importance of the glycocalyx configuration in a molecular clutch force loading-dependent cellular mechanism for mechanosensing of microenvironmental nanotopographical features.
Open AccessThe glycocalyx affects the mechanotransductive perception of the topographical microenvironment
The cell/microenvironment interface is the starting point of integrin-mediated mechanotransduction, but many details of mechanotransductive signal integration remain elusive due to the complexity of the involved (extra)cellular structures, such as the glycocalyx. We used nano-bio-interfaces reproducing the complex nanotopographical features of the extracellular matrix to analyse the glycocalyx impact on PC12 cell mechanosensing at the nanoscale ( e.g ., by force spectroscopy with functionalised probes). Our data demonstrates that the glycocalyx configuration affects spatio-temporal nanotopography-sensitive mechanotransductive events at the cell/microenvironment interface. Opposing effects of glycocalyx removal were observed, when comparing flat and specific nanotopographical conditions. The excessive retrograde actin flow speed and force loading are strongly reduced on certain nanotopographies upon removal of the native glycocalyx, while on the flat substrate we observe the opposite trend. Our results highlight the importance of the glycocalyx configuration in a molecular clutch force loading-dependent cellular mechanism for mechanosensing of microenvironmental nanotopographical features.
- 26 February 2021
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 13 (12) , 6212-6226
Stiffening of DU145 prostate cancer cells driven by actin filaments – microtubule crosstalk conferring resistance to microtubule-targeting drugs
Cell stiffening induced by anticancer microtubule targeting drugs (MTDs) such as vinflunine (VFL), colchicine (COL), and docetaxel (DTX) can be driven by crosstalk between actin filaments and microtubules.
- 26 February 2021
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 13 (12) , 6212-6226
Stiffening of DU145 prostate cancer cells driven by actin filaments – microtubule crosstalk conferring resistance to microtubule-targeting drugs
Cell stiffening induced by anticancer microtubule targeting drugs (MTDs) such as vinflunine (VFL), colchicine (COL), and docetaxel (DTX) can be driven by crosstalk between actin filaments and microtubules.
- 24 October 2020
- Published by Wiley in Journal of Molecular Recognition
- Vol. 34 (1) , e2849
Large colloidal probes for atomic force microscopy: Fabrication and calibration issues
Atomic force microscopy (AFM) is a powerful tool to investigate interaction forces at the micro and nanoscale. Cantilever stiffness, dimensions and geometry of the tip can be chosen according to the requirements of the specific application, in terms of spatial resolution and force sensitivity. Colloidal probes (CPs), obtained by attaching a spherical particle to a tipless (TL) cantilever, offer several advantages for accurate force measurements: tunable and well‐characterisable radius; higher averaging capabilities (at the expense of spatial resolution) and sensitivity to weak interactions; a well‐defined interaction geometry (sphere on flat), which allows accurate and reliable data fitting by means of analytical models. The dynamics of standard AFM probes has been widely investigated, and protocols have been developed for the calibration of the cantilever spring constant. Nevertheless, the dynamics of CPs, and in particular of large CPs, with radius well above 10 μm and mass comparable, or larger, than the cantilever mass, is at present still poorly characterized. Here we describe the fabrication and calibration of (large) CPs. We describe and discuss the peculiar dynamical behaviour of CPs, and present an alternative protocol for the accurate calibration of the spring constant.
- 24 October 2020
- Published by Wiley in Journal of Molecular Recognition
- Vol. 34 (1) , e2849
Large colloidal probes for atomic force microscopy: Fabrication and calibration issues
Atomic force microscopy (AFM) is a powerful tool to investigate interaction forces at the micro and nanoscale. Cantilever stiffness, dimensions and geometry of the tip can be chosen according to the requirements of the specific application, in terms of spatial resolution and force sensitivity. Colloidal probes (CPs), obtained by attaching a spherical particle to a tipless (TL) cantilever, offer several advantages for accurate force measurements: tunable and well‐characterisable radius; higher averaging capabilities (at the expense of spatial resolution) and sensitivity to weak interactions; a well‐defined interaction geometry (sphere on flat), which allows accurate and reliable data fitting by means of analytical models. The dynamics of standard AFM probes has been widely investigated, and protocols have been developed for the calibration of the cantilever spring constant. Nevertheless, the dynamics of CPs, and in particular of large CPs, with radius well above 10 μm and mass comparable, or larger, than the cantilever mass, is at present still poorly characterized. Here we describe the fabrication and calibration of (large) CPs. We describe and discuss the peculiar dynamical behaviour of CPs, and present an alternative protocol for the accurate calibration of the spring constant.